by Instrumentation Pumps 1 / 8

Similar documents
STH/Q SET UP INSTRUCTIONS

IDS INDUSTRIAL DISPENSER INSTRUCTIONS ISO SAFETY INSTRUCTIONS

Table Of Contents. Section Description Page #

UV PROCESS SUPPLY, INC.

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

VMP Pump Modules. TSi-Vc. Zaxis, Inc S W. Salt Lake City, Utah 84119

MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

LAB PUMP JR. SAFETY INSTRUCTIONS INSTRUCTIONS FOR ALL H MODEL PUMPS MODELS RH, RHB, RHSY, RHV, PIP

MICRO SL PUMP MODULE Page 7-1. Table Of Contents. Section Description Page #

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL

MAINTENANCE MANUAL DI 16

1/2" AIR DRIVEN DIAPHRAGM PUMP

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

IN USA FAX:

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

T21 Thermal Differential Switch

Dosing Pump Operational Manual

Digital Burette. Assembly and operating instructions. For capacities of 30ml & 50ml

SERVICE MANUAL Moyno Mag Drive Series Motorized Pumps with Magnetic Drives 331, 332, 333, 344 MODELS

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

PPM100 Owner s Manual

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

Techcon Systems TS5000 Series Rotary Valve

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

2 Model 826 Dispensing Valve User Guide

Electronic Metering Pump

TECHNICAL SERVICE MANUAL HEAVY-DUTY BRACKET MOUNTED PUMPS SERIES 120 and SERIES 124 MODELS J, K, KK, L, LQ, LL AND LM

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

An IDEX Water & Wastewater Business. pulsafeeder.com. Electronic Metering Pump

INSTALLATION & OPERATING INSTRUCTIONS

DEMA SINGLE-FEED MODEL: 651GAP& 651GAP-1 INSTALLATION INSTRUCTIONS

OPERATION MANUAL NT80 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

Z100A Clinical Centrifuge

Techcon Systems TS7000 Series Interchangeable Material Path Rotary Valve

Operating Manual Includes Pumps: PG-9000 Part #R809606

MODEL 905V OPERATING INSTRUCTIONS

A measured step forward. AIRTRAN TM - Air Operated Diaphragm Pumps

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

Prospenser. User Manual Mode d emploi Bedienungsanleitung Manual Usuario. For capacities of 2.5 ml 5 ml 10 ml 30 ml and 50 ml

Document Library TS Data Sheet Universal Fuel System Cleaner. Data Sheet. Public

Installation Instructions

BMK-18 U.S. Patent #5,298,158

SAFETY MANUAL READ FIRST!

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

SERVICE INSTRUCTIONS. Transfer Pump

TECHNICAL SERVICE MANUAL GENERAL PURPOSE BRACKET MOUNTED PUMPS SERIES 115 MODELS G, GX2, H and HX4

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

Troubleshooting 3Z8 038 Rev B

D Instructions/Parts. Siphon Feed Detail Spray Gun D

PRESSURIZED DIATOMACEOUS EARTH FILTER SYSTEM

TECHNICAL SERVICE MANUAL GENERAL PURPOSE JACKETED PUMPS SERIES 230 MODELS HX4, KK, LQ, Q, M, N

13. CRANKCASE/CRANKSHAFT/BALANCER/PISTON/CYLINDER

SINGLE ACTION FLUID PUMP

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

NECO Pumping Systems

Precision-24 Manual & Specification

HALLMARK INDUSTRIES INC

Disc Brake System ( For Cross-Country)

Please take time to read and understand these installation instructions.

PRODUCT OPERATING MANUAL

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

TurboWerx Spartan-series TWX V Electric Scavenge Pump

Instruction Manual. Maximum Operating Pressure 510 bar

Instruction Manual. This Manual should be made available to persons responsible for Installation, Operation and Maintenance. Pump Model No...

FILLING MACHINES SINGLE HEAD

OPERATOR S MANUAL A

Zaxis Valveless Metering Pump User Manual

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

Read these instructions thoroughly before attempting to install this option.

IN-LINE HYDRAULIC FLOW TESTER

VSP SERIES Installation, Operation and Maintenance Manual

Rocket High Performance Injector. Single Barb. Dual Barb. B Series Injectors. C Series Injectors. Adjustable Water Flow

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Series 3900/M Pump Retrofit Kit

Type 80 Wafer and Type 81 Bolt-Thru Isolation Rings. Installation, Maintenance and Safety Instructions

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

PeroxiDraw Dispenser

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules.

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

VP12 High Viscosity Piston Pump

Manual for the Dragonfly tattoo machine rev.2

NOTE: DISCONNECT MAIN POWER LOCK OUT AND TAG BEFORE PERFORMING ANY PROCEDURES IN THIS SECTION.

NSGV EVE-ER I, O, & M MANUAL

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

RAAS Troubleshooting Guide. Confirm that the power switch to the unit is in the on position.

Operation and Maintenance Instructions

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

Techcon Systems TS5322 TS5322D Adjustable Mini Spool Valve. User Guide

BMK-27. Dual Remote Filtration System Mounting Kit. Installation and Servicing Instructions (DURAMAX) C. Oil Supply

Transcription:

600-000 by Instrumentation Pumps 1 / 8

1. Safety Requirements... 3 2. Pump Mounting... 3 3. General Set Up... 4 3.1. Quick Start... 4 3.2. Speed... 5 3.3. Fluidics... 5 4. Maintenance... 5 4.1. Idle Position... 5 4.2. Pump Head Seized... 6 5. Calibration... 7 6. Troubleshooting... 8 6.1. Loud Noise... 8 2 / 8

1. Safety Requirements Before using an Instrument Pump Inc. product, read the following safety instructions as well as specific product specifications and operating instructions. Warning! Fire, electrical shock, injury and damage may occur if metering pump products are not used in accordance with Instrument Pump, Inc. specifications and operation instructions. Disconnect electrical power before checking pump for any problems. Connect motor, speed controllers, or any other electrical devices based on Instrument Pump, Inc. specifications. Unauthorized work performed on the product by the purchaser or by third parties can impair product functionality and thereby relieves Instrument Pump, Inc. of all warranty claims or liability for any misuse that will cause damage to product and/or injury to the individual. Power cables and leads should not be bent, pulled or inserted by excessive force. Otherwise there is a threat of electrical shock or fire. Replace any inline fuses only with fuse rating as specified by Instrument Pump, Inc. When pump/drive is under operation, never point discharge tubing into face or touch any rotating components of pump. In a power down thermal overload cut-in condition, unplug or turn off power to pump. Always allow a cool down period before restarting: otherwise, injury or damage may occur. For 30 seconds after power is removed from pump/drive: do not touch any output terminals. Electrical shock may occur because of residual voltage. Do not put wet fingers into power outlet of unit. Do not operate with wet hands. Do not operate drive assemblies that require a hard mount (to be bolted down) unless they are mounted per Instrument Pump, Inc. specifications, if not injury may occur and/or damage to unit. Do not touch any rotating pump or motor components: injury may occur. Do not run pump dry, unless designed for that service. Running dry is harmful to the pump, and will cause excessive heating due to internal friction. Check pump rotation and inlet/outlet pump port orientation before connecting power to pump. If not injury may occur. When pulling out cords from outlets do not pull cord, grasp plug to prevent plug damage or electrical shock. Instrument Pump Inc. Drive Motors become HOT and can cause a burn. DO NOT TOUCH! 2. Pump Mounting To gain optimal performance out of your Instrument Pump metering pump, ensure that your pump is mounted vertically with the motor or drive pointing towards the ceiling, and the pump head or wet end pointing towards the floor. This orientation will promote air bubbles to exit the pumping chamber for optimal precision and performance. Please note that air bubbles can act as springs in your medium, which will impact the performance of your metering or dosing pump. 3 / 8

3. General Set Up 3.1. Quick Start 1. Mount pump upside down with motor facing the ceiling. 2. Connect Source fitting (1/4-28) to hinge side of pump. 3. Connect Dispense fitting (1/4-28) to opposite side of hinge. If you have a stainless steel pump head, then your fitting needs to be long enough to seal on the ceramic flat inside the pump head. The fitting also acts as a press fit to ensure that the ceramics do not spin inside the pump head. Please check the ceramic sleeve is oriented correctly in the stainless steel pump head before replacing fittings. If you have a PVDF pump head, then your fitting will seal against a mating surface inside the female 1/4-28 thread. The ceramics are press fit into the PVDF pump head so it should not move. 4. Attach desired pump nozzle. Begin dispensing. (https://i0.wp.com/instrumentpump.com/wpcontent/uploads/2018/02/screen-shot-2018-02-12-at-4.22.09-pm.png?ssl=1) (https://i0.wp.com/instrumentpump.com/wp- 4 / 8

content/uploads/2018/02/idle-position.png?ssl=1) 5. If you are having high variations in shot size then there may be air bubbles in the fluid circuit or your setup is incorrect. 6. Adjust shot size if necessary by turning the adjustment screw on the hinge. This will void your factory calibration. 7. If your shot is not a consistent flow and you have removed air from the fluid circuit then you may need to start the spindle in Ready position, so the flat on the ceramics starts out in the ready position. 3.2. Speed For media of 500 centipoise (cp) or less a stroke rate of 120 to 350 rpm is ideal. For media with greater than 500 centipoise (cp) a slower RPM is recommended. Please keep in mind this is highly contingent upon your application. 3.3. Fluidics Inlet (Suction) tubing: To avoid cavitation use the most resilient tubing possible with the largest inside diameter (I.D.). Outlet (Dispense) tubing: For the best dispense performance use rigid Teflon tubing, which will reduce peristaltic action) with an equal or smaller I.D. than the inlet tubing. To clarify, ideally you would like to have a larger ID tubing for inlet side of your metering pump in comparison to the outlet to prevent cavitation. 4. Maintenance A running pump is a happy pump. 4.1. Idle Position Due to the harsh nature of certain applications such as battery manufacturing or waste water treatment dosing, it is important to keep the pump running. If your metering pump application has a long cycle time or your metering pump is run infrequently, it is in your best interest to keep the wetted path wet. If your metering pump is in the non-operating mode for an extended period of time: 1. Completely flush out the pump with water 2. During the non-operating period leave the pumps fluid circuit or wetted path wet with flush water. 3. Extend piston all the way to towards the bottom of the liner and position flat on piston in the idle or closed position Stop metering or dosing pump While monitoring the sensor signal, instruct motor to turn clockwise while looking for the leading edge of the flag. The leading edge of the flag is the edge of the flag you see first when rotating clockwise. Once the sensor sees the leading edge of the flag rotate the spindle counter clockwise 90 degrees. Step 3 ensures that the flat on the piston is not communicating with the inlet or outlet port. 5 / 8

(https://i0.wp.com/instrumentpump.com/wp-content/uploads/2018/02/idle-position.png?ssl=1) 4.2. Pump Head Seized DO NOT FORCE THE ASSEMBLY FREE OR YOU COULD DAMAGE THE PRODUCT! If a metering pump remains idle for long periods of time and the media dries out then there is a chance the pump head can be seized or frozen. Here are some things you can try before sending the pump back to the factory for maintenance. If your metering pump is still in an instrument we recommend: 1. Cycling the pump clockwise and counter clockwise at a slow speed in a high torque mode 2. Start and stop the pump to free the system 3. With the power to the stepper motor off, if you can access the pump head with your fingers, rotate the spindle back and forth. This can be accomplished with your index finger pushing against the side of the spindle 6 / 8

If this does not work, remove your pump from the instrument. 1. Soak the top portion of the pump head (pump head only) in a warm water bath for a minimum of 20 minutes. Using your fingers, gently attempt to rotate the spindle back and forth. THIS SHOULD NOT AFFECT CALIBRATION. (https://i1.wp.com/instrumentpump.com/wpcontent/uploads/2018/02/screen-shot-2018-02-13-at-11.10.20-am.png?ssl=1) If the piston is still seized: 1. GENTLY remove the pump head by removing the two screws holding the pump head to the pump body. While removing the pump head, twist, tilt & pull the pump head/cylinder/piston assembly such that the piston does not travel too far out of the cylinder. The goal is to remove the pin on the piston out of the bearing on the spindle without removing the piston from the cylinder. There are two lip seals inside the pump head assembly that can be damaged if the flat on the piston comes into contact with the seals hence why you need to delicately remove the pump head. 2. Soak the piston/cylinder assembly in warm water for a minimum of 20 minutes. An ultrasonic bath may be helpful. 3. Try to loosen the assembly by hand by gently rolling the piston back and forth. 4. Reassemble the pump head assembly back onto the pump body, by reversing the direction you just followed. 5. Rotate the assembly via the spindle to ensure that the pump head is correctly assembled. 6. Check the pump for calibration. 7. If you cannot fix the problem, please contact Instrument Pump Inc. 5. Calibration Calibration is set at the Factory and should not be changed. 1. Flush the system with clean alcohol or suitable cleaning/wetting agent before using the metering pump for first time. Prime the pump with desired media and ensure that NO AIR BUBBLES are in the fluid circuit. 2. Put the pump head in the ready position with the piston-flat perpendicular to the inlet port. 3. Determine what the pump s dispense volume is by cycling the pump for a complete 360º revolution. Dispense onto an analytical pan balance and observe the volume. Readjust the pump s dispense volume by turning the socket head screw from the motor side of the pump. There is a small access hole near where the motor mounts to the pump body. Using a tool, decrease the pump volume by turning the adjustment screw clockwise or increase the pump dispense volume by turning the adjustment screw counter clockwise. 7 / 8

Powered by TCPDF (www.tcpdf.org) 600-000 (https://i1.wp.com/instrumentpump.com/wp-content/uploads/2018/02/screen- Shot-2018-02-13-at-11.31.49-AM.png?ssl=1) Note: 1 ml of water = 1 gram. A correction factor is required for other media. 6. Troubleshooting 6.1. Loud Noise At high rpm rates you may hear a loud hammering sound. This can be caused from bubbles being present in the pumping chamber. Causes and solutions for bubbles in the pumping chamber might include: 1. Poor seal at the suction fitting Solution: Use teflon tape to seal the inlet fitting 2. Fluid vaporization or cavitation and degassing Solutions: Increase the diameter of the suction tubing. Reduce suction lift height Pressurize suction supply container Position pump below supply source for gravimetric flow Reduce viscosity of fluid by heating or diluting Reduce flow rate Add pulse suppressors in suction and discharge lines This can also be accomplished by adding resilience in your fluid circuit. Resilient tubing can act as a pulse suppressant, which might include flexible tubing such as viton, hypalon, gum rubber, or soft vinyl. Shield this tubing in case of rupture. Bubble traps can also be used as pule suppressants. 8 / 8