Research of the alternator on the stand efficiency aspect

Similar documents
Registration of the diagnostic signals of the starting system for selected faults

Energy balance in motor vehicles

Design of pneumatic proportional flow valve type 5/3

Scroll Compressor Oil Pump Analysis

The analysis of the accuracy of the wheel alignment inspection method on the side-slip plate stand

Comparative study between double wish-bone and macpherson suspension system

Effect of plus sizing on driving comfort and safety of users

Control and operating conditions and hydrokinetic converter slip in the vehicle s transmission system

Implementation of telecontrol of solar home system based on Arduino via smartphone

Synchronous Generators I. Spring 2013

Researches regarding a pressure pulse generator as a segment of model for a weighing in motion system

The influence of thermal regime on gasoline direct injection engine performance and emissions

Plasma technology for increase of operating high pressure fuel pump diesel engines

Impact of air conditioning system operation on increasing gases emissions from automobile

Synchronous Generators I. EE 340 Spring 2011

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

COMPARISON OF ENERGY EFFICIENCY DETERMINATION METHODS FOR THE INDUCTION MOTORS

The test bench for testing torsional stiffness of active anti-roll bar made of extended profiles with rectangular cross-section

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad

The Modeling and Simulation of DC Traction Power Supply Network for Urban Rail Transit Based on Simulink

A starting method of ship electric propulsion permanent magnet synchronous motor

Development of the automated bunker door by using a microcontrollersystem

Stanley-Adamson: The First Industrial Size Variable Speed Compact Hydro Project Worldwide

A conceptual design of main components sizing for UMT PHEV powertrain

Design and Analysis of Hydraulic Chassis with Obstacle Avoidance Function

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors

Core Loss Effects on Electrical Steel Sheet of Wound Rotor Synchronous Motor for Integrated Starter Generator

A Comprehensive Study on Speed Control of DC Motor with Field and Armature Control R.Soundara Rajan Dy. General Manager, Bharat Dynamics Limited

Renewable Energy Systems 13

Study concerning the loads over driver's chests in car crashes with cars of the same or different generation

Design and dimensions calculation of Inductive Rheostat as a Control Element of Synchronization Systems

CHAPTER 5 ANALYSIS OF COGGING TORQUE

Voltage Generation of Three-Phase Double Sided Internal Stator Axial Flux Permanent Magnet (AFPM) Generator

Failure Modes and Effects Analysis for Domestic Electric Energy Meter Using In-Service Data

Simulation evaluation of capacitor bank impact on increasing supply current for alumunium production

ISSN: X Tikrit Journal of Engineering Sciences available online at:

Design of Control System for Vertical Injection Moulding Machine Based on PLC

CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS

Page 1. Design meeting 18/03/2008. By Mohamed KOUJILI

Combined hydraulic power vehicle transmission modes

Doubly fed electric machine

Research of the pre-launch powered lubrication device of major parts of the engine D-240

Note 8. Electric Actuators

Steering Dynamics of Tilting Narrow Track Vehicle with Passive Front Wheel Design

Asynchronous slip-ring motor synchronized with permanent magnets

Bench tests results of the traction parameters of the light two-wheeled electric vehicle

Available online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering

SINGLE-PHASE LINE START PERMANENT MAGNET SYNCHRONOUS MOTOR WITH SKEWED STATOR*

Lab 6: Wind Turbine Generators

VARIABLE FREQUENCY DRIVE AND ITS INDUSTRIAL APPLICATIONS

Transient analysis of a new outer-rotor permanent-magnet brushless DC drive using circuit-field-torque coupled timestepping finite-element method

Design Analysis of a Dual Rotor Permanent Magnet Machine driven Electric Vehicle

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Development of High-Efficiency Permanent Magnet Synchronous Generator for Motorcycle Application

Development of Dynamic Calibration Machine for Pressure Transducers

Vibration damage mechanism analysis on rotor of diesel generating set with rigid coupling

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

Evaluation of phase separator number in hydrodesulfurization (HDS) unit

EVS25. Shenzhen, China, Nov 5-9, 2010

Just what is an alternator?

Effect of phase advance on the brushless dc motor torque speed respond

Permanent Magnet DC Motor Operating as a Generator

DsPIC Based Power Assisted Steering Using Brushless Direct Current Motor

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

International Journal of Advance Research in Engineering, Science & Technology

Department of Electrical Power Engineering, Universiti Tun Hussein Onn Malaysia, Locked Bag 101, Batu Pahat, Johor, Malaysia

Mechatronics Chapter 10 Actuators 10-3

Electrical Machines II. Week 5-6: Induction Motor Construction, theory of operation, rotating magnetic field and equivalent circuit

Analysis of thermal stress of the piston during nonstationary heat flow in a turbocharged Diesel engine

Comparative Performance of FE-FSM, PM-FSM and HE-FSM with Segmental Rotor Hassan Ali Soomro a, Erwan Sulaiman b and Faisal Khan c

Unit 32 Three-Phase Alternators

Lab Electrical Power Engineering I

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Armature Reaction and Saturation Effect

Development of High-Speed AC Servo Motor

The Effects of Magnetic Circuit Geometry on Torque Generation of 8/14 Switched Reluctance Machine

Mathematical Modeling and Simulation of Switched Reluctance Motor

A Practical Guide to Free Energy Devices

Influence of motorcycles lane to the traffic volume and travel speed in Denpasar, Indonesia

Physical Modelling of Mine Blast Impact on Armoured Vehicles

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Synchronous Motor Drives

SIMULINK Based Model for Determination of Different Design Parameters of a Three Phase Delta Connected Squirrel Cage Induction Motor

Modeling and Simulation of A Bldc Motor By Using Matlab/Simulation Tool

IMPACT OF SKIN EFFECT FOR THE DESIGN OF A SQUIRREL CAGE INDUCTION MOTOR ON ITS STARTING PERFORMANCES

Comprehensive Technical Training

Motors for tram drives

Volume II, Issue VII, July 2013 IJLTEMAS ISSN

The use of ECDIS equipment to achieve an optimum value for energy efficiency operation index

Design and Analysis of Novel Bearingless Permanent Magnet Synchronous Motor for Flywheel Energy Storage System

Development of a J-T Micro Compressor

BELT-DRIVEN ALTERNATORS

Aspects of Permanent Magnet Machine Design

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

Modeling and Simulation of the drive system of elevator based on AMESIM

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

A Linear Magnetic-geared Free-piston Generator for Range-extended Electric Vehicles

Lower-Loss Technology

Transcription:

IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Research of the alternator on the stand efficiency aspect To cite this article: M Adamiec et al 08 IOP Conf. Ser.: Mater. Sci. Eng. 4 000 View the article online for updates and enhancements. This content was downloaded from IP address 48.5.3.83 on 6/0/09 at 07:6

International Automotive Conference (KONMOT08) IOP Conf. Series: Materials Science and Engineering 4 (08) 000 doi:0.088/757-899x/4//000 Research of the alternator on the stand efficiency aspect M Adamiec M Dziubiński and E Siemionek Lublin University of Technology, ul. Nadbystrzycka 36, 0-68 Lublin, Poland E-mail: m.adamiec@pollub.pl, m.dziubinski@pollub.pl, e.siemionek@pollub.pl Abstract. The article discusses the methodology of testing an alternator at a stand to determine its energy efficiency. The efficiency was calculated on the basis of the measurement of the electric power supplied to the drive motor and the power generated by the alternator, taking into account the mechanical and electrical losses of the motor and the belt drive. The efficiency of the machine as a three-phase synchronous generator, without rectifier and voltage regulator, was also determined in order to assess the influence of electronic components on the overall efficiency of the machine. The tests were performed for various rotational speeds and loads. Various physical factors and phenomena that have a negative impact on the efficiency of energy conversion in the vehicle electrical supply system are discussed.. Introduction The determination of the efficiency of a technical object shall be carried out in order to assess the correctness of its built, repair, reconditioning and comparison with other devices of similar design and purpose. The practical effects of the performance calculation are to improve existing solutions or to develop a control algorithm in order to make optimal use of the device or system, taking into account other aspects of its operation. Machines and drive systems are subject to electrical, mechanical and magnetic phenomena, as well as the associated energy transformations and energy losses. The easiest thing to do is to measure and calculate electric quantities, more difficult is to measure and calculate mechanical and magnetic quantities, which are subject to a higher level error and which for this purpose are converted into voltage signals. Depending on the measurement possibilities, as well as the objectives and expected effects, the efficiency is determined in the actual operating conditions of the device or on the bench and in a more complicated or simplified way [, ]. In automotive vehicles, the generator can be used as a separate machine or in combination with a starter. In the first case, it is a three-phase synchronous generator with a specifically designed rotor, which cooperates with an electronic rectifier system and a voltage regulator. A set of these elements in one housing is called an alternator. The most important changes that have been made to its design due to the increase in electric power of automotive vehicles are listed below [3, 4]: improvement of the cooling system, optimization of the magnetic circuit, modernization of the transmission system, use of multifunctional voltage regulators. These changes show that even well-proven and long-used devices are being successively improved. In particular, the last two aspects of the above have a strong relationship to the efficiency of the machine. Changes in the power transmission can reduce significant mechanical power losses, while in addition to controlling the energy distribution in the vehicle the multifunctional regulators can also make optimum Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd

International Automotive Conference (KONMOT08) IOP Conf. Series: Materials Science and Engineering 4 (08) 000 doi:0.088/757-899x/4//000 use of the efficiency of the generator. It is connected with voltage regulation by means of rotational speed changes, but first of all with excitation current formation, the value and course of which are closely connected with energy conversion efficiency []. To improve machine performance and efficiency, rotors with permanent magnet and an additional coil are also used, the current of which can more effectively regulate the magnetic field strength [5, 6]. The maximum alternator efficiency value given in the literature, depending on the rated voltage, power and type of excitation control, is in the range of 50-65% [4, 7, ]. In practice, the most important thing is to analyze its variability as a function of load and rotational speed.. Power losses in rotating electric machines Practically all power losses in rotating machines are related to the generation of heat, only the causes of this phenomenon are different [8]. The basic power losses are generated in the windings with resistance R, through which current of I intensity flows: P Cu RI () In this case it is also possible to take into account the variability of resistance as a function of temperature and the flow of alternating current (skin effect) and for this reason to calculate additional losses caused by the increase of temperature and current frequency. Power losses in ferromagnetic cores are caused by an alternating magnetic field, which cyclically changes polarity of the core (magnetic hysteresis) and induces eddy currents in it. The hysteresis losses ΔP h and eddy current losses ΔP r are calculated from the following equations: P c B f () h h P c B r r f (3) c h hysteresis loss coefficient, c r eddy current loss coefficient, B magnetic induction in the core, f current frequency (of magnetic field). On the other hand, additional magnetic losses are caused by pulsations of magnetic field caused by toothing of the armature core, field produced by higher harmonic flows of windings and deformation of magnetic field caused by transverse interaction of the armature [9]. Magnetic power losses in a machine operating as an alternator are also caused by the variable component of the excitation current, which is caused by the cyclical operation of the voltage regulator. For this reason fields rotating asynchronously can produce eddy currents in the rotor core [4, 7]. In a DC motor and a generator operating as a threephase synchronous generator excitation current hasn't got variable component. Power losses caused by current flow and voltage drops on rectifier diodes and voltage regulator elements (transistors, Zener diode, resistors) must also be taken into account in the alternator. Load and excitation currents of the alternator flow through the two diodes of the rectifier system at any time. A typical voltage drop on a silicon rectifier diode is 0.5 0.7 V. The power losses of ΔP d can be calculated according to the formula: I la alternator load current, I ea alternator excitation current, ΔU dp voltage drop on positive diode, ΔU dn voltage drop on negative diode, ΔU de voltage drop on excitation diode. P I U U ) I ( U U ) (4) d la ( dp dn ea de dn Mechanical losses are caused by the friction force of the moving parts against the stationary parts and the surrounding medium. They are calculated in different ways, e.g. according to the following formula [8]:

International Automotive Conference (KONMOT08) IOP Conf. Series: Materials Science and Engineering 4 (08) 000 doi:0.088/757-899x/4//000 μ coefficient of friction, F downforce, n rotational speed, α, α coefficients relating to the construction of the machine. P m ( F ) n (5) Power losses in insulation are taken into account only in machines supplied with voltage of several dozen or several hundred kilowatts or operating at frequencies of the order of kilohertz [8]: P in cu f tg (6) tg δ dielectric loss coefficient, c coefficient relating to the construction of the machine. 3. Research methodology A compact alternator with a nominal voltage of U n= V and nominal current of I n=80 A, equipped with a 9 diode rectifier and a conventional voltage regulator was used in the tests. As a drive motor, a DC commutator machine separately excited with a nominal voltage of U n=0 V and a nominal power of P n=00 W was used. The alternator has been modified in such way that the connection of the armature winding to the rectifier system has been interrupted and the voltage regulator has been connected to the excitation winding, and the contact points have been connected to the outside of the machine using additional wires (Fig. ). Thanks to these changes, the generator was able to operate as an alternator, with its original or externally connected rectifier and voltage regulator, and as a three-phase synchronous generator. The alternator test was carried out with the use of the original rectifier and voltage regulator. It was not possible to directly measure voltage drops on elements of these systems. In addition to the load and the battery charging currents, it was also possible to measure the excitation current. The rotational speed was measured by means of an inductive sensor and an oscilloscope calculating the frequency of its voltage. The tests were performed at three rotational speeds (3000, 4800, 6000 rpm) at variable load of the generator. Initially, the electric power of a driving motor engine running idle was determined: Pm U ai a U ei e (7) U a armature voltage, I a armature current, U e excitation voltage, I e excitation current. The electrical power of the motor transferring the torque to the alternator operating at idle state P m and the power of the motor driving the alternator operating at load state P m3 were calculated similarly (according to the formula 7). The output power on the drive motor shaft, connected by means of a belt transmission with an idling alternator, was calculated on the basis of the following: P P P ( I I R (8) m 4 m m a a ) a P m electrical power of the motor driving the alternator in the idle state, I a armature current of the motor driving the alternator in the idle state, 3

International Automotive Conference (KONMOT08) IOP Conf. Series: Materials Science and Engineering 4 (08) 000 doi:0.088/757-899x/4//000 R a resistance in the armature circuit of the motor. For higher accuracy, the power of P m4 was determined in the initial phase of the powertrain operation and after the measurements (at a higher temperature) and the mean value was calculated. Formula (8) takes into account the load losses in the armature circuit of the drive motor, which occur due to an increase of load and armature current. The output power of the motor shaft driving an alternator operating at load state was calculated from the following equations: Pm 5 Pm 3 Pm ( I a 3 I a ) Ra (9) P m3 electrical power of the motor driving the alternator at load state, I a3 armature current of the motor driving the alternator at load state. The electrical output power of the alternator was calculated on the basis of the following equation: Pa U B ( I l I ac ) (0) U B+ alternator mains voltage, I alternator load current, I ac battery charging current. The efficiency of the alternator was calculated as the ratio of the power P a to the power P m5. Then the configuration of connections was changed and the efficiency of the same machine was determined, but this time working as a three-phase synchronous generator with a resistance receiver Y connected. The load was changed symmetrically in all phases and the excitation current was supplied via power supply. Active power, current and voltage were measured in individual phases with the clamp power meter. Measurements were made at the same rotational speeds and at a constant excitation current of I e= A. On the basis of tests it has been established that the current of such value provides the lowest braking torque of the rotor of the generator in relation to the range of changes in the output power of the machine. Although a large range of efficiency changes have been achieved, it has not been possible to compare these results with those of an alternator machine. Therefore, an attempt was made to determine the efficiency of the generator again by selecting such excitation current values that were set by the voltage regulator when loading the generator. For each selected excitation current value, at constant rotational speed, the load on the generator was adjusted to obtain a similar active power of the three-phase receiver to the power of the receiver which loaded generator in the first part of the test. In this way, the efficiency variability of the alternator and the three-phase generator were determined under similar operating conditions. The electrical and mechanical power of the drive motor was calculated in the same way as that of the alternator, but to calculate the input power of the generator P in3f, the excitation power supplied by the PSU (power supply unit) is still taken into account: Pin 3 f Pm 3 Pm ( I a 3 I a ) R a U e I e () U e generator excitation voltage, I e generator excitation current. On the other hand the output power of the three-phase generator P out3f was calculated as the sum of the active power in the individual load phases, and the efficiency was calculated as the ratio of P out3f to P in3f. 4

International Automotive Conference (KONMOT08) IOP Conf. Series: Materials Science and Engineering 4 (08) 000 doi:0.088/757-899x/4//000 Figure. Modifications in the tested alternator's 4. Results of the research The measurement results are presented in the diagrams, on which the efficiencies of the alternator and three-phase generator as a function of output power, determined at constant speed, are presented (Fig. -4). The efficiency determined for the same excitation currents and similar power is greater for a machine operating as a three-phase generator, throughout the entire range of power changes at a rotational speed of 3000 rpm (Fig. ). At a higher speed of 4800 rpm, the two efficiencies are already very slightly different, at most of the measuring points the efficiency of the three-phase generator is slightly superior, at several points the values are almost equal and only at maximum power is the difference more pronounced (Fig. 3). However, for the highest rotational speed of 6000 rpm, in the range of lower power output, the efficiency of the three-phase generator is slightly higher, and for higher power values, the efficiency of the alternator gains an advantage (Fig. 4). The point of intersection of the characteristics, i.e. equalization of the efficiency values for two variants of operation, occurs just below half of the whole range of power changes, for its value equal to 300 W. The efficiency of a machine operating as a three-phase generator, at a constant excitation current of A, is less than two previously discussed efficiencies at lower power levels and more for its higher power levels. The differences are much greater for rotational speed of 4800 and 6000 rpm, and in these cases it can be seen that greater efficiency is achieved in the final power range of a machine operating at different excitation currents. In addition, the entire characteristic is shifted because machine operation at a constant excitation current of A starts at higher power and efficiency and the maximum power value is greater. 5

International Automotive Conference (KONMOT08) IOP Conf. Series: Materials Science and Engineering 4 (08) 000 doi:0.088/757-899x/4//000 Alternator Generator 3f Generator 3f (Ie=A) Efficiency [%] 70 60 50 40 30 0 0 0 0 00 00 300 400 500 Output Power [W] Figure. Efficiency of machine operating as an alternator and three-phase generator according to output power at 3000 rpm 60 Alternator Generator 3f Generator 3f (Ie=A) 50 Efficiency [%] 40 30 0 0 0 0 00 00 300 400 500 600 700 800 Output Power [W] Figure 3. Efficiency of machine operating as an alternator and three-phase generator according to output power at 4800 rpm 60 Alternator Generator 3f Generator 3f (Ie=A) 50 Efficiency [%] 40 30 0 0 0 0 00 00 300 400 500 600 700 800 900 000 Output Power [W] Figure 4. Efficiency of machine operating as an alternator and three-phase generator according to output power at 6000 rpm 6

International Automotive Conference (KONMOT08) IOP Conf. Series: Materials Science and Engineering 4 (08) 000 doi:0.088/757-899x/4//000 5. Summary and conclusions In order to calculate the efficiency of the alternator and the three-phase generator, a simplified method was used, consisting in determining the difference in power between the drive motor operating at load and idle, and load losses power in its winding and components of the armature circuit. The values of voltages, currents, power and resistance of individual elements of the drive system, necessary to calculate the input and output power of the machine were measured and, as a result, its efficiency achieved at different rotational speeds and loads, were measured. The aim of the research was to determine the real value of efficiency and the range of its changes as well as the influence of such electronic elements of alternator as rectifier system and voltage regulator on the total efficiency. Therefore, this value was determined for the machine operating as a self-excited alternator and a three-phase separately excited synchronous generator. Correct, regular diagrams have been achieved for the three rotational speed values, with small measuring deviations due to the unsimultaneous measurement of several values and the variability of the rotational speed and temperature. The diagrams show that it is not efficient to operate the generator at low load or at high rotational speed in relation to the load. The mechanical power losses associated with the transmission system and the frictional force of the various components are then predominant. The highest efficiency of 55% was achieved for the smallest of the three rotational speeds and almost the maximum load possible under these conditions. For higher rotational speeds the maximum efficiency is lower, but it is maintained within a wider load range. Determining the variability of efficiency under different operating conditions can be useful in vehicle electrical energy flow control systems for optimum control of the generator. The assessment of the power losses in the alternator electronics systems cannot be carried out explicitly as there are additional effects associated with the flow of alternating current during operation of the three-phase generator. This is best illustrated in Figure 4, where due to the higher rotational speed and frequency of the current, the inductive reactance of the receiver increases, resulting in increased energy losses and, as a result, a higher efficiency of the machine operating as an alternator than that of the three-phase generator supplying the receiver with alternating current. For a rotational speed of a test machine rotor of 6000 rpm, its voltage frequency shall be 600 Hz (the number of pairs of magnetic poles shall be six). Correspondingly, at 4800 rpm it is 480 Hz and at 3000 rpm it is 300 Hz. For the lowest rotational speed, when the reactance is small and the receiver is resistive, the current flow conditions are similar to those of direct current and it can be seen that the alternator, which is additionally equipped with a rectifier and voltage regulator, has a lower efficiency than a three-phase generator. For an average rotational speed of 4800 rpm, these differences are already very small. An additional factor causing magnetic power loss in the alternator is the pulsating nature of the excitation current, rectified by the diodes and interrupted cyclically by the voltage regulator (the variable component is present). It was also noticed that in the idling state of the machine, but after the excitation current is fed to the rotor winding, there is a braking torque which is the result of the magnetic field generated by the excitation winding and amplified by the rotor core and the field generated by the magnetized stator core. The mutual relation of the efficiency of the machine working as an alternator and the three-phase generator is molded depending on various factors and the proportions of several physical quantities. A simplified method of determining the efficiency of the generator enables the calculation of input and output power as well as power losses in the belt drive and machine windings. However, it does not allow to determine the remaining power loss components separately. References [] Niedworok A and Orzech Ł 06 Przegląd Elektrotechniczny 8 46 [] Whaley DM, Soong WL and Ertugrul N 004 Australasian Universities Power Engineering Conference (Brisbane) [3] Consoli A, Cacciato M, Scarcely G and Testa A 004 Industry Applications Magazine IEEE 0/6 35-4 [4] Friedrich G and Gimeno A 004 IEEE () -6 7

International Automotive Conference (KONMOT08) IOP Conf. Series: Materials Science and Engineering 4 (08) 000 doi:0.088/757-899x/4//000 [5] Bonisławski M, Pałka R, Paplicki P and Wardach M 04 Przegląd Elektrotechniczny 0 6 [6] Popenda A and Chwalba S 04 Przeglad Elektrotechniczny 65 [7] Ivankovic R, Cros J, Kakhki MT, Martins CA and Viarouge P 0 New Advances in Vehicular Technology and Automotive Engineering 6 69 [8] Gross CA 007 Electric Machines edition [9] Dziubiński M, Drozd A, Adamiec M and Siemionek E 06 IOP Conference Series: Materials Science and Engineering [WOS] /48-8