Test Report No.: SDHL FT Date: Jun.15, 2017 Page 1 of 5

Similar documents
Test Report No.: AJHL FT Date: JUN.02, 2016 Page 1 of 5

Test Report No.: SDHL FT Date: May 15, 2017 Page 1 of 15

APPLICANT: EMECO DATE: Mar 10, ELM AVE HANOVER, PA, USA

Test Report No.: AJD Date: NOV.05, 2013 Page: 1 of 5

Test Report. Report No: BSTDG YRR-4 Date: Mar. 27, 2015 Page 1 of 7. :No.27, Shunsi Road, Ronggui Town, Shunde District, Guangdong Province

Test Report For: EMECO INDUSTRIES INC Bar Stool

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report. No. SHAHG Date: 07 Nov Page 1 of 9.

Test Report. No. SHAHG Date: 11 Nov Page 1 of 7.

OFS Brands Test Facility Report No: OFSB Date: April 2, 2015 Page: 1 of 29. Test Report For: ANSI/BIFMA X Storage Units.

Contact person Date Reference Page Ulf Lemke F027196A 1 (4) Wood Technology

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

FEDERAL STANDARD PERFORMANCE TEST METHOD FOR INTENSIVE USE CHAIRS

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report. No. NGBHG Date: 28 Jun Page 1 of 6.

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

FOSHAN SHUNDE HEXIN ELECTRON CO.,LTD

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

General-Purpose Office Chairs - Tests

Test Report No.: SHHG BC Date: JAN.31,2013 Page: 1 of 12

Contact person Date Reference Page Michael Lindblad F025884B 1 (1) Sustainable Built Environment

TEST REPORT N

THE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-112R Extension number: 00

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. UL 2528 Cathy Ln Jasper, IN Brian Truelove Phone: MECHANICAL

Contact person Date Reference Page Michael Lindblad F025884A 1 (1) Sustainable Built Environment

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10

THE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-23R Extension number: 00

TEST REPORT FOR: Product Design Group Fuze T50 Manual Wheelchair (204 kg / 450 lb)

Test Report. TIANJIN TOYO INK CO.,LTD.. 12XINGHUA2#ROAD XIQING ECONOMIC DEVELOPMENT AREA,TIANJIN , CHINA.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. UL 3480 Windquest Drive Holland, MI Dan Kolean Phone: MECHANICAL

Seth Setzer Submit Samples to: Phone: Ext.

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

Instruction Manual for LED Underwater Light HT008C-P-T

Test Report No: EEC18/01 dated August 02, 2018

: Metta Company : FLTSSP _07. : Swiss Approval Furniture Laboratory. : Elefsis, Attica Greece

THE UNITED KINGDOM TYPE APPROVAL AUTHORITY

Test Report. No. SHAHG Date: 12 Dec Page 1 of 7.

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Instruction Manual for Resin Filled LED Underwater Light

Test Report. No. SHAHG A01 Date: 10 May Page 1 of 6.

TEST REPORT FOR: Product Design Group Inc. Elevation Manual Wheelchair 115 kg, 253 lb

NovitaTech Engineering

Test Report No.: SHHG MD Date: FEB. 26, 2016 Page: 1 of 17

Internrapport

Contact person Date Reference Page Ulf Lemke F015337C 1 (4) Wood Technology

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N

STADIUM. Seating Products

Contact person Date Reference Page Hans Eriksson F000838G 1 (4) Wood Technology

page 1/5 EN 16139:2013, test severity level 1 Manager Kinnarps Test- & verification Center

Contact person Date Reference Page Michael Lindblad F000833F 1 (1) Sustainable Built Environment

Cape Town based suppliers & manufactures of portable & mobile massage tables, beds & accessories to the beauty industry in South Africa.

David Fagan, Mobility Manager Paragon Mobility Pty Ltd 3/10 Tapnor Crescent, Brendale, Queensland th December, 2011.

Full extension concealed slide with soft closing and self-closing

page 1/6 EN 16139:2013, test severity level 1 The sample submitted for test fulfils the requirements in above mentioned standards.

APPLICATION FOR CONSTRUCTION PRODUCTS DIRECTIVE. On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder.

Cape Town based suppliers & manufactures of portable & mobile massage tables, beds & accessories to the beauty industry in South Africa.

Verplas Self-Seal Coupling Leakage Test. Prepared for : Verplas Limited. 25 February Test report number Page 1 of 11

Seating Excellence at Work

TEST REPORT. Version:V1.0 Page 1 of 9. Client company : Berdis Lighting Co., LTD.

Contact person Date Reference Page Michael Lindblad F013838C 1 (1) Sustainable Built Environment

Test Report No. GZTXO TX Date: Jun 30, 2008 Page 1 of 6

Sealed Lead Acid Battery STANDBY APPLICATIONS. Premium Brand of Flying Power Group. Certified by

Test Report. No. SHAEC Date: 15 Jul Page 1 of 5.

SYNCHRON. Seating Products

Applied Fluid Mechanics

WAU. Seating Products

Test Report No.: SDHL FT Date: Aug.16, 2017 Page 1 of 47

Report of Test LLIA

VIDA. Goole. Tel. +44 (0) EC1M 4NQ. Tel. +44 (0)

SILVER SURF. Sitool. Seating Products

Applicant: GUANGDONG XIN YU TECHNOLOGY INDUSTRIAL Date: Feb 24, 2017 CO.,LTD. LAI MEI INDUSTRIAL ZONE, CHENGHAI DISTRICT, SHAN TOU, GUANGDONG, CHINA

10-Feb-14. VCA job number: CSP Date: 10 February Dear Sirs,

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82

KSQ9001:2009/ISO9001:2008 A-RYUNG. AR2013-ATP-EK1

Test Report. No. SHAEC Date: 23 Apr Page 1 of 5.

Sayl Chairs. Published September Work Chair. Side Chair. Stool Herman Miller, Inc., Zeeland, Michigan

Sola. 290 range. Digital-brochure-290-Sola-02-SR

TEST REPORT. Automobile Parts Test Center (Guangzhou) Car Care Products (Oil System Cleaner, Oil System Care, Fuel System Cleaner) Commissioned Test

Type: Office work chair Lab.no.: Depth: 650 mm Width: 710 mm Height: 1345 mm Weight: 18,8 kg. EN :2009 and EN :2009.

SINGLE VOLTAGE EXTERNAL POWER SUPPLY TEST REPORT

QB/T Translated English of Chinese Standard: QB/T

Type: Office work chair Lab.no.: A. EN :2009 Office furniture - Office work chair - Part 2: Safety requirements.

Contact person Date Reference Page Hans Eriksson F000838D 1 (3) Wood Technology

- Name & Address Of Buyer: AL-LAMAA PALACE TRAD EST. Add: exit-18 new sulai industrial area riyadh-saudi arabia

Applicant: GUANGDONG XIN YU TECHNOLOGY INDUSTRIAL Date: Jul 09, 2016 CO.,LTD. LAI MEI INDUSTRIAL ZONE, CHENGHAI DISTRICT, SHAN TOU, GUANGDONG, CHINA

V1000 / V2000 / V5000 Intelligent Efficient Reliable Affordable

T~$t P~Cijpt1oll ', je~t# ' ~n~:2{211rtadje.sampje. PREPARED FOR: Comfor Tek Seating Street North Lethbridge, AB

page 1/5 EN 16139:2013, test severity level 1

Certificate of testing

Technical Report No D Dated

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N

14 SEER Condensing Units

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax

Caper Chairs 1 Technical Specifications. Caper Chairs

MANUFACTURER : FLASHBAY ELECTRONICS BLGD B&C XI FENG CHENG IND ZONE, NO. 2 FUYUAN ROAD HE PING, VILLAGE, FUYONG TOWN, SHENZHEN

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N

APPLICATION FOR SAFETY OF TOYS DIRECTIVE On Behalf of. Nanjing Feeling Rubber & Plastic Produces Co., Ltd. EPDM Rubber Granule

Transcription:

Test Report No.: SDHL1705010441FT Date: Jun.15, 2017 Page 1 of 5 SHENGZHAO FURNITURE FACTORY LIANGYONG INDUSTRIAL ZONE, ZHENNAN JIUJIANG TOWN, FOSHAN CITY, GUANGDONG PROVINCE, CHINA The following sample(s) was / were submitted and identified on behalf of the client as: Sample Description Manufacturer Country of Origin : SZ-B819 OFFICE CHAIR : SHENGZHAO FURNITURE FACTORY : CHINA Sample Receiving Date : May 26, 2017 Test Performing Date : May 26, 2017 to Jun.15, 2017 Test(s) Requested Test Result Summary Backrest Strength Test - Static - Type l and II, Backrest Strength Test - Static - Type lll and Backrest Durability Test - Cyclic - Type l of ANSI/BIFMA X5.1-2017 (Type I, III) Summary: 1. For further details, please refer to the following page(s). Result(s) Signed for and on behalf of Shunde Branch SGS-CSTC Co., Ltd. Caming Fan Approved signatory

Test Report No.: SDHL1705010441FT Date: Jun.15, 2017 Page 2 of 5 TESTS AND RESULTS Test Conducted: Backrest Strength Test - Static - Type l and II, Backrest Strength Test - Static - Type lll and Backrest Durability Test - Cyclic - Type l of ANSI/BIFMA X5.1-2017 General-Purpose Office Chairs Tests. No. of Sample: 2 piece(s) (Sample 1, 2). For more sample information and pictures, please refer to the following page. Chair Type: Type I, III. Test and Requirements 5 Backrest Strength Test - Static - Type l and II 5.4.1 Functional Load There shall be no loss of serviceability to the chair when 667 N (150 lbf.) is applied to the backrest at the specified position for one (1) minute. With the backrest at its back stop position, apply a force that is initially 70 degrees ± 10 degrees to the plane of the backrest. The force is not intended to be maintained at 70 degrees ± 10 degrees throughout the loading of the backrest. 5.4.2 Proof Load There shall be no sudden and major change in the structural integrity of the chair, loss of serviceability is acceptable, when 1001 N (225 lbf.) is applied to the backrest at the specified position for one (1) minute. With the backrest at its back stop position, apply a force that is initially 70 degrees ± 10 degrees to the plane of the backrest. The force is not intended to be maintained at 70 degrees ± 10 degrees throughout the loading of the backrest. 6 Backrest Strength Test - Static - Type lll 6.4.1 Functional Load There shall be no loss of serviceability to the chair when 667 N (150 lbf.) is applied to the backrest at the specified position for one (1) minute. With the backrest at its back stop position, apply a force that is initially 90 degrees ± 10 degrees to the plane of the backrest. The force is not intended to be maintained at 90 degrees ± 10 degrees throughout the loading of the backrest. 6.4.2 Proof Load There shall be no sudden and major change in the structural integrity of the chair, loss of serviceability is acceptable, when 1001 N (225 lbf.) is applied to the backrest at the specified position for one (1) minute. With the backrest at its back stop position, apply a force that is initially 90 degrees ± 10 degrees to the plane of the backrest. The force is not intended to be maintained at 90 degrees ± 10 degrees throughout the loading of the backrest. Test Results

Test Report No.: SDHL1705010441FT Date: Jun.15, 2017 Page 3 of 5 Test and Requirements 14 Backrest Durability Test - Cyclic - Type l A weight of 109 kg (240 lb.) shall be secured in the center of the seat. Apply a 445 N (100 lbf.) total force to the backrest at the specified position at a rate between 10 and 30 cycles per minute. For chairs with backrest widths less than or equal to 406 mm (16 in.) at the height of the loading point, apply the load to the backrest for 120,000 cycles. For chairs with backrest widths greater than 406 mm (16 in.) at the height of the loading point, apply the load to the backrest for 80,000 cycles + 20,000 cycles at the position 102 mm (4 in.) to the right of the vertical centerline + 20,000 cycles at the position 102 mm (4 in.) to the left of the vertical centerline.. There shall be no loss of serviceability. Note: With the backrest at its back stop position, apply a force that is initially 90 degrees ± 10 degrees to the plane of the backrest. The force is not intended to be maintained at 90 degrees ± 10 degrees throughout the loading of the backrest. Test Results Remark: 1. For the sample information and pictures, please refer to the following page.

Test Report No.: SDHL1705010441FT Date: Jun.15, 2017 Page 4 of 5 Weight: Sample #1: 15.85 kg Sample #2: 14.70 kg SAMPLE INFORMATION AND PICTURES Overall Dimensions: Sample #1: 760 mm L x 725 mm W x 1180~1250 mm H Sample #2: 750 mm L x 713 mm W x 960~1028 mm H Other Dimensions: Base radius, 358 mm; base weight, 2.0 kg. Sample as Received Sample #1 - View 1 Sample #1 - View 2 Sample #1 - View 3 Sample #1 - View 4

Test Report No.: SDHL1705010441FT Date: Jun.15, 2017 Page 5 of 5 Sample #2 - View 5 Sample #2 - View 6 Sample #2 - View 7 Sample #2 - View 8 Sample #1&2 - View 9 ***End of Report***