Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

Similar documents
Spreader Valves SPR-2FFL12, SPR-2FFLC12 & SPR-2FFLW86

Cartridge Valves Technical Information. Spreader Valves. Spreader Valves SCHEMATIC MODEL PRESSURE FLOW* WEIGHT SPR-2FFL12 SPR-2FFLC12 SPR-2FFLW86

Cartridge Valves Technical Information Directional Valves DCV 03

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

ELECTRIC CARTRIDGES ELECTRO-PROPORTIONAL VALVES

Functional Description

Proportional Valves. Proportional solenoid valves for pressure and flow control

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

Mobile Valves Proportional - Load Sensing

COILS AND CONNECTORS. Atlantic Fluid Tech SECTION 21. Rev. 10/ Connector Page class

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012

Directional Control Valves

Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C1040 PDFC-4M PDFC-4L

VSD*S -MONITORED DIRECTIONAL CONTROL VALVES

Available manual, pneumatic, and hydraulic spool control kits.

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

inspired hydraulics. Modular valve range MOVE

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2012. Replaces HA /2010

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls

CLS100 Proportional Load Sensing Mobile Valve

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2014. Replaces HA /2013

VED*MG - PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

PRESSURE CONTROLS TECNORD

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

6 to14/2 ways/positions bankable flow diverters flangeable

D05 Directional Control Valves

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED

6 to 12/2 ways/positions bankable flow diverters flangeable

Proportional Pressure Reducing Valve, Size 16 Series DRPSB 5B...

SR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design

CONTINENTAL HYDRAULICS VAD05M-VMD05M - AIR & LEVER OPERATED DIRECTIONAL VALVES

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

P.C. Priority Flow Control Valve Series J02D3. General Description

HY-SPEC CATALOGUE - HYDRAULIC VALVES. Hydraulic Valves. Visit our website Catalogue

Post-Compensated Proportional Valve CV2000LS

Pressure Control Valves

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Directional Control Valve Series D3W Soft Shift

VER03M CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES VER03M - PROPORTIONAL PRESSURE RELIEF VALVES

VED*MJ PILOT OPERATED DIRECTIONAL CONTROL VALVES WITH OBE & FEEDBACK

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

SECTIONAL BODY. Model SV. Directional Control Valves VALVES STANDARD FEATURES SPECIFICATIONS. Parallel or Series Circuit Construction ...

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

6 to14/2 ways/positions bankable flow diverters flangeable

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

Pressure Control Valves Series R. General Description. Specifications. Flow Data

HP3V SERIES. Swash-plate Type Axial Piston Variable Displacement Pump

Proportional Flow-Control Cartridges, Size 5

Flow sharing control block in mono block / sandwich plate design M6-22

6 to14/2 ways/positions bankable flow diverters flangeable

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Pilot-Operated Proportional DC Valve Series D*1FH

6/2 ways/positions flow diverters

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

Proportional Valve Group PVG 128/256

6 to 12/2 ways/positions bankable flow diverters flangeable

20 l/min (5 GPM) p max. Technical Features

Flow control valve range

Cartridge Valves. Proportional Valves Screw-in Cartridge Valves. Vickers. Maximum Pressure 280 bar (4000 psi) - Maximum Flow 160 l/min (42 USgpm)

CLS180 Proportional Load Sensing Mobile Valve

MONOBLOCK DIRECTIONAL CONTROL VALVES

Data sheet for MATRE BALANCED FOAM PROPORTIONERS

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK

Monoblock Directional Control Valve PMB22TSTSAB PMB23TSTSTSLB PMB21TDLB

DIRECTIONAL CONTROL VALVES CETOP 3/NG6

Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO...

PACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE.

Line mounting From SAE08 to SAE16 cavities. 15 l/min (3.9 US gpm) from -20 C (-4 F) to 80 C (176 F) from -20 C (-4 F) to 100 C (212 F)

Directional Valves. Pilot Operated Directional Valves. Vickers. Service Data

4-Way Directional Control With Pressure Compensated Flow Control PSDCF120M64LF Specifications:

(F*) - DG5V -10- * - (R) - (B) - **(L) - (**) - (X) - (*) - (E) - (T) - (*) - (V)M - (S*) - * ** * * (L) - (*) ** - (***) (EN***)

6/2 ways/positions flow diverters

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

V050 SERIES DIRECTIONAL CONTROL VALVE

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING

Pressure Reducing Valves

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

4/3-4/2 Directional valve elements B8_0A with or without (EDB-A) secondary relief valves, with or without LS connections B8_0A (EDB-A)

Transcription:

Control Cartridge Valves: PSV10-34 & PSV12-34 SCHEMATIC PRESSURE* FLOW CAVITY COIL Page 2 PSV10-34-02 250 BAR 3600 PSI 22 LPM 6 GPM SDC10-4 M16-26W R16-20W Page 4 PSV12-34-02 260 BAR 3770 PSI 50 LPM 13 GPM CP12-4 M19-33W Page 6 PSV10-34-05 250 BAR 3600 PSI 22 LPM 6 GPM SDC10-4 M16-26W R16-20W Page 8 PSV12-34-05 260 BAR 3770 PSI 60 LPM 16 GPM CP12-4 M19-33W CETOP Adapter Blocks Order Code Material Number Page 10 D03 Adapter Block D03 SDC10-4-D03 11119395 D03 Adapter Block- Pressure Compensator SDC10-4-D03-PC 11119399 D05 Adapter Block CP12-4-D05 11110408 Page 11 D05 Adapter Block- Pressure Compensator CP12-4-D05-PC 11120560 Control Valves Rev AB August 2012 1

OPERATION This is a proportional, non-compensated, 3 position 4 way, directional flow control solenoid valve, with closed-center spool. APPLICATIONS This is an electro-proportional directional control using a 3-Position, 4-Way design for directional control of hydraulic cylinders and motors. For load-independent flow control, apply with a pressure compensator, like CP700-4 (see Example Circuit). Port 1 should be used as the tank port, with a maximum back-pressure of 150 bar. The highest return flow coming from a cylinder should be connected to Port 2. PSV10-34-02 Shown with standard coils, DIN connectors SCHEMATIC Shown with Robust Coil Use the available Comatrol Adapter Block to help test and replace proportional CETOP D03 - available in compensated or non-compensated. Select the robust coil for those extreme environmental conditions - voltage extremes, high temperature, shock & vibration, chemicals, and/or water ingression. Note: For optimal performance install with the solenoid valve below the tank oil level in the horizontal position, reducing the chance for trapped air in the valve. SPECIFICATIONS Rated Pressure* Maximum Rated Flow at 7 bar [100 psi] Weight including coil Hysteresis Threshold current Maximum control current Cavity Standard Coil Robust Coil 250 bar [3600 psi] 22 l/min [6 US gal/min] 0.77 kg [1.7 lbs] 4% maximum 0.5 A (12 VDC coil) 0.25 A (24 VDC coil) 1.5 A (12 VDC coil) 0.8 A (24 VDC coil) SDC10-4 M16 26 Watt R16 20 Watt Robust Nut P/N 173804910 (no coil O-rings needed) PERFORMANCE CURVES Operating curves with M16 coil and plastic nut * Rated Pressure based on NFPA fatigue test standards (at 1 Million Cycles). Operating curves with R16 coil and steel nut Control Valves Rev AB August 2012 2

DIMENSIONS PSV10-34-02 S2 24mm 9-11 Nm [6-8 lbf*ft] KIT P/N 17400031 27mm 45-50 Nm [33-37 lbf*ft] S1 7/8-14 UNF 2A A P B T Ø 26.5 [Ø 1.04] COILS NOT SHOWN FOR CLARITY INSTALL O-RINGS (4) PLCS AS SHOWN 127.5 [5.01] 5 [0.2] 62 [2.44] P103 824 EXAMPLE CIRCUITS Compensated Bi-directional Proportional Flow Control Double Acting Cylinder with Proportional Speed Control, Unloading Valve and Circuit Relief ORDERING INFORMATION PSV 10-34 - 02-12D - DE - 22 - B - 00 Proportional Solenoid Valve, Non-compensated Flow Control Cavity Size: 10 = Size 10 Housing and Ports: Housing P/N: 00 = No Housing No Housing L3B = AL 3/8 BSP SDC10-4-L-3B L4B = AL, 1/2 BSP SDC10-4-L-4B 6S = AL #6 SAE CP10-4-6S 8S = AL, #8 SAE CP10-4-8S Other housings available Type 34 = 3 Position, 4 Way Schematic: 02 = Closed Center Spool Coil Voltage: 00 = No Coil 12D = 12 VDC 24D = 24 VDC R12D = 12 VDC R-Coil R24D = 24 VDC R-Coil Coil Termination 00 = No coil, with Nut AJ = AMP Junior* AS = AMP SuperSeal 1.5 DE = Deutsch DN = DIN 46650* FL = Flying Leads *These terminations are not available on robust coil (R12D, R24D) Seals: Seal Kit B = Buna-N 354001919 V = Viton 354002019 Max Regulated Flow: 12 = 12 LPM (3 GPM) 22 = 22 LPM (6 GPM) Control Valves Rev AB August 2012 3

APPLICATIONS PSV12-34-02 OPERATION This is a proportional, non-compensated, 3 position 4 way, directional flow control solenoid valve, with closed-center spool. This is an electro-proportional directional control using a 3-Position, 4-Way design for directional control of hydraulic cylinders and motors. For loadindependent flow control, apply with a pressure compensator, like CP701-4 (see Example Circuit). Port 1 should be used as the tank port, with a maximum back-pressure of 150 bar. The highest return flow coming from a cylinder should be connected to Port 2. Use the available Comatrol Adapter Block to help test and replace proportional CETOP D05 - available in compensated or non-compensated. Note: For optimal performance install with the solenoid valve below the tank oil level in the horizontal position, reducing the chance for trapped air in the valve. Shown with Deutsch connector Shown with DIN connector SPECIFICATIONS Rated Pressure* 260 bar [3770 psi] Rated Flow at 10 bar 50 l/min (145 psi) [13 US gal/min] Weight including coil 1.2 kg [2.64 lbs] Hysteresis <4% Threshold current 0.25 A (12 VDC coil) 0.50 A (24 VDC coil) Maximum control 1.8 A (12 VDC coil) current 0.9 A (24 VDC coil) Cavity CP12-4 Standard Coil M19 33 Watt SCHEMATIC * Rated Pressure based on NFPA fatigue test standards (at 1 Million Cycles). PERFORMANCE CURVES Control Valves Rev AB August 2012 4

DIMENSIONS PSV12-34-02 EXAMPLE CIRCUITS Compensated Bi-directional Proportional Flow Control Double Acting Cylinder with Proportional Speed Control, Unloading Valve and Circuit Relief ORDERING INFORMATION PSV 12-34 - 02-50 12D - - DE - B - 00 Proportional Solenoid Valve, Non-compensated, Flow Control Cavity Size: 12 = Size 12 Type: 34 = 3 Position, 4 Way Schematic: 02 = Closed Center Spool Max Regulated Flow: 30 = 30 LPM (8 GPM) 50 = 50 LPM (13 GPM) Coil Voltage: 00 = No Coil 12D = 12 VDC 24D = 24 VDC Housing and Ports: 00 = No Housing 3B = AL, 3/8 BSP 4B = AL, 1/2 BSP 8S = AL, #8 SAE 10S = AL, #10 SAE *Other housings available Seals: Seal Kits: B = Buna-N 11106420 V = Viton 11106444 Coil Termination: 00 = No coil, with Nut AJ = AMP Junior AS = AMP SuperSeal 1.5 DE = Deutsch DN = DIN 46650 FL = Flying Leads Housing P/N: No Housing CP12-4-3B CP12-4-4B CP12-4-8S CP12-4-10S Control Valves Rev AB August 2012 5

OPERATION This is a proportional, non-compensated, 3 position 4 way, directional flow control solenoid valve, with float-center spool. APPLICATIONS This is an electro-proportional directional control using a 3-Position, 4-Way design for directional control of hydraulic cylinders and motors. For load-independent flow control, apply with a pressure compensator, like CP700-4 (see Example Circuit). Port 1 should be used as the tank port, with a maximum backpressure of 150 bar. The highest return flow coming from a cylinder should be connected to Port 2. Use the available Comatrol Adapter Block to help test and replace proportional CETOP D03 - available in compensated or non-compensated. Select the robust coil for those extreme environmental conditions - voltage extremes, high temperature, shock & vibration, chemicals, and/or water ingression. PSV10-34-05 Shown with DIN connector, standard coil SCHEMATIC Shown with Robust Coil Note: For optimal performance install with the solenoid valve below the tank oil level in the horizontal position, reducing the chance for trapped air in the valve. SPECIFICATIONS Rated Pressure* Maximum Rated Flow at 7 bar [100 psi] Weight including coil Hysteresis Threshold current Maximum control current Cavity Standard Coil Robust Coil 250 bar [3600 psi] 22 l/min [6 US gal/min] 0.77 kg [1.7 lbs] 4% maximum 0.5 A (12 VDC coil) 0.25 A (24 VDC coil) 1.5 A (12 VDC coil) 0.8 A (24 VDC coil) SDC10-4 M16 26 Watt R16 20 Watt Robust Nut P/N 173804910 (no coil O-rings needed) PERFORMANCE CURVES Operating curves with M16 coil and plastic nut * Rated Pressure based on NFPA fatigue test standards (at 1 Million Cycles). Operating curves with R16 coil and steel nut Control Valves Rev AB August 2012 6

DIMENSIONS PSV10-34-05 A P B T Ø 26.5 [Ø 1.04] 127.25 [5.01] 5 [0.2] 62 [2.44] P103 825 EXAMPLE CIRCUITS Compensated Bi-directional Proportional Flow Control Double Acting Cylinder with Proportional Speed Control and Load Holding ORDERING INFORMATION PSV 10-34 - 05-12D - DE - 22 - B - 00 Proportional Solenoid Valve, Non-compensated Flow Control Cavity Size: 10 = Size 10 Housing and Ports: Housing P/N: 00 = No Housing No Housing L3B = AL 3/8 BSP SDC10-4-L-3B L4B = AL, 1/2 BSP SDC10-4-L-4B 6S = AL #6 SAE CP10-4-6S 8S = AL, #8 SAE CP10-4-8S Other housings available Type 34 = 3 Position, 4 Way Schematic: 05 = Float Center Spool Coil Voltage: 00 = No Coil 12D = 12 VDC 24D = 24 VDC R12D = 12 VDC R-Coil R24D = 24 VDC R-Coil Coil Termination 00 = No coil, with Nut AJ = AMP Junior AS = AMP SuperSeal 1.5 DE = Deutsch DN = DIN 46650 FL = Flying Leads *These terminations are not available on robust coil (R12D, R24D) Seals: Max Regulated Flow: 3 = 3 LPM (0.8 GPM) 12 = 12 LPM (3 GPM) 22 = 22 LPM (6 GPM) Seal Kit B = Buna-N 354001919 V = Viton 354002019 Control Valves Rev AB August 2012 7

OPERATION PSV12-34-05 This is a proportional, non-compensated, 3 position 4 way, directional flow control solenoid valve, with float-center spool. APPLICATIONS This is an electro-proportional directional control using a 3-Position, 4-Way design for directional control of hydraulic cylinders and motors. For load-independent flow control, apply with a pressure compensator, like CP701-4 (see Example Circuit). Port 1 should be used as the tank port, with a maximum back-pressure of 150 bar. The highest return flow coming from a cylinder should be connected to Port 2. Use the available Comatrol Adapter Block to help test and replace proportional CETOP D05 - available in compensated or non-compensated. Note: For optimal performance install with the solenoid valve below the tank oil level in the horizontal position, reducing the chance for trapped air in the valve. Shown with Deutsch connector Shown with DIN connector SPECIFICATIONS SCHEMATIC Rated Pressure* 260 bar [3770 psi] Maximum Rated Flow 60 l/min at 7 bar [100 psi] [16 US gal/min] Weight including coil 1.2 kg [2.64 lbs] Hysteresis 4% maximum Threshold current 0.5 A (12 VDC coil) 0.25 A (24 VDC coil) Maximum control 1.8 A (12 VDC coil) current 0.9 A (24 VDC coil) Cavity CP12-4 Standard Coil M19 33 Watt * Rated Pressure based on NFPA fatigue test standards (at 1 Million Cycles). PERFORMANCE CURVES Control Valves Rev AB August 2012 8

DIMENSIONS PSV12-34-05 EXAMPLE CIRCUITS Compensated Bi-directional Proportional Flow Control Double Acting Cylinder with Proportional Speed Control and Load Holding ORDERING INFORMATION PSV 12-34 - 05-60 12D - - DE - B - 00 Proportional Solenoid Valve, Non-compensated Flow Control Cavity Size: 12 = Size 12 Type: 34 = 3 Position, 4 Way Schematic: 05 = Float Center Spool Max Regulated Flow: 30 = 30 LPM (8 GPM) 60 = 60 LPM (16 GPM) Coil Voltage: 00 = No Coil 12D = 12 VDC 24D = 24 VDC Housing and Ports: Seals: Seal Kits: B = Buna-N 11106420 V = Viton 11106444 Coil Termination: 00 = No coil, with Nut AJ = AMP Junior AS = AMP SuperSeal 1.5 DE = Deutsch DN = DIN 46650 FL = Flying Leads Housing P/N: 00 = No Housing No Housing 3B = AL, 3/8 BSP CP12-4-3B 4B = AL, 1/2 BSP CP12-4-4B 8S = AL, #8 SAE CP12-4-8S 10S = AL, #10 SAE CP12-4-10S *Other housings available Control Valves Rev AB August 2012 9

D03 ADAPTER BLOCK - NON-COMPENSATED - SDC10-4-D03-11119395 These blocks are designed to be installed onto a CETOP D03 interface for comparison testing. Valves and mounting kits are not included and will need to be ordered and assembled by the user. This block was designed to fit the following valve: PSV10-34. Schematic (valves not included in block): CETOP D03 Interface Mounting Kits Description Kit Material Number Buna-N Seal Kit 158-8007 Viton Seal Kit 158-8062 M5 x 50 mm Bolts (4) 11120781 10-24 UNC x 3.6 Bolts (4) 11120812 Recommended Torque = 9 Nm (80 lbf in) D03 ADAPTER BLOCK - COMPENSATED - SDC10-4-D03-PC - 11119399 These blocks are designed to be installed onto a CETOP D03 interface for comparison testing. Valves and Mounting Kits are not included and will need to be ordered and assembled by the user. This block was designed to fit the following valves: PSV10-34, CP700-4 and CP124-1. Schematic (valves not included in block): CETOP D03 Interface Mounting Kits Description Kit Material Number Buna-N Seal Kit 158-8007 Viton Seal Kit 158-8062 M5 x 90 mm Bolts (4) 11120683 10-24 UNC x 3.6 Bolts (4) 11120684 Recommended Torque = 9 Nm (80 lbf in) Control Valves Rev AB August 2012 10

D05 ADAPTER BLOCK - NON-COMPENSATED - CP12-4-D05-11110408 These blocks are designed to be installed onto a CETOP D05 interface for comparison testing. Valves and Mounting Kits are not included and will need to be ordered and assembled by the user. This block was designed to fit the following valve: PSV12-34. Schematic (valves not included in block): B A CETOP D05 Interface D05 ADAPTER BLOCK - COMPENSATED - CP12-4-D05-11120560 These blocks are designed to be installed onto a CETOP D05 interface for comparison testing. Valves are not included and will need to be ordered and assembled by the user. This block was designed to fit the following valves: PSV12-34, CP701-4 and CP124-1. Mounting Kits Description Kit Material Number Buna-N Seal Kit 158-8023 Viton Seal Kit 158-8094 M6 x 40mm Bolts (4) 158-8024 1/4-20 x 1-5/8 Bolts (4) 11120605 Recommended Torque = 13.5 Nm (120 lbf in) Schematic (valves not included in block): B A CETOP D05 Interface Mounting Kits Description Kit Material Number Buna-N Seal Kit 158-8023 Viton Seal Kit 158-8094 M6 x 60mm Bolts (4) 11120602 1/4-20 x 2-1/2 Bolts (4) 11120603 Recommended Torque = 13.5 Nm (120 lbf in) Control Valves Rev AB August 2012 11