SDBDe, STXDe, ered* Installation, Operation, and Maintenance Manual INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

ered Installation, Operation, and Maintenance Manual Direct Drive sizes 6-15 Nonoverloading B.I. Wheel

8-12 INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual

Model CWD Installation, Operation, and Maintenance Manual

Models eged/egsd. Installation, Operation, and Maintenance Manual. Direct Drive Sidewall Propeller Fans (Exhaust and Supply)

Model CFD Installation, Operation, and Maintenance Manual

Models STXB,STXBW, STXBRHUL, STXBHP Installation, Operation, and Maintenance Manual

Models TXB & TXB-W Installation, Operation, and Maintenance Manual

Model CFD Installation, Operation, and Maintenance Manual

Models LC, L2 & L3 Installation, Operation, and Maintenance Manual

Models BVS & CM - Level 1 Construction Installation, Operation, and Maintenance Manual

Model CFD Installation, Operation, and Maintenance Manual

Models TXB,TXB-W, TXB-RHUL Installation, Operation, and Maintenance Manual

Model SDB Installation, Operation, and Maintenance Manual

Models TXB,TXB-W, TXB-RHUL Installation, Operation, and Maintenance Manual

IM Centrifugal Power Roof & Wall Ventilators. Introduction. Shipment and Receiving. Handling. Storage. Issue Date: 4-97 Rev.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

HP190SL Series Slimline Radon Fans

FADE Series Wall Axial Fans

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

Axial Roof Ventilators & Tubeaxial Fans. General Installation, Operation and Maintenance Instructions For Aerovent Products

INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

BCRFS Belt Driven Centrifugal Filtered Supply Fans

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting

BCFS Belt Driven Centrifugal Filtered Supply Fans

MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN

MODEL VBO-HV & VBO UPBLAST PROPELLER ROOF FANS

Matala. VersiFlow Series. Instruction and Maintenance Manual

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

ECONOMIZER FAN. Receiving and Inspection

Air Curtain. Installation, Operating and Maintenance Instructions

WELDING FUME EXHAUSTERS & ARMS

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Positive Displacement Pump

48" and 52" Hyflo Fans Installation and Operators Instruction Manual

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Upblast Propeller Roof Fans

BULLETIN: VB PVC BLOWER-SCRUBBER VIRON INTERNATIONAL

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

HARTZELL. Cool Blast, Utility, and HartKool. Fans. Hartzell Fan, Inc., Piqua, Ohio

60 Series End-Mount Brake Instructions Standard Housing

SELF PRIMING CHEMICAL SERVICE PUMPS

INSTALLATION, OPERATION & MAINTENANCE MANUAL Hooded Propeller & Tubeaxial Roof Fans. Models: LHB, LHD, LHBF, LHDF, THB, THD, THBF, THDF

Effective June 1, 2013 This guide supersedes all previous versions

Model 7500 OPERATING INSTRUCTIONS MAINTENANCE INSTRUCTIONS. Terrco, Inc.

READ AND SAVE THESE INSTRUCTIONS

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

2SHE Series Direct-Drive Shutter Fans

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

DeZURIK 2 20" BOS BUTTERFLY VALVES

INSTALLATION, OPERATION & MAINTENANCE MANUAL. Centrifugal Square Inline Fans

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

AUTOMATIC SUBMERSIBLE UTILITY PUMP

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

Dispenser & Warmer RIC-1909 RIC-1909EXP

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

User s Manual D-Series Blowers and Exhausters

Powered Airette: Axial Flow Hooded Roof Ventilators: Direct & Belt Drive

SUNC3000 / Item #40885

HA/HAB Fiberglass Wall Mount Ventilators

Electric Actuator Installation, Operation & Maintenance Manual

GeyserMax-Flow Series

INW Panel Meter Reading an INW PT12 Sensor

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

Read this entire manual before operation begins.

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Centrifugal Square Inline Fans. General Installation, Operation and Maintenance Instructions For Aerovent Products

II DISTRIBUTION & SUBSTATION TYPE C

Centrifugal Square Inline Fans

MODEL 1100 TURBINE FLOW METER

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008

Axial Direct-Drive Downblast Ventilators. Operating Instructions & Parts Manual

EMISSION CONTROL WARRANTY STATEMENT

D-Series Blowers and Exhausters

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

SFP-250 and SFP-400. Installation Instructions. An Altra Industrial Motion Company P-231-WE

PRE-PLUMBED SEWAGE SYSTEM

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

1000-LB. MOTORCYCLE LIFT TABLE OWNER S MANUAL

ADI-125/750 ADI-125/1500 ADI-125/2500

SUBMERSIBLE MINI-PUMP

ASSEMBLY / OPERATION INSTRUCTIONS. Low Profile Motorcycle Dolly

CRD610 Automatic Fitting Inserter

User s Manual and Operating Instructions

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Transcription:

SDBDe, STXDe, STXDeRHUL Installation, Operation, and Maintenance Manual READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is to aid in the proper installation and operation of fans manufactured by JencoFan. These instructions are intended to supplement good general practices and are not intended to cover detailed instruction procedures, because of the wide variety and types of fans manufactured by JencoFan. 6393 Powers Avenue Jacksonville, FL 32217 P: 800.961.7370 F: 800.961.7379 SDBDe-IOM-v.2_1218

INTRODUCTION: DO NOT INSTALL, USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND UNDERSTOOD. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE USE. It is the responsibility of the purchaser to assure that the installation and maintenance of this equipment is handled by qualified personnel experienced in such work and equipment. Contact your local representative should you need further information. SHIPMENT AND RECEIVING: Prior to shipment, all fans have been thoroughly inspected and tested. All equipment shipped from JencoFan is skidded or crated to fully comply with trucking requirements. Inspect all shipments carefully for damage. THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER S BILL OF LADING AND FILE A CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY, IN THE CASE OF ANY DAMAGE. Keep a record of all equipment received, including inspection details and date of receipt, because of the possibility of partial shipments. If you receive damaged goods, contact your manufacturer s representative for repair or replacement service. HANDLING: Handle your equipment with caution. Some fans are provided with lifting lugs or holes for easy handling. Others must be handled using nylon straps that protect the fan s coating and housing. Spreader bars should be used when lifting large parts. Fans should be lifted by using straps around the fan housing only. DO NOT LIFT FANS BY THE MOTOR, BASE, WHEEL, OR FLANGES. Roof ventilators should be lifted by using straps around the fan housing or base only. Spreader bars should also be used to avoid damage. STORAGE: If fans are stored for any length of time, they should be stored in a clean, dry location to prevent rust and corrosion. Outdoor storage is not recommended. When outdoor storage is necessary, they should be protected from the elements as best as possible. Cover the fan inlet and outlet and keep motors dry and clean. For extended storage (more than 3 months), motor shafts and bearings should be rotated monthly. 2

INSTALLATION: Roof ventilators should always be mounted to a flat level, solid and rigid structure. Particular caution should be exercised when installing fans on metal buildings. Be sure wall or roofs are capable of supporting the fan(s). Walls/Roofs not supported correctly will cause vibration that could cause damage or injury. Fans mounted off ground level should be rigidly mounted to a special platform and be placed as near as possible to, or over, a solid wall or column. Use guy wires to help secure root units if excessively windy conditions prevail. 1. CAUTION! This fan contains rotating parts and requires special service. Appropriate safety precautions should be taken during installation, operation and maintenance. 2. WARNING! Do not install or operate this fan in an environment or atmosphere where combustible or flammable materials, gasses or fumes are present, unless it was specifically designed and manufactured for use in that environment. Explosion or fire can result. Explosive, corrosive, high temperature, etc. conditions may require special construction, inspection and maintenance. It is necessary to observe the fan manufacturer s recommendations and limitation concerning the type of material to be handled by the fan and its application in special conditions. 3. When ventilator is designed to be mounted on a curb, the curb should be securely installed prior to fan installation. 4. A damper, if used, should be securely mounted within the curb or wall in a manner that allows free and unobstructed operation. 5. CAUTION! All electrical work must be done in accordance with local and/or national electrical codes as applicable. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified electrician. 6. WARNING! This product must be grounded. 7. DANGER! Make sure power is turned off and locked in the OFF position at the service entrance before installing, wiring or servicing fan. 8. CAUTION! Before wiring the motor, check the supply voltage against the motor nameplate voltage. High or low voltage can damage the motor and void the motor warranty. 9. WARNING! Be sure to keep all wiring clear of rotating or moving parts. 3

10. WARNING! Before starting the fan, turn the wheel to assure it rotates freely. If needed, adjust the wheel and position as required to achieve necessary clearances. 11. WARNING! Check all setscrews and keys. Tighten as necessary prior to fan startup. 12. On roof units, anchor the fan securely to the curb. Anchoring through the vertical portion of the curb cap flange is recommended. Use a minimum of four lag bolts or other suitable fasteners. 13. Due to the general nature of its applications, the basic air mover is available with protective guards and/or other devices for required operating safety as with most installations of rotating machinery. Before operating the basic unit in any of its applications determine requirements for such guards and/or devices needed for protection against accidental contact with moving parts or against injury to nearby personnel or critical equipment due to accidental rupture of fast moving parts. START-UP: Lock out the power source. Tighten all bolts and setscrews securely. NOTE THAT ALL BOLTS AND SETSCREWS SHOULD BE TIGHTENED AFTER TWO DAYS OF INITIAL OPERATION. Clearance should be checked all around between wheel and the housing before starting up. The wheel should not strike the housing. No initial lubrication is required. Motors have been pre-lubricated by motor manufacturer. Arrows to show direction of rotation and airflow are attached to the fan housings. After the electrical connections are completed, apply just enough power to start the impeller as indicated by the directional arrows on the unit. If the impeller is turning the wrong direction, it will not deliver rated airflow and the motor connections must be altered to correct rotation. Lock out the power source before the installation of all accessories. Fan electrical power can now be applied and special attention should be given to determine if motor is working properly. At this time, with air system in full operation, with guards attached, it is well for the electrician to measure the operating amperage of the motor and compare with the nameplate rating to determine that the motor is operating under safe load conditions. The fan should not need balancing, as it was balanced at the factory to meet stringent vibration levels before shipment. However, there are several things that may cause vibration, such as rough handling in shipment and erection, weak foundations, and alignments. 4

WIRING NIDEC ECM PERFECT SPEED MOTOR DPST 115/208-230V 20 Amp Motor Rated Ground Green / Green with Yellow Stripe L1 115V/208-230 Black L2 Neutral White Black White Red Orange Nidec Motor Perfect Speed Controller 1 2 3 Red Black Red and Black (1) and (3) are used for connection to 0-10Vdc Control by others. 5

SET MOTOR SPEED WITH AND WITHOUT REMOTE POTENTIOMETER 0-10VDC Note: These instructions are not to be used with the EcoWatt control. Note: These instructions are used with a low voltage input control to the motor. Motor operation without remote potentiometer 1. The motor speed can be set by the small blue dial located on the module on the right side of the digital display with a small standard screwdriver. 2. Speed of the motor can be set, Low speed counter-clockwise, High speed clockwise. Motor operation with remote potentiometer 0-10Vdc 1. Set the small blue dial located on the module on right side of the digital display with a small standard screwdriver counter-clockwise this will deactivate the on-board control, the motor will now be controlled by the potentiometer. 2. Plug the 18 Ga. 2 wire 0-10Vdc connection harness part # 2501.62 in to the Perfect Speed module located on the bottom right side of the module next to the 4 wire connector, pin out is terminal 1 and 3. 3. Connect the other end of the 0-10Vdc wire harness to a potentiometer and now motor speed can be set remotely. MAINTENANCE: 1. Before performing any maintenance on the fan, be sure power is turned off and locked in the OFF position at the service entrance before servicing the fan. 2. Ventilators should be carefully checked at least once a year. For critical or rugged applications, a routine check every two or three months is suggested. 3. A periodic motor check should consist of spinning the motor shaft with the power off to be sure the motor turns freely and the bearings run smoothly. 4. During the first few months of operation, it is recommended that all setscrews be checked to assure they are tight. 5. The rotating wheel requires particular attention in most applications since materials in the air being handled can build up on the blades and cause destructive vibration; and may also corrode and/or erode the blade metal to weaken the structure. Regular inspection and corrective action at intervals determined by the severity of each application are essential to good service life. MOTORS: The fundamental principle of electrical maintenance is KEEP THE MOTOR CLEAN AND DRY. This requires periodic inspection of the motor. The frequency depends upon type of motor and the service. 6

We recommend periodic checks of voltage, frequency, and current of a motor while in operation. Such checks assure the correctness of frequency and voltage applied to the motor, and yield an indication of the fan load. Comparison of this data with previous data will give an indication of the fan performance. Any serious deviations should be investigated and corrected. Motors have sealed bearings with no grease fittings and are lubricated for life. 1. All motors carry a one (1) year warranty from date of shipment. For repairs within the warranty period, contact your representative for additional information as the motors are custom manufactured for these ventilators 2. A periodic motor check should consist of spinning the motor shaft with the power off to be sure the motor turns freely and bearings run smoothly. REPAIR PARTS: 1. Fan Wheel Repair of individual blades is not recommended. Contact factory with blade size, number of blades, bore size, motor HP, air flow direction, rotation, and any order/tag information that is available for replacement. 2. Misc. Parts Not available from local trade channels should be returned for repair or replacement. Be sure to obtain return tags or authorization before shipment. 3. Electric Motors Repair or replacement of motors is normally performed by a repair station authorized by the manufacturer. Contact your representative or the factory for locations nearest to you. DO NOT ship motor to the factory without specific authorization. 7

FAN TROUBLE-SHOOTING CHART PROBLEM Excessive Vibration Excessive Horsepower Too Little Air Too Much Air POSSIBLE CAUSES Wheel loose on shaft Out of balance wheel Excessive buildup of dirt/dust on wheel Bent shaft Weak mounting base for fan Fan mounting bolts loose Loose or worn bearings Structures not cross braced (wall fans) Curb not flat and level Static pressure higher than design Wheel rotating in wrong direction Restricted fan inlet or outlet Filters are dirty or clogged Wheel or propeller rotating in the wrong direction System is more restrictive (more static pressure) than expected Fan speed lower than design Inlet or Outlet screens clogged Filters not in place Fan speed higher than design System is less restrictive (less static pressure) than expected Fan Does Not Operate PROBLEM Excessive Noise Wrong voltage Electricity turned off or note wired properly Blown fuses Overload protector has broken circuit POSSIBLE CAUSES Wheel loose Bearing misalignment Accumulation of material on wheel Worn or corroded wheel Wheel out of balance Wheel hitting housing Bent shaft Defective or bad bearings Loose or worn bearings Loose fan mounting bolts Rattle of components in high velocity airstream Electrical noise Noise from high velocity air system Vibrating parts not isolated from building Vibrating duct work 8

Replacement Parts Model SDBDe 06C-16 2 3 1 Model SDBDe Motor HP Wheel 1 Motor Cover Cap 2 Bird Screen 3 06C 1/10 400398 1/3 400388 100460 100445 6 1/10 400398 1/3 400388 100460 100445 7 1/10 400399 1/3 400388 100460 400215 1/25-1/10 400399 8 1/4 EXP 400397 100460 400215 1/4-1/3 400400 10 1/4-1/3 400401 100454 400216 12 1/4-3/4 400402 400116-1 400206-1 14 1/4-1 400403 SDBDe14 1 400389 400116-1 400206-1 15 1/2, 1-1/2 400395 3/4 400403 400117-1 400207-1 SDBDe15 1/2-1 400390 16 1/2-1-1/2 400393 SDBDe16 1 400391 400117-1 400207-1 SDBDe _Parts_1218 9

Replacement Parts Model STXDe, STXDeRHUL 06C-16 2 3 1 Model STXDe, STXDeRHUL Motor HP Note: For RHUL Base Drop the A suffix Wheel 1 Motor Cover Cap 2 Wind Band 3 06C 1/10 400399 1/3 400400 400125 400194 6 1/10 400399 1/3 400400 400125 400194 7 1/10 400399 1/3 400400 400125 400194 1/25-1/10 400399 8 1/4 EXP 400397 400125 400194 1/4-1/3 400400 10 1/4-1/3 400401 400125 400194 12 1/4-3/4 400402 400126 400195 14 1/4-1 400403 STXDe14 1 400389 400126 400195 15 1/2, 1-1/2 400395 1-1/2 400403 STXDe15 1/2-1 400390 16 1/2 1-1/2 400393 STXDe16 1 400391 400127 400196 400127 400196 STXDe, STXDeRHUL_ Parts_1218 10

WARRANTY: Manufacturer warrants this equipment to be free from defects in material and workmanship for five (5) years from date of shipment. Any units or parts which prove to be defective and are reported during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Deterioration or wear by heat, abrasive action, chemicals, improper installation or operation or lack of normal maintenance shall not constitute defects, and are not covered by warranty. The motor is warranted by the motor manufacturer for one year. If the motor becomes defective in the warranty period, contact your representative for replacement motor information. If this is not done, the manufacturer will not warrant the motor. Manufacturer will not be responsible for any installation, removal or re-installation costs or any consequential damage resulting in failure to meet conditions of any warranty. LIMITATION OF WARRANTY AND LIABILITY This warranty does not apply to any such product or parts which have failed as a result of faulty installation or abuse, or incorrect electrical connections or alterations, made by others, or use under abnormal operating conditions or misapplication of the products and parts. Manufacturer will not approve for payment any repairs made outside the factory without prior written consent of its Jacksonville, Florida office. The foregoing shall constitute our sole and exclusive warranty and our sole and exclusive liability and is in lieu of all other warranties, whether written, oral, implied or statutory. There are no warranties which extend beyond the description of the page hereof. Seller does not warrant that said goods and articles are of merchantable quality or that they are fit for any particular purpose. The liability of seller on any claim of any kind, including negligence, for any loss or damage arising out of or connected with, or resulting from the sale and purchase of the products and parts covered by this proposal, acknowledgement, order or from the performance or breach of any contract pertaining to such sale or purchase, or from the design, manufacture, sale, delivery, resale, installation, technical direction of installation, inspection, repair, operation or use of any products or parts covered by this proposal, acknowledgement, order or furnished by seller shall, in no case exceed the price allocable to the products or parts thereof which give rise to the claim and shall terminate one (1) year after the shipment of said products and parts. In no event, whether as a result of breach of contract, or warranty or alleged negligence, defects, incorrect advice or other causes, shall seller be liable for special or consequential damages, including, but not limited to, loss of profits or revenue, loss of use of the equipment or any associated equipment, cost of capital, cost of substitute equipment, facilities or services, down time costs, or claims of customers of the purchaser for such damages. Manufacturer neither assumes nor authorizes any persons to assume for it any other liability in connection with the sale of its fan products and parts. Some states do not allow the exclusion or limitation of incidental or consequential damages, so all of the above limitations or exclusions may not apply to you. 11

SAFETY ACCESSORIES WARNING: The responsibility for providing safety accessories for equipment supplied by JencoFan is that of the installer and user of this equipment. JencoFan sells its equipment with and without safety accessories, and accordingly it can supply such safety accessories upon receipt of order. The user, in making its determination as to the appropriate safety accessories to be installed and any warning notices, should consider (1) the location of the installation, (2) the accessibility of employees and other persons to this equipment, (3) any adjacent equipment, (4) applicable building codes, and (5) requirements of the Federal Occupational Safety and Health Act. Users and installers of this equipment should read RECOMMENDED SAFETY PRACTICES FOR AIR MOVING DEVICES which is published by Air Movement and Control Association, 30 West University Drive, Arlington Heights, Illinois 60004. 12

13