Silent centrifugal air heater hot water supply

Similar documents
V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

CENTRIFUGAL FAN COIL UNIT VCE

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

MegaBox Product-specific information

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

CYCLONE F 400 smoke extraction casing

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

INDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement.

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

Performance. Sound Levels. Impellers. Motors. Accessories

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Product Catalogue ARMONIA Providing indoor climate comfort

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

Prepared By : Checked By : Approved By : Page 1 out of 6

Carisma The Ultra Quiet Fan Coil

Vent-Axia Sabre Sickle Roof Fans (VSR)

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas!

VAV TERMINAL BOXES TYPE: BA BT

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Heat recovery units type GTDHR

NEW Slimpak EC Box Fan (SLPT EC)

Axial fans. What s more, non-stock models are normally available within two weeks.

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

AC Commercial Fans Edition. ErP ready

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

BRIZA 22 HYBRID HEATING & COOLING

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Fan coil unit NBS 100/150

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

DIRECT-AIR ILB / ILT Series Rectangular duct fans

CBP COMBIBOX CONCEPT. Configurations DESCRIPTION OF VENTILATION MODULES

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

Slot diffusers, Round duct diffusers. IMP Klima

Multi directional heating. Air heaters Model NOZ

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Mixed Flow Roof Fans (RMH)

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

STANDARD VENTILATION UNIT (VK)

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

VORTICENT C E RANGE Centrifugal fans

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

AXIAL FANS Catalogue CN0050C01 May 2008

Ocelot vertical fan coil unit

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

(Thin) (Ultrathin) Suspended Air-handling Unit

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

FCC DUCTABLE AIR TREATMENT UNIT

FRESH BREEZE FAN-FILTER UNIT TECHNICAL DATA

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

something new in the air Technical Bulletin

DATA & FACTS Unit Heaters MultiMAXX HE. Fresh Air for Commercial and Industrial Companies

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

NCF fans 50 Hz. Protection class IP 55

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

Mixed Flow Roof Fans (RMH)

MAJAX-2 GENERAL SPECIFICATION

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

42AM. Air heaters. product selection. the best solution for heating large spaces. ensures buildings warm up ultra-fast

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

CENTRIFUGAL IN-LINE FANS VENT Series

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Features: Available in horizontal and vertical units

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

The World Leading Air-conditioning Company

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes

Transcription:

Large range : 5 to 120 Flows : 900 to 14000 m 3 /h Numerous accessories Design integrating perfectly in public buildings USE Operation in zones ES and S Extra silent and silent Forced air heating for premises requiring a low sound level and a rapid heating capability. Particularly well adapted for large volume premises, the silentherme is the most rational solution for heating reception halls, gymnasiums, theaters, conference rooms, etc Operation in GV and TGV zone Large volumes and very large volumes. These air heaters are used for forced air heating of large industrial premises. Their utilization for heating through a largely dimensioned duct network is possible thanks to high flow/pressure. RANGE Operation in zone ES and S Extra silent and silent 5 sizes of units : Series 1-2 - 3-4 - 5 Air flow from 1000 to 7.100 m 3 /h Operation in GV and TGV zone Large volumes and very large volumes 5 sizes of units : series 1-2 - 3-4 - 5 Air flow from 1000 to 14000 m 3 /h CHOICE OF The choice of a silentherme must be done taking into account operating and structural parameters of the room to be heated : Volume, height, surface, shape, type of construction, insulation. Room purpose, fresh air admission or not, specific internal pollution, desired sound level, possible siting zone (obstacles, fresh air intakes). Heating purpose : total, per zone, protection (air curtain). Respect of regulation concerning : working premises (temperature, pollution) public buildings (temperature, air renewal, fire classification). CONSTRUCTION Casing Electrozinc coated sheet steel, enamalled, dark grey (RAL 7024) colour. All the panels are lined with glasswool protected against erosion. Access panel to the fan motor assembly and to the battery mounted on hinges. 1

Filtration (compulsory option) Operation in zone ES and S Extra silent and silent Type G 4 or type F 5. Operation in zone GV and TGV Large volumes and very large volumes Type G 1 or type G 4. Exchange coil The silenthermes are fitted with high efficiency coils allowing operation with low temperature fluids (heat pumps, condensation boilers). Easily dismountable without removing the silentherme. Manufactured in copper tubes and aluminium fins for hot water with a temperature equal to or lower than 120 C and for a working pressure equal to or lower than 8 bars. Made in copper tubes and aluminium fins for hot water with an inlet temperature equal to or lower than 120 C and for a working pressure equal to or lower than 8 bars. Supply piping Construction : hexagonal sleeves Position : Vertical units : on the left, facing the unit Horizontal units The side positions can be changed on site very quickly Fan Centrifugal type, double inlets, dynamically balanced action impeller Motor Mounted inside the casing, silent, 1 speed 3 ph. 230/400 V, 50 Hz, equipped with opening thermal protection. Operation in zone ES and S Extra silent and silent Fan motor assembly Suspended on resilient mounts Option : 2 speed motor ½ ratio. Transmission By trapezoidal belts/pulley(s). ACCESSORIES Numerous connection and mounting accessories. SELECTION The selection of a silentherme is done according to a heating capacity, an air flow and a static pressure (optional for ducts). This leads to the determination of : the series (1, 2, 3, 4 or 5) and the number of rows (1, 2 or 3) of the heating coil for obtention of the price. This defines the designation Example : Silentherme N 23 Series 2 Number of rows in heating coil Each standard unit can be fitted with main accessories: Air intake box No. 10-20 - 30 or 40. Air diffuser No. 1 or 2. 2

PRELIMINARY SELECTION OF THE SERIES ACCORDING TO THE AIR FLOW TO BE HANDLED Air flow (m3/hx1000) Static pressure available for ducts and accessories (Pa) Extra-silent operation Silent operation Large volume operation Very large volume operation 3

SELECTION TABLES - AIR FLOW RATE / HEATING CAPACITY Temperature + 12 C at inlet - Pressure 1013 hpa Air flow rate m 3 /h Range** m Motor power Sound level* db(a) Heating capacity Low pressure fluid 45-37 C 90-70 C 105-75 C Air outlet temp. C Extra-silent operation (ES) Heating capacity Air outlet temp. C Heating capacity 11 1130 3,2 20 7,5 32 8,3 34 12 1020 12 0,37 35 4,7 26 11,7 46 12,8 49 13 930 5,8 31 14,4 58 16,1 63 21 1680 4,1 19 9,6 29 10,5 31 22 1350 14 0,37 40 6,1 25 14,6 45 16,3 48 23 1250 7,5 30 18,6 56 20,7 61 31 2830 6,5 19 15,2 28 16,8 30 32 2480 18 0,55 44 10,2 24 24,5 42 27,2 45 33 2190 12,2 29 30,4 53 33,9 58 41 3950 9,0 19 21,4 28 23,3 30 42 3550 20 45 14,8 24 35,2 42 39,2 45 43 3250 17,9 28 44,2 52 49,7 57 51 5100 12,7 19 30,0 30 33,1 31 52 4630 22 43 20,4 25 49,1 44 55,0 47 53 4250 24,7 29 61,3 55 67,8 59 Silent operation (S) 11 1750 3,9 19 9,2 28 10,1 29 12 1600 16 0,37 44 6,3 24 15,2 40 16,7 43 13 1500 8,3 29 20,0 52 22,4 56 21 2600 4,9 18 11,7 25 12,8 27 22 2250 18 0,55 48 8,3 23 19,6 38 21,9 41 23 2000 10,5 28 25,7 50 28,4 54 31 3800 7,4 18 17,4 26 19,2 27 32 3400 22 49 12,4 23 29,6 38 32,2 40 33 3000 15,2 27 37,0 49 41,2 53 41 5600 10,5 18 24,9 25 27,3 27 42 5050 30 1,1 51 18,2 23 43,0 38 47,8 40 43 4550 22,7 27 55,6 48 61,0 52 51 7100 14,9 18 35,0 27 38,2 28 52 6550 32 1,1 49 25,2 23 60,0 39 66,7 42 53 6000 31,8 28 77,6 50 86,1 55 Air outlet temp. C Shaded power values correspond to commonly used units, well suited to room heating. * Sound level : pressure level at 5 m in a room with average reverberation, 200 m 2 Sabin. 311 assembly unit - directivity 2. ** for assembly unit 311, residual speed 0.25 ms 1 (equal temperature air blast) Correction table for other return air temperature Temperature of air at inlet C Coefficient correcteur 15 10 7 5 0 +5 +10 +12 +15 +18 +20 1,44 1,35 1,31 1,27 1,19 1,11 1,03 1,00 0,95 0,90 0,87 4

SELECTION TABLES - AIR FLOW RATE / HEATING CAPACITY Température + 12 C à l aspiration - Pression 1013 hpa Air flow rate m 3 /h Range** m Motor power Sound level* db(a) hot water 45-37 C Low pressure fluid hot water 90-70 C hot water 105-75 C P T P T P T Large volumes operation (GV) 11 2500 4,6 17 10,7 24 11,8 25 12 2300 24 54 7,8 22 18,2 35 20,2 37 13 2100 10,4 27 24,4 45 27,0 49 21 3800 5,8 17 13,7 22 15,2 23 22 3500 28 1,5 59 10,5 21 24,6 32 27,3 34 23 3100 13,9 25 33,0 43 36,5 46 31 6000 9,0 17 21,5 22 23,8 23 32 5400 36 2,2 62 15,7 21 37,0 32 41,0 34 33 4600 20,0 25 47,4 42 52,5 45 41 8500 12,6 16 29,4 22 32,6 23 42 7600 44 2,2 64 22,5 21 52,8 32 58,5 34 43 6600 28,6 25 68,0 42 75,0 45 51 11000 17,9 17 42,0 23 46,5 24 52 9600 50 3 64 31,1 22 73,0 34 81,0 36 53 8000 38,8 26 91,5 45 101,0 48 Very large volumes operation (TGV) 11 3300 5,2 17 12,1 22 13,4 23 12 3100 30 1,5 61 9,0 21 21,5 32 23,8 34 13 2800 12,3 25 29,3 42 32,4 45 21 5000 6,5 16 15,2 21 16,8 22 22 4400 35 2,2 64 11,8 20 27,6 30 30,6 32 23 3800 15,7 24 37,4 40 41,4 43 31 7800 10,0 16 23,3 21 25,8 22 32 6600 44 3 68 17,4 20 41,0 30 45,4 32 33 5000 21,1 25 49,5 40 54,8 43 41 10500 13,6 16 32,1 21 35,6 22 42 9000 49 4 70 24,5 20 57,5 30 63,7 32 43 7500 31,0 24 73,5 40 81,4 43 51 14000 19,8 16 46,4 22 51,4 23 52 12400 60 5,5 70 35,1 20 83,5 31 92,4 33 53 10600 45,6 25 108,0 41 119,6 44 Column P : heating power in - Column T : air outlet temperature in C Shaded power values correspond to commonly used units, well suited to room heating. * Sound level : pressure level at 5 m in a room with average reverberation, 200 m 2 Sabin. 311 assembly unit - directivity 2. ** for assembly unit 311, residual speed 0.25 ms 1 (equal temperature air blast) Correction table for other return air temperatures Temperature of air at inlet C Coefficient correcteur 15 10 7 5 0 +5 +10 +12 +15 +18 +20 1,44 1,35 1,31 1,27 1,19 1,11 1,03 1,00 0,95 0,90 0,87 5

SELECTION GRAPHS (CASE OF DUCT NETWORKS) Static pressure drop (Pa) Air flow rate (m 3 /h x 1000) Static pressure drop (Pa) Extra-silent operation Silent operation Air flow rate (m 3 /h x 1000) Large volume operation Very large volume operation Example of sélection You wish to use a silentherme Series 1 N 11 with an air flow of 1000 m 3 /h mounted on a duct network whose pressure drop is 80 Pa. The internal pressure drop of the silentherme N 11 is 43 Pa with a G4 standard filter. The selected model is a zone S unit, motor 0.37. The selection can be optimized by the use of a software for calculation, contact our agency. 6

SELECTION GRAPHS (CASE OF DUCT NETWORKS) Static pressure drop (Pa) Air flow rate (m 3 /h x 1000) Static pressure drop (Pa) Air flow rate (m 3 /h x 1000) Extra-silent operation Silent operation Large volume operation Very large volume operation 7

SELECTION GRAPHS (CASE OF DUCT NETWORKS) Static pressure drop (Pa) Air flow rate (m 3 /h x 1000) Extra-silent operation Silent operation Large volume operation Very large volume operation ELECTRICAL CHARACTERISTICS OF THREE PHASE 400 V - 50 HZ MOTORS 0,37 0,55 1,10 1,50 2,20 3,00 4,00 5,50 IN in A 1,12 1,65 2 2,5 3,6 5,1 7,2 9,1 11,9 * Indicative values as per motors manufacturers present catalogue. The protection devices dimensioning is calculated according to the values indicated on the data plate affixed to the unit. 8

Units with transmission without filter cell 1 speed motor Series 1 2 3 4 5 S ES S GV TGV 11 B320021 B320196 B320919 B321087 12 0,37 B320048 0,37 B320218 B320927 1,1 B321095 13 B320056 B320226 B320935 B321109 21 B320064 B320234 B320943 B321117 22 0,37 B320072 0,55 B320242 1,5 B320951 2,2 B321125 23 B320080 B320250 B320978 B321133 31 B320099 B320269 B320986 B321141 32 0,55 B320102 B320277 2,2 B320994 3 B321168 33 B320110 B320285 B321001 B321176 41 B320129 B320293 B321028 B321184 42 B320137 1,1 B320307 3 B321036 4 B321192 43 B320145 B320315 B321044 B321206 51 B320153 B320323 B321052 B321214 52 B320161 1,1 B320331 4 B321060 5,5 B321222 53 B320188 B320358 B321079 B321230 2 speed motor 4/8 poles Series S ES S GV TGV 11 B320366 B320536 B321249 B321419 0,37 0,37 1,5 1 12 B320374 B320544 B321257 0,07 0,07 0,12 0,25 B321427 13 B320382 B320552 B321265 B321435 21 B320390 B320560 B321273 B321443 0,37 0,37 1,5 2,2 2 22 B320404 B320579 B321281 0,07 0,07 0,25 0,37 B321451 23 B320412 B320587 B321303 B321478 31 B320420 B320595 B321311 B321486 2,2 4 3 32 B320439 B320609 B321338 0,12 0,12 0,37 B321494 33 B320447 B320617 B321346 B321508 41 B320455 B320625 B321354 B321516 1,5 4 4 4 42 B320463 B320633 B321362 0,12 0,25 B321524 43 B320471 B320641 B321370 B321532 51 B320498 B320668 B321389 B321540 1,5 4 5,5 5 52 B320501 B320676 B321397 0,12 0,25 1,1 B321559 53 B320528 B320684 B321400 B321567 ES : Extra-Silent - S : Silent - GV : Large volume - TGV : Very large volume Main accessories 1 2 3 4 5 Series Filter cells Air intake boxes Diffusers G1 G4 F5 10 20 30 40 1 2 B347868 B347914 B347965 2904311 2904316 2904321 2904326 2904331 2838860 B347876 B347922 B347973 2904312 2904317 2904322 2904327 2904332 2838861 B347884 B347930 B347981 2904313 2904318 2904323 2904328 2904333 2838862 B347892 B347949 B348007 2904314 2904319 2904324 2904329 2904334 2838863 B347906 B347957 B348015 2904315 2904320 2904325 2904330 2904335 2838864 9

DIMENSIONS - SERIES 1 TO 5 Standard vertical fitting No. 300 Standard vertical fitting No. 500 Recommended drilling layout (inlet or outlet duct) R S T U Outlet flange V Inlet flange W Attachment : 4 M14 rods Cable hole (power supply cable) Filter EU 4 or EU 5 : extracted in direction shown by arrow Supply pipes : position when delivered according to drawing above. Possibility of changing on site. Alternatively, cable hole and grommet for electric units. Series A B C D E F G H I J K 1 660 470 1180 305 580 295 696 542 352 250 155 2 660 525 1180 305 580 295 696 542 407 250 182,5 3 750 610 1300 305 700 295 786 632 492 295 225 4 845 700 1440 305 840 295 881 727 582 342,5 270 5 970 830 1640 305 1040 295 1006 852 712 405 335 Approximate weights of units in kg Series 1 2 3 4 5 Units N 11 12 13 21 22 23 31 32 33 41 42 43 51 52 53 Standard model N 300 or 400 63 64 65 67 68 70 84 86 88 102 105 108 146 150 154 Accessories : Box N 10 20 30 40 10,5 9,5 24 25 11,5 10,5 27 28 15 14 35 38 18,5 16,5 45 48 24 22 64 68 Difuser N 1 18,5 23 30 36,5 47,5 10

DIMENSIONS Main accessories N 1 N 2 Diffuser N 10 N 20 Air intake box Grille frame N 30 N 40 Drilling : see below Air intake box Drilling : see below Recommended inlet duct drilling for air intake boxes 20, 30 and 40 series 1 series 2-3 - 4-5 Holes : 8 Holes : 8 Series A B C1 D E F G H I J K 1 660 470 360 129 226 596 122 2 660 525 400 169 281 596 122 1 31,5 2 64 3 750 610 480 249 366 686 122 1 74 2 109 4 845 700 520 289 456 781 122 1 119 2 156,5 5 970 830 600 369 536 906 147 2 34 3 94 11

EXAMPLES OF MOUNTING Vertical mounting with accessories N 310 N 311-312 N 331-332 N 320 N 321-322 N 341-342 Horizontal mounting with accessories N 501 N 520 N 530 N 540 Reminder : mounting 331 : standard unit N 300 - air intake box N 30 - Diffuser N 1 12

SECONDARY ACCESSORIES FOR INSTALLATION For vertical units Series rep. Description cote 1 2 3 4 5 d M0 anti-vibration sleeve (GM 3) e 140 f Connection frame (GM 1) e 60 n Intake grille (PM 2) e 7 p Rain protection frame, grille with automatic shutters (PM 4) e 125 (75 + 50) q Motorisable anti-freeze damper (PM 5) e 175 r M0 anti-vibration sleeve (PM 3) e 140 s Connection frame (PM 1) e 60 For horizontal units rep. Description cote Series 1 2 3 4 5 b Rain protection frame, grille with automatic shutters (GM 4) e 125 (75 + 50) c Motorisable antifreeze damper (GM 5) e 175 d M0 anti-vibration sleeve (GM 3) e 140 e Intake grille (GM 2) e 7 f Connection frame (GM 1) e 60 m Frame with vertical and horizontal orientable flaps (GM 9) e 121 n Intake grille (PM 2) e 7 p Rain protection frame, grille with automatic shutters (PM 4) e 125 (75 + 50) q Motorisable anti-freeze damper (PM 5) e 175 r M0 anti-vibration sleeve (PM 3) e 140 s Connection frame (PM 1) e 60 v Roofing e 90 w Canopy e 416 471 556 646 776 13

SECONDARY ACCESSORIES FOR MOUNTING Ref. Fonction Series 1 Series 2 Series 3 Series 4 Series 5 b c d e f m n p q r s v w x Rain protection frame and grille with automatic shutters (GM4) Motorisable anti-freeze damper (GM5) M0 anti-vibration sleeve (GM3) Intake grille (GM2) Connection frame (GM1) Frame with orientable vertical and horizontal flaps (GM9) Intake grille (PM2) Rain protection frame with automatic shutters (PM4) Motorisable anti-freeze damper (PM5) M0 anti-vibration sleeve (PM3) Connection frame (PM1) Roofing for external mounting (hot water) Hood with grille Polyethylene insulation with aluminium film code 2901938 2901939 2901943 2901944 2901945 code 2823065 2823066 2823067 2823068 2823069 code 2206296 2206297 2206298 2206299 2206300 code 2823218 2823219 2823220 2823221 2823222 code 2710663 2710664 2710665 2710666 2710667 code 2825475 2825476 2825477 2825478 2825479 code 2823213 2823214 2823215 2823216 2823217 code 2901936 2901937 2901940 2901941 2901942 code 2823060 2823061 2823062 2823063 2823064 code 2205666 2205667 2205668 2205669 2205670 code 2740026 2740027 2740028 2740029 2740030 code 2735198 2735198 2735199 2735200 2735201 code 2735094 2735095 2735096 2735097 2735098 code Consult us 14

ELECTRICAL ACCESSORIES Description Lockable proximity switch with remote position Complies with EC standards 1 speed - 3 poles - 20 A 0596142 not fitted 2 speeds - 6 poles - 20 A 0596147 Start / stop magnetothermal circuit breaker IP 55 sealed box magnetic trigger with alarm output Three phase 400 V from 0,12 to 2,2 B265527 Two speed control box DAHLANDER coupling 4 / 8 poles Motor 0,37 / 0,08 2734699 Motor / 0,12 2734701 Motor 1,5 / 0,25 2734703 Motor 2,2 / 0,37 2734669 Motor 4 / 2734671 Motor 5,5 / 1,1 2734675 Speed variator (frequency converter) Manual control or 0 / 10 V signal 4 pole motor max. output 0,18 à 0,55 Input / output voltage Mechanical protection IP 20 0817060 0817061 1,5 0817063 2,2 IP 20 thrre phase 400 V 0817064 3 à 4 0817066 4 IP 54 0817042 5,5 IP 54 0817043 Potentiometer for manual remote control 0816149 15