New UST Regulations. What follows are the changes to EPA s regulations that TMS believes impacts you, the owner/operator, the most.

Similar documents
Overview of Revisions to the Federal Underground Storage Tank (UST) Regulations. Storage Tank Advisory Committee Harrisburg, PA September 1, 2015

Mark S. Morgan, Regulatory Counsel

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

401 KAR 42:020. UST systems: design, construction, installation, and registration.

Operating And Maintaining Underground Storage Tank Systems UPDATED Practical Help And Checklists. Printed on Recycled Paper

BUREAU OF UNDERGROUND STORAGE TANK REGULATIONS RELEASE PREVENTION SECTION

Operational Compliance Closure/Release Response/Corrective Action at Underground Storage Tank Facilities

Underground Storage Tank. City of Burbank UST Owners & Operators

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit

Management of Underground Storage Tanks

Overview of an Underground Storage Tank Inspection

Compliance Strategies and Benefits

EPA UST Regulations Update May 22, 2018

Inspector's Initials: Tank Owner or Agent Signature: Title: Date:

Notification for Underground Storage Tanks

Grant Guidelines To States For Implementing The Secondary Containment Provision Of The Energy Policy Act Of 2005

(Please type or use black ink)

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

Underground Oil Storage Tanks Annual Inspection Report

Massachusetts Department of Environmental Protection Underground Storage Tank Program

Questions And Answers About The 2015 Underground Storage Tank Regulation As Of May 2017

Form UST FP-290 Notification for Underground Storage Tanks Regulated Under 527 CMR 9.00

PEI/RP Recommended Practices for the Inspection and Maintenance of UST Systems

Semiannual Report Of UST Performance Measures End Of Fiscal Year 2018 (October 1, 2017 September 30, 2018)

Arizona Tank Closure, Assessment and Response

Understanding the Colorado Annual Compliance Package. William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety

FACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL WHO CAN PERFORM THE TEST

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

Operating And Maintaining Underground Storage Tank Systems. Practical Help And Checklists. Printed on Recycled Paper

PETROLEUM PRODUCT STORAGE TANK REGULATION SAFETY AND BUILDINGS DIVISION BUREAU OF PETROLEUM INSPECTION AND FIRE PROTECTION

NYSDEC PBS REGULATIONS Heating Oil Tanks

Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information

Safe Operating Procedure

UST Program Overview. NISTM Conference June 17, Mark Barolo EPA, Office of Underground Storage Tanks

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA

Frequent Mishaps and Solutions with Regulated Underground Storage Tanks in Pennsylvania

6. Tanks - Leak Detection. NCDENR Division of Waste Management Underground Storage Tank Section

Sunoco, Inc Market Street LL Philadelphia, PA June 29, 2006

NCDEQ Underground Storage Tank Section

EPA REGULATORY UPDATE PEI Convention at the NACS Show October 8, 2018 Las Vegas, NV

P.O. Box 435 Saratoga Springs, NY 12866

TITLE 165. CORPORATION COMMISSION CHAPTER 25. UNDERGROUND STORAGE TANKS RM PROPOSED RULES NOVEMBER 30, 2015

CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR

New UST Installation Inspection Checklist

OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF UST S AN OVERVIEW OF UNDERGROUND STORAGE TANK REQUIREMENTS

ANNUAL UST SYSTEM INSPECTION CHECKLIST

INTEGRITY TESTING OF CONTAINMENT SUMPS AND SPILL BUCKETS PEI RP1200

PENNSYLVANIA ABOVE GROUND STORAGE TANKS

Monthly Walkthrough Inspections

Provide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext.

Underground Storage Tank Annual Compliance Inspection (Revised 1/2015)

UST General Requirements Inspection Checklist

North Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section

REVISOR CKIWru. t.tz 42, section 692L et seq.; or. A. system holding: (! a mixture of such hazardous waste and other regulated substances; {!

Environmental Regulations and Codes For Underground Tank Storage of Flammable & Combustible Liquids

UST Compliance Assistance Handbook

Syracuse University Petroleum Bulk Storage Tank Program Manual

Petroleum Storage Tank Release Detection and Inventory Control

Underground Storage Tank Guidance for Commercial Building Inspectors

Fuel Tank Management: PBS, USTs and the Energy Policy Act of 2005

New Regs Get Ready for Containment Testing if You Haven t Done So Already!

Underground Storage Tank Certification Examinations. Presentation to ASTSWMO November 27, 2007 UST SYSTEM OPERATOR CERTIFICATION

40 CFR 63, Subpart CCCCCC

Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations

South Tacoma Groundwater Protection District Spill Prevention and Response Plan

PURPOSE RESPONSIBILITY

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

DEPARTMENT OF ENVIRONMENTAL CONSERVATION

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

RHODE ISLAND New England Storage Tanks Conference Westborough, MA. Joe Cunningham Jillian Thompson

Update for Ohio BUSTR Class A and B UST Operator Training New regulations UST operations. Robert J May PE Synergy Environmental April 2018

New Tank Installations. Peter Rollo

COLORADO DEPARTMENT OF LABOR AND EMPLOYMENT DIVISION OF OIL AND PUBLIC SAFETY STATISTICAL INVENTORY RECONCILIATION (SIR) GUIDANCE DOCUMENT

SECTION FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS)

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

UNDERGROUND STORAGE TANK INSPECTION CHECKLIST

Leak Detection for Petroleum UST and Piping

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

TITLE 165. CORPORATION COMMISSION CHAPTER 25. UNDERGROUND STORAGE TANKS EFFECTIVE September 11, 2017

Pennsylvania DEP: Maintaining UST Compliance and Regulation Updates. NISTM 8 th Annual Pennsylvania Storage Tank Conference May 18, 2017

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

SWCAA 492. Oxygenated Fuels

Management of Underground Storage Tanks

E. Augusta, Spokane, WA (509) E. Augusta, Spokane, WA (509)

2018 UST Regulation Revision Comment Worksheet

This handbook is provided as a general guide. assistance/content/storage-tank-compliance

NYSDEC CBS Compliance Requirements

Regulatory Changes: Chapter 245. AST s

Preventing Leaks and Spills at Service Stations. A Guide for Facilities

Georgia Drycleaner Compliance Calendar

Ohio Department of Commerce, Division of State Fire Marshal, BUSTR Performing Work on Existing UST Systems June 6, 2012

Monthly Biodiesel Production Report

RFS2: Where Are We Now And Where Are We Heading? Paul N. Argyropoulos

Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities

Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC

State of New Jersey. Department of Environmental Protection Air Quality Permitting

ES Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number

Transcription:

New UST Regulations The long awaited UST regulations were released by the EPA on June 22, 2015 and soon will be published in the Federal Register. The new regulations will go into effect 90 days after publication. The new regulations require more equipment testing, facility inspections, documentation and keeping the UST regulators informed of changes at facilities. Included in the new regulations are some rules that were addendums to previous UST rules and have been previously put in place. One example is the UST operator training rule that actually became effective in 2006. Kansas was the third state to adopt this regulation and began training in November 2007. What follows are the changes to EPA s regulations that TMS believes impacts you, the owner/operator, the most. Following each new or updated rule is when it will be or was implemented. Operator Training Owners and operators designate at least one individual for A and B operator classes and all individuals that meet Class C operator definition. Designated operators must be trained on minimum defined areas and may need to be retrained if the UST system is not in compliance. Owners and operators retain a list of designated operators currently trained at each facility and proof of training or retraining. Documentation can be kept offsite. EPA adds definitions for Class A operator, Class B operator, Class C operator, and training program. This was part of the 2005 Energy Policy Act and is already in effect in Kansas Secondary Containment Owners and operators install secondary containment and interstitial monitoring for all (including petroleum) new and replaced tanks and piping (except safe suction piping and piping associated with field-constructed tanks greater than 50,000 gallons in size and airport hydrant systems). Owners and operators must replace the entire piping run when 50 percent or more of piping, excluding connectors, is removed and other piping is installed. Owners and operators install under-dispenser containment for all new dispenser systems. EPA adds definitions for dispenser, dispenser system, replaced, secondary containment, and under-dispenser containment. Kansas Adopted this rule in July, 2013. Periodic Walkthrough Inspections (reprinted with permission from the PEI TulsaLetter written by Robert Renkes). The regulation requires owners and operators to conduct walkthrough inspections as follows: Every 30 days check spill prevention equipment for damage and remove liquid or debris; check for and remove obstructions in the fill pipe; check the fill cap to ensure it is securely on the fill pipe; and for double-walled spill buckets with interstitial monitoring, check for a leak in the interstitial area (exception: owners and operators of spill prevention equipment at UST systems receiving deliveries at intervals greater than 30 days may check that equipment prior to each delivery). Also check release detection equipment to ensure it is operating with no alarms or unusual operating conditions present and ensure release detection records are reviewed and current. Annually check containment sumps for damage and leaks to the containment area or releases into the environment; remove liquid or debris in contained sumps; and for double-walled containment sumps with interstitial monitoring, check for a leak in the interstitial area. Also check hand-held release detection equipment, such as gauge sticks and bailers, for operability and serviceability. The regulation allows owners and operators to conduct operation and maintenance walkthrough inspections according to a standard code of practice developed by a nationally recognized association or independent testing laboratory, or according to requirements developed by the implementing agency. The inspections must check equipment in a manner comparable to the walkthrough inspection requirements described above. EPA included PEI s Recommended Practices for the Inspection and Maintenance of UST Systems (PEI/RP900) as a code of practice that may be used to meet the walkthrough inspection requirement. Owners and operators who use the code of practice option for meeting UST requirements must use the entire code of practice. For example, owners and operators would not meet the walkthrough inspection requirement if they chose to follow only some of the walkthrough inspection areas in the code of practice while ignoring others.

Other requirements concerning walkthrough requirements include: To align implementation of all operation and maintenance requirements, the regulation requires owners and operators to begin conducting walkthrough inspections three years after the effective date of the final UST regulation. EPA will not change the cathodic protection checks at the 60-day interval specified in the 1988 UST regulation. Monitoring and observation wells do not have to be checked to ensure they are secure. Owners and operators are required to maintain records of walkthrough inspections for one year. Spill Containment Owners and operators must have equipment tested at least once every three years for liquid tightness or use a double-walled spill bucket with periodic interstitial monitoring. Overfill Prevention Equipment Owners and operators must inspect at least once every three years to ensure equipment is set to activate at the appropriate level in the tank when regulated substances reach that height. Secondary Containment Testing Owners and operators must test containment sumps used for piping interstitial monitoring every three years for liquid tightness or use a double-walled containment sump with periodic interstitial monitoring. Release Detection Equipment Owners and operators must test annually to ensure release detection equipment (including LLDs) is operating properly. Ball Float Valves (flow restrictors in vent lines). (reprinted with permission from the PEI TulsaLetter written by Robert Renkes) EPA eliminated the use of flow restrictors in vent lines as an overfill protection option for new UST systems installations and when overfill equipment is replaced. Ball float valves may still be used on tanks installed on or before the effective date of the regulation as long as the ball float continues to operate effectively. Beginning three years after the implementation date, ball float valves must be tested for proper operation once every three years. If the ball float valve is not operating properly and cannot be repaired, the overfill device must be replaced with one of the other two types of overfill prevention (automatic shutoff devices or overfill alarms). Internal Lined Tanks EPA revises the internal lining requirement to mandate that owners and operators must permanently close tanks using internal lining as the sole method of corrosion protection if the internal lining fails the periodic inspection and cannot be repaired according to a code of practice. Notification EPA adds a requirement that owners notify the implementing agency within 30 days of UST system ownership change. EPA adds a requirement that, within three years, owners submit a one-time notification for previously deferred FCTs and AHSs. EPA updated the notification form to reflect the new changes and editorial/formatting revisions. EPA created new notification of ownership change form for owners to submit when necessary. EPA adds a requirement that owners and operators notify the implementing agency at least 30 days prior to switching to a regulated substance containing greater than 10 percent ethanol, greater than 20 percent biodiesel, or any other regulated substance the implementing agency identifies and meet one of the following: * Demonstrate compatibility through a listing by a nationally recognized independent testing laboratory or through equipment or component manufacturer approval; * Or use another method determined by the implementing agency to be no less protective of human health and the environment than the compatibility demonstration methods listed above

EPA adds a requirement to maintain records to demonstrate compliance with 280.32 for as long as the UST system is storing regulated substances containing greater than 10 percent ethanol, greater than 20 percent biodiesel, or any other regulated substance the implementing agency identifies. EPA removes references to one code of practice. EPA revises definitions of motor fuel and regulated substance. Repairs EPA revises definition to remove the link that a repair must be associated with a release and adds examples of other UST system components that can be repaired. EPA adds a requirement for owners and operators to test within 30 days after a repair to spill or overfill equipment and secondary containment areas. Records for each repair must be kept until the UST is permanently closed or undergoes a change in service. Groundwater and Vapor Monitoring (reprinted with permission from the PEI TulsaLetter written by Robert Renkes) EPA determined that vapor monitoring and groundwater monitoring are used by 5 percent of the UST owners to comply with the Agency s release detection requirements. UST owners in Arkansas (29 percent), Louisiana (12 percent) and Mississippi (65 percent) rely on vapor monitoring, groundwater monitoring, or a combination more often than UST owners throughout the rest of the country. The widespread use of these release detection methods influenced EPA to continue to allow their use in meeting the regulation, provided owners and operators demonstrate proper installation and performance through site assessments. Implementation: Record of site assessment within three years Interstitial Monitoring Results EPA adds interstitial monitoring alarms as an example of an unusual operating condition under release reporting. EPA adds a choice for secondary containment testing for secondarily contained tanks and piping using interstitial monitoring for the system test under release investigation and confirmation. EPA adds closure as an option if a system test confirms a leak. EPA clarifies use of the terms release and leak. Release Detection for UST Systems Used With Emergency Power Generators (reprinted with permission from the PEI TulsaLetter written by Robert Renkes) EPA eliminated the deferral for release detection for UST systems storing fuel solely for use by emergency power generators. The regulation allows owners and operators flexibility to choose the most appropriate release detection methods for their systems, including line leak detectors that trigger an alarm only and do not necessarily shut down the pumps. The regulation requires that the alarm must be transmitted to a monitoring center where someone on site can hear or see the alarm and respond to a suspected or confirmed release. Owners of emergency generator tanks installed before the effective date of the regulation must begin meeting the release detection requirements within three years of the effective date. USTs storing fuel for emergency power generation installed after the effective date must meet the release detection requirements at installation. Field-erected Tanks (reprinted with permission from the PEI TulsaLetter written by Robert Renkes) EPA removed the 1988 deferral of field-erected tanks (FETs) in UST systems from regulation. The regulation now provides that the current release detection methods in subpart D of the 1988 regulation are appropriate for FETs less than 50,000 gallons. For those tanks, EPA did not establish leak detection requirements beyond those listed for conventional UST systems. EPA also retained the option for owners and operators to demonstrate to the implementing agencies release detection methods as effective as those stated in the final UST regulation. Implementing agencies must approve options not specifically included in the UST regulation. EPA provided three additional options in its regulation that provide flexibility for owners and operators (primarily the Department of Defense) of FETs greater than 50,000 to meet the release detection requirements.

In summary, EPA's main points of emphasis are: That operators know how their UST system works, what to do in case equipment fails and what their responsibilities are; That UST facilities are monitored daily and the necessary information is logged; That the equipment used for overfill and leak detection functions; That UST regulators are informed of changes at UST facilities; That all parts of a UST facility get reviewed because most leaks are found by people and not equipment. Tank Management Services, Inc. along with KDHE will be doing informative meetings on the new UST regulations in the coming months. Owners and operators will be notified by e-mail and the Advisor of dates and locations. Operator Training Kansas Department of Health and Environment (KDHE) requires all UST operators to be certified as level A/B operators within 30 days of taking over operation of a UST facility. Trained in 2010 or 2011 MUST RENEW BY DECEMBER 31, 2015. If you were trained in 2012 or after you must renew within four years of the EXACT DATE you were trained. You will find the full 2015 class schedule and registration on our website at www.tankmgmt.net. August 4 August 5 August 6 September 23 September 24 October 6 October 7 November 5 December 2 City Limits Convention Center Altir Room 2227 S Range Colby, KS Fort Hays State University Memorial Union, Trails Room 217 600 Park Street Hays, KS Atrium Hotel & Conference Center 1400 N Lorraine Hutchinson, KS Hilton Garden Inn Conference Center, Konza Prairie Room 410 South 3rd Street Manhattan, KS The Eldridge Hotel Crystal Ballroom 701 Massachusetts Lawrence, KS Best Western Wichita North Regency III 915 East 53rd Street North Wichita, KS Salina BiCentennial Center Room 203 800 The Midway Salina, KS Crowne Plaza Hotel KC/Overland Park 12601 West 95th Street Lenexa, KS Kansas Soybean Association Board Room 1000 SW Red Oaks Place Topeka, KS

Clerks and Attendants Must Be Trained Information on level C training for all clerks and attendants may be found in the manual or on the CD received by A/B operators. A Level C certificate is available at www.tankmgmt.net. Mouse over the UST Operator Training button on the left side of the home page. A menu will appear, left click Class C Certificate" then click on Level C Certificate. This will get you a printable certificate. All UST Level C personnel must be trained before they may begin working at the facility. WHAT IS TANK MANAGEMENT SERVICES? TMS provides loss control and risk management assistance to UST owners who have third party liability insurance through Great American Custom as part of the Kansas Underground Storage Tank Liability Plan. TMS can provide you with information on USTs leak detection methods, and Federal and State regulations. Call TMS toll free at 800-530-5683 during normal Central Time Zone office hours (8-5). In the Topeka area, please call 233-1414. On the web go to www.tankmgmt.net. David Engelken is available to answer your questions. This Service is free.