COMPASS MODULE INSTALLATION & OPERATION MANUAL RMI ROCKY MOUNTAIN INSTRUMENT PO BOX 683 THERMOPOLIS, WY 82443

Similar documents
OASIS. Standby Instrument System. Installation Manual. Aerosonic Corporation September 18, N. Hercules Ave. Clearwater, FL USA

Attitude And Direction

ECT Display Driver Installation for AP2 Module

Caution Notes. Features. Specifications. Installation. A3 3-axis Gyro & Stabilizer User Manual V1.0

Recommended Practices for Installation for EC Directive 2014/30/EU Relating to EMC

JMW 10 AND 12 Tonearms

SWII Users Manual. Intercomp Co County Road 116 Minneapolis, MN (763) Fax

ALM-Inline. Accurate Lambda Meter V1.1.2 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

Quick user guide for the DM dispenser

Speakers and Motors. Three feet of magnet wire to make a coil (you can reuse any of the coils you made in the last lesson if you wish)

I.E.S. Cristo Del Socorro de Luanco. Magnetism

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

Marine Exhaust Temperature Alarm. COMPONENTS

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

$3-5/speaker 60 min Magnet Wire - Sandpaper

ilevil 2 AW Wireless Integrated Avionics Module AD-AHRS, GPS, ADS-B 978 / 1090 MHz Receiver Instruction Manual

Read Chapter 8 Servicing Machine in the Manual for general guidelines

Intercomp. PT300 Users Manual. Manual #: E

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

Wired Real Time GPS Installation Instructions

Manifold QF. Contents. Description. Installation & Setup Guide. Safety 3. Introduction 3. Installation Standards 4. Specifications 5.

IMPORTANT. Tools Needed: (depending upon vehicle) Phillips Screwdriver. Drill & Bit Set. Wire Stripper/ Crimp Tool

Connecting the rear fog light on the A4 Jetta, while keeping the 5 Light Mod

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

Competition Electronics, Inc

RoughDeck TM FXB Flexure Base Floor Scale. Installation/Operation Manual

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

INSTRUCTION MANUAL G-550

Triple Output Power Supply

K&L MC200 ELITE WHEEL BALANCER Product Manual - MC Wheel Balancing

Atomic Absorption Spectroscopy

Installation & Calibration

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

Solid-State Compass with GPS Receiver

Installation and User Manual. with RAIN SENSOR.

Application Note. Monitoring Bearing Temperature with ProPAC

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

LV101 DCC Power Station

PIECAL 520B & 521B Thermocouple Source Operating Instructions

µmonitor Operations & Programming Manual

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

Crane Systems GREER COMPANY. LALT 1151L System for Lattice Cranes. Installation and Calibration Manual. 1 of 39

NORTHERN ILLINOIS UNIVERSITY PHYSICS DEPARTMENT. Physics 211 E&M and Quantum Physics Spring Lab #6: Magnetic Fields

VG700AA User s Manual

VECTRIX VX-2 SERVICE MANUAL. Version 1.0/May 2011 VECTRIX, LLC

Owner s Manual. MG2000 Speedometer IS0211. for use with SmartCraft Tachometer

Reliant Series Floor Scale

Simple Free-Energy Devices

Wind display type WSDI-2

Model 1100B CHG Terminator. Installation Instructions

EXPERIMENT 13 QUALITATIVE STUDY OF INDUCED EMF

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

ATTITUDE AND DIRECTION

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Steering Angle Sensor (SAS) Replacement on Vehicles Equipped with Electronic Stability Control (ESC)

Electricity. Chapter 20

1.0 Features and Description

INSTALLATION AND OPERATION INSTRUCTION

ArchWeigh 2000 Conveyor Belt Scale Weigh Idler For Single or Multiple Scale Bases

EDG6000 Electronic Digital Governor

RESISTIVITY MONITOR/CONTROLLERS

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

GTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications.

LCD Annunciator Installation Instructions

LTX RF LEVEL SENSOR. Instruction Manual

NOTE: THESE PROCEDURES ARE THE SAME AS BEING IN THE SERVICE MODE. NOTE: ONCE THE UNIT IS POWERED DOWN THE VALUES FOR C4 WILL BE GONE.

Control Panel...3 Special Key Functions...4 Switching From Grams to Ounces...4 Calibration...5 Automatic Gauge Calibration...11

Model LE-300C/LH-300C/LZ-300C Coating Thickness Tester. Operating Manual

INSTALLATION AND OPERATION MANUAL FOR MCH-GPS17 GPS Compass and Ambient Temperature Gauge. NUTS (x3) 1 +12V TEMP SENSOR

Armature Reaction and Saturation Effect

PDC PROPELLER DE-ICE CONTROLLER

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2

Easy-On Wireless Tail Lights User s Guide

DCC-2500 Digital Climate Control for Vintage Air GEN-IV systems

FL-100-R (109) Operations and Installation Manual

Installation Guide. Enhanced Easy-Stop Trailer ABS 2S/2M Standard with PLC Installation Instructions TP Revised 1 Technical Bulletin

Pressure & Vacuum Measurement. Series 356. Solutions MICRO-ION PLUS MODULES

MARINE STEERING COMPASS

Street-Lynx By. Reilly MotorSports, Inc. Installation Manual

Harris IRT Enterprises Digital Resistance Tester Model XP

***Before starting : view the Virtual tour located at c:/programs/msoffice/powerpointviewer And carry out the tutorials in the manuals supplied***

Note: If anything is damaged or missing, contact your customer representative immediately.

What is Electricity? Lesson one

Section 55 Chapter 6

Linear Shaft Motors in Parallel Applications

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

TIP SHEET T2352, T3396. Installation Tips for RS1 + EVO-ALL 1-BUTTON REMOTE STARTER FOR: Acura RDX PUSH-TO-START / AUTOMATIC

Installation Tips for your Remote Start system (for Toyota Camry & Prius C, ) Crimestopper RS0+ EVO-ALL T3468 rev#1.

6 Gauge Box Set IS0333

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

Service Procedure Note Note Note

INTECH Micro 2300-RTD6

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Spray Height Controller

MAGPOWR Spyder-Plus-S1 Tension Control

24 Jan 2017 SPRITE. VRM10 Digital Audio Variometer. Recorded alarm messages including undercarriage warning. Installation manual

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

Thanks to Phatty & BenTaylor200 for the S14a ECU pinouts Thanks to Bren for the S14a ABS ECU wiring. Written by john200 PDF by STiMPY

Stevens Type A/F Encoder. For Stand-Alone Encoder Part # AND Encoder Attachment Part # INSTRUCTION 90044

Transcription:

COMPASS MODULE INSTALLATION & OPERATION MANUAL RMI ROCKY MOUNTAIN INSTRUMENT PO BOX 683 THERMOPOLIS, WY 82443

Table of Contents Technical Specifications Physical... 1 Electrical... 1 Mechanical... 1 Installation What s Where?... 2 Mounting the Module... 3 Magnetic Fields... 3 Alignment... 4 Leveling... 4 Calibration Switch Access... 4 Calibration Light Access... 4 Operation Programming the FEncoder... 8 FEncoder Display Control... 8 Program the Serial Input Port... 9 Error Blinking... 9 Calibration Doing the 180"...10 Serial Data Output Format...11 Copyright 1998 Rocky Mountain Instrument Manual Dated 3/9/98 Rocky Mountain Instrument PO Box 683-202 Fremont Street Thermopolis, WY 82443 307.864-9300 http://rkymtn.com techsupport@rkymtn.com

Physical Size: Technical Specifications 2.5W x 3.3L x 1.2H inches 15.9W x 8.4L x 3H cm Installation What s Where? Weight: 3.75 ounces The compass module 105 grams housing is shown to the left. Electrical Operating Voltage: Operating Current: Output: +8 to +30 VDC less than 50ma RS232 RMI ROCKY MOUNTAIN INSTRUMENT (307) 864-9300 PO Box 683! 202 Fremont Street! Thermopolis, WY 82443 COMPASS MODULE! MODEL 303 The left or right edge of the housing plate should align with the roll axis of the aircraft just like the airplane on the label. Some label s mounting instructions mention the yaw axis in error. Orient module label up, using airplane figure. Align long side of Mechanical mounting plate with roll axis. Three holes in the housing Operating Temperature: -20EC to +70EC plate are to mount the F ACCESS TO CALIBRATION SWITCH housing. The two oblong Storage Temperature: -30EC to +90EC Compass heading loses accuracy when module is not holes allow the rear of the CAL LIGHT parallel to earths surface. See manual for details. housing to be adjusted left Operation Altitude: -2000 to +35000 feet and right to aid roll axis alignment. Accuracy: 2E RMS when level The calibration switch access hole is on top as shown on the label. CAL LIGHT The location of the calibration light is also shown on the label and the drawing to the left. The light is actually back inside the hole in the housing. 1 2

Mounting the Module Location of the module is not critical except for magnetic fields as will be described.. It can be mounted under a seat, in the tail or behind the instrument panel, for example. Things to keep in mind in determining the location are: 1) magnetic fields; 2) leveling the compass with the surface of the earth (during flight); 3) alignment of the compass along the roll axis of the aircraft; 4) room to access the calibration switch; and 5) being able to see the calibration light. All of these are detailed below. Magnetic Fields The compass module can calibrate for constant magnetic fields in the aircraft as long as they do not saturate the sensors (this takes some pretty strong fields). Static (unchanging) magnetic fields create "hard-iron" distortion (an example: the total aircraft itself). These fields can be mathematically modeled as a constant offset when they are always in the same place with respect to the compass. This means the compass module can compensate for hard iron in the aircraft because the compass module is within the aircraft. Note that the farther the compass module is from a source of a magnetic field, the better. Magnetic fields from sources which are not part of the aircraft system will interfere with the calculation of compass heading. Thus, the compass can calibrate for its host, but it cannot compensate for some other vehicle driving by or for a steel hanger. For example, the calculated heading can be thrown off a few degrees by a small car that drives about 10 feet away from the compass. The compass module cannot be calibrated for magnetic fields that are not static (such as a magnetic field change from a flap or gear motor). Its simple calibration routine also cannot compensate for "soft-iron" distortion, which is created by ferrous metals. In this case, soft iron is described as a big hunk of ferrous iron that changes its magnetic field depending on how it is aligned with the earth s magnetic field. Soft-iron materials distort the magnetic field in different ways when they point in different directions in the earth's field. If a compass is strapped to a piece of soft-iron and the compass/soft-iron combination is pointed in different directions, the compass measures different offsets from the soft-iron. With hard-iron, the compass measures a constant offset. The effect of soft-iron cannot be modeled as a constant. Therefore, the compass module needs to be as far away from sources of soft-iron distortion as possible -- even a few centimeters of separation can be helpful, as the strength of the field is inversely proportional to the square of the distance. Basically... stay away as far as possible from big hunks of metal. It is best to use brass, aluminum or non-magnetic stainless steel screws for mounting. You can test stainless screws with a magnet... they should not be attracted at all. Alignment Orient the Compass module using the aircraft icon on the label. Use either side of the mounting plate to align the housing with the roll axis of the aircraft. Note that the two mounting holes toward the tail are oblong to allow small adjustments in alignment before tightening the mounting screws. Leveling Another important requirement is keeping the base of the mounting flange of the compass module aligned parallel to the earth s surface when in normal cruise flight. Accuracy is degraded when the compass is tilted. You may wish to make provisions in the mounting to be able to shim up the nose or tail of the compass housing to adjust the housing about the pitch axis after checking actual level in cruise flight. CAUTION: Note that heading accuracy is degraded when aircraft is in a bank. Calibration Switch Access Note the location of the calibration switch access hole on top of the housing. A nonmagnetic tool will need to reach down thru the hole to the switch. The tool only needs to be long enough to reach through the hole an activate the switch about 1/4 inch. The switch is rubber-covered so do not use a pointed tool. If your location is such that it is impossible to access the switch, one of the wires that connect to the back of the microencoder can duplicate the calibration switch by being shorted to ground. This arrangement does require increased complexity of the wiring harness at the microencoder, however. Calibration Light Access It is nice to be able to see the calibration light to note the beginning and end of the calibration cycle (described later) even if you do have to use the wire harness instead of the internal switch to start and stop the calibration process. If the wire harness is 3 4

used, care must be taken in closing the calibration wire to ground to act as the switch an improper activation may look like two activations representing both the beginning and end of the calibration cycle. OTHER CABLE(S) COMPASS CABLE NUT HOUSING Wiring at the Compass Module Inserting the modular jack that is attached to the cable provided is the only wiring at the compass module. Wiring at the FEncoder APX 2.5" OF ELECT. TAPE NOT SHOWN The compass module cable contains six wires with these functions: white - ground black - power red - calibration, open=normal operation, grounded=calibration mode green - compass data yellow - baud rate, open = 9600 baud, grounded = 1200 baud bare - shield wire Normally, only the ground, power, data and shield wires are needed. If you can t get to the calibration switch directly on the compass module, you will need to make provisions to be able to switch the red lead to ground to operate the calibration mode. There are three wires connecting the compass module to the FEncoder: power, ground and serial data. All three connect to the 9 pin D-sub connector at the back of the FEncoder. ground/white connects to GND/pin1 power/black connects to OAT+/pin9 data/green connects to SI/pin7 Carefully strip back the insulation on the compass module flat cable. If there is ample room for the flat cable to go clear into the 9 pin D-sub housing (through the black strain relief nut), strip the insulation back about 1-1/2 inch. If the cables already going into the housing fill up the hole in the strain relief, then strip the insulation back about 3 inches. OAT- 5 REAR OF ENCODER 9 T2 4 8 3 T1 OAT+ AUDIO SI SO = SERIAL OUTPUT SI = SERIAL INPUT 7 14 28 V 2 6 1 GND SO TIEWRAP ABOUT HERE FOR STRAIN RELIEF Cut off the yellow baud rate wire. If you have access to the calibration switch on the compass module, cut off the red calibration wire. The drawing above shows the case when the compass module cable does not have enough room to go through the strain relief nut with the other cable(s) (stripped 3 inches). Only the four small, individual wires go through the strain relief nut. You need to keep the stripped end back far enough for the strain relief nut to slide far enough back from the housing to assemble. You should apply a thin wrap of black electrical tape to hold the compass module cable in place over the length shown because the main insulation of the compass module cable cannot be secured by the strain relief nut. Additionally, add a tiewrap around the tape and cables at the point shown to provide strain relief for the compass module cable.. If you re connecting the compass module wires to a previously wired D-sub connector, we recommend that you very carefully burn away (solder iron) about 1/4 inch of insulation on the OAT+ wire (pin9) and the GND wire (pin1) to bare the wire. Then wrap and solder the stripped end of the matching compass module wire around the bare wire, solder the two wires and then tape the junction. The final data wire needs to have a crimp terminal installed and plugged into pin7. If you are connecting the compass module wires at the same time as other wires, we recommend that you attach a crimp terminal to a one inch long wire for the OAT+ and GND connections. Then the wires from compass module and normal wires from outside can be arranged AS IF a wire-nut were to be applied, soldered and then taped. The shield wire will go under the relief nut with other shield wires to make contact with the metal shell. The drawing below shows how to install a crimp terminal onto the wires and into the D-sub housing. Solder the wire to the crimp terminal ONLY if you do not have access to a crimping tool. 5 6

INSERT FLATTENED PAPER CLIP OR SIMILAR TO REMOVE CRIMP TERMINAL INSERT CRIMPED WIRE/TERMINAL Programming the FEncoder Operation CRIMP AROUND WIRE & SOLDER CRIMP AROUND INSULATION.10 20-24 AWG The compass module obtains its power from the FEncoder so it is in operation whenever the FEncoder is operating. For the compass heading to appear in the FEncoder s serial output and/or on the display, the FEncoder must be programmed properly as described in the FEncoder programming manual. Pertinent programming information is also detailed in this section. For complete details, refer to the FEncoder programming manual. The program mode can be entered at any time when the FEncoder is operating in its normal mode, which is after test has cleared the display after the unit is turned on. Press and hold [ACK] and then press both [ALRT] & [DALT] until the display blanks and OPt appears in the lower left. The OPt is one of the 1st level menu choices. The control combination was chosen to be awkward so there is no possibility of entering program mode by mistake. FEncoder Display Control First decide whether you would like the compass heading to continuously appear in place of the digital portion of the VSI or only appear when the [DALT] switch is pressed and held. Continuing from above, press [DALT] to enter the options menu. brset will appear in the center of the display. Turn the [SET] knob counter-clockwise three clicks until HdGvt appears in the center. This selection controls the temporary display of compass heading in the VSI position. Press [DALT] to enter this menu. NO or YES will appear. Turn the knob either direction to select yes or no. The yes selection will enable showing the compass heading when the [DALT] switch is pressed. When the selection is as desired, press [ALRT] to leave this menu selection. Now turn the [SET] knob one click counter-clockwise and the center of the display will show HdGvP. This selection controls the continuous display of compass heading in the VSI position. Press [DALT] to enter this menu. NO or YES will appear. Turn the knob either direction to select yes or no. The yes selection will enable continuous showing of the compass heading. When the selection is as desired, press [ALRT] to leave this menu selection. Only one of the above choices should be yes. Both can be no, however. 7 8

Program the Serial Input Port Continuing from above, press [ALRT] again. Only OPt should be in the lower part of the display. Turn the knob counter-clockwise two clicks. SEr should appear in the lower left of the display. Press [DALT] to enter the serial port menu. OUtPt will appear in the center of the display. Turn the [SET] knob clockwise one click until InPUt appears in the center. This selection controls the function of the serial input port. Press [DALT] to enter this menu. Turn the knob until C-HdG appears. The serial input port is now set to receive data from the compass module. Press [ALRT] once. Turn the knob one click clockwise. baud will appear in the center of the display. Press [DALT] to enter this menu. Turn the knob until the proper baud rate is set. The compass module baud rate is 9600. If you have, for some reason, grounded the baud control wire so the compass module is operating at 1200 baud, then set the baud rate of the FEncoder to 1200. Note that this baud rate setting controls both the serial input and output ports... you can t mix the two. Press [ALRT] three times to return the unit to normal operation. If you have programmed the unit to show compass heading either continuously or temporarily in the VSI position, then test that the heading is being received. Even if you do not desire to show the heading on the display, whenever the compass module is attached the compass heading will be included in the serial output data if the selected output format contains a magnetic heading data block. Error Blinking Should the compass module fail, there are two error messages that may help in diagnosing the problem. Check the calibration light on the compass module and see if it is blinking. If so, determine if the blink rate is two times per second or four times per second. Doing the 180" Calibration After the compass module is installed and operating, point the aircraft in any convenient direction where you can determine a direction 180E in the opposite direction. Make sure the compass module is as level as possible. You will probably need to lift the tail of a tailwheel aircraft and set on an appropriate height block or jack. With the FEncoder and compass module turned on, press the calibration switch. The calibration light will come on and stay on even after releasing the switch. If the light goes out, you probably inadvertently pressed the switch twice. If that is the case, press the switch again so that the light stays on. Leaving the FEncoder and compass module operating (light still on), turn the aircraft 180E. You do not need to maintain level while turning the aircraft. Once level again, again press the calibration switch. The light will go off and stay off after releasing the switch. If the light comes back on, you may have inadvertently pressed the switch twice. In that case, you will need to start all over, although you don t need to turn the aircraft back to the first position... just use the current position as the first point. Delays are built into the calibration switch operation, so it is difficult and rare to press the switch twice. Note that the compass module will output heading information before, during and after calibration. It is up to the user to know that calibration has been performed. Once calibration is performed, the results are stored in a nonvolatile memory. You should only have to recalibrate if the compass module is moved or additional hard iron equipment is installed near the compass module. A blink rate of two times per second indicates that the internal CPU program is corrupted and the module must be sent for service. There is no correction. A blink rate of four times per second indicates that the internal nonvolatile memory is corrupted. The memory can be re-initialized, although doing so will result in loss of calibration. To re-initialize the memory, start with the FEncoder power off, then hold the calibration switch down and turn the power to the FEncoder back on. The calibration light will turn on. Then press the calibration switch twice more to activate the re-initialization. When complete, the light will go off. If the light again returns to the four per second blink rate, send the unit for service. Remember to recalibrate the compass. 9 10

Serial Data Output Format This section is provided for those users that are not attaching the compass module to the FEncoder. It details the serial output format from the compass module. All output is ASCII, 8 bits, 1 start bit, one stop bit and no parity. The baud rate is defaulted to 9600 but can be changed to 1200 by grounding the red wire attached to the compass module. The format is: $HCHDM,ddd.d,M*cc<cr><lf> Where: ddd.d is the compass heading in tenths of a degree from 000.0 to 359.9 degrees. cc is two nibbles representing the checksum. To check, perform an XOR of all bytes starting at H and ending with M, including punctuation. This value when XOR d with the checksum should equal zero. <cr><lf> are carriage return and linefeed 11