Installation & Operation Manual

Similar documents
Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Reliable Electric Actuation for Industrial Control

Installation, Operation and Maintenance Instructions. HRSN2 Series

Installation Instructions

Surepowr Series 100 Installation Manual

Installation and Operating Manual

Surepowr Series Sure 150

HQ Series ¼ Turn Electric Actuator

SUREPOWR TM SERIES -SURE 24/25 FIELD INSTALLATION INSTRUCTIONS

Series 10 Actuator. Installation, Operation and Maintenance Manual

Quarter Master Series 94 Actuator

ECP3, ECP5, ECP8 Series Actuators

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

HQ Series ¼ Turn Electric Actuator

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS

Bray Series 70 Electric Actuator. Basic Product/Sales School

L J H F

Installation, Operation and Maintenance Manual

LCR Series REVERSING ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

Valve Retrofit Installation Instructions for use with Electronic Actuators

Electric Actuators Maximum in-lbs

SERIES 1000 ELECTRIC ACTUATORS

Electric Actuators Maximum in-lbs

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

CENTURA CE Series. Installation, Operation SR and Limit Maintenance Switch Method Instructions

Quarter Master Chief Series 92 Actuator

HQ-006 ¼ Turn Actuator

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Series Electric Actuators

SERIES 1000 ELECTRIC ACTUATORS

VALVCON. QX-Series ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

VALVCON ADC-SERIES ELECTRIC ACTUATOR WITH OPTIONAL BATTERY BACK-UP POWER

SERIES 70 TUNNEL DAMPER MODEL ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL

P1 Quarter Turn Actuator P4 Quarter Turn Actuator Product Overview P7 Quarter Turn Actuator PAO Spring Return Actuator LCS-K Local Control Station

OPERATION INSTRUCTONS MODEL SG 05.1 SG Quarter-Turn Actuators

MF /MS Series

AE Installation Operation & Maintenance Instructions

Installation, Maintenance and Operation Manual

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

HercuLine 2000 Series Gear Kit Replacement Instructions

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

ELECTRIC ACTUATOR Installation, Operation and Maintenance Manual

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

How to Select the RE Industrial Actuator Part Number

V4(V7)-ABFW-EPN16 Actuated Wafer type butterfly valves

Motorized Butterfly Valve Actuated Wafer type butterfly valves

Electric Actuator Installation, Operation & Maintenance Manual

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

MC-351, 421, 431, MC-4311

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Motorized Butterfly Valve

M9216 Series Electric Spring Return Actuators

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

ROM and ROMpak Range. Quarter-turn Direct Drive Electric Actuators. Established Leaders in Actuation Technology

Electric Actuator Installation, Operation & Maintenance Manual

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

Motorized Butterfly Valve

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Non-Spring Return EconoDrive Floating Actuator

I-BFV.KIT Butterfly Valve Gear Operator Replacement

Automation Selection Guide

JAMESBURY VALVCON ESR-SERIES ELECTRONIC SPRING RETURN ELECTRIC ACTUATOR

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

Commercial Actuator Selection Chart Non-Spring Return

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Damper Actuator Installation

NOAH ACTUATOR NA-SERIES MANUAL EMICO EUNHA MACHINERY INDUSTRIAL CO.,LTD.

Signet Pressure Transmitter

SAFE & SECURE ACTUATOR PRODUCT MANUAL

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Quarter Master Series 94 Actuator

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

JAMESBURY VALVCON QX-SERIES ELECTRIC ACTUATOR

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

M100F Incremental Motor Actuator R81F Interface Board

Transcription:

Installation & Operation Manual This IOM is for the following ProMation Engineering Products: P2-120N4 P2-230N4 P3-120N4 P3-230N4

This page intentionally left blank

Field Manual P2/3 HV On/Off Control ISO5211 F07 8P22 Table of Contents 2.... Product Specifications 3.... Shipping and Handling 3.... Product Mounting and Setup 3.... Installation Notes 4.... Wiring Diagram 5.... Adjusting the actuator CW position 6.... Adjusting the actuator CCW position 7.... Adjusting the actuator Auxiliary Switches 8.... Mechanical Data 9.... Mechanical Data 10... Commissioning Page 1 of 10 P2/3 HV On/Off Series

Product Specifications Actuator Specifications P2 P3 Torque lb/nm 800 lbs/90nm 1335 lbs/150nm Supply Voltage 120vac 230vac 120vac 230vac Max Inrush Current 1.8A 0.8A 1.8A 1.2A Running Current 1.0A 0.5A 1.2A 1.0A Motor Split Phase Capacitor Runtime (90 @60Hz/vdc) 15 sec 22 sec Runtime (90 O @50Hz) 17 sec 26 sec Duty Cycle 25% Motor Starts 1200 per hour Weight 26lbs/12kg Mechanical Connections ISO5211 F07 8pt 22mm Electrical Entry (2) 3/4 NPT Electrical Terminations 12-16ga Environmental Rating NEMA 4/4X Manual Override 5 Handwheel Control On/Off/Jog Actuator Case Material Aluminum Alloy, Powder coated Motor Protection 230 F/110 C Thermal F* Class *Totally Enclosed Non-Ventilated Motors Ambient Temperature Operating Range -22 F to +125 F -30 C to +52 C Introduction This document provides necessary information for set-up, calibration, testing and use of the P Series quarter-turn electric actuators stated on the cover page. Each unit is shipped from the factory with initial calibration of mechanical stops, cams and switches completed for 0-90 degree operation. However, these are general settings and serve as a starting point for proper calibration of the actuator in its real-world application. Safety Safety is a basic factor any time you maintain and operate mechanical equipment. Appropriate handling methods and proper use of tools and clothes can help prevent serious accidents -- accidents which can cause injuries to you or a fellow worker. This manual was created to enable a trained user to install, adjust and troubleshoot your ProMation actuator. Only competent and trained personnel should install, maintain and operate ProMation Actuators. Any work related to this actuator must be carried out in accordance with this manual and related codes and regulations. Local workplace health and safety rules should always be followed. Duty cycle Duty cycle is the percent of time that an actuator spends running as a fraction of the total time. Duty Cycle is directly related to heat; excessively repositioning an actuator typically results in motor overheating which can cause permanent damage and/or reduced service life. Duty cycle can be calculated as follows: (example P2 series actuator running 3 seconds ON and 30 seconds OFF) Runtime = 3s, Total time = 3s + 30s = 33s, therefore this duty cycle would be 9% (3/33) Additionally, ProMation P series actuators are designed for a maximum of 1200 starts per hour (one start every 3 seconds maximum). Page 2 of 10 P2/3 HV On/Off Series 100% 75% 50% 25% 50 F 10 C Duty cycle graph Proportional On/Off/Jog 75 F 24 C 100 F 38 C 125 F 52 C Ambient Temperature 150 F 65 C

Shipping and Handling 1. This actuator is shipped in the FULLY CW position (2 color position indicator shows CLOSE and the Reference Dimple aligns with 0 ). 2. NOTE, THIS ACTUATOR MUST HAVE WATER TIGHT EMT FITTINGS, WITH CONDUIT DRAINAGE INSTALLED AND POWER SUPPLIED TO UNIT TO KEEP THE HEATER WARM AT THE TIME OF INSTALLATION. 3. Storage: This unit should NOT be stored outside unless it is powered up and has proper conduit terminations. When NOT powered up, it should be stored in a clean, dry environment at all times. 0 = CW REFERENCE DIMPLE 1 = CCW 4. This actuator has been factory calibrated to operate between 0 degrees and 90 degrees. Most quarter-turn products will not require recalibration of these settings. If any travel adjustment is necessary, please refer to pages 5-7 for instructions. 5. The actuator CANNOT operate with a rotation greater than 95 degrees. Product Mounting and Setup 0 and 1 colored for clarity 1. Fully CLOSE the valve or damper to which the actuator is to be mounted. Keep in mind this actuator rotates CW (as viewed from above the unit) when driving CLOSED. 2. Assemble necessary linkage components and attach the actuator to the driven device. 3. Tighten mounting bolts, making sure actuator is centered on the device drive shaft. 4. Utilize the handwheel to check for unobstructed manual operation from fully CCW to fully CW positions BEFORE applying power to the unit. 5. Make the electrical connections per wiring diagram on page 4. Connect POWER and CONTROL to terminals marked 1, 2, 4, and 6. Terminals 7-12 on the switch card (430-10100) are for the (adjustable) aux switches. They are dry type Form C rated 10A @ 250vac MAX. 6. Do NOT apply power at this time. Installation Notes These actuators are designed to be used between a horizontal and upright position. Do NOT mount the assembly with the actuator top below a horizontal position. When installing conduit, use proper techniques for entry into the actuator. Use drip loops to prevent conduit condensate from entering the actuator. Mechanical travel stops are factory calibrated for 90 degree operation. These stops are NOT designed to adjust mechanical rotation by more than +/- 3 degrees, they are for positioning the handwheel only. Both NPT conduit ports MUST use proper equipment to protect the NEMA 4X integrity of the housing. The internal heater is to be used in ALL applications. Do NOT install the actuator outdoors or in humid environments unless it is powered up and the heater is functioning. Use proper wire size to prevent actuator failure (see chart on page 4 for proper wire sizing). All terminals accept 12-16AWG solid/stranded wire. Do NOT parallel wire multiple actuators together without utilizing isolation relays! If this is your intention, please contact ProMation Engineering for a multiple actuator parallel wiring diagram. Page 3 of 10 P2/3 HV On/Off Series

Wiring Diagram On/Off Control B (12") NOT OPEN* 12 430-10100 Switch Card W (12") 1 R (7") 120VAC LINE IN * CONNECTIONS OPTIONAL FIELD CONTROL DEVICE 120VAC 230VAC Neu Hot GND L2 L1 GND NEU HOT GND OPEN COM* OPEN* NOT CLOSED* CLOSED COM* CLOSED* RUN OPEN OPEN PILOT* RUN CLOSED CLOSED PILOT* 11 10 9 8 7 6 5 4 3 2 1 SW4 SW3 GND Screw 1 2 3 4 J2 AUXILIARY SWITCH (STANDARD) AUXILIARY SWITCH (STANDARD) SW2 SW1 J1 E2 HEATER E1 J3 SW4 SW3 SW2 SW1 1 Switch Stack Detail Wht 8" Capacitor Blk 8" Red 7" Wht 12" Blk 12" Capacitor 410-30100 12uF/250v W (8") M Motor 120V AC Motor 410-20100 (P2/3) ALL SWITCHES SHOWN WITH ACTUATOR IN FULL OPEN POSITION THERMAL SWITCH Direct Mount Heater 410-50100 TL25-1800 E2 B (8") E1 Field wiring and devices by others Use For: P2/3-120N4-AC Items within dotted line located inside actuator housing Wire Sizing Data Wire sizing data is provided in the table to assist in the selection of the proper wire size for ProMation P series actuators using various wire sizes over distance. Please make sure to reference the correct voltage and do not exceed the indicated length of the wire run for each model. MAX distance between Actuator and Supply (feet) Actuator P2 P3 Voltage 120VAC 230VAC 120VAC 230VAC Amps Wire Gage Wire Sizing Chart 1.8A 0.8A 1.8A 1.2A 16 722 3111 722 2074 14 1166 5026 1166 3351 12 1783 7687 1783 5125 10 3030 13068 3030 8712 8 4523 19505 4523 13003 Page 4 of 10 P2/3 HV On/Off Series

Adjusting the actuator CW position Serious Damage to the actuator will result if the motor is allowed to drive the gear train into the mechanical stop!! Remove power from this device BEFORE making any travel adjustments. This actuator has been factory calibrated to operate between 0 degrees and 90 degrees. Most quarter-turn products will not require recalibration of these settings. Proceed ONLY if adjustments are required. Loosen Mechanical Stop 1. BEFORE power is applied, use a 17mm wrench and a 5mm hex key to loosen the RIGHT SIDE mechanical stop. This is the CW stop limit adjustment. Turn the stop screw 5-6 turns CCW to allow electrical cam stop adjustment without running into the mechanical stop screw. 2. Use the manual hand wheel to position the actuator to your required CW position. This must be within +/- 3 degrees of the factory setting. Adjust Cam 1 CW Mechanical Stop 3. The lower cam is Cam 1, the CW end-of-travel adjustment. Once the actuator is at its required CW position, with POWER OFF, use a 2.5mm hex key to free up the cam set screw. Once it is free, rotate the hex key to the RIGHT 10-15 degrees to reset the switch roller arm. Then snug the set screw up against the camshaft (CW) until slight pressure is felt. Then SLOWLY rotate the hex key pushing the cam to the LEFT until you hear the click on the bottom switch indicating that correct adjustment has been achieved. Tighten the set screw. COM Cam 1 NO NC CW LIMIT SWITCH LESS CW FURTHER CW 4. Apply power to the actuator and drive CCW at least 15-20 degrees. Then drive the actuator CW until the cam stops the electrical travel. Check to be sure this is the correct CW position you require. Repeat step 3 if further adjustment is needed. Tighten Mechanical Stop 5. While holding the 17mm wrench on the RIGHT SIDE jam nut to prevent the jam nut from locking, turn the 5mm hex key CW until the end of the stop screw bottoms out against the internal stop boss. Then turn the hex key ONE FULL TURN CCW before locking that adjustment with the jam nut. This procedure assures that the actuator reaches its end of travel electrically before there is any interference from the mechanical stop. CW Mechanical Stop 6. This completes the CW position calibration. The mechanical stop screw limits handwheel operation ONLY and is NOT to be used as an electrical travel limiting device. Page 5 of 10 P2/3 HV On/Off Series

Adjusting the actuator CCW position Serious Damage to the actuator will result if the motor is allowed to drive the gear train into the mechanical stop!! Remove power from this device BEFORE making any travel adjustments. This actuator has been factory calibrated to operate between 0 degrees and 90 degrees. Most quarter-turn products will not require recalibration of these settings. Proceed ONLY if adjustments are required. CCW Mechanical Stop Loosen Mechanical Stop 1. BEFORE power is applied, use a 17mm wrench and a 5mm hex key to loosen the LEFT SIDE mechanical stop. This is the CCW stop limit adjustment. Turn the stop screw 5-6 turns CCW to allow electrical cam stop adjustment without running into the mechanical stop screw. 2. Use the manual hand wheel to position the actuator to your required CCW position. This must be within +/- 3 degrees of the factory setting. Adjust Cam 2 3. The second cam is Cam 2, the CCW end-of-travel adjustment. Once the actuator is at its required CCW position, with POWER OFF, use a 2.5mm hex key to free up the cam set screw. Once it is free, rotate the hex key to the LEFT 10-15 degrees to reset the switch roller arm. Then snug the set screw up against the camshaft (CW) until slight pressure is felt. Then SLOWLY rotate the hex key pushing the cam to the RIGHT until you hear the click on the second switch indicating that correct adjustment has been achieved. Tighten the set screw. COM Cam 2 NO FURTHER NC CCW CCW LIMIT SWITCH 6. This completes the CCW position calibration. CCW Mechanical Stop The mechanical stop screw limits handwheel operation ONLY and is NOT to be used as an electrical travel limiting device. LESS CCW 4. Apply power to the actuator and drive CW at least 15-20 degrees. Then drive the actuator CCW until the cam stops the electrical travel. Check to be sure this is the correct CCW position you require. Repeat step 3 if further adjustment is needed. Tighten Mechanical Stop 5. While holding the 17mm wrench on the LEFT SIDE jam nut to prevent the jam nut from locking, turn the 5mm hex key CW until the end of the stop screw bottoms out against the internal stop boss. Then turn the hex key ONE FULL TURN CCW before locking that adjustment with the jam nut. This procedure assures that the actuator reaches its end of travel electrically before there is any interference from the mechanical stop. Page 6 of 10 P2/3 HV On/Off Series

Adjusting the actuator Auxiliary Switches Cam 3 Adjust Cam 3 1. The THIRD cam is Cam 3, the CW auxiliary switch adjustment. Drive the actuator to its CW position. Then use a 2.5mm hex key to free up the cam set screw. Once it is free, rotate the hex key to the RIGHT 10-15 degrees to reset the switch roller arm. Then snug the set screw up against the camshaft (CW) until slight pressure is felt. Then SLOWLY rotate the hex key and cam to the LEFT until you hear the click on the third switch. Continue to rotate the cam between 3 and 5 degrees to the LEFT to make sure the auxiliary cam switch changes state before the actuator reaches its end of travel electrically. Tighten the cam set screw. Adjust Cam 4 1. The FOURTH cam is Cam 4, the CCW auxiliary switch adjustment. Drive the actuator to its CCW position. Then use a 2.5mm hex key to free up the cam set screw. Once it is free, rotate the hex key to the LEFT 10-15 degrees to reset the switch roller arm. Then snug the set screw up against the camshaft (CW) until slight pressure is felt. Then SLOWLY rotate the hex key to the RIGHT until you hear the click on the fourth switch. Continue to rotate the cam between 3 and 5 degrees to the RIGHT to make sure the auxiliary cam switch changes state before the actuator reaches its end of travel electrically. Tighten the cam set screw. Cam 4 Page 7 of 10 P2/3 HV On/Off Series

Mechanical Data 2 REV C D E F 1 Engineering Change Notice Change Date Description Name 04.25.13 Document transferred to Inventor format KHL 11.12.13 Added rounded edges on Drive Coupling Data KHL 04.15.2014 Added tolerance on drive coupling data KHL 10.07.2014 Pushed square dimension to three decimal places KHL G 04.08.2015 Added Isometric view of Drive Coupling and "Depth" tag for clarity KHL H P2/3 Series Dimensional Data 324 mm 12.8 in 229 mm 9.0 in 211 mm 8.3 in B 180 mm 7.1 in (2) 3/4" NPT EMT Entry 287 mm 11.3 in 125 mm 4.9 in 86 mm 3.4 in Add 257mm [10.1"] to allow for cover removal 90 mm 3.5 in 123 mm 4.8 in Drive Coupling Fabrication Data 30.00 mm 1.181 in +.00 22.00 mm -.13 +0.000 0.866-0.005 in (4) M8x1.25 20mm 0.8" 70 mm 2.8 in BHC A 30.00 mm 1.181 in Depth +.00 22.00 mm -.13 +0.000 0.866 - in 0.005 22 mm 0.9 in F07 ISO Flange Created: 4/25/2013 Last Checked: 4/8/2015 Finish Part No. Page 8 of 10 P2/3 HV On/Off Series Dwg. Name This Document is the property of ProMation Engineering, Inc. Distribution of this document without the written ProMation Engineering, Inc. P2_3 F07 8P22 DimData.idw

Mechanical Data P Series Exploded View (P2/3-120N4 unit is shown) Aluminum Casting NEMA 4X Protection Easily distinguishable yellow/red position indicator Heavy Duty Drive Motor Modular Control Cards Easily accessible switch & cam stacks Terminal ID# NEMA 4X Cover Seal Switch Logic Map and Switch/Cam Arrangement Switch sequencing data is provided in the table below to show the change-of-state points during the rotation of the actuator from CCW to CW and back again. The red bar shows when that terminal makes with its respective common. Switches 1 and 2 are set at the factory and should NOT be changed. The INCLUDED auxiliary switches SW3 & SW4 are for terminals 7 thru 12 and those set points may be modified if need be. When so optioned, SW5 & SW6 auxiliary switches are initially set to function the same as auxiliary switches SW3 & SW4. CW -5 0 12 11 10 9 8 7 CCW 5 85 90 95 Not Open Open Common Open Not Closed Closed Common Closed SW4 CW AUX }(Factory Set - Adj) Mechanical Stop Screws (2) } SW3 CCW AUX (Factory Set - Adj) Used by Controller } Epicyclic Gearing Aluminum Casting NEMA 4X Protection Worm Drive Clutchless Override Handwheel Page 9 of 10 P2/3 HV On/Off Series

Commissioning After completing all mounting and wiring procedures and main power is available, it is now possible to commission the actuator. 1. Utilize the handwheel to rotate the actuator and damper, valve or other connected device through its full travel from fully CW to fully CCW and back again to check for any possible interference. Do NOT utilize any mechanical advantage devices to rotate the handwheel (pipes, wrenches, extension bars, etc.). 2. Manually position the actuator to its mid-stroke position. 3. Make certain the 3 wire orange plug is fully seated on the 3-pin receptacle on the switch board. 4. Apply correct power to the unit. 4.A Measure correct power on terminals 1 (Hot / L1) & 2 (Neu / L2) on the switch board. 4.B Measure correct power on the two heater terminals on the switch board. 5. Command the field device to generate a CCW signal. The actuator rotates in a CCW direction (as viewed from above). Measure terminals 2 and 6 for correct voltage (matching that measured in step 4.A). Actuator will stop when it reaches it s fully CCW position. 6. Command the fi eld device to generate a CW signal. The actuator rotates in a CW direction (as viewed from above). Measure terminals 2 and 4 for correct voltage (matching that measured in step 4.A). Actuator will stop when it reaches it s fully CW position. 7. Generate a mid-position signal at the fi eld device to move the actuator off its full CW trip position. 8. Actuator is now commissioned and operational. Page 10 of 10 P2/3 HV On/Off Series

ProMation Engineering, Inc. 16138 Flight Path Drive Brooksville, FL 34604 Phone (352) 544-8436 Fax (352) 544-8439 www.promationei.com

Industrial Applications ProMation Engineering actuators have been installed to operate process controls such as butterfl y valves, ball valves, high performance valves, plug valves, gate valves and dampers, in a broad range of demanding industrial applications. Power Generation Water Processes Mining Oil and Gas Agriculture Chemicals Complete Support ProMation Engineering is committed to providing superior customer support for your sales, project management and installation teams. Contact us today. Full Documentation We offer complete wiring diagrams, fi eld installation manuals and set up documentation for all our products, both in printed and digital form. We regularly host customized educational webinars for our customers. RapidQuote Most quotes and estimates are generated within hours of the request. ProMation Engineering Services ProMation Engineering can provide design and technical services for OEM s, projects with customized requirements and specialized operations. ProMation Engineering follows a policy of continual product updates and enhancements. Our website is the best place to obtain the latest product documentation, including the wiring diagrams for these controllers. Visit us at www.promationei.com or use the code to link to the site. 16138 Flight Path Drive Brooksville, FL 34604 Phone (352) 544-8436 Fax (352) 544-8439 email: sales@promationei.com Use your smart phone barcode scanner app here.