INSTRUCTION MANUAL. MIXPROOF ZAW Valve GB-IST-ZAW-0312

Similar documents
By-pass valve BBZS1 - BBYS1

MIXPROOF Valve B925 - B925B

BBZP Pneumatic Valve BBZR Long Stroke Pneumatic Valve BBZT Pneumatic Valve

MIXPROOF Valve B925 - B925B

USE AND MAINTENANCE MANUAL. J-Giotto-Top GB-IST-JGIOT-0112

USE AND MAINTENANCE INSTRUCTIONS. Giotto-Top GB-IST-GIOT-0112

Instruction, Use and Maintenance Manual HIGH-PRESSURE PNEUMATIC VALVE BBZQ - BBYQ

Instruction, Use and Maintenance Manual ASEPTIC PNEUMATIC ON-OFF VALVE WITH BELLOWS

Instruction, Use and Maintenance Manual BBZS5 - BBYS5

USE AND MAINTENANCE INSTRUCTIONS. Giotto-Top GB-IST-GIOT-1113

Instruction, Use and Maintenance Manual MODULATING VALVES BBZPM - BBYPM

Instruction, Use and Maintenance Manual CONTROL UNITS J-GIOTTO TOP

Instruction, Use and Maintenance Manual CONTROL UNITS GIOTTO TOP

Instruction Manual. SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm IM70811-EN

Instruction Manual. SMP-BC Sanitary Mixproof Valve IIM70771-GB

Unique 7000 Series Valve - Standard and Reverse Acting

Instruction, Use and Maintenance Manual CONTROL UNITS GIOTTO TOP

Instruction Manual. Unique 7000 Series Aseptic - Manually Operated ESE02421-ENUS Original manual

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

Instruction Manual. Unique Single Seat Valve - Manually Operated ESE00523-EN Original manual TD TD

Instruction Manual. SMP-TO Sanitary Mixproof Tank Outlet Valve IM70785-GB

Instruction Manual. LKAP Air-Operated Valve ESE01993-EN Original manual

CPM-I-D60 Constant-Pressure Modulating Inlet Valve

Instruction Manual. Unique Single Seat Valve - Manually Operated ESE00523-EN Original manual TD TD

Instruction Manual. Alfa Laval Safety Valve ESE03058-EN Original manual

Instruction Manual. Unique 7000 Series - Long Stroke ESE00220-ENUS Original manual

Instruction Manual. Unique Single Seat Valve - Long Stroke ESE00222-EN

Instruction Manual. Unique RV-P, pneumatic regulating valve ESE02801-EN Original manual

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS RIGHT ANGLE FILTER Original Manual EN (0) 2019/02

Instruction Manual. Unique RV-ST Regulating Valve ESE02127-EN Original manual

Instruction Manual. Unique Single Seat Valve - Tank Outlet ESE00364-EN Original manual TD _2

Instruction Manual. SBV Sanitary Ball Valve ESE01782-EN Original manual TD

Instruction Manual. SBV Sanitary Ball Valve ESE01782-EN Original manual TD

SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm

Instruction Manual. Alfa Laval Safety Valve ESE03058-EN Original manual

The information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini.

Instruction Manual. Unique-TO Sanitary Mixproof Tank Outlet Valve ESE00156EN

Instruction Manual. SMP-BC Sanitary Mixproof Valve ESE02255-EN Original manual TD _1

1000-LB. MOTORCYCLE LIFT TABLE OWNER S MANUAL

Scania Used Vehicle Extended Driveline Warranty

Angle Grinder Holder

TBE-700. Operation, Safety and Maintenance Manual. Stainless Steel Weld Cleaning System. Ensitech Pty Ltd

Instruction Manual. Unique Single Seat Valve - Tank Outlet ESE00364-EN Original manual TD _2

DELHOIST DOUBLE ACTING TELESCOPIC CYLINDERS Stoney Rise Road (P.O. Box 20), Devonport, Tasmania 7310

DeZURIK 2 20" BOS BUTTERFLY VALVES

Tri-Clover Manual and Air Actuated Fractional Valves

Hydraulic Bead Breaker Kit

CRD610 Automatic Fitting Inserter

Instruction Manual. Unique Single Seat Valve - Two Step ESE00505-EN Original manual TD TD

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Owner s Manual & Safety Instructions

Manual Operated Floor Jack

Instruction Manual. MH Koltek Valve ESE01990-EN Original manual

CRD400 Fitting Inserter OPERATIONS MANUAL

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

TBM Series 3-Way Ball Valve

ИНСТРУКЦИЯ ПО УСТАНОВКЕ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ ПРЯМОЙ ФИЛЬТР INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS

Guardian HH Shaft Coupling

AL-KO OFF-ROAD PIN COUPLING USERS MANUAL

Service Letter. Ariens Company 655 W. Ryan St. Brillion, WI

EQUIPMENT Instructions. Loctite Pneumatic 300 ml Cartridge Dispenser Part Number

VSM480. Instruction Manual VARIABLE SPEED MIXER. Read instructions before operating this tool.

Operating Instructions

Instruction & Operation Manual

Guardian FBA Flywheel Coupling

Installation and Operation Manual

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

Sawhorse with Chainsaw Holder

SSLS & SSLS4-27 Series Lift Tables

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

DISC BRAKE CALIPER TOOL SET

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

16 Inch Surface Cleaner

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

A Member of the. Integrated Metering Technologies

Large Hydraulic Bead Breaker

Frekote Adjustable Spray Applicator 6 Extension Extension Extension EQUIPMENT Operation Manual

Heavy-Duty Drywall Dolly Cart

Illumifalls Patio Pond

PULSATION DAMPENERS OPERATION & MAINTENANCE MANUAL

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

CRD600 Automatic Fitting Inserter

Innovatech User Manual. Predator 2400 T H E S U R F A C E P R E P A R A T I O N S P E C I A L I S T S

Welding Clips. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

Model P-40 & Model P-25 POWER PUSHER

MINI AIR ANGLE DIE GRINDER

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

Installation, Operation, and Maintenance Manual

CSA products for waste water. Combination air valve. Mod. SCF 2

DAP-625S and DAP-875S

IMPORTANT SAFETY INFORMATION

SUNTURA SOLAR TRACKER

Guardian NV Flywheel Coupling

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Guardian FH Flywheel Coupling

MECHANICAL QUICK HITCH

Transcription:

INSTRUCTION MANUAL MIXPROOF ZAW Valve GB-IST-ZAW-0312

Index 1. Safety signs... 3 2. General safety precautions... 3 3. Receiving/Unpacking/Storage... 4 4. Installation... 5 5. Operation... 7 6. Troubleshooting... 8 7. Cleaning... 8. General maintenance... 10. Planned maintenance... 11 10. Spare parts ordering... 12 11. Disassembly of ZAW (25--100)... 13 Drawings ZAW... 16 12. Assembly of ZAW (25--100)... 18 13. Disassembly of ZAW (25--100) divert... 20 Drawings ZAW divert... 23 14. Assembly of ZAW (25--100) divert... 25 15. Parts list... 28 16. Technical data... 2 Warranty... 30 Disclaimer... 30 Foreword This instruction manual is an integral part of the valve delivery. To use the Atex valve model is obligatory to consult the appropriate manual. Always read it carefully before using the valve. Always keep it for future reference. All rights are reserved. It is forbidden to reproduce or transit any part of the instruction manual by any means, either electronic or mechanical, including photo copies, recording or any other memorisation or retrieval system for purposes other than the exclusively personal use by the purchaser without prior written permission by the manufacturer. This instruction manual is expressly intended for use by technicians. Therefore, some information which can easily be inferred by reading the text and examining the illustrations and drawings has not been further specified. The publisher is not responsible for any consequences of incorrect operations by the user. The data and information in this instruction manual are subject to modifications or updates without any further notice or obligations on the part of the manufacturer. BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 2/30

1. Safety/Caution Signs General WARNING sign, which indicates that special instructions MUST be followed to avoid serious personal injuries. General CAUTION sign, which indicates that special instructions MUST be followed to avoid damage of equipment and environment. NOTE! Indicates IMPORTANT information, which improves the understanding of the instructions. 2. General Safety Precautions ALWAYS read the technical data before installation, operation and maintenance. ALWAYS use authorised personal to install, operate and service the valve. The personal should know the valve and the instruction manual thoroughly. ONLY use the valve for the designed purpose. ALWAYS handle heavy valves carefully and use lifting tools where necessary. ALWAYS pay attention to possible loose valve parts when unpacking the delivery. ALWAYS connect air supply carefully and disconnect after use. ALWAYS connect electrical supply carefully and disconnect after use. NEVER touch moving valve parts. NEVER touch a hot valve. ALWAYS handle cleaning agents carefully. NEVER remove a valve from piping or disassemble it when the valve or piping are pressurised. We cannot be held responsible for incorrect installation, operation and maintenance! BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 3/30

3. Receiving/Unpacking/Storage A B ATTENTION! 1. UNPACK AND CHECK VALVE DELIVERY: A. Complete valve B. Instruction manual ZAW MIXPROOF ZAW MIXPROOF M8 2. IDENTIFY VALVE TYPE SUPPLIED: ZAW: Pneumatic Mixproof ZAW MIXPROOF M8 divert 3. LIFTING OF HEAVY VALVE: - Use lifting tool, if necessary. - Fix valve to lifting tool. 4. HANDLING OF LOOSE VALVE PARTS: - Avoid falling loose valve parts. - Assemble and tighten loose parts. Paking material - Opening - connections - Electrical connections (for Giotto-Top ) Safe valve protection! 5. PACKING MATERIAL: - Inspect internal of valve. - Remove material and dispose of according to current directives. 6. INSPECTION/CLAIM: - Inspect valve connections. - Document /verify damage, missing or wrong parts. - Use current claim procedure if necessary. 7. STORAGE/PROTECTION: - Avoid dust, humidity, wet areas, heat and similar. - Avoid vibration. - Min.: - 10 C - Max.: + 50 C BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 4/30

4. Installation Electrical connections Giotto top 1. Connection of air and el supply - Use authorised personnel to install/connect the valve. - Ensure correct air pressure and quality (see page 2). - Ensure correct electrical supply for Giotto-Top (see Giotto-Top instruction manual). Electrical connections Giotto top 2. DISCONNECT SUPPLIES AFTER USE: - Disconnect air supply. - Disconnect electrical supply (for Giotto-Top ). 3. MOVING VALVE PARTS: - Never stick fingers into valve ports. - Never touch moving valve shutter/stem. Damage risk! Support Support 4. AVOID VALVE OVERLOADING AND COMPENSATE FOR: - Vibration - Thermal expansion ZAW MIXPROOF ZAW MIXPROOF M8 ZAW MIXPROOF M8 DIVERT 5. CORRECT FLOW DIRECTION: If possible, have flow against valve closing direction to avoid or minimise water hammer. BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 5/30

4. Installation 6. VALVE CONNECTIONS/UNIONS: - Ensure tight connections between valve and piping. - Remember gaskets and fit correctly. - Tighten unions firmly and carefully. 7. WELDING VALVE BODY INTO PIPING: - Remove inner valve parts. - Weld body carefully into piping. - Assemble valve. - See assembly instructions. Valve dimension A (mm) A A A DN25--40 DN50 DN65 DN80 DN100 320 340 360 380 400 8. INSTALLING VALVE INTO PIPING: Ensure sufficient clearance for valve disassembly. BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 6/30

5. Funzionamento Electrical connections Giotto top 1. Connection of air and el supply - Use authorised personnel to install/connect the valve. - Ensure correct air pressure and quality (see page 2). - Ensure correct electrical supply for Giotto-Top (see Giotto-Top instruction manual). Electrical connections Giotto top 2. DISCONNECT SUPPLIES AFTER USE: - Disconnect air supply. - Disconnect electrical supply for Giotto-Top 3. MOVING VALVE PARTS: - Never stick fingers into valve ports. - Never touch moving valve shutter/stem. BURNING RISK!! ZAW MIXPROOF ZAW M8 ZAW M8 divert 4. ONLY USE VALVE FOR DESIGNED PURPOSE: ZAW: Pneumatic Mixproof 5. HOT VALVE/PIPING: - Never touch hot valve or piping, if possible. - Alternatively use protective gloves. BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 7/30

5. Operation Electrical connections Giotto-Top 6. PRE-USE CHECK VALVE BEFORE OPERATION: - Supply air to the valve. - Supply el to the valve (with Giotto top ). - Open and close the valve several times. - Check that the valve functions operate correctly and smoothly. 6. Troubleshooting Check and service actuator! 1. TROUBLESHOOTING VALVE: Always study operation and maintenance instructions carefully before troubleshooting. 2. REPLACING WORN VALVE PARTS: - See pge. 12 spare parts ordering. Check and replace gaskets! Problem Possible cause Possible remedy External leakage Internal leakage withh closed valve, caused by normal wear Worn out gasket Replace gasket External leakage Internal leakage with closed valve occurring earlier than normal wear Difficult opening and closing Too high pressure Too high temperature Aggressive fluids Too many active control Incorrect elastomer type of gaskets Incorrect positioning of actuator Incorrect operation of actuator Dirt in actuator Incorrect positioning of valve body Replace with gasket of different elastomer type Modify operation conditions Replace with gasket of different elastomer type Assemble actuator correctly Change from normally open (NO) to normally closed (NC) or vice versa Check and service actuator Disassemble and reposition valve body BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 8/30

7. Cleaning 1. CLEANING VALVE WITH CLEANING AGENTS: - Use authorised personnel to clean the valve. - Observe concentrations of cleaning agents. - Follow instructions of cleaning agent suppliers. - Always use protective goggles and gloves. Corrosion risk of stainless steel! Damage risk of elastomers!! 2. HOT VALVE/PIPING: - Never touch hot valve or piping if possible. - Alternatively use protective gloves. 3. HANDLING OF CLEANING AGENTS: - Dose cleaning agents regularly to avoid excessive concentration. - Always rinse carefully with clean water after cleaning. - Check compatibility of valve materials. - Always dispose of cleaning agents according to current directives Example of suggested CIP Step Temperature C Cip product First rinsing Atmosphere Water without chlorine or chlorids Washing 70 Soda (NaOH) at 1% Intermediate washing Atmosphere Water without chlorine or chlorids Washing 70 Nitric acid (HNO3) at 0,5% Final rinsing Atmosphere Water without chlorine or chlorids Recommended claning speed = 2 m/s BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) /30

8. General Maintenance Electrical connections Giotto-Top 1. SUPPLYING AIR AND EL TO VALVE: - Use authorised personnel to service the valve. - Ensure correct air electrical supply for Giotto-Top (see Giotto-Top instruction manual). - Ensure correct air pressure and quality (see page 2). - Always dispose of cleaning agents according to current directives. Electrical connections Giotto-Top 2. DISCONNECT SUPPLIES AFTER USE: - Disconnect air supply. - Disconnect electrical supply for Giotto-Top. 3. MOVING VALVE PARTS: - Never stick fingers into valve ports. - Never touch moving valve shutter/stem. Atmospheric pressure required! BURNING RISK!! 4. PRESSURISED VALVE/PIPING: Always release fluid pressure from valve and piping before disassembling the valve. 5. HOT VALVE/PIPING: - Never touch hot valve or piping, if possible. - Alternatively use protective gloves. BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 10/30

8. General Maintenance Wash and clean troughly 6. CLEANING OF DEPOSITS: - Wash and clean all valve parts thoroughly before disassembly and assembly! - Pay attention to possible deposits of cleaning agents and other aggressive fluids! - Always use protective goggles and gloves, if necessary. 7. REPLACING WORN VALVE PARTS: - Always use original spare parts. - See page 12 for spare parts ordering. - Dispose of worn parts according to current directives.. Planned Maintenance Planned maintenance Valve gaskets Actuator gaskets Preventive Replace after 12 months Replace after 24 months In case of leakage Replace at the end of the day Replace in case of leakage Periodical Check for correct operation and absence of leakage Record all actions taken Check for correct operation and absence of leakage Record all actions taken BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 11/30

10. Spare Parts Ordering NOTE! Please copy this page, fill it out and fax it to below address. À: BARDIANI VALVOLES S.P.A. Ufficio Ricambi Fax: +305253408 From: Valve type: Valve type: Month/Year of purchase: Shipping instructions: Quantity: Position no.: Description: Quantity: Position no.: Description: Quantity: Position no.: Description: Quantity: Position no.: Description: BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 12/30

11. Disassembly of ZAW (25--100) 7 1 33 24 1. Fix the washer (7) through 2 screw M6x10 and supply air to fitting (24). 2. Remove clamp (33) and body (1) COUNTERHOLD! 24 50 2 3. Release air pressure to air fitting (24). 4. Unscrew shutter (2) from cylinder pivot (). Counterhold the pivot with an Allen wrench. 50 106 2 70 60 14 62 5. Remove the sealing ring disc (50), remove sealing ring (60,70) and guide bushing (106). 6. Remove shutter ring (14,62). BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 13/30

11. Disassembly of ZAW (25--100) 7 1 35 34 7. Remove screws (34) and assembly (35) from the cylinder (). 18 6 7 8 8. Remove screws (8) and washer (7) and seal ring (6,1). 1 17 18 16 31 20. CYLINDER 156: Remove elastic thread (20) by rotating plug (18) until the end part of the elastic thread is visible through cylinder slot (). Pull out completely the end part by a pointed tool. 10. CYLINDER 156: Remove plug (18) in the cyilinder (). Remove the seal rings (16,1), guide bushing (17) and spring (31). 154 11 4 11.CYLINDER 156: Remove pivot/piston (11) and the spacer (154) from cylinder (). Remove seal rings (6,4) and the guide bushing (10). 10 6 1 26 12. Unscrew little valve from the body (1) and remove sealing ring (26). BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 14/30

11. Disassembly of ZAW (25--100) 268 24 248 252 267 247 246 266 265 13. Remove the valve body (268) from the cylinder (248) and remove sealing rings (24). Unscrew the plug (265) from the cylinder (248), Slide out the piston (246) and the spring (252). Remove sealing rings (267,247,266). BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 15/30

11. Disassembly of ZAW (25--100) ZAW CYL.108-130 BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 16/30

11. Disassembly of ZAW (25--100) ZAW CYL.156 BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 17/30

12. Assembly of ZAW (25--100) 268 24 248 252 267 247 246 266 265 1. Put sealing rings (24) into the cylinder (248) and assemble the body (268). Insert sealing rings (247, 267) in to the piston (246). Assemble the sealing ring (266) into the plug (265) Put the spring (252) and the piston (246) in to the cylinder (248). Screw the plug (265) on the cylinder (248). 7 1 1 26 2. Insert the sealing ring (26) in the body (1) then screw the little valve in to it. 6 7 8 3. Insert seal ring (6,1) into cylinder () and fit washer (7) and screws (8). 154 11 4 1 17 18 16 31 10 6 4. CYLINDER 156: Insert the sealing ring (6), and guide bushing (10) in the cylinder (). Position the sealing rings (4) and the spacer (154) in the pivot/piston (11) and insert into the cylinder (). 5. CYLINDER 156: Fit the spring (31) on the piston shaft (11,13). Fit the sealing rings (16,1) and the guide bushing (17) in the plug (18) and fit it in to the cylinder (). BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 18/30

12. Assembly of ZAW (25--100) 18 35 20 6. CILINDRO 156: Fit elastic thread (20) through cylinder slot () into plug (18). Rotate the plug until the elastic thread is completely inserted. 34 7. Fit assembly (35) to cylinder () with screws (34). 106 2 50 70 60 14 62 8. Insert seal rings (60,70) and the guide bushing (106) into sealing ring disc (50).. Insert the sealing ring (14,62) in to the shutter (2). COUNTERHOLD! 24 1 33 24 50 2 10. Assemble the sealing ring disc (50) insert the shutter (2) and screw it in the cylinder () counterhold with an allen wrench. 11. Supply air to fitting (24). Assemble body (1) with clamp (33). 12. Release air pressure to air fitting (24) and remove 2 M6x10 to allow assembly of the Giotto-top. BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 1/30

13. Disassembly of ZAW (25--100) divert 108 1 1 1 1. Remove clamp (1) and body (1) 2. Remove seal ring (108) from body (1). COUNTERHOLD! 270 51 4 51 3. Unscrew lower shutter (51) from cylinder pivot (). Counterhold the pivot with an Allen wrench. 4. Remove shutter ring (4,270). 7 24 42 33 5. To fix the washer (7) through 2 screw M6x10 and supply air to fitting (24). 6. Remove clamp (33) and double body (42). BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 20/30

13. Disassembly of ZAW (25--100) divert COUNTERHOLD! Aria 24 50 2 7. Release air pressure to air fitting (24). 8. Unscrew shutter (2) from cylinder pivot (). Counterhold the pivot with an Allen wrench. 50 106 2 70 60 14 62. Remove the sealing ring disc (50), remove sealing ring (60,70) and guide bushing (106). 10. Remove shutter sealing rings (14,62). 7 1 35 34 11. Remove screws (34) and assembly (35) from the cylinder (). 6 7 8 12. Remove screws (8) and washer (7) and seal ring (6,1). BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 21/30

13. Disassembly of ZAW (25--100) divert 18 1 17 18 16 31 20 13. CYLINDER 156: Remove elastic thread (20) by rotating plug (18) until the end part of the elastic thread is visible through cylinder slot (). Pull out completely the end part by a pointed tool. 14. CYLINDER 156: Remove plug (18) in the cyilinder (). Remove the seal rings (16,1), guide bushing (17) and spring (31). 154 11 4 10 26 6 42 15.CYLINDER 156: Remove pivot/piston (11) and the spacer (154) from cylinder (). Remove seal rings (6,4) and the guide bushing (10). 16. Unscrew little valve from the double body (42) and remove sealing ring (26). 268 24 248 252 267 247 246 266 265 17. Remove the valve body (268) from the cylinder (248) and remove sealing rings (24). Unscrew the plug (265) from the cylinder (248), Slide out the piston (246) and the spring (252). Remove sealing rings (267,247,266). BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 22/30

13. Disassembly of ZAW (25--100) divert ZAW CYL.108-130 DIVERT BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 23/30

13. Disassembly of ZAW (25--100) divert ZAW CYL.156 DIVERT BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 24/30

14. Assembly of ZAW (25--100) divert 268 24 248 252 267 247 246 266 265 1. Put sealing rings (24) into the cylinder (248) and assemble the body (268). Insert seling rings (247, 267) in to the piston (246). Assemble the sealing ring (266) into the plug (265) Put the spring (252) and the piston (246) in to the cylinder (248). Screw the plug (265) on the cylinder (248). 7 1 26 6 42 2. Insert the sealing ring (26) in the double body (42) then screw the little valv in to it. 154 11 7 8 3. Insert sealing rings (6,1) into cylinder () and fit washer (7) and screws (8). 1 17 18 4 10 16 31 6 4. CYLINDER 156: Insert the sealing ring (6), and guide bushing (10) in the cylinder (). Position the sealing rings (4) and the spacer (154) in the pivot/piston (11) and insert into the cylinder (). 5. CYLINDER 156: Fit the spring (31) on the piston shaft (11,13). Fit the sealing rings (16,1) and the guide bushing (17) in the plug (18) and fit it in to the cylinder (). BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 25/30

14. Assembly of ZAW (25--100) divert 18 35 6. CILINDRO 156: Fit elastic thread (20) through cylinder slot () into plug (18). Rotate the plug until the elastic thread is completely inserted. 20 34 7. Fit assembly (35) to cylinder () with screws (34). 2 106 50 70 14 60 62 8. Insert seal rings (60,70) and guide bushing (106) into sealing ring disc (50).. Insert the sealing ring (14,62) in to the shutter (2). COUNTERHOLD! 24 50 2 10. Assemble the sealing ring disc (50) insert the shutter (2) and screw it in the cylinder () counterhold with an allen wrench. 11. Supply air to fitting (24). BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 26/30

14. Assembly of ZAW (25--100) divert 33 24 42 12. Assemble body (42) with clamp (33). 13. Release air pressure to air fitting (24). 270 COUNTERHOLD! 51 4 51 14.Insert the sealing ring (270,0) in to the shutter (51). 15. Insert the shutter (51) and screw it in the cylinder () counterhold with an allen wrench. 108 1 1 1 16. Insert the saling ring (108) in the body (1). 17. Remove the screws M6x10 to allow assembly of the Giotto-Top. Assemble the body (1) with clamp (1). BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 27/30

15. Part List N Description N Description 1 Lower body 1 Clamp 2 Shutter 246 Seal ring 4 Seal ring 247 Seal ring 6 Seal ring 248 Cylinder Cylinder 24 Seal ring 10 Guide bushing 251 fitting 11 Pivot 252 Spring 12 Seal ring 265 Plug 13 Central piston 266 Seal ring 14 Seal ring 267 Seal ring 16 Seal ring 268 Body 17 Guide bushing 26 Seal ring 18 Threaded plug 270 Seal ring 1 Seal ring 20 Elastic thread 24 fitting 31 Spring 33 Clamp 34 Socket screw 35 Assembly 40 Plug 42 Double body 50 Sealing ring disc 51 Lower shutter 60 Seal ring 62 Seal ring 70 Seal ring 4 Seal ring 101 Socket screw 106 Guide bushing 108 Seal ring 154 Spacer BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 28/30

16. Technical Data Valve Specifications: Max. working pressure: 10 bar (145 psi) Min. working pressure: Full vacuum Max. product temperature: 140 C (284 F) Min. product temperature: -10 C (14 F) Material in contact with the product: AISI 316L (1.4404) Gasket in contact with the product (FDA homologation): Finish on surfaces in contact with the product: EPDM, FKM, MVQ(silicon), HNBR, PTFE (other seals avaiable upon request). Ra 0.8 µm (other types of surface finish upon request). Pneumatic Actuator Specifications: Connectors: 1/8 (BSP) Pressure: from 6 bar (87 psi) to 8 bar (116 psi) Material: AISI 304L (1.4307) Gasket Material: NBR Power Supply (Giotto-Top ) : See Giotto-Top Instruction manual PED Directive 7/23/EEC, with special reference to Annex III, Module A regarding internal production control as Conformity Assessment Procedure in force (valve sizes DN15--25 are not included in accordance with Article 3 paragraph 1.3: Valves intended for gases, liquified gases, gases dissolved under pressure, vapours and those liquids whose vapour pressure at the maximum allowable temperature is greater than 0,5 bar above normal atmospheric pressure (1013 mbar) within the following limits: For fluids in Group 1 with a DN greater than 25 Valve size DN125 only for fluids in Group 2) BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 2/30

WARRANTY 1. CONTRACTUAL WARRANTIES AND LIABILITY 1.1 Bardiani Valvole S.p.A. warrant that their products are free from defects in design, material and workmanship. Bardiani Valvole S.p.A. shall be liable should any such defects be found within 12 (twelve) months from the date of delivery of the products. 1.2 Any claim regarding defects and/or faults found in the products shall be notified in full and in writing to Bardiani Valvole S.p.A. within 8 (eight) days from the date they were found. Adequate documentation shall be provided as evidence of said defects at the time the claim is filed. 2. LIMITATION IN LIABILITY 2.1 Without prejudice to any statutory right of the Buyer, Bardiani Valvole S.p.A. shall be under no liability in respect of electric components or elastomers that are part of their products. 2.2 The Seller shall be under no liability in respect of defects/faults specified in the following points: - defects and/or faults arising from failure to follow the instructions contained in the Manual of Instruction for the Use and Maintenance of the Product as to the use and storage of the products by the Buyer; - defects and/or faults arising from fair wear and tear of the products or their parts or their components; - defects and/or faults arising from repairs or interventions of the goods carried out by unauthorized or unqualified staff; - defects and/or faults arising from misuse, accidents, negligence and abnormal working conditions caused by the Buyer. 3. WARRANTY 3.1 Bardiani Valvole S.p.A. shall, at their discretion, repair or replace the products that are acknowledged to be defective. 3.2 Should repair or replacement of the product or of its components occur, the parts returned shall become the property of Bardiani Valvole S.p.A. The relevant freight costs involved in the return of the goods or their components shall be entirely met by Bardiani Valvole S.p.A.. 3.3 Under no circumstance shall Bardiani Valvole S.p.A. be liable to indemnify immaterial or indirect damages such as damages or consequential loss, whether loss of profit, loss of business, loss of business opportunities, loss of time, loss of goodwill and damage to corporate image, etc. 3.4 The performance of repair or replacement under the above warranty shall not entail any extension of the warranty period of 12 (twelve months), such term being unconditional. 3.5 No distributor, agent or staff to Bardiani Valvole S.p.A. is entitled to make any amendment, extension or addition to the above warranty. DISCLAIMER 1. All the statements, indications and technical data listed in this document are based on technical tests carried out by Bardiani Valvole S.p.A.. However accurate and reliable, such tests do not reflect all possible circumstances under which the products may be used. It is therefore advisable that the Buyer should always ascertain the suitability of the product in its application. The Buyer will be entirely liable for all risks and damages incurred by said products. Bardiani Valvole S.p.A. are not liable for any accident, loss or damage incurred, whether they be directly or indirectly caused by the use or misuse of the products. No further guarantees other than those stated in this document shall be granted. 2. All our customers are advised to consult our technicians as well as our offices who will supply all information pertaining the technical characteristics of our products. 3. The pictures contained in this document are intended to be general representations. They are not to be intended either legally binding or detailed representations of our products. 4. The data and statements listed in this document only refer to our standard products. They do not apply in any case to any tailor-made products that might have been purchased by the customers. 5. Bardiani Valvole S.p.A. are not liable for any defects or faults resulting from the incorrect installation of their products. Such installation is to be carried out in full compliance with the instructions contained in the Manual of Instructions for the Use and Maintenance of the Product. Bardiani Valvole S.p.A. are not liable for any defects or faults resulting from the incorrect use of their products. 6. Bardiani Valvole S.p.A. are not liable for any defects or faults resulting from the incorrect transportation and/or incorrect storage and/or incorrect maintenance of their products. 7. Bardiani Valvole S.p.A. cannot accept any liability for any faults or damages deriving from mishandling of the products and/or interventions carried out by unqualified personnel. No liability is accepted for damages caused by hits, dents, carelessness, negligence or any other any acts that cannot be considered as construction faults or faults related to the materials used in production. BARDIANI VALVOLE S.P.A. - Via G. di Vittorio 50/52 43045 - FORNOVO TARO - PR - Tel.: +30525/400044 - Fax.: +30525/3408 BARDIANI reserves the right to modify without notice its products, including products already ordered. (GB-IST-ZAW-0312) 30/30