RSP Series. Round Spectra-Lyte Garage Light, watt HID / CF, QL available. Specifications - - -

Similar documents
A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

OP2 CosmoPolis Series

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812

ELA Low Wattage HID Series Element Acrylic High Bay, W HID

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

Floodlight. AF1000 Series. Aktra Cutoff Floodlight W HID

EAL Series. Effex Area Luminaire, W HID. Overall Dimensions. Specifications Approvals: Catalog Number: Date: Page 1 of 6

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP051A0712

ELG CosmoPolis / MasterColor Elite HID Series Element Enclosed Glass High Bay, watt

Overall Dimensions. Specifications

Overall Dimensions. Specifications

Induction Compact Fluorescent HID LPQ. Canopy Luminaire

ELMGR Compact Fluorescent Series Element Rodded Metal over Glass (glass lined) High Bay

F Series (available MF Series: Marine Listed with optional hazardous location listing)

PGL350P W PS Wallpack

Perimaliter Wallpacks

Applications. Standard Materials

Perimaliter Wallpacks

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

Lighting: Explosionproof Area HID. Applications. Standard Materials

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

Standard Grade 14 Inch Reflector. Ordering Information

Recessed. HP90 Fluorescent 1x4

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Recessed. HP90 Fluorescent 2x4

Applications. Standard Materials. Certifications and Compliances

Example: RBX15L840-UNV-WT ARR22L. Family Lumens Color Temperature Voltage Finish Options Optics

TORNADOTM BOLLARD PATENTS PENDING

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Garage & Canopy. SoftView. Parking with confidence

Applications. Standard Materials. Certifications and Compliances


AFL FLOODLIGHT SERIES

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

Healthcare. Multi-Med Patient Room Luminaire 2x4

KAD250MR3TBSPD04 Wall Fixture

Linear. TruGroove recessed micro

2LP3GA217R-33FL-UNV-1/2-EBHE-LPT835HL

Visor Compact Architectural LED Wallpack. Technical Specifications VISOR TM. Visor Configuration Information. Project Catalog Number Type Date

Linear. TruGroove recessed micro

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Example: DWAE51L840-4-UNV-MD360W. Lumen Package Color Temp. Length Voltage Driver Options Installed

Linear. TruGroove Recessed

Linear. TruGroove recessed

HP90 Recessed 2'X2' Fluorescent; T8, T5, T5HO or TT5

ILXVA IL Xtreme Vertic aisle ILXGHB Glass IL Xtreme High Bay ILXSB IL Xtreme Soft Bay ILXCB IL Xtreme Comfort Bay ILXLB IL Xtreme Low Bay Less Ballast

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)

Blank. UNV Universal voltage V V V V V V. General Distribution Narrow Medium Wide Aisle Double Asymmetric

MLCAN60LED50 CONSTRUCTION: 60W LED CANOPY LIGHT

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

performance & comfort

Dual Lamp Ceramic Metal Halide 3 Lumen Packages in 1 Luminaire

Voltage Driver Options DIM 0-10V 1% dimming SDIM 4 Step dimming to 40% input power XDIM 3,4 MarkX phase dimming DALI 5 DALI

2STG232-D-UNV-1/2-EBLHE-LPT835HL

Example: 2STG217-D-UNV-1/2-EBHE-LPT835HL. Ballast Config. Voltage V V V UNV Universal Voltage V

Linear. MicroSquare gen2 suspended

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

Voltage Driver Options UNV Universal voltage V V V V

Calculite LED 7" Downlight

Linear. FluxStream wraparound. 2', 4' and 8'

Linear. Jump Wall/Cantilever

Example: 1STG132-D-UNV-1/1-EBHHE-LPT835HL. Ballast Configuration V V V UNV Universal Voltage V

C A M B E RTM PATENTS PENDING

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) N Lightguide D 55% Down Kit G 80% Down Kit J 100% Down Kit

ORDERING INFORMATION: 120 Volts (120)

Linear. FluxStream strip

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.

Roadway. RoadView. Succeed in your roadway lighting design goals

Laredo Decorative Wallpack Family

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA

A R C H I T E C T U R A L WA L L L U M I N A I R E S E R I E S

FULL CUTOFF DARK SKY COMPLIANT FIXTURES. commercial & architectural lighting

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

LytePro. A Family of Architectural LED Luminaires. Solid State, Solid Solutions. Stonco is a Philips company

Industrial. LED high bay FBX. 8000, 12,000, 16,000, 20,000, 24,000, 36,000 or 45,000 lms

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) N Lightguide

SXPJ SERIES S X azz.com/rigalite

Cynergy Series Retrofit Kit

Linear. FloatPlane Suspended LED

Post Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109

S43X. elliptipar high lumen. uplights S432 S431 S433 S434 PRODUCT

SP Spot. G1 Gen-1 SF Slip Fitter Mount (fits to 2-3/8" O.D. tenon) RSP Rectangular Spot. YK Yoke Mount. A33 Asymmetric 33 Flood

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

KH Series Kemlux III Enclosed/Gasketed

Remodeler. Complete product = Frame-in kit + Adjustable light engine / Trim Order each separately

Run Length. Upper Optics. 04 4' 08 8' XX Total run length (4' increments) N Lightguide D 55% Down Kit G 80% Down Kit J 100% Down Kit

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

The Commercial/Industrial Collection. Parking Garage/Multi-Purpose Fixtures QMB

Transcription:

Catalog Number: Approvals: - - - Series/Source-Wattage Distribution Voltage (Optic Assembly / Refractor) Overall Dimensions For Reference Only RSP S (symmetric) acrylic refractor with internal reflector system Standard for HID units, available for CF units. A (asymmetric) acrylic refractor with internal reflector system Available for HID units only. 15.00 (38.10cm) 12.38 (31.43cm) 12.75 (32.39cm) 4.25 (10.80cm) 7.50 (19.05cm) 11.75 (29.85cm) RSP CF/QL R (symmetric) polycarbonate refractor Standard for CF and QL units. RG (symmetric) glass refractor Not available for 165W QL units. Weight 15.00 (38.10cm) unit with S, A and R optic unit with RG optic 12.00 (30.48cm) 20 lbs. (9.07 kgs) 30 lbs. (13.61 kgs) Specifications Options (Factory Installed) Accessories (Field Installed) Date: Page 1 of 10 Housing / Finish Die-cast aluminum alloy construction shall ensure durability within parking structures. Standard finish is Textured Satin Aluminum UltraClad polyester powder coat, electrostatically applied and oven cured. Other colors may be specified. Construction and finish of the housing and all exterior hardware shall ensure fixture is resistant to the effects of corrosives and contaminants such as exhaust fumes. Easy Hanger Plate and internal component mounting brackets shall be fabricated from pre-galvanized steel. Standard HID unit constructed to IP54. Standard QL/CF unit constructed to IP52. Optic Assembly Symmetric (S) or Asymmetric (A) Optic Assembly: Enclosed and gasketed optical assembly shall have an internal reflector system with upper and lower apertures for controlled downlight with uplight component. Reflector shall also shield the arc tube to sharply restrict discomfort and disabling glare. Downlight component shall have Type V Round distribution with sharp definition and high peak angles to give wide spacing and high uniformity while avoiding glare in visual zones. ADL (Additional Downlight) option available, useful for higher footcandle requirements of entry/egress areas. Upper aperture shall produce a symmetrical, upward light component that provides fill light on ceiling surfaces. Primary reflector shall be fabricated from specular, high purity, anodized aluminum that is fixed within lens interior for proper photometric alignment. Secondary, upper reflector shall be fabricated from specular, high purity, anodized aluminium and shall redirect high angle light back to the primary reflector and useful beam. Symmetric Round Refractor (R): For CF source fixtures, precision refractor is made from UV stabilized acrylic, with a Reflector/Refractor option available. With long-life QL lamp sources, a high impact polycarbonate refractor is standard. Symmetric Round Glass Refractor (RG): Glass Refractor available for HID, CF, and QL units. Lens S or A Optics: Injection-molded, UV stabilized, high impact acrylic lens (with symmetric or asymmetric reflector) shall be enclosed and gasketed for optimal performance. R Optics: An injection-molded, UV stabilized, polycarbonate lens is standard with CF and QL lamp sources, and is optional on other wattages (not recommended with 175-200W metal halide lamps). RG Optics: Molded glass lens may be specified. Ambient temperature restrictions apply. Suitable for use with HID, CF and 85W QL units in 55 C (131 F) ambients. 100W max HID units are suitable for use in 65 C (149 F) ambients. Lamp / Socket The socket shall be porcelain, with spring-pressure center contact, 4KV pulse rated. Medium base HID lamps. Socket shall mount directly to the upper reflector to assure proper photometric alignment with the optical system. In QL induction units, the lamp and lamp holder are preassembled and integral. CF unit luminaires utilize T4/PLT4 Compact Fluorescent lamps and GX24q-4/5 sockets. Ballast HID Units: Standard magnetic ballast shall be high power factor with reliable starting at temperatures as low as -34 C (-30 F) for Pulse Start Metal Halide and -40 C (-40 F) for High Pressure Sodium. Crest factor does not exceed 1.8. Ballast has Class H, 180 C (356 F) rated insulation system. Electronic Ballast option: Available for 150-70W Pulse Start Metal Halide units and some feature optional low voltage (0-10v) dimming capability. CF / QL Units: Ballast is high frequency electronic type, with Total Harmonic Distortion of less than 10% with reliable starting at temperatures as low as -40 C (-40 F) for QL, and -30 C (-22 F) for CF. Mounting Standard mounting shall include a galvanized steel Easy Hanger Plate with universal provisions for 4 junction boxes. An external set screw allows the fixture to be locked or removed without fixture disassembly. Optional tamperproof screws available. Threaded hubs are optional for pendant mounting to ¾ rigid conduit or direct surface mounting with feedthrough wiring. Yoke mount also available, as well as a wall mount bracket (with or without surface conduit box). Listings Luminaire is ETL listed to the UL standard, UL 1598, suitable for Wet Locations and 40 C (104 F) ambients. RSPQL-85 watt, 120-277V unit is rated for 40 C (104 F) ambients. RSPQL-85 watt, 480V unit is rated for 30 C (86 F) ambients. RSPQL-165 watt unit is rated for 25 C (77 F) ambients. The quality systems of this facility have been registered by UL to the ISO 9001 Series Standards. See current RSP-HAZ spec sheet WLSP0119 for IP65 Dust-Tite, UL 844 Hazardous Location listed unit. Warranty / Terms and Conditions Gardco luminaires feature a 5 year limited warranty. See Warranty Information on www.sitelighting.com for complete details and exclusions.and Conditions of Sale (keyword: terms). Hg Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small amounts of mercury. Such lamps are labeled Contain Mercury and/or with the symbol Hg. Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycle and disposal can be found at www.lamprecycle.org. - Finish G200-126 07/14 page 1 of 10 www.philips.com/luminaires

Energy Independence Security Act RSP Series RSP Page 2 of 10 S / A optic (standard HID unit) R / RG optic Series / Source - Wattage Distribution (optics) Voltage E ballast options Pulse Start Metal Halide RSPP-70 4 RSPP-100 RSPP-150 RSPP-175 RSPP-200 High Pressure Sodium RSPS-70 4 RSPS-100 RSPS-150 Compliant Pulse Start Metal Halide Compact Fluorescent RSPCF-242 RSPCF-426 RSPCF-432 RSPCF-442 QL Induction * RSPQL-85 RSPQL-165 * Ambient temperature limits apply at certain voltages. Contact factory. S Symmetric UV stabilized high impact acrylic lens, with internal reflector. Standard for HID units. Available for CF units. A Asymmetric UV stabilized high impact acrylic lens, with internal reflector. Available for HID units only. R Refractor (Symmetric) UV stabilized polycarbonate lens. Standard for CF and QL units. Consult factory for use with HID. Not recommended for 175-200 watt PSMH. RG Glass Refractor (Symmetric) Borosilicate glass lens. Not available in 165W QL. 120 208 240 277 347 480 480V not available with Electronic HID ballast option (70-150W PSMH only). QV Quad voltage ballast (HID sources only). Allows field selection of 120/208/240/277 voltage. 120-277V For units with electronic ballast: CF units or HID units with E option. Electronic Ballast (available for 70-150W PSMH units only, not available in 480V) E Electronic Ballast (mfg. of electronic ballast not specified) E1 4 Metrolight electronic ballast E4 Advance electronic ballast AD Analog dimming to 50% power (full range 0-50 dimming / requires 0-10V low voltage wiring) (leave blank for non-dimming ballast) Options (factory installed) Auxiliary / Emergency Lighting (available for HID only) Auxiliary Fluorescent Systems (not available with RG optics, limited to 175W units and below) CSRLF LF 1 Hot 55W HO circline restrike Hot/Cold 55W HO circline auxiliary lighting system with lamp LF1(XXX) Circline auxiliary lighting system (XXX) = specify voltage LF1-EBB Circline auxiliary lighting system with emergency battery backup LF-EBB 1 Hot/Cold 55W HO circline emergency lighting system with emergency battery backup Auxiliary Quartz Systems CSR Hot quartz restrike LQ Hot/Cold quartz restrike (100W max quartz lamp) LQ1 Separately wired (120V) quartz restrike (100W max quartz lamp) LQ2 LQ and LQ1 combined in the same fixture IP65 ADL BL ITS F1 F2 F3 BP TS VL NLMP No lamp CWA 50HZ Dust-Tite construction (to IP65) Additional down light (available for HID only) Bi-Level (available for HID only) Ignitor Turn-off switch (available for PSMH and HPS only) Single Fuse (120/277/347V) Specify voltage with QV or QL units. Double Fuse (208/240/480V) Specify voltage with QV or QL units. Double Fuse (208/240/480V) Specify voltage with QV or QL units. (Canadian double pull) Bulk packed Easy Hanger Plate Tamper resistant screws Polycarbonate lens Low wattage CWA ballast 50Hz ballast TW2 2 Thru-Wire provision Y PND-RC 3 Yoke mount Note: 1. LF and LF-EBB require the use of electronic ballasts. 2. EBB options not available with TW2 feed-thru wiring. 3. When unit is mounted to rigid conduit lengths over 12, PND-OJB accessory is required. Uses standard EZ Hanger plate mounting. 24 Leads option must also be specified. 4. E1 Metrolight ballast not available with 70W HID options. Pendant mounting for up to 12 rigid conduit lengths PND-RC-24LDS 3 Pendant mounting (with 24 leads) CF / QL exclusive options (not available for HID units) LMP(XX) Lamped (standard) (Specify XX = Color temperature code: 27 (2700K lamp, available for CF units only) 30 (3000K lamp, available for CF and QL units) 35 (3500K lamp, available for CF units only) 40 (4000K lamp, available for QL units only) If lamp color temperature is not specified with this option, RSPQL units are shipped with 40K lamps. 41 (4100K lamp, available for CF units only) If lamp color temperature is not specified with this option, RSPCF units are shipped with 41K lamps. (CF lamps shipped separately) SL Switch legs (available for CF units only) ZX Locking sockets (available for CF units only) EBB-DL-750-(XXX)-MT 1 (CF units only) Emergency battery backup, 750 lumens (damp location, manual test switch, remote mount) EBB-DL-1000-(XXX)-MT 1 (CF units only) Emergency battery backup, 1000 lumens (damp location, manual test switch, remote mount) EBB-DL-1000-(XXX)-ST 1 (CF units only) Emergency battery backup, 1000 lumens (damp location, self test switch, remote mount) (XXX) = specify voltage: 120 or 277V only Finish TSA Textured Satin Aluminum TDB Textured Dark Bronze TBK Textured Black TWHT Textured White TGR Textured Gray TGN Textured Green RAL(*) Specify Custom RAL color number Accessories (must be ordered separately) F1-KIT Single fuse kit (120/277/347V) F2-KIT Double fuse kit (208/240/480V) F3-KIT Double fuse kit (208/240/480V) (Canadian double pull) HSS House side shield (for use with S optics only) T2S Type 2 shield (for use with S HID non-eons optics only) BG Bird guard (pendant mounting required) (Satin Aluminum only) PND-OJB 2 WMB-RSP-NM-(X) WMB-RSP-SCB-(X) WMB-RSP-EZM-(X) Offset junction box Wall mount bracket to recessed wiring box or surface conduit box, by others (X = finish) Wall mount bracket with surface conduit box (X = finish) Wall mount bracket for mounting directly to EZ hanger plate (X = finish) WMB-RSP-EZM-SCB-(X) Wall mount bracket for mounting directly to EZ hanger plate, includes surface conduit box (X = finish) G200-126 07/14 page 2 of 10 www.philips.com/luminaires

Page 3 of 10 Distribution Guide & Ballast Data (1) Standard HID sources (optional low wattage CWA or electronic ballast data shown in italic) Source Catalog Lamp Reflector %.ies Ballast ANSI Line Current (5) Line Type (2) Number Envelope Type (3) Uplight SP/MH File Name Type (4) Code 120 / 208 / 240 / 277 / 480 Watts LER (6) RSPP-70 RSPP-100 S 12.3 5 rspp70s.ies HX-HPF M98 / M143 1.9 / 1.0 / 0.9 / 0.8 / 0.5 95 63 A 14.6 5.6 rspp70a.ies optional CWA M98 / M143 0.7 / 0.4 / 0.3 / 0.3 / NA 78 57 S 12.3 5 rspp10s.ies HX-HPF M90 / M140 2.8 / 1.4 / 1.4 / 1.2 / 0.6 130 48 A 14.6 5.6 rspp10a.ies optional CWA M90 / M140 1.1 / NA / NA / 0.5 / NA 128 60 optional electronic M90 / M140 0.9 / 0.5 / 0.5 / 0.4 / NA 113 PS RSPP-150 S 12.3 5 rspp15s.ies HX-HPF M102 / M142 3.7 / 2.1 / 1.8 / 1.6 / 1.0 185 41 A 14.6 5.6 rspp15a.ies optional CWA M102 / M142 1.7 / NA / NA / 0.8 / NA 189 37 optional electronic M102 / M142 1.4 / 0.8 / 0.7 / 0.6 / NA 166 RSPP-175 RSPP-200 S 12.3 5 rspp17s.ies 48 CWA M137 / M152 2.0 / 1.1 / 0.9 / 0.8 / 0.5 220 A 14.6 5.6 rspp17a.ies 44 S 12.3 5 rspp20s.ies 50 A 14.6 5.6 rspp20a.ies CWA M136 2.2 / 1.3 / 1.1 / 1.0 / 0.5 232 45 RSPS-70 S 21.9 6 rsps70s.ies 49 A 15.0 6.5 rsps70a.ies HX-HPF S62 1.7 / 1.0 / 0.9 / 0.8 / 0.6 94 44 HPS RSPS-100 S 21.9 6 rsps10s.ies HX-HPF S54 2.3 / 1.4 / 1.1 / 1.0 / 0.8 130 54 A 15.0 6.5 rsps10a.ies optional CWA S54 1.2 / NA / 0.7 / 0.5 / 0.3 138 48 RSPS-150 S 21.9 6 rsps15s.ies HX-HPF S55 3.2 / 1.7 / 1.6 / 1.4 / 0.7 195 62 A 15.0 6.5 rsps15a.ies optional CWA S55 1.7 / NA / 0.9 / 0.7 / 0.5 190 55 Compact Fluorescent source Source Catalog Spacing Min. Max. (9) Lamp (10).ies Line Current (5) Line Type (2) Number Lamping Criteria Starting Ambient Life in hrs. File Name 120 / 220-240 / 277 Watts LER (6) CF RSPCF-242 2X42W CF 2.0-30 C 40 C 15,000 rspc242(*).ies 0.7 / 0.4 / 0.3 90 63 RSPCF-426 4X26W CF 2.1-30 C 40 C 15,000 rspc426(*).ies 0.9 / 0.5 / 0.4 104 59 RSPCF-432 4X32W CF 2.1-30 C 40 C 15,000 rspc432(*).ies 1.0 / 0.5 / 0.4 128 64 RSPCF-442 4X42W CF 2.1-30 C 40 C 15,000 rspc442(*).ies 1.5 / 0.8 / 0.6 168 65 QL Induction source Source Catalog Spacing Min. Max. (9) Lamp (10).ies Line Current (5) Line Type (2) Number Lamping (8) Criteria Starting Ambient Life in hrs. File Name 120 / 208 / 240 / 277 Watts LER (6) QL RSPQL-85 85W QL 1.6-40 C 40 C (120-277V), 30 C (480V) 100,000 rspq85r.ies 0.8 / 0.5 / 0.4 / 0.3 85 62 RSPQL-165 165W QL 1.6-40 C 25 C 100,000 rspq165.ies 1.5 / 0.8 / 0.7 / 0.6 165 63 1) The RSP Series accommodates a variety of other wattages and lamps. Consult factory. 2) PS = Pulse Start Metal Halide, HPS = High Pressure Sodium. Clear lamps recommended. CF = Compact Fluorescent, QL = QL Induction. CF and QL source use coated lamps. 3) Standard HID reflector types: S = Symmetric, A = Asymmetric. (to specify RG or R refractor with HID source, consult factory. ) Standard CF and QL reflector type: R = Symmetric polycarbonate refractor. S reflector system is available with CF source. (replace (*) with chosen CF reflector type) 4) CWA = Constant Wattage Autotransformer, HX-HPF = High Reactance High Power Factor. Consult factory for other HID ballast types and additional CF and QL information. 5) 208V, 240V, 480V and QV units available. Consult factory. 6) LER = Luminaire Efficacy Rating. Calculated in accordance wtih NEMA Standard LE-5B for standard ballast. For PSMH 70-150W LER values w/ optional Electronic or CWA ballast, consult factory. 7) Ambient temperature restrictions apply. Consult factory. 8) Data represents highest and/or most common lumen packages available for each reflector size. Note Maximum Ambients. Consult factory for information on specific lamping requirements. 9) Important: Ambient temperature guidelines must be followed. Operation in excess of Maximum Ambient temperatures will void luminaire warranty. Approximate C to F relationship is as follows: Max ambients: 25 C = 77 F, 30 C = 86 F, 40 C = 104 F. Minimum starting temps: -30 C = -22 F, -40 C = -40 F. 10) Lamp life based on 50% mortality rate at 10 hour starts. G200-126 07/14 page 3 of 10 www.philips.com/luminaires

Page 4 of 10 Option details (Factory Installed) Auxiliary / Emergency Lighting (available for HID units only) Photometric Data Comparison Reveals Uniformity of Light with T5HO Circline Auxiliary / Emergency Lighting System. (Garage lighting application viewed from above showing relative footcandle levels on the floor and surrounding walls.) Litematic Operation (LF = LiteMatic Fluorescent / LQ = LiteMatic Quartz) quartz emergency lamp in typical garage fixture RSP with T5HO circline fluorescent lamp Normal Start: Main HID and auxiliary (T5HO Circline Fluorescent or Quartz) lamps both energized. Main Lamp Reaches Approximately 40% of Rated Output: Auxiliary (Fluorescent or Quartz) lamp automatically extinguishes. Combined lamp currents never exceed that of main lamp at 100% output. When Arc Extinguished: After power interruption, auxiliary (Fluorescent or Quartz) lamp is automatically energized when power is restored and remains on during run down, restrike and ramp up.. Main Lamp Reaches Approximately 40% of Rated Output: Auxiliary (Fluorescent or Quartz) lamp automatically extinguishes. Auxiliary Fluorescent Lighting Systems 1, 2 Fluorescent auxiliary lamp offers a high performance alternative to traditional quartz restrike systems. Advantages include 16,000 hr lamp life, 3800 lumens (55W), cooler operation resulting in safer lamp handling, and precise, round distribution for optimum photometric performance. CSRLF LF 3 LF1 (XXX) Note: LF1-EBB LF-EBB 3 Hot 55W HO circline restrike (no time delay) Hot/Cold 55W HO circline auxiliary lighting system with lamp Circline auxiliary lighting system (XXX) = Specify voltage. Requires an Interlock (by others) to ensure HID and fluorescent source are not operated together. Emergency Battery Backup options LF1-EBB and LF-EBB are not available with TW2 feed-through luminaire wiring. Circline auxiliary lighting system with emergency battery backup Hot/Cold 55W HO circline emergency lighting system with emergency battery backup Notes: 1. RSP-LF options are limited to 175 watt and below (HID non-eons RSP units). CSRLF: LF: LF1: Circline Fluorescent restrike using a current sensing relay. Activation: At cold start / restrike, through Run Down. Extinquishes once main HID lamp strikes / restrikes. Provides LiteMatic T5HO Circline Fluorescent auxiliary operation for fixtures with 120V or multi-tap ballasts. Activation: At cold start / restrike, through run down, restrike and ramp up. Extinquishes after HID lamp reaches approximately 40% light output. Separately wired, externally controlled Circline Fluorescent Emergency Lighting from an auxiliary power source (generator, inverter, UPS). Activation: Emergency (Black Out) conditions only. Extinquishes when main power is restored. LF1-EBB: Provides factory supplied, externally mounted Emergency Battery Backup (EBB) to power the circline fluorescent lamp. Activation: Emergency (Black Out) conditions only. Extinquishes when main power is restored. LF-EBB: Provides LiteMatic Circline Fluorescent auxiliary operation and includes factory supplied, externally mounted Emergency Battery Backup (EBB) to power the circline fluorescent lamp. Activation: At cold start / restrike, through run down, restrike and ramp up. Extinquishes after HID lamp reaches approximately 40% light output. 2. Not available with RG optics. 3. LF and LF-EBB requires the use of electronic ballasts. auxiliary power source Auxiliary Quartz Lighting Systems Notes: Standard 100 watt (120V) double contact bayonet base socket. Combined Quartz wattage may not exceed HID lamp wattage. Requires 5-wire. LQ1 and LQ2 require an Interlock (by others) to ensure HID and Quartz source are not operated together. CSR LQ LQ1 LQ2 Hot quartz restrike (no time delay) (100W quartz lamp max) Hot/Cold quartz restrike (100W quartz lamp max) Separately wired (120V) quartz restrike (100W quartz lamp max) Requires an Interlock (by others) to ensure HID and quartz source are not operated together. LQ and LQ1 combined in the same fixture CSR: LQ: LQ1: LQ2: Quartz restrike using a current sensing relay. Activation: At cold start / restrike, through Run Down. Extinquishes once main HID lamp strikes / restrikes. Provides LiteMatic Quartz auxiliary operation for fixtures with 120V or multi-tap ballasts. Activation: At cold start / restrike, through run down, restrike and ramp up. Extinquishes after HID lamp reaches approximately 40% light output. Separately wired, externally controlled Quartz Emergency Lighting from an auxiliary power source (generator, inverter, UPS). Activation: Emergency (Black Out) conditions only. Extinquishes when main power is restored. Combines the standard LQ and LQ1 systems to provide the ultimate in safety and security. Activation: 1) At cold start / restrike, through run down, restrike and ramp up. Quartz lamp is extinguised after HID lamp reaches approximately 40% light output. 2) Emergency (Black Out) conditions only. Extinguishes when main power is restored. auxiliary power source G200-126 07/14 page 4 of 10 www.philips.com/luminaires

Page 5 of 10 Option details continued (Factory Installed) IP65 Dust-Tite construction May be specified with standard junction box (by others) when unit is pendant mounted (PND-RC or PND-RC-24-LDS option, or PND-OJB accessory) or with direct surface mounting and feed-thru wiring (TW2). IP65 option with standard easy hanger plate mounting requires the use of weatherproof wiring connectors or weatherproof junction box (by others). ADL Additional down light Note: Available for HID units only. Modified upper reflector focuses more light downward. Useful in meeting 50 fc minimum entry zone requirements of parking garages. BL Bi-Level (Hi/Low dimming) Note: Available for HID units only. Provides High / Low level of lamp output to 50% power. Zero crossover network avoids strobing and lamp dropout. Bi-level dimming is suitable for HPS in all wattages. Metal halide dimming below 100W is not recommended due to noticeable color shift. HIGH LOW ITS Ignitor Turn-off switch Note: Available for PSMH and HPS HID units only. For preventing damage to the ballast at PSMH and HPS lamp end-of-life. Disconnects ignitor within seven minutes if a lamp has failed. F1 Single fuse (120V / 277 / 347V) 1 KTK 30 amp fuse mounted internally on the ballast plate. F2 Double fuse (208V / 240V / 480V) F3 Double fuse (208V / 240V / 480V) (Canadian double pull) 2 KTK 30 amp fuses mounted internally on the ballast plate. Note: Fusing options require that voltage must be specified with QL units or HID units ordered with QV ballasts. F1 F2 F3 BP Bulk packed Easy Hanger Plate For job site installation prior to scheduled fixture arrival. TS Tamper resistant screws Provides an additional level of security by inhibiting unauthorized access. VL Vandal resistant polycarbonate lens Impact resistant polycarbonate lens is less prone to vandalism. Covered by a 1 year factory warranty. Note: May be specified on HID units with S or A optic in 150 watt and below only. Polycarbonate refractor (R) is standard on QL units. NLMP No lamp Specified if lamps are to be provided by others. CWA Low wattage CWA ballast Provides improved voltage regulation and reduces current draw. Available for 70W, 100W and 150W HID only. 50HZ 50 Hz ballast operation Specified for applications (outside the United States) where 50 Hertz operation is standard. G200-126 07/14 page 5 of 10 www.philips.com/luminaires

Page 6 of 10 Option details continued (Factory Installed) TW2 Thru-wire provision Feed-thru wiring for direct surface mounting to 3/4 conduit. Y Yoke mount Specified as an alternative to pendant mounting, especially for sloped ceilings. Yoke provides rigidity as well as adjustable mounting height and routing of SO cord (provided by others). PND-RC Pendant mounting 3/4 threaded hub allows mounting to rigid pendant lengths up to 12. (Junction Box by others) Standard supply wiring connection for PND-RC is made inside fixture and requires removal of lens and reflector pan. For external wiring to ceiling mounted junction box, specify PND-RC-24LDS. Note: For mounting to conduit lengths greater than 12, standard unit s EZ Hanger plate mounting is required along with separately ordered PND-OJB accessory. PND-RC-24LDS Pendant mounting with 24 leads 24 leads supplied for external wiring to ceiling mounted junction box. 3/4 threaded hub allows mounting to rigid conduit. (Junction Box by others) Note: If installation requires longer leads, contact factory to specify custom length leads. Note: For mounting to conduit lengths greater than 12, standard unit s EZ Hanger plate mounting is required along with separately ordered PND-OJB accessory. G200-126 07/14 page 6 of 10 www.philips.com/luminaires

Page 7 of 10 Option details continued (Factory Installed) CF / QL Exclusive Options LMP(XX) Lamped (Standard) (XX) = Specify CF or QL lamp color temperature Compact Fluorescent QL induction 27 2700K Lamp 30 3000K Lamp 30 3000K Lamp 40 2 4000K Lamp 35 3500K Lamp 41 1 4100K Lamp 1. If lamp color temperature is not specified with this option, RSPCF units are shipped with 41K lamps. CF Lamps shipped separately. 2. If lamp color temperature is not specified with this option, RSPQL units are shipped with 40K lamps. CF Exclusive Options SL Switch legs Provides energy savings by allowing selective operation of each of the 2 electronic ballasts. Note: Available for CF units only. Field selection and connection required. See installation instructions. ZX Note: Available for CF units only. Locking sockets Ensures compact fluorescent lamps will remain securely in the socket. Useful in areas that experience elevated levels of vibration. Notes: EBB options are available for CF units only. Not available with TW2 feed-thru luminaire wiring option. Remotely mounted emergency battery backup. Suitable for Damp Locations. Includes two 24 sections of 3/8 flex conduit, charging indicator light, and a manual test switch. (Self test switch available on 1000 Lumen unit only.) Mounting dimensions depend on ballast type. Consult factory. Luminaire AC power in EBB AC power in EBB-DL-750-(XXX)-MT Emergency battery backup, 750 lumens, manual test switch (XXX) = Specify CF unit voltage: 120 or 277 only. EBB-DL-1000-(XXX)-MT Emergency battery backup, 1000 Lumens, manual test switch (XXX) = Specify CF unit voltage: 120 or 277 only. EBB-DL-1000-(XXX)-ST Emergency battery backup, 1000 Lumens, self test switch (XXX) = Specify CF unit voltage: 120 or 277 only. Remote Mount Emergency Battery Backup G200-126 07/14 page 7 of 10 www.philips.com/luminaires

Page 8 of 10 Accessory details (Field Installed - Shipped Separately) F1-KIT Single fuse kit (120V / 277 / 347V) Note: Voltage must be specified. 1 KTK 30 amp fuse and fuse holder for field installation F1-KIT F2-KIT Double fuse kit (208V / 240V / 480V) Note: Voltage must be specified. F2-KIT Double fuse kit (208V / 240V / 480V) (Canadian double pull) Note: Voltage must be specified. 2 KTK 30 amp fuses and fuse holder for field installation F2-KIT F3-KIT HSS House side shield ( S optics only) Restricts spill light onto adjacent areas. T2S Type 2 shield (for HID non-eons S optics only) Type II Asymmetric shield. Supplemental reflector converts the distribution to an elliptical rather than a concentric pattern. BG Bird guard (requires pendant mounting) Inhibits nesting which may cause overheating of fixture. Available in Satin Aluminum only. PND-OJB Offset junction box 3/4 threaded hub allows mounting to free-swinging or rigid pendant lengths greater than 12. (used with standard EZ Hanger plate) G200-126 07/14 page 8 of 10 www.philips.com/luminaires

Page 9 of 10 Accessory details continued (Field Installed - Shipped Separately) WMB-RSP-NM-(X) Wall mount bracket to recessed wiring box or surface conduit box (by others) (X) = Specify finish 2.5 (6.35cm) square mounts with (4) 1/4 fasteners (by others) May also be pendant mounted with coupler and rigid conduit (by others). May require customer supplied pendant mounted conduit box, depending on pendant length and desired mounting method. mounts to surface conduit box or recessed wiring box mounts to adapter plate with 3/4 NPT nipple (-NM) Unit with PND-RC option mounted directly to adapter plate Unit with PND-RC option mounted directly to adapter plate WMB-RSP-SCB-(X) Wall mount bracket with surface conduit box (X) = Specify finish surface conduit box detail supplied with wall bracket 3.63 (9.21cm) 11/32 dia. thru hole (4 places) 3.63 (9.21cm) 3/4 NPT threaded conduit hub (5 places) Unit with PND-RC option mounted directly to adapter plate WMB-RSP-EZM-(X) Wall mount bracket for mounting directly to EZ hanger plate (X) = Specify finish EZ hanger plate PND-OJB WMB-RSP-EZM-SCB-(X) Wall mount bracket with surface conduit box for mounting directly to EZ hanger plate (X) = Specify finish Direct mount WMB-RSP-EZM-(X) accessory shown. For wall mount bracket accessory with surface conduit box, specify WMB-RSP-EZM-SCB-(X). G200-126 07/14 page 9 of 10 www.philips.com/luminaires

Energy Independence Security Act RSP Series Notes Page 10 of 10 Compliant Pulse Start Metal Halide Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. G200-126 07/14 page 10 of 10 www.philips.com/luminaires Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ 08873 Tel. 855-486-2216 Imported by: Philips Lighting, A division of Philips Electronics Ltd. 281 Hillmount Rd, Markham, ON, Canada L6C 2S3 Tel. 800-668-9008