Air Measuring Products AMD AMS IAQ

Similar documents
Air Measuring Products. AMS Thermal Dispersion Pressure Differential

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Thermal Isolation. Break

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

HVAC Control & Balancing Dampers

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

HVAC Control & Balancing Dampers

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

VCD-23. Flange Options. Size Limitations

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

HCD-230 Industrial Control Damper

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

VCD-23 Low Leakage CONTROL DAMPER

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

VCD-23. Low Leakage CONTROL DAMPER

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model VCD-20 3V CONTROL DAMPER

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model FSD-331 Combination Fire Smoke Dampers

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Tube Axial Inline Fans

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

Air Quality Solutions

Laboratory Exhaust Systems

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

FOR USE IN SOLUTION AIR HANDLING UNITS

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Propeller Hooded Roof Fans

AD-1250 Airflow Measuring Station

Laboratory Exhaust Systems

SD-1250 and SD-1600 Series Smoke Dampers

Direct Gas-Fired Heating

Laboratory Exhaust Systems

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Introduction to Johnson Controls Dampers

SECTION CONTROL DAMPERS

Centrifugal Inline Fans

High Performance Axial Fans

AD-1251 Probe with Differential Pressure Transducer

LOW LEAKAGE VOLUME CONTROL DAMPER

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

RA-2000 Airflow Measuring System

Mixed Flow Inline Fan Model EQB

AIR CONDITIONING PRODUCTS COMPANY

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

RM-1200 Slim Round Control Damper

Qualified for installation in wood joist ceiling construction. CRD-1WT. Fire Dampers. Model

VOLU-probe. Pitot Airflow Traverse Probes. amca. Accurate airflow measurement for demanding applications. CERTIFIED RATInGS

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

RD-2000 Round Control Dampers

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Energy Recovery Laboratory Exhaust

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Centrifugal Inline Fans Models SQ and BSQ Direct and Belt Drive

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

High Performance Axial Fans

Model 8144NC Fresh Air Ventilator

ID-141x 12-Gauge Hat Channel Industrial Damper

Vane Axial Fans Models VAB and VAD. Belt and Direct Drive

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

GreenPark. Configurable Car Park Solutions

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Dual Duct Variable Air Volume Terminal (Model TDS)

Installation, Operation and Maintenance Manual

COMMERCIAL DUTY PLENUM FANS

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

Transcription:

Air Measuring Products AMD AMS IAQ January 1 2012

Air Measuring Products Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. By measuring the amount of outside air coming into a building, you can be assured a building is in compliance with all applicable indoor air quality codes including ASHRAE Standard 62 and California Title 24. Meeting these minimum requirements reduces indoor airborne viruses and bacteria which can lead to Sick Building Syndrome. Studies have shown that under ventilated buildings create an environment where people are less productive. Another advantage to monitoring outside air volumes coming into a building is to eliminate costly over ventilation. In addition to increased energy costs associated with heating and cooling of outside air, over ventilation causes an increase in humidity that can result in mold development. Where should an air measuring damper be used? Exhaust Air An air measuring control damper is used to measure and control outdoor air intake while a second air measuring control damper is used to measure and control the exhaust flow. The set point for the exhaust air damper would track the flow of the outdoor air damper (minus a differential if positive building pressure is desired.) Mixed Air An air measuring control damper is used to measure and control outdoor air intake while a second air measuring control damper is used to control the mixed air temperature. Normally an averaging sensor is required for mixed-air temperature control because the large temperature differences between return air and outdoor air cause stratification. The mixed air temperature is calculated from the flows and temperatures measured by each damper eliminating the measurement problem caused by stratification. Outside Air An air measuring control damper provides outdoor air control based on a demand signal. The demand signal could be determined by a set schedule or by occupancy sensors. Examples of demand signals are carbon dioxide (CO 2 ) concentration, a binary signal from a motion detector, or a manual switch. 2

IAQ-42 Greenheck s IAQ-42 is an air measuring control damper that utilizes patented Speciflow technology. The IAQ-42 will control air to: Prevent over ventilation Prevent under ventilation Provide energy savings during low occupancy periods The Speciflow technology built into the controller measures the pressure, position of the damper blades, and temperature of the air flowing through the damper. The IAQ-42 can help buildings meet the indoor/ outdoor air requirements of ASHRAE Standard 62 or California Title 24 by providing accurate monitoring and control of outside air. You can earn LEED-EB credits for air monitoring, increased ventilation, and ultra low leakage. The IAQ-42 is provided with a factory-supplied honeycomb air straightener (4 or 6 in. louver is optional), 24 Vac modulating actuator, air pressure pickups mounted on the damper blades, temperature sensors to allow the controller to correct airflow rate, and factory calibrated controller (optional). IAQ-42 with a 4 or 6 inch louver IAQ-42 with straightener What s the benefit of the IAQ-42 over the competition? The IAQ-42 has a number of advantages over the competition: By integrating the pressure pickups with the control damper, the pressure signal is increased at low velocities making the unit more accurate in non-uniform flow conditions. Locating the pickups on the blade amplifies the pressure signal which increases the accuracy of readings. The pickups can easily be repaired or replaced. The small size of the pickups add minimal pressure drop to the system. The controller with Speciflow technology automatically compensates for the effect of air temperature on air density. The controller with Speciflow technology can operate stand-alone or integrated with a DDC building control system. Benefits Greenheck IAQ-42 Ruskin IAQ50X Trane Traq Damper Low pressure drop Low velocity accuracy Temperature compensated Insensitive to condensation Integral controller Factory calibrated No additional ductwork required Easily maintainable Insensitive to non-uniform flow 3

AMS & AMD Series AMS The AMS is an accurate airflow measuring station and is furnished with a properly sized pressure transducer that outputs a signal proportional to cfm. A field supplied controller can use the transducer s signal along with the flow formula (provided) to regulate a modulating actuator to the target set point. The AMS is also available with a factory supplied LON controller that accepts a target flow set point as an input (either analog or digital) and outputs a 0-10 VDC signal that can be used to position a damper (sold separately) and a 0-10 VDC signal proportional to the airflow. AMD Series The AMD dampers were developed as a low cost alternative to the IAQ-42 damper. Field supplied controllers are very easy to program following labeling on the damper. Factory supplied controllers are also available A lower price solution was accomplished by: Providing lower cost, less complicated controllers Developing three different available blade styles (3V, Fabricated Airfoil, Aluminum Airfoil) Factory calibration is not required The AMD series comes standard with a modulating actuator and a properly sized pressure transducer that outputs a signal proportional to CFM. A field supplied controller can use the transducer s signal along with the flow formula (provided) to regulate a modulating actuator to the target set point. The AMD series is also available with a factory supplied LON controller that accepts a target flow set point as an input (either analog or digital) and outputs a 0-10 VDC signal proportional to the airflow. The AMD-23 is an accurate airflow measuring station combined with a low leakage control damper into one compact assembly that both measures and regulates airflow volumes to a target set point. Blade: 3V Blade Action: Parallel The AMD-33 is an accurate airflow measuring station and a low leakage control damper combined into one compact assembly that both measures and regulates airflow volumes to a target set point. Blade: Fabricated Airfoil Blade Action: Parallel 4

AMD Series The AMD-42 is an accurate airflow measuring station combined with a low leakage control damper in one compact assembly that both measures and regulates airflow volumes to a target set point. Blade: Extruded Aluminum Blade Action: Parallel The AMD-42V is an accurate airflow measuring station and a low leakage vertical blade control damper in one compact assembly that both measures and regulates airflow volumes to a target set point. Blade: Extruded Aluminum - Vertical Blade Blade Action: Parallel Quick Selection Chart AMS AMD-23 AMD-33 AMD-42 AMD-42V IAQ-42 Velocity ft/min (m/s) 2000 (10.2) 2000 (10.2) 2000 (10.2) 2000 (10.2) 2000 (10.2) 2000 (10.2) Temperature range F ( C) Factory calibration required No No No No No Yes Accuracy 5% 5% 5% 5% 5% 5% Measures airflow Regulates airflow volume Temperature compensated Factory supplied transducer Factory supplied controller Airflow straightener Blade Action Opposed Parallel Unit depth in. (mm) 8 (203) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) Maximum size 60 x 48 (1524 x 1219) 144 x 148 (3658 x 3759) 144 x 148 (3658 x 3759) 144 x 148 (3658 x 3759) 74 x 60 (1880 x 1524) Quick Build program 93 x 74 (2362 x 1880) 5

Damper Performance Testing Criteria Pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.201 kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. 5D Figure 5.3 5D Figure 5.2 D= 4 (W) (H) 3.14 6D Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. Figure 5.5 Greenheck Fan Corp. certifies that the models AMD-23, and AMD-33 shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance only. Pressure Drop Data AMD-23 Dimension inches 12x12 24x24 36x36 12x48 48x12 AMCA figure 5.2 5.3 5.5 5.2 5.3 5.5 5.2 5.3 5.5 5.2 5.3 5.5 5.2 5.3 5.5 Velocity (ft/min) Pressure Drop in. wg 500.05.04.07.03.03.05.03.03.05.04.03.06.03.03.05 1000.15.12.25.10.09.20.09.07.17.11.10.20.11.09.20 1500.31.24.54.21.17.41.18.14.36.23.20.43.22.19.42 2000.52.40.92.36.28.71.31.23.62.39.34.74.38.33.72 2500.80.60 1.41.54.43 1.10.46.35.96.58.51 1.13.57.50 1.11 3000 1.12.84 2.02.76.60 1.54.64.48 1.36.81.72 1.59.79.71 1.56 3500 1.51 1.12 2.73 1.01.80 2.09.86.64 1.84 1.10.97 2.14 1.06.96 2.12 4000 1.92 1.44 3.53 1.32 1.03 2.76 1.12.82 2.40 1.43 1.26 2.78 1.38 1.24 2.77 6

Damper Performance Testing Criteria AMD-33 Dimension inches 12x12 24x24 36x36 12x48 48x12 AMCA figure 5.2 5.3 5.5 5.2 5.3 5.5 5.2 5.3 5.5 5.2 5.3 5.5 5.2 5.3 5.5 Velocity (ft/min) Pressure Drop in. wg 500.04.04.07.03.03.05.03.03.05.03.03.06.04.03.05 1000.13.12.24.09.09.19.08.07.16.10.10.19.10.09.19 1500.27.24.50.19.17.38.16.14.34.21.20.41.21.19.41 2000.44.40.86.31.28.65.26.23.57.36.34.71.36.33.71 2500.66.60 1.33.47.43 1.00.39.35.88.54.51 1.09.55.50 1.10 3000.93.84 1.89.65.60 1.43.53.48 1.24.76.72 1.54.77.71 1.55 3500 1.25 1.12 2.57.88.80 1.9.71.64 1.67 1.02.97 2.08 1.03.96 2.10 4000 1.59 1.44 3.30 1.14 1.03 2.52.91.82 2.19 1.33 1.26 2.70 1.34 1.24 2.75 Leakage Damper leakage (with blades fully closed) varies based on the type of low leakage seals applied. The AMD-23 and AMD-33 are available with TPE blade seals and 304SS jamb seals or optional silicone blade seals. Test Information Air leakage is based on operation between 32 to 120 F (0 to 49 C). Tested for leakage in accordance with ANSI/AMCA Standard 500-D, Figure 5.5. Tested for air performance in accordance with ANSI/AMCA Standard 500-D, Figures 5.2, 5.3 and 5.5. Torque Data is based on a torque of 5.0 in.lb./ft² (0.56 N m) applied to close and seat the damper during the test. AMD-23 Leakage Class Maximum Damper Width 1 in. wg (0.25 kpa) 4 in. wg (1 kpa) 6 in. wg (1.5 kpa) 12 in. (305mm) 1A 1 1 48 in. (1219mm) 1A 1 1 AMD-33 Leakage Class Maximum Damper Width 1 in. wg (0.25 kpa) 4 in. wg (1 kpa) 6 in. wg (1.5 kpa) 8 in. wg (2 kpa) 10 in. wg (2.5 kpa) 12 in. (305mm) 1A 1 1 1 1 60 in. 1524mm) 1A 1 1 * * * Consult factory for pressure ratings above 6 in. wg (1.5 kpa). 7

Energy Saving Dampers from Greenheck The following models meet International Energy Conservation Code (IECC) requirements of damper leakage of 3 cfm/sq. ft @ 1 in. wg or less: AMD-23 AMD-33 AMD-42 AMD-42V ICD-44 ICD-45 IAQ-42 VCD-23 VCD-33 VCD-34 SEVCD-33 VCD-40 VCD-42 VCD-43 Enjoy Greenheck s extraordinary service, before, during and after the sale. Greenheck offers added value to our wide selection of top performing, energy-efficient products by providing several unique Greenheck service programs. Our Quick Delivery Program ensures shipment of our in-stock products within 24 hours of placing your order. Our Quick Build made-to-order products can be produced in 1-3-5-10- or 15-day production cycles, depending upon their complexity. Greenheck s free Computer Aided Product Selection program (CAPS), rated by many as the best in the industry, helps you conveniently and efficiently select the right products for the challenge at hand. Greenheck has been Green for a long time! Our energy-saving products and ongoing corporate commitment to sustainability can help you qualify for LEED credits. Our 3D service allows you to download at no charge lightweight, easy-to-use AutoDesk Revit 3D drawings for many of our ventilation products. Find out more about these special Greenheck services at greenheck.com Our Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the shipment date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs. As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Prepared to Support Green Building Efforts 8 P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com 00.DMP.1014 R1 1-2012 Copyright 2011 Greenheck Fan Corp.