FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

Similar documents
FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

SERIES SX GILBERTS. Air Supply Valves. Features

SERIES SX. Air Supply Valves

SERIES C. Adjustable Deflection Grilles for Circular Ducting

SERIES GP. Security Grilles

SERIES 701, , 151, 152 AV 1201/1401

SERIES GP GILBERTS. Security Grilles. Features

SERIES SX. Air Supply Valves

SERIES PG. Perforated Face

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

SERIES GF. Heavy Duty Floor Grilles

SERIES JN GILBERTS. Jet Diffusers. Features PUBLICATION DIFFUSERS 8 JUNE 2007

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

SERIES K. Fixed Blade Grilles

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

SERIES K GILBERTS. Fixed Blade Grilles. Features

SERIES H. Heavy Duty Adjustable Deflection Grilles

SMOKE DAMPER - CLASS F MODEL BMSD

SERIES GZL. High Induction Linear Diffuser (Patented)

CURTAIN TYPE FIRE DAMPER

SERIES GSF. Fixed Swirl Diffusers (Patented)

SERIES H. Heavy Duty Adjustable Deflection Grilles

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

PRODUCTS BULLETIN PRODUCTS CATALOGUE

Actionair Smoke/Shield PTC

SERIES HSL. High Capacity Linear

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

Fire Dampers Catalogue

series FSD-FLD Fire and smoke dampers UL Approval

NEW. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

Motorized Fire Dampers

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Zero Leakage Isolation Damper

CONTROL SMOKE AND BALANCING DAMPERS

Catef Marine-Fire. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

SERIES GSL. Linear Slot Diffuser

SFD-EN Smoke/Fire Dampers

Actionair Control and Shut Off Dampers

Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

SERIES NV. Vision Proof Transfer Grilles

VOLUME CONTROL / REGULATING DAMPERS

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

BD Series. Backdraught Volume Regulating Damper M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

Systemair Fire Dampers

FD-C Series. Circular Single Blade Externally Resettable Combination Fire and Volume Control Damper B RITAI N

CFSD Series. Product Description

SERIES MBD. Multi-Blade Linear Diffuser

7/S5 FIRE DAMPER FD40. v 2.9 (en)

M A D E L. FOK-EIS-180 Fire dampers CE

Free Fall Fire Valve Range & Accessories

GILBERTS. Features. SFB (57.9) X UDC Dampers 2 OCT 2008

SINGLE DUCT TERMINAL UNITS

FSD60/MFSD60 Multi-blade Fire Damper

SERIES GB. Adjustable Slot Swirl Diffusers

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

Blade Features. AirShield Control and Shut Off Dampers. AirShield

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

Cell Ventilation Security Grille

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

SERIES GSJ. Adjustable Swirl Diffusers (Patented)

Zest Iris Duct Dampers

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

WG-38 SERIES. 38mm PITCH LOUVRES. 38mm PITCH LOUVRES

SERIES GD. Square and Circular Fixed Swirl Diffusers

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Marine Fire and Gas Dampers

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Fan - Powered Terminal Unit Series Flow

Series HCD Airfoil Control Damper

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.

BC 03. Fire Dampers FD-GB-30-AS LISTED

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

Systemair Fire Dampers

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

HotShield PTC TM. High Operating Temperature Smoke Management and Fire Dampers. Features

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Combustion gas damper EKO-SRB

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

PKIR3G, PKIS, PKIS3G and PKIS3GA

VARYCONTROL VAV Dual Duct Terminal Boxes

Fire/combustion gas damper EKO-JBG

Model FSD-212. Combination FIRE SMOKE DAMPERS

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

Fire/combustion gas damper EKO-JBL

Installation, Operation and Maintenance Manual

Smoke Dampers. Installation Instructions

Standard Installation Combination Fire/Smoke Damper Models: FS1(SS), FS2(SS) Fire Damper Models: MD19(SS)

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2 Fire Damper Models: MD19, MD39, MA19, MA39

Automatic Roof Door Vents

Transcription:

FIREGARD Curtain Fire Dampers DAMPERS SFB (.) X UDC. FEBRUARY 00 FEATURES Galvanised or Stainless Steel Interlocking Blades in Airtight Casing. Optional Stainless Steel Side Seals. Constant Tension Stainless Steel Closure Springs. Blade Closure Locking Ramp. External Visual Blade Position Indicator. GILBERTS

Introduction Gilberts Smoke and Fire Control Division, manufacture a full range of products designed to serve the smoke/fire protection industry including Duct Mounting combination Smoke/Fire Dampers, Door and Wall mounting Smoke/Fire Dampers and Duct Mounting Fire Dampers. Gilberts Firegard range provides a curtain type Firedamper designed to prevent the spread of flames through ductwork in fire conditions. Fitted where the ductwork passes through an existing fire barrier the units are activated by a fusible link element set to trigger at C. Operation of this link, which can also be tested manually, allows the blade pack to close instantly, in any orientation, under spring tension with guaranteed closure assured by the unique radiused locking ramps. Stainless steel or galvanised blades then provide a solid barrier to flames and smoke for up to hours. Independently tested by the Warrington Research Centre the units have a full hour fire rating. Available size ranges span from 00mm up to 00mm in width and 00mm up to 000mm in height. Units greater than the size range are supplied as multiple assemblies. Hevac installation frames are available for all models as an optional extra. Features A B C D A - Fire Damper Casing B - Fire Damper Blade Pack C - Fusible Link Element D - Solder Side Elevation of Fusible Link Element Fusible Link Assembly C A E B D A B C D E F Stainless Steel or galvanised interlocking blades provide a hour fire rating. Constant tension Stainless Steel springs ensure positive closure in horizontal or vertical positions. All welded galvanised mild steel airtight casing resists corrosion and prevents leakage. Angled Locking Ramps ensure full blade closure. Stainless Steel flexible side seals. (optional Extra) External visual blade position indicator (optional). F

Product Range Type FG This unit has been designed for low and medium air velocity ductwork systems. It can be installed in either the horizontal or vertical position where a fire compartment integrity is to be maintained PRESSURE DROP GRAPH Minimum free area = % velocity range 0 to. m/s PRESSURE DROP Pa 00 0 0 x 0mm 000 x 000mm Type FG Type FG Type FG (Blade Pack Outside Airstream) This unit has been designed for high air velocity ductwork systems. It can be installed in either the horizontal or vertical position where a fire compartment integrity is to be maintained PRESSURE DROP GRAPH Maximum unrestricted airflow velocity range 0 to m/s (Blade Pack Outside Airstream) This unit has been designed for low and high ductwork velocities associated with the ventilation and air conditioning industry. It is manufactured to suit circular ductwork, and can be installed in either a horizontal or vertical position PRESSURE DROP GRAPH Maximum unrestricted airflow velocity range 0 to m/s (Blade Pack Outside Airstream) This unit has been designed for low and high ductwork velocities associated with the ventilation and air conditioning industry. It is manufactured to suit oval ductwork, and can be installed in either a horizontal or vertical position PRESSURE DROP GRAPH Maximum unrestricted airflow velocity range 0 to m/s 00 00 PRESSURE DROP Pa 0 00 00 PRESSURE DROP Pa 0 00 00 PRESSURE DROP Pa 0 0 0 DUCT VELOCITY m/s 0 x 0mm 000 x 000mm 0 00 DUCT VELOCITY m/s 0 x 0mm 000 x 000mm 0 00 DUCT VELOCITY m/s 0 x 0mm 000 x 000mm 0 00 DUCT VELOCITY m/s

Dimensional Data Type FG SIZE RANGE STANDARD DAMPERS DAMPERS COMPLETE WITH 00-00mm WIDE INSTALLATION FRAMES 00-000mm HIGH 0 0 Duct Width - mm 00-00 Duct Height - mm 00-000 00-0 - 00 0-0 - 000 0 0 Type FG SIZE RANGE STANDARD DAMPERS DAMPERS COMPLETE WITH 00-00mm WIDE INSTALLATION FRAMES - 000mm HIGH 0 0 Duct Width - mm 00-00 Duct Height - mm 00-000 00-0 - 00 0-0 - 000 00-0 - 00 0-0 - 000 0 0 0 Type FG SIZE RANGE STANDARD DAMPERS DAMPERS COMPLETE WITH 00-000mm DIAMETER INSTALLATION FRAMES MINIMUM OVERALL SIZE + 0MM 0 0 Duct Width - mm 00-000 Duct Height - mm 00-000 00-0 - 00 0-0 - 000 00-0 0-00 0-0 0-000 0 Type FG SIZE RANGE STANDARD DAMPERS DAMPERS COMPLETE WITH 00-00mm WIDE INSTALLATION FRAMES 00-000mm HIGH 0 0 Duct Width - mm 00-00 Duct Height - mm 00-000 00-0 - 00 0-0 - 000 00-0 - 00 0-0 - 000 0 0 0 Note:. All dimensions are in mm.. Spigoted Models are supplied with actual spigot dimensions nominal less mm +/- mm. For sizes greater than detailed maximum sizes, multiple section units would be supplied.

SIZE RANGE STANDARD DAMPERS DAMPERS COMPLETE WITH 00-00mm WIDE INSTALLATION FRAMES 0-00mm HIGH Type FG (In Duct) Duct Width - mm 0-00 0 0 Duct Height - mm 0-000 0 As an alternative fixing arrangement for both ducts or walls, the type FG fire damper can be supplied without spigot connections. Multiple Assemblies Where the duct sizes exceed 00mm x 000mm two or more FG or FG Type units can be arranged in a complete multiple assembly joined together by SWG Galvanised Steel Closure Strips. Note: Before installation of any multiple assembly the proposed arrangements should be agreed with the relevant local authority (a suggested arrangement drawing can be supplied). Pack Unit Typical Vertical Assemblies Blade Closure Direction Indicated by Arrows Pack Unit Typical Horizontal Assemblies Blade Closure Direction Indicated by Arrows

Control Options Solenoid (non-failsafe) The Solenoid is normally de-energised (no power supply) and this holds the damper in the open position. When the solenoid is powered up by an electrical power signal the solenoid will operate, pulling a connecting cable, which releases the damper and allows it to close.the solenoid is housed in a control box enclosure, which should be mounted on the adjacent ductwork. A simple cable connection links the control box to the fusible link holding assembly. The cable length is metre as standard though other lengths can be specified.the Control box enclosure also includes a status indication light. When the solenoid is activated (indicating the damper is closed) the status light will illuminate RED.Standard Solenoid voltage is 0v AC (0Hz). Other voltages available on request. Available on Sizes 0 x 0 upto 00 x 000 and 0 to 000 dia Electro-Magnet (Failsafe) The Electro-Magnet is normally energised (power on) and this holds the damper in the open position. When the powered is interrupted the Electro-Magnet will operate, pulling a connecting cable, which releases the damper and allows it to close.the Electro-Magnet is housed in a control box enclosure, which should be mounted on the adjacent ductwork. A simple cable connection links the control box to the fusible link holding assembly. The cable length is metre as standard though other lengths can be specified.the Control box enclosure also includes a status indication light. When the Electro- Magnet is powered up (indicating the damper is open) the status light will illuminate GREEN.Standard Electro-Magnet voltage is v DC (0Hz). Other voltages available on request. Available on Sizes 0 x 0 upto 00 x 000 and 0 to 000 dia Trigger Release Providing a trigger operation feature, this self-locating and easily resettable cassette can be used with either the solenoid or electromagnet controls - or, as a standard component to assist the engineer in the resetting of the fire damper during regular inspection and maintenance procedures. Only available from 0 to 000mm (high).

Installation Frames HEVAC INSTALLATION FRAME (HVC //) The installation frame is designed to be factory assembled on to a fire damper. This frame will under fire conditions allow the damper to expand without distortion. Upstand flange webs with fixing tabs built into the surrounding structure ensure that the complete assembly will be retained within the structural opening. A factory assembled installation frame may be provided and fitted to a double module assembly not exceeding an overall ductwork size of x 0mm (split on the larger dimension). Adjacent frame assemblies must be separated by builders work of a minimum distance of mm (between installation frame upstand flanges unless approval has been previously obtained from the appropriate authority.) Where two fire dampers, or two double module assemblies are mounted in series to form a factory assembled four hour unit, each damper or double module assembly comprising the unit shall be provided with its own installation frame so as to allow each individual damper or double module assembly to expand under fire conditions. The work shall be carried out to the satisfaction of the appropriate authority which, in inner London, will be the District Surveyor. Any deviation must have similar approval. Building Ties for securing Unit to Structure Corner Joints permit internal expansion of Installation Frame Expansion Cleats between Fire and damper HORIZONTAL FLOOR MOUNTING Test Data FIRE TEST Fire tests conducted by the WARRINGTON RESEARCH CENTRE in both the horizontal and vertical position proved the Damper to comply with conditions specified by BRITISH STANDARD PART 0 for a 0 minute period. Also tested to : European Standard EN-: International Standard ISO 0-:E

Ordering Procedure SERIES: FG,FG,FG,FG or FG BLADE OPTIONS: Galvanised Blades...G Stainless Steel Blades...S FG G 0 x 0 VI IF QB SPM SIZE (Width x height mm) VISUAL INDICATOR INSTALLATION FRAME OPTIONS: Standard...IF Dry Wall Partition Options: Type A...DFA Type B...DFB CONTROL OPTIONS: Solenoid (State Voltage):...SOL+Voltage Electro Magnet (State Voltage):...EM + Voltage Quartzoid Bulb...QB Thermo-Electric Quartzoid Bulb...EQB MICROSWITCH OPTIONS: Single Pole...SP Double Pole...DP NUMBER REQUIRED Engineering Specification Contact Fire Dampers shall be Steel Curtain Dampers consisting of a continuous series of folded and interlocked blades contained within and arranged to close the opening of a surrounding frame. The frame and component parts to be not less than.mm Cold Reduced Steel, to BS EN0 Grade DX D Z N.A.C. The blades to be 0.mm Stainless Steel to grade to BS EN 00 part or, galvanised mild steel to BS EN 0 grade DXD Z N.A.C. Shaped on both edges to form a continuous interlocking hinge extending the full length of the blade, and ensuring correct action, and having a reinforcing swage centrally along the length to provide maximum strength and rigidity. The assembly of blades to be fixed to the Damper frame by the first blade being riveted flat to the frame with zinc plated boron steel rivets.mm long x mm diameter oval headed selfpiecing bifurated rivets heat treated to 0/0 V.P.N., 0mm from the corners of the frame, and not more than 0mm centres along the length of the blade. The Damper framework to be of formed section to provide two continuous internal flanges or jambs covering the blade perimeters by not less than mm. The number of blades to be sufficient only to close the opening in the frame when in the fully extended position, with a minimum clearance between the edges of the blade and the casing of mm. GILBERTS Head Office and Works GILBERTS (BLACKPOOL) LTD Gilair Works, Clifton Road, Blackpool. Lancashire FY QT. Telephone: (0) Fax: (0) e-mail: sales@gilbertsblackpool.com Web: www.gilbertsblackpool.com The Damper blades to be held in the open position by means of an approved pattern fusible link, set to operate at C unless otherwise specified. The link to be arranged in an exposed position in the centre of the leading blade, consisting of tinned brass parts so positioned and fixed as not to impede the operation of the Damper blades upon the fusing of the link. The Damper when used in a vertical position to be suitably marked "Top". All Dampers used in either vertical or horizontal positions to be closed by two constant force coiled band springs, exerting a pull of not less than N to be of Stainless Steel type, mm wide. The tail end of the springs to be rounded and fixed to the leading blade by a Stainless Steel rivet.mm. The coiled end of each spring to be retained around a corrosive resistant steel pivot fixed to a locking bracket in such a way that it will not become dislodged from the pivot by side movement. The locking bracket to provide maximum cover over the coiled spring to prevent damage, and to be secured to the Damper by not less than two.mm Stainless Steel rivets. Locking brackets shall be secured in such a position that at no time do they obstruct or interfere with the operation of the Damper but will positively lock the leading blade when the Damper is in the closed position. Gilberts (Blackpool) Ltd reserve the right to alter the specification without notice. The information contained in this leaflet is correct at time of going to press 00.