Flow limiter SP/SMB9 for mounting plates

Similar documents
Flow limiter SP/SMB10 Dual flow series

Flow limiter SP/SMB13 for line installation in circulating-oil lubrication systems.

Flow limiter SP/SMB3 Flow limiter SP/SMB6

Flow limiter SP/SMB US

Flow limiter SP/SMB 8... DSK US (09.04)

SP/SMT 1 Flow Divider

UD and UC Gear pump unit

Block feeder SPVS Used in oil or grease lubrication systems

Block feeder SPVS Used in oil or grease lubrication systems

Injection oilers, micro pumps for minimal quantity metering

System description for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines

Grease Pump Units For progressive and multiline systems, manually, pneumatically or hydraulically actuated

Motor-driven pump unit GSJB

Accessories for Minimal Quantity Metering

Lubrication System CLU4

Compact Units. For fluid grease, NLGI grades 000, 00 Group MKF 0.1 or 0.2 l/min EN

Chain lubrication, accessories

Lubrication System CLU4

Flow Monitors and Sensors

Injection oilers, micro pumps

PPU, PHU Piston Pumps for progressive grease and oil systems, pneumatically or hydraulically actuated

Grease Pump Units. For progressive and multiline systems, manually, pneumatically or hydraulically actuated. Please note!

PSG product series. Modular feeder. For oil and grease For use in SKF ProFlex progressive and SKF CircOil circulating centralized lubrication systems

SKF VectoLub, VE1B units

Single-Line Centralized Lubrication Systems

Chain lubrication, accessories Nozzles, oiling-brushes, reservoirs and other accessories for the chain lubrication EN

Electric Plug-and-Socket Connectors

SKF VectoLub, accessories Accessories for the minimal quantity lubrication systems VTEC and VE1B EN

PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2

Directional Valves for oil or grease

For grease For application in SKF DuoFlex dual-line centralized lubrication systems

JM Oil Lubrication Pump SKF MultiFlex multi-line pump units for total loss oil lubrication systems on compressors

Inexpensive solution for the lubrication of linear guides and rolling bearings

Grease Lubrication Pump FK

Block metering device VPB. Block feeder for use in oil or grease lubrication systems

Manually or pneumatically actuated piston pumps

Injection Oilers, Micro Pumps

" " (495) For oil For continuous monitored lubrication with minimum quantities from 0,5 to 5 mm³/min

Piston Distributors, Metering Units

SKF Grease injection system

Manually or pneumatically actuated Piston pumps

For high-viscosity oils and fluid grease of NLGI grades 000, 00 For use in SKF MonoFlex single-line centralized lubrication systems

SKF Multilube pumping unit

Standard filter Disk filter Return filter. Lubrication systems can fail from the following

Standard filter Disk filter Return filter. Lubrication systems can fail from the following

for SKF DuoFlex dual-line lubrication systems

Single- and Multicircuit Pumps

SGA and SG-dosers. for SKF DuoFlex dual-line lubrication systems

Progressive Feeders. for progressive grease and oil systems US

PAB Atex-certified centrifugal pumps

Metering Units and Piston Distributors with Quick Connector System

PRA Centrifugal pumps

VECTOLUB Minimal Quantity Lubrication

For reliable control of small, large or multi-system-type lubrication systems

Chain lubrication, accessories

Product series DigitalSuper

Product series DSA, DSB, DSC, DSD

SKF Maxilube pumping centre. for SKF DuoFlex, dual-line lubrication systems

PS/PSL Centrifugal pumps

Air-oil centralized lubrication systems

Lubrigun lubrication unit

Grease-lubricating pump FF... DSK US (05.05)

PSR Centrifugal pumps

Axial Piston Fixed Pump A17FNO Series 10

Table of contents. Table of contents. Overview of progressive distributor Distributor bridge without outlet...

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

Air-oil centralized lubrication systems

Piston Pumps with Reservoir

DUOFLEX lubrication pumps

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPB

VGD Series VGDxx.xxxU Gas Valves for use with SKPxx.xxxU electro hydraulic actuators

Linear actuator CAR 32. Benefits. Industrial reliable and robust actuator Wide range of components Right- and left-hand version

Linear actuator CAT 32B. Benefits. Compact Robust Modular Lubricated for service life High efficiency Digital encoder feedback

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

Differential Pressure and Flow meters Accessories for the Media Series

Oil-free piston compressors KK and piston vacuum pumps KV

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPA-D

TLT. Standards. Telescopic pillar. Very small built-in dimension EN/IEC UL Powerful

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Volume flow meter with throttle- and bypass valve KUZ-L

Grease lubricating pump FB DSK US (06.02)

VLF45... Hot Air Valves. Building Technologies Division

Immersion Pumps PMS and PMS-T sealless

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Air operated chassis pump

Axial Piston Fixed Pump A17FNO

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Linear actuator CAHM-31. Benefits. Modular Robust Reliable High speed and/or high load All metal design. Picture CAHM-3130-LS0300-D1-010

Subplates (AP) and multi-station subplates

UC and UD Gear pump unit for hydraulic or circulating-oil lubrication systems

RABO Rotary Gas Meter

Elster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter FEATURES & BENEFITS. Applications. Brief information

ELADOS EMP-KKS Diaphragm Piston Pump Type

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives

2-Circuit Axial Piston Fixed Pump A18FDO

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

GVP, chain lubrication

IPVS High-pressure Internal Gear Pumps Technical Data Sheet

Special Radial piston pumps Type SRK-ATEX

Transcription:

1-3002-EN Flow limiter SP/SMB for mounting plates Advantages reliable perpetual dispensation of individual volume flows - self-adjusting metering, thus identical volume flows despite different back pressures. - wide viscosity range, virtually independent of temperature and viscosity, thus stable system conditions easy system design The required volume flow and nozzle size are determined during the engineering phase. space-saving installation thanks to a common base plate with only one inlet for up to 6 flow limiters. easy start up Pre-adjusted volume flows enable short start-up periods. effective monitoring of volume flow with gear wheel-type flow indicator, with Hall sensor wide range of operation optional ATEX version stable and reproducible measurement, no adjustment required. Flow limiters are used in large oil circulating lubrication systems. The task of a flow limiter is to divide up the volumetric flow of the main line into parallel individual volumetric flow quantities and to limit these according to requirements, or to keep them constant. The volumetric flow generated is independent of the system pressure and virtually independent of viscosity. The SP/SMB flow limiter was developed specially for mounting plates. The advantage of this design is its simple and compact construction. Using interchangeable plug-in nozzles, the volumetric flow of the flow limiter can be set stepwise from 0.08 to 8 l/min. That makes it possible to adjust the volumetric flow rates at a later date. The SP/SMB series comes with a visual/ electronic gear wheel-type flow indicator with a specific flow of 12.0 ml per revolution of the gears.

Design The SP/SMB flow limiter consists of the following: flow limiter housing (with sensor) flow limiter regulating assembly (with control piston, plug-in nozzle and pressure spring) gear pair flow limiter cover (with sight glass, seals, plugs and fastening screws) baseplate. The housing, gears and cover consist of an anodized aluminum alloy to provide corrosion-resistance and low weight. A round glass disk conforming to DIN 802 (pressed hard glass) is used for the sight-glass pane. The pane floats in the cover to avoid distortion and premature failure. The housing accommodates a sensor that is actuated by pin magnets embedded in the gear. Dimension SP/SMB 1 2 3 E1 Plug DIN 43650 See important product usage information on the back cover. 120 Mode of operation With the SP/SMB flow limiter, the total volumetric flow Q is divided up into individual flow lines Q, by the parallel layout of the volume limiter on the mounting plate. The system pressure, being the input pressure p1, is thus maintained for all flow limiters. Every flow limiter has a control piston with a plug-in nozzle as a differential pressure regulator. The differential pressure (p 1 -p 2 ) at the interchangeable plug-in nozzle D1 in the control piston is based on a balance of forces. p 1 A = p 2 A + F resp. p 1/2 = p 1 - p 2 = F/A = constant The downstream gear wheel-type low indicator uses a dynamic pulse generator (24 V DC) to emit a continuous sequence of pulses proportional to the volumetric low. The proportionality factor K1 is derived from the swallowing capacity of one revolution of the gear pair (K1 = 12.0 ml/pulse). The sequence of pulses can be displayed and monitored by pulse-monitoring equipment, group monitoring units or a central evaluation station. Selection of nozzle, cf. page 5.. Functional diagramm Flow limiter IS D2 F p2 RK D1 p1 It follows that: The difference in pressure in front of and behind variable nozzle D2 is held constant by a balance in pressure. The condition for this function is that the system pressure p1 is always greater than the sum of the pressure drops in and after each flow limiter. 1 + 2 3 - p3 ZK 1 + 2 3 - SH p 1 > p 1/2 + p 3 For this reason, the pump volume low should exceed all individual low quantities by approx. 15 %, i.e., Q = 1.15 ( Q i ). p 1 pressure upstream of plug-in nozzle D 1 p 2 pressure downstream of plug-in nozzle D 1 p 3 pressure downstream of D 2 and ZK D 1 plug-in nozzle D 2 adjustable oriice RK control piston ZK gear wheel-type low indicator SH pulse generator IS pulse monitoring and display F spring force 2 1-3002-EN

Technical Data General information Type... 2-way flow limiter valve with volumetric flow control Application...for Mounting plates Fitting positon.... any (make sure the filter is mounted in vertical position) Ambient temperature range...0 bis + 70 C Material.... AlCuPb F38, Weight....1.4 kg Hydraulics Nominal volumetric flow... stepwise from 0.0 bis 8.18 l/min (see also related tables page 5) Working pressure p 1...6 bis 50 bars Required differential pressure between input pressure p 1 and output pressure p 3... 6 bars Lubricant... mineral oils, synthetic oils and ecofriendly oils Lubricant temperature range.... 0 bis + 0 C 1 ) Operating viscosity...20 bis 600 mm²/s Gear wheel-type flow indicator Sensor....Hall sensor Power...24 V DC ± 10% Max. switched current... 20 ma Connection....plug DIN 43 650 Type of enclosure...ip 65 Proportionality factor...12.0 ml/impuls 1) Only when ambient temperature < 60 C Mounting plate for a flow limiter with interchangeable strainer Mounting plate for 1 flow limiter with interchangeable strainer 65 Material.... AlCuMgPb F38, Mesh spacing interchangeable strainer... 0.1 mm Weight.... 0.8 kg Mounting plate with interchangeable strainer Description Order no. Mounting plate for a flow limiter with interchangeable strainer 24-0714-318 Inlet expanded length 31 45 26 42 123 105 15 30 Outlet 110 Mounting plate for 1 to 6 flow limiters Mounting plate for 1 to 6 flow limiters A (81) (26) (58) Material... AlCuMgPb F38, Weight....see table 30 42 SW27 110 Mounting plates without oil filter Number Dim. A Weigt Order no. flow limiter[n] [mm] [kg/part] 1 116 0.75 24-0714-3171 2 17 1.28 24-0714-3172 3 278 1. 24-0714-3173 4 35 2.33 24-0714-3174 5 440 2.85 24-0714-3175 6 521 3.38 24-0714-3176 24 42 Ø n x 81 81 32 Oulet 15 G1/2 Inlet 1-3002-EN 3

Mounting plate for 1 to 6 flow limiters with extension for oil filter mounting Material... AlCuMgPb F38, Weight... see table Outlet A (81) (26) Mounting plate with mounted oil filter (117) 58 160 G1/2 Inlet Mounting plate with extension for oil filter mounting 1) 65 Number of Dim. A Weigt 2 ) Order no. 1) flow limiters [mm] [kg/part] 1 175 1,0 24-0714-3181 2 256 1,5 24-0714-3182 3 337 2,0 24-0714-3183 4 418 2,5 24-0714-3184 5 4 3,0 24-0714-3185 6 5 3,5 24-0714-3186 30 42 15 Ø nx 81 81 1 102 75 expanded length 24 1) Without oil fiter, must ordered separately. 2) without filter Outlet Oil filter with shut-off valve Oil filter with shutt-off valve Material... AlCuMgPb F38, Cloth... V4A Mesh spacing interchangeable straine... 0.1 mm Weight... 0.8 kg ca. 130 34,5 Inlet G 1/2 6 Oil filter with shut-off valve Description Order no. Oil filter with shut-off valve 24-0651-3041 17,5 178 SW 27 75 expanded length 6 Dummy element for spare outlets Dummy element for spare outlets Material... AlCuMgPb F38, Model... with mounting screws M8x30 and sealing rings Weight... 0.8 kg Dummy element 58 11 2 11 16 22 52 Description Order no. Dummy element 24-0711-2405 58 Screw plug G 3/8" 1) 5-0038-008 32 1) order 1 screw plug for a dummy element! 4 1-3002-EN

Table: Plug-in nozzles Nominal Spare Part volumetric 1) Index nozzle Nozzle [l/min] [Ø mm] complete Plug in nozzle D 1 0.081 050 0.50 24-0455-2574 0.115 055 0.55 24-0455-2575 0.150 060 0.60 24-0455-2576 0.207 065 0.65 24-0455-2577 0.252 070 0.70 24-0455-2578 0.20 075 0.75 24-0455-257 0.345 0 0. 24-0455-25 0.411 085 0.85 24-0455-2581 0.468 00 0.0 24-0455-2582 0.55 05 0.5 24-0455-2583 0.650 100 1.00 24-0455-2584 0.730 105 1.05 24-0455-2585 0.74 110 1.10 24-0455-2586 0.884 115 1.15 24-0455-2587 0.78 120 1.20 24-0455-2588 1.087 125 1.25 24-0455-258 1.177 130 1.30 24-0455-250 1.303 135 1.35 24-0455-251 1.425 140 1.40 24-0455-252 1.558 145 1.45 24-0455-253 1) at a service viscosity of 300 mm2/s and 20 bar differential pressure Plug-in nozzles SP/SMB Nominal Spare Part volumetric Index nozzle Nozzle [l/min] [Ø mm] complete Plug in nozzle D 1 1.67 150 1.50 24-0455-254 1.7 155 1.55 24-0455-255 1.2 160 1.60 24-0455-256 2.07 165 1.65 24-0455-257 2.21 170 1.70 24-0455-258 2.36 175 1.75 24-0455-25 2.52 1 1. 24-0455-2600 2.67 185 1.85 24-0455-2601 2. 10 1.0 24-0455-2602 2.8 15 1.5 24-0455-2603 3.16 200 2.00 24-0455-2604 3.30 205 2.05 24-0455-2605 3.43 210 2.10 24-0455-2606 3.58 215 2.15 24-0455-2607 3.7 220 2.20 24-0455-2608 3.8 225 2.25 24-0455-260 4.18 230 2.30 24-0455-2610 4.37 235 2.35 24-0455-2611 4.57 240 2.40 24-0455-2612 4. 245 2.45 24-0455-2613 5.00 250 2.50 24-0455-2614 5.1 255 2.55 24-0455-2615 5.37 260 2.60 24-0455-2616 5.55 265 2.65 24-0455-2617 5.77 270 2.70 24-0455-2618 5. 275 2.75 24-0455-261 6.22 2 2. 24-0455-2620 6.4 285 2.85 24-0455-2621 6.74 20 2.0 24-0455-2622 6.5 25 2.5 24-0455-2623 7.15 300 3.00 24-0455-2624 7.31 305 3.05 24-0455-2625 7.48 310 3.10 24-0455-2626 7.72 315 3.15 24-0455-2627 7.8 320 3.20 24-0455-2628 Note! The table values given above up to a nozzle diameter of 1.45 are based on a differential pressure of 20 bar and viscosity of 300 mm²/s. Other differential pressures or viscosities result in slightly different delivery rates. These can be determined precisely using the charts for delivery rates and correction factors for the pressure. The table values given above for nozzle diameters of 1.5 and above are valid without correction over the entire viscosity range from 150 to 600 mm²/s and differential pressures of 20 to 150 bar. See lealet 1-3028-EN Accessories/Replacement parts Order No. Group monitoring unit... 84-11-03 Group monitoring unit with electrical monitoring... 84-11-030 Flow limiter SP/SMB without nozzle, without electrical monitoring. 24-1883-3012 SP/SMB without nozzle, with electrical monitoring... 24-1883-3010 Gasket set for SP/SMB... 24-0404-2340 Socket... 17-0-033 Order No. General Interchangeable strainer... 24-1874-2104 Gasket set for Interchangeable strainer... 24-0404-2117 Oil filter with shut-off valve Filter insert... 24-0651-2200 Gasket set for filter insert... 24-0404-223 Interchangeable strainer... 24-2104-200 Gear wheel-type flow indikator Sight glass (with flange, seal and shims)... 24-0758-2113 1-3002-EN 5

Key to order codes Configuration of type designation for flow limiter SP/SMB SP/SMB/2 / ATEX Order example Flow limiter design SP/SMB and size (SP/SMB) equipped with nozzle (2), with electrical volumetric flow check (E1), nozzle size Ø 1. mm with a volume flow of 2.52 l/min (1) results in the following: Type designation: SP/SMB/2E1/1 as well as Order no.: 24-270-11 Note The flow limiter type SP/SMB is optionally available in ATEX designs: EX Zone 1 EX Zone 21 Rating designation of nozzle size Type description Index nozzle, see table on page 5 Version key 2 = outfitted with nozzle, FPM O-rings Size =volumetric flow of Q = 0.08 to 8 l/min (factory defined) (The demanded volume flow is determined by the size of the nozzle, see table of nozzles page 5) Type Flow limiter with nonadjustable orifice (nozzle) ATEX = Designation only for ATEX-version Volumetric flow control /0 = without signal transmitter E1 = with electrical monitoring (PNP technology, 24 V DC) (continuous pulse sequence, proportional to volumetric flow) with the following charactaristics: Body design with ground clamp Typeplate extended Operates only while using a disconnector unit Can be ordered with ATEX certificate Additional ATEX versions available on demand after consultation with SKF Lubrication Systems Germany GmbH. 24-270- ATEX Configuration of order no. for flow limiter SP/SMB ATEX = designation only for ATEX version Designation of nozzle size Index nozzle, see table page 5 Type designation: SP/SMB/2.. /...... Order number: 0 = without signal transmitter 1 = with electrical monitoring Material specification (factory defined) 24-270-....... 6 1-3002-EN

Example of a circulating-oil lubrication system Example of a circulating-oil lubrication system The pump (1) feeds the lubricant into the main line (2). From there the lubricant makes its way directly through the flow limiter (3) (and downstream progressive feeders (6)) as well as through the flow limiters (4) (including the downstream flow divider (5) and progressive feeders (6)) to the lube points. The electrical pulse generator built into the respective flow limiters (3) (4) checks the volumetric flow. Group monitoring units evaluate the incoming pulses (7). 6 5 6 7 4 Replacing plug-in nozzles 6 3 2 Interrupt oil feed to flow limiter above shutoff valve (at oil filter, if required). Control piston held under spring pressure! Slowly screw out stop screw (hexagonal head, WAF 12) together with washer. WARNING Burning oil hazard. Failure to slowly remove screw could result in burns. Remove control piston and pressure spring. Remove plug-in nozzle from control piston. A roughly ø 6 mm rod (never use a pointed object like, for instance, a scriber) can be used to help press it out. Press new plug-in nozzle and washer into the control piston all the way to the stop. Insert the pressure spring in the borehole. Insert new plug-in nozzle into the borehole over the pressure spring without skewing. Check to make sure the control piston moves easily by pressing it against the pressure spring. Skewing leads to malfunctions. Screw in stop screw with washer. Open the shutoff valve 1 Pump 2 Main line 3 Flow limiter with 1 outlet 4 Flow limiter with 5 outlets, link element and oil filter with shutoff valve 1 Stop screw with washer 2 Plug-in nozzle with washer 3 Control piston 4 Pressure spring 5 Basic plate 6 Flow limiter housing 6 5 4 3 2 1 5 Flow divider 6 Progressive feeders 7 Group pulse-monitoring units Replacing plug-in nozzles on flow limiter SP/SMB Note With altered nozzle-cross-section, the nozzlestatements are to be altered accordingly on the Typ plate sign. 1 1-3002-EN 7

Order No. 1-3002-EN Subject to change without notice! (11/2018) Important product usage information All products from SKF may be used only for their intended purpose as described in this brochure and in any instructions. If operating instructions are supplied with the products, they must be read and followed. Not all lubricants are suitable for use in centralized lubrication systems. SKF does offer an inspection service to test customer supplied lubricant to determine if it can be used in a centralized system. SKF lubrication systems or their components are not approved for use with gases, liquefied gases, pressurized gases in solution and fluids with a vapor pressure exceeding normal atmospheric pressure (1013 mbars) by more than 0.5 bar at their maximum permissible temperature. Hazardous materials of any kind, especially the materials classified as hazardous by European Community Directive EC 67/548/EEC, Article 2, Par. 2, may only be used to fill SKF centralized lubrication systems and components and delivered and/or distributed with the same after consulting with and receiving written approval from SKF. Additional brochures 1-3027-EN Overview brochure - Flow limiter 1-3001-EN Flow limiter SP/SMB3 6 until 38 l/min signal transmitter and proximity switch 1-3001-EN Flow limiter SP/SMB6 25 until 132 l/min signal transmitter and proximity switch 1-3028-EN Flow limiter SP/SMB8 0.08 to 8 l/min Sensor and piston detector 1-3003-EN Flow limiter SP/SMB10 0.21 to 8.15 l/min Gear wheel-type flow indicator 1-3004-EN Flow limiter SP/SMB13 6 to 38 l/min Gear wheel-type flow indicator 1-3005-EN Flow limiter SP/SMB14 25 to 132 l/min Gear wheel-type flow indicator 1-1730-EN Electrical plug-in connections SKF Lubrication Systems Germany GmbH 2. Industriestrasse 4 68766 Hockenheim Germany Tel. +4 (0)62 05 27-0 Fax +4 (0)62 05 27-101 www.skf.com/lubrication This brochure was presented by: SKF is a registered trademark of the SKF Group. SKF Group 2018 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.