Documentation. RM-BV4 Micro DP. Filter control

Similar documents
ECONOMISER SERIES E2T USER MANUAL

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

INSTALLATION USER MANUAL

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

PRELIMINARY UNIT OPERATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Pressure chlorine changeover unit C 7520

Total Control Board. Installation, Operation and Maintenance Manual. Publication 2949A (GB) (From October 2007)

Application Engineering

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Two Channel Remote Shutdown Device

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Electronic Ballast EVG 2000-T

Operating manual UPS - System

EC DECLARATION OF CONFORMITY

Application Engineering

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

Industrial Controls. Load Feeders and Motor Starters. SIRIUS MCU Motor Starters. Gerätehandbuch. Answers for industry.

Combined Motor Start and Braking Device VBMS... Assembly- and Commissioning Instructions

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

GRUNDFOS INSTRUCTIONS. Control HVAC. Installation and operating instructions. Other languages. net.grundfos.com/qr/i/

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

Congratulations. You ve just purchased the most advanced flasher available on the market today. This

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Commissioning Instructions Inbetriebnahme Anleitung VB 230/ L (LP)

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Trouble Shooting. Symptom Possible Cause Solution Power switch ON but switch Light is Off. Main power to unit Off. Switch light defective.

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

ED900. Low energy operator. Customizing Features: Book 3 of 3

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

User Manual Solar Charge Controller 3KW

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

ENGINE PROTECTION BOARD PDM1

REVISION HISTORY REVISION HISTORY

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

User Manual. Solar Charge Controller 3KW

Yaskawa AC Drive L1000A Supplement to the L1000A Technical Manual No. SIEP C , SIEP C , and SIEP C

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL

Important instructions

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Manual for Inverter system type PCI05

INSTALLATION AND OPERATION INSTRUCTION

ZE motor-protective relay Overload monitoring of EEx e motors

c-go 24V/6A 24V/8A 24V/12A

HV-Angle Valve (Series 264) HV-InlineValve (Series 265) with electromagnetic actuator single acting with closing spring (NC)

Technical Documentation

Braking Devices VB 230/ Assembly- and Commissioning Instructions

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

OnCommand Troubleshooting Guide Hayward Industries

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

altec Alta Tecnología de Vanguardia S.A. de C.V.

Subject Underhood G System Error Codes and Symptoms System or Parts affected

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Assembly- and Commissioning Instructions Braking Devices VB 230/

Technical data. WARNING! Residual voltage is present for 1 minute after disconnecting mains voltage.

Error code explanation Diagnostics...2 Error Code Chart...3 Tests Wiring diagram...6

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

Installation and Maintenancee Manual

FHC-1D user manual. Features

Softmaster MMP 1. Microprocessor controller for softening plants. Operating instructions

CB CONTROL BOARD INSTRUCTION MANUAL VERSION 1.03 DATE 30/10/2000

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0

Type 6213 EV, 6281 EV

MPS AND MPS PR¼ 16 OUTPUT DEMAND CONTROLLER PENTAIR CLEAN AIR SYSTEMS. AVS Danmark ApS Skelvej Hedehusene

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Oil-free piston compressors KK and piston vacuum pumps KV

MC 785-SC. Operating Manual (Wall and panel mounting) Type: MANUAL Number of pages: 32 Version: V2.3

FOLLOW THE ARROWS. Alspa MV1000 Variable speed drive TEL: INSTALLATION QUICK START PROGRAMMING. FIRMWARE VERSION: 1.

UPS24 application instruction

TURBOTRONIK NT 151/361

AWZ 110. AWZ 13,8V/1A/7Ah/LM

Instruction manual and installation guide Traction sheave brake TSB TSB

Installation and Operating Instructions for ROBA -takt Switch Gear Type

M u l t i P o w e r. CM MultiPower. Installation and Operating Manual

Accessories for power generation plants in Italy SMA GRID GATE

Flight Systems. Replacement for KASSEC DESCRIPTION

CHAPTER 7 ERROR MESSAGE AND TROUBLESHOOTING

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

Clamping and drive module

Horizon Troubleshooting Flowchart

INSTRUCTION MANUAL H WELDER INTERLOCK

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

Mechanical Operating Instructions

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

Transcription:

Documentation RM-BV4 Micro DP Filter control

Contents 1 Safety instructions... 3 2 Device description... 3 3 Installation... 4 4 Installation... 5 4.1 Connection of the differential pressure measuring hoses... 7 5 Settings... 7 5.1 Function in "as delivered" condition... 7 5.2 Indication and setting elements... 8 5.3 Parameter setting... 9 5.4 Parameter list... 10 6 Operating modes... 12 6.1 Standard cleaning... 12 6.2 DP-controlled cleaning... 12 6.3 Down time (down time cleaning)... 12 6.4 Forced cleaning... 12 6.5 Valve test... 12 6.6 DTC, Down Time Cleaning... 13 7 Troubleshooting... 15 8 Text messages... 16 8.1 Operating messages... 16 8.2 Additional information... 17 8.3 Alarm message... 17 9 Technical specifications... 18 Regulations VDE 0160 EN 60.439 Part 500 EN 50178 2004/108/EC Symbol explanation Important note Important warning RDN 10000662 2 24.01.2014

1 Safety instructions Improper installation of the RM-BV 4 Micro DP or associated equipment may cause the failure of the device, serious or even fatal injuries. In addition to general safety rules for equipment in industrial electrical installations, pay particular attention to the following points: - The RM-BV 4 Micro DP must only be installed by qualified persons according to the provisions of the standards IEC 364 and DIN VDE 0105 for electrical equipment. - All applicable laws, conditions, rules and regulations governing the installation of electrical equipment must be observed. - Equipment with protection rating IP00 without covers must only be configured by authorised expert staff when disconnected and whilst observing the local safety and accident prevention rules. - The RM-BV 4 Micro DP is only allowed to be operated in its specified operating range. Switch off the supply voltage before replacing the RM-BV 4 Micro DP or components connected to it. Failure to do so may cause equipment damage. 2 Device description The RM-BV 4 Micro DP is used to control 24VDC solenoid valves on filtering separators with pressure pulse cleaning. Once connected to the power supply, the filter control works automatically without further operating. RDN 10000662 3 24.01.2014

3 Installation RDN 10000662 4 24.01.2014

4 Installation Valve outputs It is possible to connect up to 4 solenoid valves featuring a rated voltage of 24 V DC to the terminals 9, 10, 11 16. Supply voltage There are separate controller models for the supply voltages 230 V AC, 110 V AC and 24 V DC. Before connecting the supply voltage, check whether the rated voltage of the controller matches with the supply voltage (see nameplate). 230 AC version 110 VAC version 24 VDC version RDN 10000662 5 24.01.2014

Alarm output The potential-free "Alarm" relay output, terminals 4 (NO), 5 (COM) and 6 (NC) is used for selfmonitoring of the RM-BV 4 Micro DP. This output is energised during trouble-free operation. Following events will cause the relay contact to drop off: Failure of the supply voltage Broken wire on one of the connected valves The differential pressure has fallen below the set p-min switch point (parameter 09). The differential pressure has exceeded the set value p Max. alarm switch point (parameter 10). Input Start / Stop The input Start / Stop for downtime cleaning (terminals 7, 8) is factory-bridged. When a contact (NC) connected to this input is opened, the set downtime cycles are started, beginning with the interval time 2. Downtime cleaning is resumed with the valve following to the last controlled valve. RDN 10000662 6 24.01.2014

4.1 Connection of the differential pressure measuring hoses Use the hoses with 4 mm internal diameter and 6mm outside diameter. Connect the connector marked with 3 stripes (black screw cap) with the raw gas side and the other connector (blue screw cap) with the clean gas side of the filter. 5 Settings 5.1 Function in "as delivered" condition Using the set control times for pulse time and pause time, all connected solenoid valves are controlled one after the other starting with a cleaning pulse. Once the last valve has been operated, the control circulation is continued with the first valve. This happens until the supply voltage is turned off. Once the supply voltage has been turned on again, a restart occurs as described above. RDN 10000662 7 24.01.2014

The input Start / Stop is factory-jumpered. The function of the input is described in chapter 4 Installation under item. If a different function is desired, the parameter setting of the RM-BV 4 Micro DP needs to be changed. For this, see section 5.2 Indication and setting elements under item 5.2 Indication and setting elements Parameterisation keys Parameter selection: Press the and keys simultaneously longer than 3 seconds. Then, select your desired parameter by short pressing on the keys (scroll up) or (scroll down). Parameter value setting: After parameter selection, by simultaneous pressing of the keys and longer than 3 seconds. Then, set your desired value by short pressing on the keys (scroll up) or (scroll down). Then, confirm the set value by simultaneous pressing the and keys longer than 3 seconds. The new value is stored. You can select further parameters for setting or checking by short pressing the or key. To return to the "Operation" mode: Press the and keys simultaneously for a short time. The program automatically returns to the "Operation" mode when no key has been pressed for 1 minutes. "Alarm" LED The LED will flash if the "Alarm" output is disabled (see chapter 4 "Installation" under ). RDN 10000662 8 24.01.2014

5.3 Parameter setting RDN 10000662 9 24.01.2014

5.4 Parameter list Parameters Display text Meaning Factory setting Setting range 01 01 Tot.Valve.no. Number of valves 4 1-4 02 02 Pulse Time Pulse time of the cleaning valves 100 ms 30-900 ms 03 03 Interval T. 1 Interval time 1 12 s 2-250 s 04 04 Down Time Cyc Downtime cycles 0 1 0 1, 1-15 05 05 Interval T. 2 Interval time 2 (pause in down time) 5 s 2-250 s 06 06 Forc. cl.time forced cleaning time 0 1 0 1, 1-24 h 07 07 Working hours delete? 08 08 Default set. load? Resets the working hour counter² to 0 h. Resets the device to the factory setting. No / yes No / yes 09 09 dp min p-min alarm switch point 700 Pa 200-2000 Pa 10 10 dp max p-max switch point 1300 Pa 0 1, 300-3000 Pa 11 11 dp min alarm p-min alarm switch point 0 1 0 1, 200-2500 Pa 12 12 dp max alarm p-max alarm switch point 2300 Pa 0 1, 1000-3500 Pa 13 13 dp Units Unit of the displayed differential pressure value 14 14 dp Switch p change-over value from interval time 1 to interval time 2 15 15 Interval T. 3 Reduced interval time in DP mode 16 16 DTC Clean.Mod " p-controlled down time" mode 17 17 dp DTC Min p Min. switch point for the down time 18 18 dp DTC Max p MAX switch point for the down time Pa Pa, mbar, mmwg, inwg 1500 Pa 500-2500 Pa 5 s 2-250 s 1 1-3 3 260 Pa 200-1000 Pa 1000 Pa 300-1200 Pa 19 19 Service Alarm Service operating hours alarm 4 25000 h 2000-25000 h 1 2 3 4 0 = function deactivated Working hours: Sum of all time periods during which cleaning was active. 1 = DTC mode 1: Down time cleaning will be started via the contact 7, 8. 2 = DTC mode 2: Down time cleaning will only be started after the fan shut-down if the differential pressure has exceeded the dp DTC Max value during operation.. 3 = DTC mode 3: Down time cleaning will be started if the differential pressure was under the (parameter 17) dp DTC Min has fallen below, after the value dp DTC Max (Parameter 18) was first exceeded. The signal at input 7, 8 is not considered. The service hour counter runs when the differential pressure P is higher than 200 Pa and the parameter 19 Service Alarm is not set to "0". RDN 10000662 10 24.01.2014

Parameters Display text Meaning Factory setting Setting range 20 20 S.Run Hours delete? Resets the service hour counter to 0 h. No / yes 21 21 Relay funct. Relay function selection 1 5 1-3 5 22 22 Test mode start? Testing of the connected valves No / yes 23 23 Language Language of display text D D, GB, F, E 5 1 = mode 1: The relay output is active when a fan alarm is present. 2 = mode 2: The relay output is active when the fan alarm and the Δp-Max alarm are active. 3 = mode 3: The relay output is active during the cleaning. RDN 10000662 11 24.01.2014

6 Operating modes 6.1 Standard cleaning For this, see the section 5.1 Function in "as delivered" condition.. 6.2 DP-controlled cleaning In "Operation" mode, the filter's current differential pressure p is displayed in the text display. Cleaning starts when the differential pressure has reached the value 10 dp max. The solenoid valves are controlled one after the other using the interval set in parameter 15. By cleaning the differential pressure drops after a certain period of time. When the differential pressure has reached the value 09 dp min, the current cleaning cycle is run up to the end. Then, the cleaning process stops. 6.3 Down time (down time cleaning) For this, see chapter 4 Installation under item 6.4 Forced cleaning A complete cleaning cycle is performed when the set forced cleaning time (parameter 06) has lapsed. 6.5 Valve test For the execution of a valve test, the parameter 22 Test mode must be set to the value yes. Then, all valves are operated one after the other for one cycle with the set pulse time (parameter 02) and an interval time of 4 seconds. After the completion of the test, the device automatically returns to the current operating mode. RDN 10000662 12 24.01.2014

6.6 DTC, Down Time Cleaning Down time cleaning is activated differently, depending on the mode selected. With the DTC mode 1, down time cleaning is started via contact 7, 8 (fan stop: Contact 7, 8 must open). With DTC mode 2, down time cleaning after deactivation of the fan is started only if the differential pressure has exceeded the value dp DTC Max (Parameter 18) during operation. Contact 7, 8 must open). RDN 10000662 13 24.01.2014

With DTC mode 3, down time cleaning is started if the differential pressure has fallen below the value dp DTC Min (Parameter 17). after the value dp DTC Min (Parameter 18) was first exceeded. The signal at input 7, 8 is not considered. RDN 10000662 14 24.01.2014

7 Troubleshooting Fault Possible causes Recommended action No display text message - No mains voltage - Check the power supply No valve activity and text message "Alarm valve #" No valve activity and text message "Cleaning stop" - Fuse in device defective - Replace fuse - System EMERGENCY-STOP - Check EMERGENCY-STOP actuated - Wiring to valves interrupted - Check cables and electrical connections - Solenoid defective - Replace coil - Cleaning stopped via the "Start / Stop" input (terminals7, 8). No downtime cleaning - Parameter 04 = 0 (downtime cycles) - No signal from the fan control present - Input Start / Stop bridge terminals 7, 8. - Set parameter 04 "Downtime cycles" to another value - Apply signal to input Start / Stop terminals 7, 8. Cleaning not effective - Interval too long - Set parameter 03 "Interval 1" to a lower value - Pressure too low - Pressure to 6... Set pressure to 8 bar (min. 5 bar) - Set parameter 03 "Interval 1" to a higher value - Valve defective - Check / replace valves - Pulse time too short - Set parameter 02 Pulse time to higher value RDN 10000662 15 24.01.2014

8 Text messages 8.1 Operating messages Display RM-BV 4 Micro+dP Version #.## Cleaning # dp #### Pa DTC Cleaning. # dp #### Pa Stand By dp #### Pa Forced cleaning# dp #### Pa Meaning After applying the voltage, the text message is displayed for approx. 1 second. The device powers up during this time and conducts a selftest. The cleaning is active. # The currently operated valve is displayed in row 1 as number 1... 4 "displayed. #### If the differential pressure sensor is connected to the filter via the measuring hoses the current differential pressure Δp of the filter will be displayed in row 2 in Pa. Cleaning is stopped via the "Start / Stop" input and the down time cleaning is active. # The currently operated valve is displayed in row 1 as number 1... 4 "displayed. #### If the differential pressure sensor is connected to the filter via the measuring hoses the current differential pressure Δp of the filter will be displayed in row 2 in Pa. Cleaning is stopped via the "Start / Stop" input and the down time cleaning is disabled or the set down time cleaning cycles are executed.. The control is in stand-by mode. #### If the differential pressure sensor is connected to the filter via the measuring hoses the current differential pressure Δp of the filter will be displayed in row 2 in Pa. The forced cleaning is active. # The currently operated valve is displayed in row 1 as number 1... 4 "displayed. #### If the differential pressure sensor is connected to the filter via the measuring hoses the current differential pressure Δp of the filter will be displayed in row 2 in Pa. RDN 10000662 16 24.01.2014

8.2 Additional information Depending on the operating status, you can display further information by short pressing the or key. If no key is pressed within one minute, the display will automatically change to the original text message. Example With enabled forced cleaning and stopped cleaning ("Start / Stop" input), the display shows the message Stand By. Once the key is shortly pressed, the messages Hours in operat. (operating hours), Working hours (working hours), Time to service (time remaining to the next filter maintenance) and Time unt.forc.cl (time remaining to the next forced cleaning) are displayed. Display Hours in operat. ##### h Working hours ##### h Time to service #### h Time unt.forc.cl ## h ## min Meaning Display of the operating hours (sum of all time periods during which the supply voltage was ON). Display of the working hours (sum of all time periods during which the cleaning was active). The time remaining to the next maintenance of the filter is displayed. Cleaning is stopped via the "Start / Stop" input and the forced cleaning is active. The time remaining to the start of the forced cleaning is displayed. 8.3 Alarm message Display Valve # Error Meaning Wire break on the indicated valve output. Alarm messages are saved. This alarm remains after the root cause for the alarm has been eliminated. You can acknowledge the alarm by shortly pressing the or key. RDN 10000662 17 24.01.2014

9 Technical specifications Item Data Terminals Supply voltage Device version 230 V AC: 1 (L), 2 (N), 3 (PE) 230 V AC + / -10 % Outputs for solenoid valves Device version 110 V AC: 110 V... 120 V AC + / -10 % 1 (L), 2 (N), 3 (PE) Device version 24 V DC: 1 (+), 2 (-) 24 V DC +10 % / -0 % 4 outputs, 24 V DC, max. 1.9 A Signal input 1 inputs 24 VDC, to be served potential-free 7, 8 Signal output p measuring range Measuring sensor Power consumption Fuse 1 relay outputs (changeover contact), potential-free Max. contact rating: 250 V AC, 10 A 50 V DC, 1,5 A / 30 V DC, 10 A (ohmic) 0 5000 Pa piezoresistive Device version 230 V AC: 0.2 A Geräte-Version 110 V AC: 0,35 A Device version 24 V DC: 1,13 A Device version 230 V AC: T 0.3 A, 250 V, 5 x 20 mm Device version 110 V AC: T 0,4 A, 250 V, 5 x 20 mm Device version 24 V DC: T 2,5 A, 250 V, 5 x 20 mm Temperature range -20 C... +60 C Protection class Housing IP66, NEMA 4 Weight Altitude approx. 950 g Max. 3000 m above sea level 9, 10 (Valve 1), 11, 12 (Valve 2), 13, 14 (Valve 3) 15, 16 (Valve 4) 4, 5, 6 Disclaimer The contents of this documentation have been verified for correctness and completeness. Nevertheless, errors can not be excluded so that we cannot guarantee the correctness of this information. Subject to alterations at any time. RDN 10000662 18 24.01.2014