Ceraliquid CPS41 and CPS41D

Similar documents
Technical Information

Ceraliquid CPS42/CPS42D/CPS43

Orbipore CPS91 and CPS91D

Orbisint CPS12/CPS12D/CPS13

Orbisint CPS11 and CPS11D

Technical Information Ceraliquid CPS41D and CPS41

Orbisint CPS11 and CPS11D

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Technical Information Cleanfit CPA472D

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Unifit CPA442. Technical Information. Process assembly For installation of 120 mm sensors in food and beverage, biotechnology and chemical industries

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

Conductivity Measuring Cells ConduMax W CLS 19

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors

Technical Information Cleanfit CPA871

ph-kompaktelektrodensystem sensopac CPA 320

Technical Information Cleanfit CPA875

Conductivity Measuring Sensor InduMax H CLS 52

Cleanfit P CPA474. Technical Information. Retractable plastic process assembly with ball valve for ph and ORP electrodes

Operating Instructions Dipfit CPA111

Technical Information Cleanfit CPA451

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

Operating Instructions Cleanfit CPA875

Operating Instructions Cleanfit CPA871

Electromagnetic Flow Monitor magphant

Dissolved Oxygen, ph, and Conductivity

SITRANS P measuring instruments for pressure

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Conductivity Measurement CLM 280

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

JUMO tecline HD ph and JUMO tecline HD Rd

Dosimag. Technical Information. Electromagnetic volume flow measuring system for filling applications

Digital ph transmitter

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Digital ph transmitter

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

SITRANS F M. Flow sensor MAG 1100 F 3/59

VersaFlow Vortex 100 Vortex Flow Meter Specifications

OPTIFLUX 6000 Technical Datasheet

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Level Limit Switch liquiphant FTL 365 / FTL 366

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Flow Measurement SITRANS F M

SIPAN 32 and 34. Controllers, Sensors and Accessories for ph, ORP, Conductivity and Dissolved Oxygen

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Pressure transducer DMU 01K Compact version

Technical Information Liquiline System CAT810

Technical Information Cleanfit Control CYC25

Flow Measurement SITRANS F M

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Explosion proof RTD assembly T15

GHMsilverline Handheld Instruments

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Analysis ph / ORP. Characteristics System. Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Proline Promag 10H, 50H, 53H, 55H

Analysis ph / ORP. Applications. Characteristics. Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Compact Pressure Transmitter DAN-HH

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

RTD Assembly TH15. Compact Instructions. KA195R/24/ae/

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

K - Flow Meter with Float

Design and application

Reliable. Safe. Cost Effective. Electronic differential pressure for level measurement with metal or ceramic sensors

Level Measurement Point level measurement - RF Capacitance switches

Diaphragm monitoring system with clamp connection For sanitary applications Model DMS-FP

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

STEEMCO-MAS Flowmeter for Steam

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

SensoLyt 700 SensoLyt 700 SW

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Mini Pressure Transmitter HA7

Pressure Transmitter Series TST Pressure Range bar, mbar, bar Output Signals ma, V

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

OPTIMASS 3000 Technical Datasheet

Inductive conductivity meter

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

Temperature Measurement Resistance thermometers

PXT-K Series. Pressure Transmitters Section 05

* * Rev. 9 01/18 Product Manual

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

TZIM. Electropneumatic Analog Positioner 10/ EN

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Metal tube variable area flowmeter for gases, liquids and steam

Transcription:

Technical Information Ceraliquid CPS and CPSD ph electrodes, analog and digital with Memosens technology With ceramic diaphragm and liquid KCl electrolyte, optional built-in temperature sensor Application Media with very low conductivities or a high percentage of organic solvents or alcohols: Food industry Biotechnology Laboratory measurements Power plants 0 With ATEX, FM and CSA approval for application in hazardous areas Your benefits Liquid KCl electrolyte enabling use at very low conductivities ( 0. µs/cm) Ceramic diaphragm with defined KCl flow Application under pressures of up to 5 psi (0 bar) with counter pressure Stable reference thanks to separate reference lead with slowly diffusing electrolyte Suitable for CIP / SIP cleaning ph membrane glass suitable for steam sterilization Four lengths available: 0, 5, 60 and 5 mm Available with built-in Pt 00, Pt 000 or NTC temperature sensor Further benefits offered by Memosens technology Maximum process safety through contactless inductive signal transmission Data safety through digital data transmission Easy handling due to storage of sensor-specific data Predictive maintenance possible thanks to registration of sensor load data TI079C//ae/0.05

Function and system design Measuring principle General properties Important properties of CPSD ph measurement The ph value is used as a unit of measurement for the acidity or alkalinity of a liquid medium. The membrane glass of the electrode supplies an electrochemical potential which is dependent upon the ph value of the medium. This potential is generated by the selective penetration of H + ions through the outer layer of the membrane. An electrochemical boundary layer with an electric potential forms at this point. An integrated Ag/AgCl reference system serves as reference electrode. The transmitter converts the measured voltage into the corresponding ph value using the Nernst equation. Application at low conductivity Thanks to its liquid KCl electrolyte filling, the electrode can be applied at very low conductivities ( 5µS/cm with one diaphram, 0. µs/cm with three diaphragms). Sterilizable The electrode can be used in applications with steam sterilization (max. 75 F / 5 C). Durability The electrode can be applied under pressures of up to 5 psi (0 bar) with counter pressure. Maximum process safety The inductive and non-contacting measured value transfer of Memosens guarantees maximum process safety and offers the following benefits: All problems caused by moisture are eliminated. The plug-in connection is free from corrosion. Measured value distortion from moisture is not possible. The plug-in system can even be connected under water. The transmitter is galvanically decoupled from the medium. The result: No more need to ask about "symmetrically high-impedance" or "unsymmetrical" or an impedance converter. The cable does not act like an antenna. Thus, EMC safety is guaranteed. Data safety through digital data transfer The Memosens technology digitizes the measured value in the sensor and transfers it to the transmitter via a contactless connection. The result: An automatic error message is generated if the sensor fails or the connection between sensor and transmitter is interrupted. The availability of the measuring point is dramatically increased by immediate error detection. The digital signals are suitable for application in hazardous areas; the integrated electronics are intrinsically safe. Easy handling Sensors with Memosens technology have integrated electronics that allow for saving calibration data and further information such as total hours of operation and operating hours at very low or very high ph values. When the sensor is mounted, the calibration data are automatically transferred to the transmitter and used to calculate the current ph value. Storing the calibration data in the sensor allows for calibration and adjustment away from the measuring point. The result: ph sensors can be calibrated unter optimum external conditions in the measuring lab. Wind and weather do neither affect the calibration quality nor the operator. The measuring point availability is dramatically increased by the quick and easy replacement of precalibrated sensors. The transmitter does not need to be installed close to the measuring point but can be placed in the control room. Maintenance intervals can be defined based on all stored sensor load data and calibration and predictive maintenance is possible. The sensor history can be documented on external data carriers and evaluation programs at any time. Thus, the current application of the sensors can be made to depend on their previous history. Communication with the transmitter Always connect the CPSD to a digital transmitter with Memosens technology. Data transmission to an analogue transmitter is not possible. Endress+Hauser

CAL ENDRESS+HAUSER LIQUISYS REL REL REL REL REL ALARM Ceraliquid CPS/CPSD Data storage of CPSD Measuring system Digital sensors are able to store the following system data in the sensor. Manufacturing data Serial number Order code Date of manufacture Calibration data Calibration date Calibrated slope at 77 F (5 C) Calibrated zero point at 77 F (5 C) Temperature offset Number of calibrations Serial number of the transmitter used for the last calibration Application data Temperature application range ph application range Date of first commissioning Maximum temperature value Operating hours at temperatures above 76 F (80 C) and F (00 C) Operating hours at very low and very high ph values (Nernst voltage below -00 mv, above +00 mv) Number of sterilizations Glass membrane impedance System data can be displayed with the Mycom S transmitter A complete measuring system comprises: CPS or CPSD ph electrode Transmitter, e.g. Liquisys M CPM/5 (for CPSD with Memosens technology) Special measuring cable, e.g. CPK9 or Memosens data cable for CPSD Immersion, flow or retractable assembly, e.g. Unifit H CPA E Measuring system for redox measurement Unifit H CPA CPS / CPSD ph electrode CPK9 special measuring cable (for electrodes with TOP68 plug-in head) / CYK0 for digital sensors Liquisys M CPM5 transmitter a000 Endress+Hauser

Input Measured variables ph value Temperature Measuring range Installation instructions " Caution! " Caution! Electrode version AB and AC (for water / wastewater): ph: to Temperature: -5 to 76 F (5 to 80 C) Electrode version BB and BC (for process applications, sterilizable) ph: 0 to Temperature: to 75 F (0 to 5 C) Please note the process operating conditions. Installation Do not install the electrode upside down. The inclination angle must be at least 5 from the horizontal. A smaller inclination angle is not permitted as such an inclination results in air cushion forming in the glass sphere. This might impair full wetting of the ph membrane with inner electrolyte. Make sure that the assembly s threaded connection for the electrode is clean and clear of any visible damage before installing the electrode. Hand tighten the electrode, lbf ft ( Nm)! (Given value only applies to installation in Endress+Hauser assemblies.) Make sure to follow the installation instructions in the operating instructions of the used assembly. A 5 5 B Electrode installation; inclination angle min. 5 from the horizontal A Permitted inclination angle B Non-permitted inclination angle a000 Ambient temperature Storage temperature " Caution! Environment Danger of frost damage Do not use the electrode at temperatures below 5 F ( 5 C). to F (0 to 50 C) Ingress protection IP 67: IP 68: IP 68: GSA and SSA plug-in heads (with closed plug-in connection) TOP68 plug-in head, autoclavable up to 75 F / 5 C (.8 ft / m water column, F / 50 C, 68 h) Memosens plug-in head (0 m/.8 ft water column, 5 C / 77 F, 5 days, M KCl) Endress+Hauser

Process temperature Process Versions AB, AC: Versions BB, BC: 5 to 76 F (-5 to 80 C) to 75 F (0 to 5 C) Process pressure 0 to 5 psi (0 to 0 bar) with counter pressure via a separate KCl vessel Mininum conductivity Electrodes with diaphragm: Electrodes with diaphragms: min. 5 µs/cm min. 0. µs/cm ph range " Caution! Versions AB, AC: Versions BB, BC: to ph 0 to ph Danger of electrode damage Do not operate the electrodes in applications outside the given specifications! KCl consumption A 8 0 0 0 0 60 80 00 KCl consumption dependent on temperature A Consumption (ml/day) B Temperature ( C) C Temperature ( F).6 psi (800 mbar) overpressure 5.8 psi 00 mbar) overpressure.5 psi (00 mbar) overpressure C 68 0 0 76 6 B a000-en A 8 C.5.9 5.8 8.7.6.5 6 0 00 00 00 600 800 000 B KCl consumption dependent on process pressure A Consumption (ml/day) B Overpressure to process (mbar) C Overpressure to process (psi) 76 F (80 C) medium temperature F (50 C)medium temperature 68 F (0 C) medium temperature a000-en Endress+Hauser 5

Mechanical construction Design, dimensions CPS 0.67 (7).6 (60) 5.9 (05) Æ.5 (80) 8.86 (5) 5 8.86 (5) 0.7 (8) 6 7 0.7 () Unifit H CPA with CPS KCl reservoir Mounting device CPS (shaft length 5 mm / 8.86") a00009-en a0000-en CPS with ESA plug-in head for CPA, temperature sensor TOP68 plug-in head, Pg.5 KCl refilling Liquid KCl electrolyte Ag/AgCl lead 5 Ceramic diaphragm 6 Pt 00 temperature sensor 7 ph glass membrane.7, 8.86 (0, 5).7, 8.86,., 6. (0, 5, 60, 5) 5 5 0.7 (8) 6 0.7 () 0.7 (8) 6 0.7 () CPS with SSA plug-in head a0000-en CPS with ESS plug-in head a00005-en SSA plug-in head, Pg.5 Hose connection for KCl refilling Liquid KCl electrolyte Ag/AgCl lead 5 Ceramic diaphragm 6 ph glass membrane ESS plug-in head, Pg.5 Hose connection for KCl refilling Liquid KCl electrolyte Ag/AgCl lead 5 Ceramic diaphragm 6 ph glass membrane 6 Endress+Hauser

Design, dimensions CPSD.97 (50).6 (60) 8.86 (5) 5 6.7, 8.86,., 6. (0, 5, 60, 5) 5 0.7 (8) 7 0.7 () 0.7 (8) 6 7 0.7 () a0000-en CPSD with Memosens plug-in head for CPA Memosens plug-in head KCl refilling Liquid KCl electrolyte Ag/AgCl lead 5 Ceramic diaphragm 6 Pt 00 temperature sensor 7 ph glass membrane a000-en CPSD with Memosens plug-in head and KCl connection Memosens plug-in head Hose connection for KCl refilling Liquid KCl electrolyte Ag/AgCl lead 5 Ceramic diaphragm 6 Pt 00 temperature sensor 7 ph glass membrane Weight 0. lb. (0. kg) Materials Electrode shaft ph membrane glasses Metal lead Diaphragm process glass types A, B Ag/AgCl ceramic diaphragm, sterilizable Process connection Pg.5 Temperature sensor CPS: Pt 00, Pt 000 CPSD: NTC Plug-in heads CPS ESA: ESS: GSA: SSA: CPSD-****A*: CPSD-****B* Threaded plug-in head Pg.5, TOP68 for electrodes with and without temperature sensor, psi (6 bar), Ex Plug-in head with hose connection for KCl refilling Pg.5, TOP68 for electrodes with and without temperature sensor, psi (6 bar), Ex Threaded plug-in head Pg.5 for electrodes without temperature sensor Plug-in head with hose connection for KCl refilling Pg.5, for electrodes without temperature sensor Memosens plug-in head for digital, contactless data transmission, psi (6 bar) Memosens plug-in head with hose connections for KCI refilling, for digital contacteless data transmission, 5 psi (0 bar) Reference system Ag /AgCl metal lead with liquid KCl, M, AgCl free Certificates and approvals Ex approval CPS (ESA, ESS) Ex approval CPSD ATEX II G EEX ia IIC T/T/T6 FM Class I Div., in combination with the Mypro CPM and Mycom S CPM5 transmitters ATEX II G EEx ia IIC T/T/T6 Endress+Hauser 7

! Note! Ex versions of digital sensors with Memosens technology are indicated by an orange-red ring in the plug-in head. Biocompatibility Biocompatibility validated according to: ISO 099-5:99 USP, current revision TÜV certificate TOP68 plug-in head Pressure resistance psi (6 bar), min. triple overpressure safety TÜV certificate Memosens plug-in head Pressure resistance psi (6 bar), min. triple overpressure safety Electromagnetic compatibility of CPSD Product structure CPS Interference emission and interference immunity complies with EN 66: 997 / A: 998 Ordering information Electrode type without temperature sensor with built-in Pt 00 (not available with GSA and SSA plug-in heads) with built-in Pt 000 (not available with GSA and SSA plug-in heads) Application range AB AC BB BC ph = to, T = 5 to 76 F (-5 to 80 C), diaphragm ph = to, T = 5 to 76 F (-5 to 80 C), diaphragms ph = 0 to, T = to 75 F (0 to 5 C), diaphragm, sterilizable ph = 0 to, T = to 75 F (0 to 5 C), diaphragms, sterilizable Shaft length 0 mm /.7" (ESS and SSA plug-in heads only) 5 mm / 8.86" 5 60 mm /.7" (ESS plug-in head only) 6 5 mm / 6.7" (ESS plug-in head only) Plug-in head ESA Plug-in head Pg.5, TOP68, psi (6 bar), Ex ESS Hose connection head Pg.5, TOP68, Ex GSA Plug-in head Pg.5, DIN coax, non Ex SSA Hose connection head Pg.5, non Ex CPS- complete order code Product structure CPSD Version 7 Basic version Application range AB ph = to, T = 5 to 76 F (-5 to 80 C), diaphragm AC ph = to, T = 5 to 76 F (-5 to 80 C), diaphragms BB ph = 0 to, T = to 75 F (0 to 5 C), diaphragm, sterilizable BC ph = 0 to, T = to 75 F (0 to 5 C), diaphragms, sterilizable Shaft length 0 mm /.7" (versions with KCl hose connection only) 5 mm / 8.86" 5 60 mm /.7" (versions with KCl hose connection only) 6 5 mm / 6.7" (versions with KCl hose connection only) Electrolyte supply A Shaft hole for KCl refilling, CPA B KCl hose connection, CPY7 Approval Non-hazardous area G ATEX II G EEx ia IIC T/T/T6 CPSD- complete order code 8 Endress+Hauser

Assemblies (Selection)! Note! Accessories In the following sections, you find the accessories available at the time of issue of this documentation. For information on accessories that are not listed here, please contact Endress+Hauser. Cleanfit P CPA7 Compact retractable stainless steel assembly for installation in tanks and pipes, manual or pneumatic operation Ordering acc. to product structure, see Technical Information (TI7C//ae) Cleanfit P CPA7 Compact retractable plastic assembly for installation in tanks or pipes, manual or pneumatic operation Ordering acc. to product structure, see Technical Information (TIC//ae) Cleanfit P CPA7 Retractable stainless steel process assembly with ball valve for a particularly safe and reliable separation of the medium from the environment Ordering acc. to product structure, see Technical Information (TIC//ae) Cleanfit P CPA7 Retractable plastic process assembly with ball valve for a particularly safe and reliable separation of the medium from the environment Ordering acc. to product structure, see Technical Information (TI5C//ae) Cleanfit H CPA75 Retractable assembly for installation in tanks and pipes under sterile conditions Ordering acc. to product structure, see Technical Information (TI0C//ae) Cleanfit P CPA7 or 7 a0005 Cleanfit P CPA7 or 7 a0007 Cleanfit H CPA75 a0008 Endress+Hauser 9

Unifit H CPA Process assembly with integrated electrolyte vessel for installation of ph/orp electrodes Ordering acc. to product structure, see Technical Information (TI06C//ae) Unifit H CPA Process assembly for the food industry, biotechnology and pharmaceutical industry, complies with EHEDG criteria and -A standard 7-0 Ordering acc. to product structure, see Technical Information (TI06C//ae) Dipfit W CPA Immersion and installation assembly for open and closed tanks Ordering acc. to product structure, see Technical Information (TIC//ae) Unifit H CPA a0006 Unifit H CPA a0006 Dipfit P CPA0 Immersion assembly for ph/orp electrodes, for demanding processes Ordering acc. to product structure, see Technical Information (TI78C//ae) Flowfit P CPA0 Flow assembly for ph/orp electrodes, for demanding processes Ordering acc. to product structure, see Technical Information (TI79C//ae) Flowfit W CPA50 Flow assembly for ph/orp measurement Ordering acc. to product structure, see Technical Information (TI0C//ae) Dipfit W CPA a0009 Dipfit P CPA0 a0000 Flowfit P CPA0 a000 Flowfit W CPA50 a000 0 Endress+Hauser

Probfit H CPA65 Retractable assembly for installation in tanks and pipes under sterile conditions Ordering acc. to product structure, see Technical Information (TI6C//ae) Ecofit CPA60 Process connection adapter and cable set for 0 mm /.7" ph electrodes with TOP68 plug-in head Ordering acc. to product structure, see Technical Information (TI6C//ae) Probfit H CPA65 a000 Ecofit CPA60 a000 Electrolyte vessel Electrolyte solutions Buffer solutions Transmitters CPY7 electrolyte vessel Reservoir for KCl electrolyte, 50 ml (5 oz) Ordering acc. to product structure, see Operating Instructions (BA 8C/07/en) KCl-electrolyte solutions for liquid filled electrodes.0 mol, T = to F (-0 to 00 C), 00 ml ( oz), order no. CPY-.0 mol, T = to F (-0 to 00 C), 000 ml (0 oz), order no. CPY-.5 mol, T = - to 66 F (-0 to 00 C), 00 ml ( oz), order no. CPY-.5 mol, T = - to 66 F (-0 to 00 C), 000 ml (0 oz), order no. CPY- Technical buffer solutions, accuracy 0.0 ph, acc. to NIST/DIN ph.0 red, 00 ml ( oz.), order no. CPY -0 ph.0 red, 000 ml (0 oz), order no. CPY - ph 7.0 green, 00 ml ( oz), order no. CPY - ph 7.0 green, 000 ml (0 oz), order no. CPY - Technical buffer solutions for single use, accuracy 0.0 ph, acc. to NIST/DIN ph.0 0 x 0 ml (0.6 oz), order no. CPY -D ph 7.0 0 x 0 ml (0.6 oz), order no. CPY -E Liquisys M CPM/5 Transmitter for ph and ORP, field or panel-mounted housing, Hart or PROFIBUS available Ordering acc. to product structure, see Technical Information (TI9C//ae) Mycom S CPM5 Transmitter for ph and ORP, one or two channel version, Ex or Non-Ex, Hart or PROFIBUS available Ordering acc. to product structure, see Technical Information (TIC//ae) Mypro CPM Two-wire transmitter for ph and ORP, Hart or PROFIBUS Ordering acc. to product structure, see Technical Information (TI7C//ae) Endress+Hauser

Measuring cables CPK9 special measuring cable For sensors with TOP68 plug-in head, for high-temperature and high-pressure applications, IP 68 Ordering acc. to product structure, see Technical Information (TI8C/07/en) CPK special measuring cable For ph/redox electrodes with GSA plug-in head Ordering acc. to product structure, see Technical Information (TI8C/07/en) CPK special measuring cable For ph/redox glass electrodes and ISFET sensors with TOP68 plug-in head Ordering acc. to product structure, see Technical Information (TI8C/07/en) CYK0 Memosens data cable For digital ph sensors with Memosens technology (CPSxxD) Ordering according to product structure, see below Certificates A G Standard, non Ex ATEX II G EEx ia IIC T6/T Cable length 0 Cable length: m / 9.8 ft 05 Cable length: 5 m / 6. ft 0 Cable length: 0 m /.8 ft 5 Cable length: 5 m / 9. ft 0 Cable length: 0 m / 65.6 ft 5 Cable length: 5 m / 8.0 ft 88... m length 89... ft length Ready-made Wire terminals! Note! CYK0- complete order code Ex versions of CYK0 are indicated by an orange-red coupling end. United States Canada Mexico Endress+Hauser, Inc. 50 Endress Place Greenwood, IN 6 Tel. 7-55-78 Sales 888-ENDRESS Service 800-6-877 fax 7-55-898 inquiry@us.endress.com www.us.endress.com Endress+Hauser Canada 075 Sutton Drive Burlington, ON L7L 5Z8 Tel. 905-68-99 800-668-99 Fax 905-68-9 www.ca.endress.com Endress+Hauser Paseo del Pedregal No. 60 Col. Jardines del Pedregal 0900, Mexico D.F. MEXICO Tel. 55-568-05 Fax. 55-568-759 TI079C//ae/0.05 005 Endress+Hauser, Inc. Endress+Hauser