GS510SZ Tech Sheet. Balboa Instruments. System PN System Model # GS5-GS510SZ-RCA-3.0 Software Version # 43 EPN # 2765

Similar documents
WN501Z Tech Sheet MANDERASPA. Winer Spas. System PN System Model # GS5-WN501Z-RCA-3.0 Software Version # 38 EPN # 2854

MS5000E Mach 3 Hot Sheet

Part Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element

Troubleshooting & Service for GL/GS Systems. 50 Hz

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

Troubleshooting Manual

COAST SPAS TSPA-MP SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.

OnCommand Troubleshooting Guide Hayward Industries

Technical Service Manual

Table of Contents. Balboa Control Service Checklist. Topside Control Panel. System Description. Panel Messages. Wiring Checks.

GLM SERIES CONTROL Users Manual Rev:

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

Installation and Operation Manual

INSTALLATION INSTRUCTIONS

Installation Instructions & Users Manual

Flight Systems. Replacement for KASSEC DESCRIPTION

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Setup and Programming Manual

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

BL-40 UNIVERSAL CIRCUIT BOARD REPLACEMENT KIT

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

MERCURY TL. Reference Manual LM-700 Series LAUNDRY DISPENSING SYSTEM. P/N Rev. J

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

INSTALLATION INSTRUCTIONS

Voltage Configuration Information

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

Induction Power Supplies

Non-qualifi ed users should never open or remove covers, as this will expose dangerous voltage points and other serious risks.

DEEP SEA ELECTRONICS PLC

Contents. Delivering your Canadian Spa. Pre-Delivery Guide.

KEY. Gas. Air. Aspiration. High Voltage. Low Voltage. Data. Light. BWB-1 Parts Interconnect. Mixing Chamber. Nebuliser. Ignitor. Pump.

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Customer Education. HGS System operatons Description. 50-Amp Transfer Switch (Selected Circuits)

Idle Free Systems, Inc. Reference Guide System Component Information

Air-Cooled Scroll Compressor Chillers Models AGZ 010A to AGZ 034A Models AGZ 026B to AGZ 130B. Revised Electrical Data Tables.

is10 Spa-Side Remote Installation Guide (For IntelliTouch and CP3800 series systems)

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

HAN-L62 MOUNTING PLATE

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Three-Phase Soft Starters

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

Electronic Products ELECTRONIC MAINTENANCE

Single & Three-Phase Soft Starters

Table 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm.

INSTALLATION/OPERATING INSTRUCTIONS TSC

Trouble Shooting. Symptom Possible Cause Solution Power switch ON but switch Light is Off. Main power to unit Off. Switch light defective.

PAGE Both power cords must be connected & powered to operate the E-TES 120.

ALS6A100 BACKUP DISPLAY PANEL Operations and Maintenance Manual

Electric Version Hydraulic Version Motor Starter s

Application Engineering Europe

X11CA-IM MASTER MODULE

12V PROGRAMMABLE POWER OUT

an ISO 9001: 2008 Registered Company CHEVELLE OFF TEMPERATURE COLD DEFROSTER DE-ICE OFF

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

JPS VARIABLE SPEED PUMPS INSTALLATION/PROGRAMMING/ AFFINITY LAW

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

ME AGS Auto Gen Start Network System with Inverter and Remote for Coach Generators Operator s Manual

AUTOMATIC CONTROL ROLLING DOOR OPENER

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS

Feature Description. Version History

PARTS LIST. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

33 FLASH CODE 33 - TBS HIGH

Third Generation NITE Phoenix

PARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

CH. Ford Edge (with 4.2 screen)

AWUF, AWUT Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features

Harris IRT Enterprises Digital Resistance Tester Model XP

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard

PLAYDIUM Payment Door FRU Installation Guide

AC* Series Ceiling Mount Air Handlers. The last letter of the model number represents the revision level; example: AC18-00C A is AC18-00C rev. A.

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

CH. Ford Explorer (with 4.2 screen)

Sturdy Truck Body Poultry Shipping Truck - Operations Manual August 2003

ME-AGS-S. Automatic Generator Start For Standalone Systems. Owner s Manual

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Inlet Controller SB3500 USER'S MANUAL

3P Rainforce 350H. Installation & Operating Manual

Par ts Manual Z-45/25 TM Z-45/25J. Par ts and Service Supplement. Positive Air Shutdown Valve. Serial Number Range

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

CRAGG RAILCHARGER Instruction Manual for 20SMC-12V 20SMC-24V 40SMC-12V 40SMC-24V 60SMC-12V 80SMC-12V

B. Ford Fusion 2013-up* *Visit metraonline.com for up-to-date vehicle specific applications.

an ISO 9001:2008 Registered Company 1963 IMPALA CONTROL PANEL CONVERSION KIT REV D 4/13/15, 1963 IMPALA CNTRL PNL INST PG 1 OF 16

eapu Reference Guide System Component Information (For serial numbers starting with 37)

Pontiac GTO without Factory Air Control Panel Conversion Kit (473166)

Fan Coil Thermostat. Specification & Installation instructions TFC54F3X1. Technical Data

Operation Manual. Select/DMX 4Bank

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Multi-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor

Transcription:

GS50SZ Tech Sheet Instruments System P 557-0 System Model # GS5-GS50SZ-RCA-.0 Software Version # EP # 765 Base PCBA - P 558-0 PCB GS500Z - P 05 Rev B Base Panels VL700S P 58 VL70S (Serial Standard) P 589-0 VL70S P 565 Template used: 0599_M.pdf 0/6/008 557-0_97_B.pdf 05/0/008 Page 557-0_97_B

System Revision History System P EP Date Requested By Changes Made 557 780 08.0.006 n/a 557-0 765 0.07.008 Software update to v 557-0 n/a 05.0.008 Main PCB update to rev B Page 557-0_97_B

Basic System Features and Functions Power Requirements Requires PCB Rev B. System Outputs Setup (As Manufactured) (Stereo) Optional Devices Additional Options J J J0 JA JA U J7 J9 J8 0 J7 J8 J J Page J EXT RLY AUX F SE A SE B VAC J 557-0_97_B

G C Basic System Features and Functions Any time you change a DIP Switch, other than A, you must reset Persistent Memory for your new DIP Switch Settings changes to take effect. If you do not reset Persistent Memory, your system may function improperly. To reset Persistent Memory: Power down by disconnecting power source from spa. Put a jumper across J, covering both pins. (See illustration below) Power up by connecting power source to spa. Wait until is displayed on your panel. Power down again. Remove jumper from J (May also move to cover pin only) Power up again. About Persistent Memory and Time of Day Retention: This system uses memory that doesn t require a battery to store a variety of settings. What we refer to as Persistent Memory stores the filter settings, the set temperature, and the heat mode. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to :00 PM when power is restored. Power Up Display Sequence Upon power up, you should see the following on the display: Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, which should match the version of your system. For example, if these three numbers are, that is a VS5SZ at version 8. Displayed next is: (indicating the system is configured for a heater between and 6 kw) or (indicating the system is configured for a heater effectively* between and kw). should appear for all VS models running at 0VAC. should appear for all VS models running at 0VAC, as well as all GS models. (*A heater which is rated at kw at 0VAC will function as a kw heater at 0VAC.) will appear to signal the start of Priming Mode. At this point, the power up sequence is complete. Refer to the Reference Card for the VS or GS System model of your spa for information about how the spa operates from this point on, including how to adjust the Time of Day if using a Serial Deluxe style panel. J K6 F FUSE.A 50V J K W SWITCHBAK TA K K F W J7/6 S TST FUSE 0A 50V W7 K9 J J J 0 J J7 J8 S TST EXT. AUX. F RLY SE. A SE. B J7 W W JA JA J9 K5 U J J0 F J0 FUSE A 50V J8 J BALBOA ISTRUMETS, IC. -SPD J VS500Z EXT RLY P/ 97 REV D VAC MADE I U.S.A COPYRIGHT 005 J on VS5xxZ and VS00 Series Main Board Shown. J on GS5xxZ Series is located in approximately the same position. LIE BLK AC W K K VS00 P/ 96_B MADE I U.S.A. 006 PUMP T0.5A 50V J F HEATER OZOE J9 WHT AC K J9 K K5 EUTRAL TST RST J F S TST RST J J on VS00/GS00 Series Main Board Shown. F5, FA 50V J J J7 SE. A J8 SE. B J8 U J0 J Page 557-0_97_B

Wiring Configuration and DIP Settings Setup (As Manufactured) (Stereo) VL70S Main Panel HIPot Testing ote: Disconnect slip terminal with green wires from prior to performing HiPot test. Failure to disconnect may cause a false failure of the test. Reconnect terminal to after successful completion of HiPot test. J5 J5 F6, T0A 80V J5 J TB J7 Audio Visual Circ Pump F, T0.A 50V J9 OZOE PUMP Ozone J -Spd -Spd P K9 T K6 K Blower J7/6 OPT. BLWR/PUMP 0VAC J7 F0A 50V K5 C9 FA 50V J0 Spa Light F J7 0VAC J8 J J JA JA K F J W BALBOA ISTRUMETS, IC GS500Z COPYRIGHT 007 MADE I U.S.A. P/ 05_B W Heater rated @ 0V J must be Jumpered HTR J0 HTR 00.0 kw K K F S J TST J0 0 EXT RLY J7 J8 J AUX F SE A SE B J VAC U J.0kW J J9 J8 GS5xxSZ mode K R B W G -Spd P J J W WARIG: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARIG: Persistent Memory (J) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) SSID # 00 65 A, Test Mode OFF A, See Table A, Exp Pump Disabled Enabled A5, -speed P Panel Button Assignments =Mode 5=Pump =Temp Up 6=Unused 6=Exp Pump =Temp Down 7=Unused 7=J7/6 =Light 7 A6, 50 Hz A7, J7/6 Disabled Enabled A8, Degrees C A9, on-circ Mode A0, See Table Panel Button Positions 5 6 5 6.0kW Heater J Page 5 GS500/50/50SZ Software J J Memory Reset 5 7 6 Wiring Color Key eutral (Common) AC Connections Special AC Connections Line AC Connections 0 Volt Connections Relay Control Wires Board Connector Key Typically Line voltage Typically Line voltage for -speed pumps eutral (Common) Ground ote flat sides in connector 557-0_97_B

DIP Switches and Jumpers Definitions SSID 00 65 DIP Switch Key A Test Mode (normally OFF) A+A0 Control amp draw requirements (See Table ) A O position: Expander Board Enabled for -speed Pump only.* OFF position: Expander Board Disabled. A Aux Freeze (must be OFF) A5+A9 Pump speeds and Circ Modes: A5 A9 Circ Mode Pump Speed OFF OFF on-circ -speed O OFF Circ "acts like Pump low" (filters/polls/ect) -speed OFF O hours with F shut-off -speed O O hours with F shut-off -speed A6 O position: 50Hz operation OFF position: 60Hz operation A7 O position: J7/6 Enabled for Blower or -speed Pump.* OFF position: J7/6 Disabled A8 O position: temperature is displayed in degrees Celsius OFF position: temperature is displayed in degrees Fahrenheit * Panel with button layout is not compatible when both A and A7 are O. Base Model GS500SZ-GS50SZ-GS50SZ Table # of Hi-Speed Pumps/Blower Before Heat Disabled A A0 OFF OFF 0 O OFF OFF O O O Jumper Key J If using kw or higher wattage heater, jumper can be set in either position, but may perform better on Pins and. If using.5kw or lower wattage heater, jumper must be set on Pin only. J Factory set. DO OT MOVE. Jumper must be on Pins and for GS5xZ/GS5xZ/GS5xxSZ/GS5xxDZ software. Jumper must be on Pins and for GS50xZ software. J When jumper is placed on pins during power-up, system will reset persistent memory. Leave on pin only to enable persistent memory feature. WARIG: Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. Contact if you require additional configuration pages added to this tech sheet. Panel Button Positions Aux Panel Information 7 7 Supports -button aux panel 5 6 5 6 VX0 5 6 6 5 Supports -button aux panel =Mode =Temp Up =Temp Down =Light 5=Pump Panel Button Assignments A7: OFF A7: O A: OFF A:O 6=Unused 7=Unused 6=Exp Pump 7=Unused 6=J7/6 7=Unused 6=Exp Pump 7=J7/6 VX0S 5 6 7 Page 6 557-0_97_B

AS MAUFACTURED L Electrical Service Configuration Options Systems with PCB Rev B Only F J J9 J K6 K OZOE PUMP K9 F0A 50V J5 J5 F6, T0A 80V FA 50V K5 J0 J5 C9 J ( x 6 Amp or x Amp) F TB 0VAC J7/6 J7 Wires ( Line + eutral + Protective Earth) F, T0.A 50V OPT. BLWR/PUMP J7 T BALBOA ISTRUMETS, IC. GS500Z COPYRIGHT 007 Pb MADE I U.S.A. P/ 05_B W J7 J8 HTR J0 HTR 00 W K K K Single Service, T and TT Electrical Systems JA J This option is configured J and shipped as the default. Protective Earth wire (Green/Yellow) must be connected to system ground terminal as marked. JA All equipment (pumps, blower, and heater) runs on J8 service line L. J J0 U F J9 S J 0 J7 J8 J For x 6 Amp Service: TST EXT RLY AUX F SE A SE B VAC J DIP Switch A0 must be O. Systems using only DIP switch (A0) for heat disable: J For x Amp Service: Set DIP Switch A0 such that total system amperage draw never exceeds rated service input. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set the switches shown in Table such that total system amperage draw never exceeds rated service input. 0VAC OPTIOAL L L J5 J5 F6, T0A 80V J5 J BALBOA ISTRUMETS, IC. GS500Z COPYRIGHT 007 MADE I U.S.A. P/ 05_B Pb TB W J7 G G F, T0.A 50V J8 HTR J0 HTR 00 J9 J OZOE PUMP W K K K K9 T K6 K Dual Service, T and K5TT J0Electrical Systems C9 F 0VAC 5 Wires ( J7/6Lines J7+ eutrals + Protective Earth) OPT. BLWR/PUMP J7 J JA JA The heater runs on J service line L, while all other ( x 6 Amp) J8 J J0 U Completely remove the white wire from and J. F J9 S ote: J and J5 are electrically J identical. The white 0 J7 J8 J wire may be attached to either terminal before removal. TST EXT RLY AUX F SE A SE B VAC J J F0A 50V FA 50V Protective Earth wire (Green/Yellow) must be connected to system ground terminal as marked. equipment, such as pumps and blowers, run on service line L. 0VAC F J Systems using only DIP switch (A0) for heat disable: DIP Switch A0 must be OFF. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set both switches shown in Table to O positions. Page 7 557-0_97_B

AS MAUFACTURED L L Electrical Service Configuration Options Systems with PCB Rev B Only J9 OZOE J PUMP K9 K6 K J5 J5 F6, T0A 80V J5 J BALBOA ISTRUMETS, IC. GS500Z COPYRIGHT 007 MADE I U.S.A. P/ 05_B Pb TB W J7 G F, T0.A 50V J8 HTR J0 HTR 00 W K K K K5 J0 C9 Line - Line voltage is 0VAC ( x 6 Amp or x Amp) F 0VAC Wires ( J7/6Lines J7 + Protective Earth) OPT. BLWR/PUMP J7 T J JA JA J All equipment (pumps, blower, and heater) runs on J8 J J0 Systems using only DIP switch (A0) for heat disable: U F S J DIP Switch A0 0 must J7 be J8 O. J J F0A 50V FA 50V Single Service, IT Electrical System (o eutral) Protective Earth wire (Green/Yellow) must be connected to system ground terminal as marked. service line L with L acting as the return. For x 6 Amp Service: For x Amp Service: TST EXT RLY AUX F SE A SE B VAC J Set DIP Switch A0 such that total system amperage draw never exceeds rated service input. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set the switches shown in Table such that total system amperage draw never exceeds rated service input. 0VAC J9 F J OPTIOAL L L L J5 J5 F6, T0A 80V J5 J BALBOA ISTRUMETS, IC. GS500Z COPYRIGHT 007 Pb MADE I U.S.A. P/ 05_B TB W J7 G G J8 Line - Cap (Insulate) end, Do not connect. F, T0.A 50V HTR J0 HTR 00 J9 J OZOE PUMP W K K K K9 T K6 K K5 J0 C9 Line - Line voltage is 0VAC F 0VAC Wires ( J7/6Lines J7 + Protective Earth) OPT. BLWR/PUMP J7 J JA JA J All equipment (pumps, blower, and heater) runs on J8 J J0 Systems using only DIP switch (A0) for heat disable: U F S J DIP Switch A0 0 must J7 be J8 O. J J F0A 50V FA 50V -Phase Service, IT Electrical System (o eutral) Protective Earth wire (Green/Yellow) must be connected to system ground terminal as marked. service line L with L acting as the return. For x 6 Amp Service: For x Amp Service: TST EXT RLY AUX F SE A SE B VAC J Set DIP Switch A0 such that total system amperage draw never exceeds rated service input. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set the switches shown in Table such that total system amperage draw never exceeds rated service input. 0VAC J9 F J OTE: ot all GS5xxZ systems can support -Phase. -Phase requires System PCB Rev B. If using an expansion board, the board must have fuse-protection. Page 8 557-0_97_B

Ozone Connections ote: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Account Manager for information on purchasing a pin-removal tool. Ozone connector configuration for 0VAC 50Hz: Black or Brown Line Conductor Empty White or Blue eutral Conductor Empty L Flat sides of sockets as shown J5 J5 F6, T0A 80V J5 J TB J7 Audio G W Visual B R Circ G W Pump B R F, T0.A 50V J9 OZOE PUMP J G W B R -Spd P Line - Black or Brown conductor ot used eutral - White or Blue conducto ot used J8 W Page 9 557-0_97_B

Serial Standard Panel Configurations VL700S P 58 with Overlay P 688 Connects to Main Board terminal J only* Blower Mode Warm Heat SETUP Jets Jets Light VL70S (Serial Standard) P 589-0 with Overlay P 00 Connects to Main Board terminal J only* Cool Blower Mode Warm Heat Jets Jets Light Cool VL70S P 565 with Overlay P 790 Connects to Main Board terminal J only* * Panels with back-lighting (bulbs installed) should never be plugged into J. Use J only. If the backlight bulbs are removed, then both J and J may be used. Page 0 557-0_97_B