WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

Similar documents
WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

HCD-230 Industrial Control Damper

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

AMD-33 Air Measuring Station with VCD-33 Control Damper

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Model VCD-20 3V CONTROL DAMPER

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Thermal Isolation. Break

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

VCD-23 Low Leakage CONTROL DAMPER

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

VCD-23. Flange Options. Size Limitations

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

VCD-23. Low Leakage CONTROL DAMPER

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Model FSD-331 Combination Fire Smoke Dampers

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

PC-125x Counter-Balanced Backdraft Damper

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

ARROW UNITED INDUSTRIES

ARROW INDUSTRIAL PRODUCTS

HVAC Control & Balancing Dampers

ID-141x 12-Gauge Hat Channel Industrial Damper

Fusible Link (replaceable) Horizontal Mount

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Fusible Link (replaceable) Horizontal Mount

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Motorized Fire Dampers

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS

SD-1250 and SD-1600 Series Smoke Dampers

Air Measuring Products AMD AMS IAQ

AIR CONDITIONING PRODUCTS COMPANY

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief

BD-1600 Balancing/Zone Control Damper

MOUNTING ARRANGEMENT OPTIONS OVERVIEW

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

MODELS LCE/LCS, L2E/L2S, L3E/L3S

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

Introduction to Johnson Controls Dampers

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003

FSD60/MFSD60 Multi-blade Fire Damper

Direct Gas-Fired Heating

AD-1250 Airflow Measuring Station

HVAC Control & Balancing Dampers

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS

AFL-501. Aluminum FEMA 361 Louver Chevron Blade Application and Design

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

RM-1200 Slim Round Control Damper

MODELS GED/GSD, DFE/DFS, DDE/DDS DIRECT DRIVE SIDEWALL PROPELLER FANS WALL HOUSING MOUNTING OPTIONS WALL HOUSING

Square Inline Fans with Multi-Directional Discharge

Installation, Operation, and Maintenance Instructions

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

Transcription:

Application and Design The WD300 series dampers are designed to prevent reverse airflow in horizontal exhaust applications. The WD300 features a pressure sensitive blade design that opens and remains open under low velocity conditions. The dampers are opened by air pressure differential and closed by gravity. Optional motor pack converts the damper to motorized operation. Ratings Pressure: 2 in. wg (.5 kpa) differential pressure Velocity: 2500 fpm (13 m/s) Temperature: 180 F (82 C) Construction Standard Optional Frame Material Galvanized steel Frame Thickness Frame Type 18 ga. (1.3mm) No flange (WD330) Flange on intake (WD300) Flange on discharge (WD320) Blade Material Roll formed aluminum Blade Thickness 0.025 in. (0.64mm) 0.032 in. (0.8mm) for triple panel Blade Seals Vinyl Axle 3/16 in. (4.8mm) dia. zinc plated steel pin on blade ends 304SS Axle Bearings Synthetic 304SS Linkage Material Galvanized Steel WD300 Series Backdraft Damper Vertical Mount Horizontal Airflow W* W* *W & H dimensions furnished approximately 1/8 in. (3mm) undersize. Frame Styles 3 1/2 in. WD 300 Flange on Intake 1 1/2 in. Typical 2 3/4 in. Max. Typical 3 1/2 in. WD 320 Flange on Discharge 3 3/8 in. WD 330 No Flange Frame 5/8 in. Max. Typical Airflow Size Limitations W x H Minimum Size Maximum Size WD300 & WD320 Multiple s Inches 6 x 6 31 x 74 x mm 152 x 152 787 x 1880 3759 x 3759 WD330 Inches 6 x6 31 x 74 150 x mm 152 x 152 787 x 1880 3810 x 3759 Options End switch kit (part no. 851038) Motor packs (24V, 120V, 208240V, 440V) Installation instructions available at www.greenheck.com.

Performance Data Pressure Drop Performance data results from testing a 36 in. x 36 in. (914mm x 914mm) damper in accordance with AMCA Standard 500D using Figure 5.5 (unducted). All data has been corrected to represent standard air at 0.075 lb/ft 3 (1.201 kg/m 3 ). 1.2 WD300 Series Pressure Drop 36 in. x 36 in. (914mm x 914mm) Damper Operational Data Blades start to open Nonducted Blades fully open Nonducted ΔP in. wg (kpa) 0.05 (.012) 0.15 (.037) Velocity fpm (m/s) 300 (1.5) 900 (4.5) Pressure Drop in. wg 1.0 0.8 0.6 0.4 Full Open 0.2 Start Open 0.0 0 500 1000 1500 2000 2500 Velocity feet per minute (fpm) Leakage Leakage testing was conducted in accordance with AMCA Standard 500D and is expressed as CFM per sq. ft. of damper face area. All data has been corrected to represent standard air at 0.075 lb/ft 3 (1.201 kg/m 3 ). Leakage 36 in. x 36 in. (914mm x 914mm) Damper 3 2.5 Static Pressure Difference (in. wg) 2 1.5 1 0.5 0 10 20 30 40 50 60 70 80 90 Leakage (cfm/sq. ft)

WD300 Series Series MP310 motor pack may be field installed to convert the WD300 series backdraft damper to motorized operation. Airflow direction should remain horizontal exhaust when this motorized version is applied. These versatile motor packs feature power opening with spring return. The springs also provide damper closure in the event of electrical failure. The MP310 motor packs are available in voltages of 24, 120, 208, and 440. 575/600 volts may be used with any of the motor packs by way of a transformer (part no. 380711) and the appropriate 115 volt motor pack (MP310). MP310 series motor packs are UL listed. Please specify voltage when ordering. There is one motor pack available on the WD300 series damper to accommodate for larger torque requirements. To determine the number of motor packs required per WD300 or WD320 damper, refer to the table on page 5. To determine the number of motor packs required per WD330 damper, refer to the table on page 7. Oversized applications may require several dampers connected together for one opening. MP300 series motor packs are supplied with mounting hardware, assembly instructions and actuator arms for either single, double, or triple panel installation. Motor packs 24V (50/60 Hz) 440V (60Hz) 110V120V (50/60Hz) 208V 240V 50/60Hz Stall Amps.66.041.15.07 Spec ID# G24 G460 G110240 G110240 Motor Pack Dimensional Data WD300 series dampers are available with an optional motor pack (MP310). The diagram to the left illustrates the required clearance needed for proper operation of a mounted motor pack. Airflow 10 in. Minimum Space Required WD300 series backdraft damper with optional motorpack

WD300/320 Selection Multiple section dampers shown below are supplied as equal size sections. Any damper that has multiple sections, both vertically and horizontally, will require field assembly and will require additional reinforcement (not supplied by Greenheck) to support the assembly. These larger dampers must have the additional reinforcement to give them structural stability. The width dimension is always parallel to the length of the blades. Note: The type and number of motor packs required can be found on page 5. 6 6 6 Up To 32 Width 32 50 74 100 32 Up To 50 50 Up Thru 74 Above 74 Up To 100 100 Up Thru 6 Up Thru 74 Triple Three Height 74 Abover 74 Thru Triple Four Six *Width and height given in inches.

Motor Pack Selection for WD300/320 The table below will allow you to determine the type and number of motor packs needed for a given size WD300/320 backdraft damper. For further information on a particular motor pack, refer to page 3. 8 8 Width 50 100 >=8 and <50 >=50 and <100 >=100 and <= >=8 and <=74 (1) MP310 Motor Pack (2) MP310 (3) MP310 Height 74 (2) MP310 (4) MP310 (6) MP310 > 74 and <= *Width and height given in inches.

WD330 Selection Multiple section dampers shown below are supplied as equal size sections. Any damper that has multiple sections, both vertically and horizontally, will require field assembly and will require additional reinforcement (not supplied by Greenheck) to support the assembly. These larger dampers must have the additional reinforcement to give them structural stability. The width dimension is always parallel to the length of the blades. Note: The type and number of motor packs required can be found on page 7. 6 6 6 Up To 32 Width 32 50 64 100 128 32 Up Thru 50 Above 50 Up To 64 64 Up Thru 100 Above 100 Up To 128 128 Up Thru 150 150 6 Up Thru 74 Four Three Height 74 Above 74 Thru Four Four Eight Six *Width and height given in inches.

Motor Pack Selection for WD330 The table below will allow you to determine the type and number of motor packs needed for a given size WD330 backdraft damper. For further information on a particular motor pack, refer to page 3. 8 Width 50 100 128 150 8 >=8 and <=50 >50 and <=100 >100 and <128 >=128 and<=150 >=8 and <=74 (1) MP310 Motor Pack (2) MP310 (4) MP310 (3) MP310 Height 74 >74 and <= (2) MP310 (4) MP310 (8) MP310 (6) MP310 *Width and height given in inches.

End Switch Kit Specifications End Switch Kit (Optional) An end switch is a control device used in conjunction with a motor pack (the end switch is usually wired to a fan and/or to a light serving as an open/not open indicator). When the damper is powered open, the blades of the damper hit the spring rod of the end switch which in turn makes a connection allowing power to flow to the fan and/or light. This set up would be used when it is desirable to ensure that the damper is fully open before the fan starts. Otherwise, with the damper blades are not fully open, the pressure and air velocity produced by the fan may damage the blades, making the damper inoperable. Spring Rod Vertically Mounted Damper Specifications Backdraft dampers meeting the following specifications shall be furnished and installed where shown on plans and/or described in schedules. Dampers shall consist of : 18 ga. (1.3mm) galvanized steel frame with 3 1/2 in. (89mm) depth; blades from 0.025 in. 0.032 in. (.6mm.8mm) rollformed aluminum; 3/16 in. (4.8mm) dia. plated steel stub axles turning in acetal bearings; damper shall be equipped with extruded vinyl blade seals; and internal 20 ga. (1mm) galvanized steel tie bar (onblade). Damper manufacturer s printed application and performance data including pressure, velocity, and temperature limitations shall be submitted for approval showing damper suitable for pressures to 2 in. wg (.5 kpa), velocities to 2500 fpm (13 m/s) and temperatures to 180 F (82 C). Testing and ratings to be in accordance with AMCA Standard 500D. Basis of design is model WD300. Copyright 2018 Greenheck Corporation WD300 Rev. 13 December 2018