Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Similar documents
Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-331 Combination Fire Smoke Dampers

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

VCD-23. Flange Options. Size Limitations

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

VCD-23 Low Leakage CONTROL DAMPER

VCD-23. Low Leakage CONTROL DAMPER

Model VCD-20 3V CONTROL DAMPER

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Model VCD-43 Extruded Airfoil Blade Control Damper

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Thermal Isolation. Break

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

HCD-230 Industrial Control Damper

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Fusible Link (replaceable) Horizontal Mount

Fusible Link (replaceable) Horizontal Mount

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

Motorized Fire Dampers

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

HVAC Control & Balancing Dampers

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

CFSD Series. Product Description

Air Measuring Products AMD AMS IAQ

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

HVAC Control & Balancing Dampers

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

Fire, Smoke, and Combination Fire Smoke Dampers

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Installation, Operation and Maintenance Manual

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

SMOKE DAMPER - CLASS F MODEL BMSD

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Installation, Operation and Maintenance Manual

MULTI-BLADE FIRE DAMPERS

SD-1250 and SD-1600 Series Smoke Dampers

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

BD-1600 Balancing/Zone Control Damper

MULTI-BLADE FIRE DAMPERS

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

ARROW INDUSTRIAL PRODUCTS

ID-141x 12-Gauge Hat Channel Industrial Damper

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Part # Installation,Operation and Maintenance Instructions

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Fire Dampers Catalogue

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

AIR DUCT ACCESSORIES

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Introduction to Johnson Controls Dampers

Life Safety Dampers - International. Fire Combination Fire Smoke Smoke Ceiling Radiation

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

Blast Protection Damper

Series HCD Airfoil Control Damper

LLOYD INDUSTRIES INC.

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

MODEL 151B FIRE DAMPER

Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers. UL Classified High Free Area Minimal Pressure Drop

Transcription:

Application and Design Model is a combination fire smoke damper that is UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model s operational ratings of 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) far exceed the air flows and pressure differences normally encountered when installed above grilles or diffusers in corridor ceilings - providing an extra measure of safety. is rated for airflow and leakage in either direction and can be used in vertical or horizontal installations. Ratings UL 555 Fire Resistance Rating Fire Rating: 1 hour Dynamic Closure Rating: Actual limits are size dependent Maximum Velocity: 2000 fpm (10.2m/s) Maximum Pressure: 6 in. wg (1.5 kpa) UL 555S Leakage Rating Leakage Class: I Operational Rating: Limits are actuator dependent Maximum Velocity: 2000 fpm (10.2 m/s) Maximum Pressure: 6 in. wg (1.5 kpa) Maximum Temperature: 350 F (177 C) - depending upon the actuator Construction Standard Optional Frame Material Galvanized steel - Frame Material 16 ga. (1.5mm) - Thickness Frame Type 5 in. x 1in. - (127mm x 25mm) hat channel Blade Material Galvanized steel - Blade Material 16 ga. (1.5mm) - Thickness Blade Type 3V - Linkage Plated steel out of 304SS airstream, concealed in jamb Axle Bearings Bronze 304SS Axle Material Plated steel 304SS Blade Seals Silicone - Jamb Seals 304SS - Closure Device RRL RRL/OCI, TOR, PRV, Fusible LInk Closure Temperature 165 F (74 C) 212 F (100 C), 250 F (121 C), 350 F (177 C) Minimum Size Maximum Size W x H Configuration Configuration Configuration Single Section 1 2 3 Inches 12 x 12 8 x 6 8 x 6 24 x 24 mm 305 x 305 203 x 152 203 x 152 610 x 610 Model Corridor FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I Model meets the requirements for corridor ceiling dampers, smoke dampers and combination fire/smoke dampers established by: National Fire Protection Association NFPA Standards 80, 90A, 92A, 92B, 101 & 105 IBC International Building Codes New York City (MEA Listing #260-91-M) CSFM California State Fire Marshal Listing #: 3230-0981:105, 3225-0981:106 UL CLASSIFIED (see complete marking on product) UL CLASSIFIED to Canadian safety standards (see complete marking on product) Standard 555 & 555S (Listing #R13317) H* model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only. * W & H dimensions furnished approximately 1 /4 in. (6mm) undersize. (Add sleeve thickness for overall sleeved damper dimension) Right hand drive is shown. Left hand drive is available upon request. Features: Frames are constructed with reinforced corners. Low profile head and sill are used on sizes less than 17 in. (432mm) high. Blades are reinforced with 3 longitudinal structurally designed vee's. Options: Actuators (120V, 24V, 230V, pneumatic) POC retaining angles Momentary or toggle test switches Sealed transition and sleeve Flanges Grille Tabs Greenheck Test Switches (GTS-1, -2, -3, -4) Transitions (R, C, O) Clean Wrap W* Installation instructions available at www.greenheck.com

pressure drop Data cfsd-211 This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.201 kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. 6D D 4 (W) (H) 3.14

AMCA 5.2 Figure 5.2 * * This size is based on multi-section unit. 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x 48 in. (305mm x 1219mm) 500 0.04 500 0.02 500 0.01 500 0.01 1000 0.14 1000 0.07 1000 0.04 1000 0.06 1500 0.31 1500 0.16 1500 0.09 1500 0.13 2000 0.55 2000 0.29 2000 0.16 2000 0.23 2500 0.86 2500 0.45 2500 0.25 2500 0.36 3000 1.24 3000 0.65 3000 0.36 3000 0.52 3500 1.69 3500 0.89 3500 0.49 3500 0.70 4000 2.20 4000 1.16 4000 0.64 4000 0.92 48 in. x 12 in. (1219mm x 305mm) 500 0.03 1000 0.10 1500 0.23 2000 0.41 2500 0.63 3000 0.91 3500 1.24 4000 1.62 model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only.

AMCA 5.3 6D * This size is based on multi-section unit. 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x 48 in. (305mm x 1219mm) 500 0.02 500 0.01 500 0.01 500 0.01 1000 0.09 1000 0.04 1000 0.03 1000 0.04 1500 0.20 1500 0.09 1500 0.06 1500 0.10 2000 0.36 2000 0.16 2000 0.11 2000 0.17 2500 0.56 2500 0.25 2500 0.17 2500 0.27 3000 0.81 3000 0.35 3000 0.24 3000 0.39 3500 1.10 3500 0.48 3500 0.33 3500 0.53 4000 1.44 4000 0.63 4000 0.42 4000 0.70 48 in. x 12 in. (1219mm x 305mm) 500 0.02 1000 0.07 1500 0.16 2000 0.29 2500 0.45 3000 0.64 3500 0.88 4000 1.14 model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only.

AMCA 5.5 * This size is based on multi-section unit. 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x 48 in. (305mm x 1219mm) 500 0.06 500 0.03 500 0.03 500 0.03 1000 0.22 1000 0.14 1000 0.12 1000 0.13 1500 0.50 1500 0.31 1500 0.26 1500 0.30 2000 0.89 2000 0.54 2000 0.46 2000 0.53 2500 1.39 2500 0.85 2500 0.73 2500 0.83 3000 2.00 3000 1.22 3000 1.05 3000 1.19 3500 2.72 3500 1.66 3500 1.42 3500 1.62 4000 3.55 4000 2.17 4000 1.86 4000 2.11 48 in. x 12 in. (1219mm x 305mm) 500 0.04 1000 0.17 1500 0.38 2000 0.67 2500 1.04 3000 1.50 3500 2.05 4000 2.67 model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only.

Configurations Space Envelopes is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings below illustrate these different configurations and their associated dimensions. Configuration #1 Fire Rated Is The Finished : Actuator (Internal Only) Accessible Through The Grille H Actuator Space Envelopes Honeywell ML-4XXX Series MS4209 Series in. (mm) Fire Rated X Grille (by others) 5 A Sleeve Length X Dimension 8 1/8 (206) Minimum Width 12 (305) Minimum Height 12 (305) Sleeve Length = Depth of Grille (or Register) + X (Actuator: see table above) + 5 in. [127mm] (Damper Width) + 11/4 in. [31.8mm] (for duct connection) (round up to nearest length: 16 in., 18 in., or 21 in. [406mm, 457mm, or 533mm] Sleeve Gauge = 16 Ga. (1.5mm) or 20 Ga. (1mm) Configuration #2 Fire Rated Is The Finished : Actuator (Internal or External) Accessible Above Finished H A Configuration #2 is for applications where the fire rated ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators can be mounted internally or externally. Clearance must be maintained between damper and grille for proper operation. 5 Sleeve Length All dimensions shown are in inches (mm). Fire Rated Grille (by others) 4 3/4 Min. Minimum Size Internal : 12 in. x 12 in. (305mm x 305mm) When OCI, RRL, or TOR, H dimension less than 10 in. (254mm) 'A' Dimension Standard 12 (305) Minimum Sleeve Length 21 (533) All other dampers 7 3/16 (182) 16 (406) Configuration #3 H Fire Rated Is Above The Finished : Actuator (Internal or External) Accessible Through Finished Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted internally or externally. Fire Rated Finished Below A Sleeve Length Minimum Size Internal : 12 in. x 12 in. (305mm x 305mm) When OCI, RRL, or TOR, H dimension less than 10 in. (254mm) All dimensions shown are in inches (mm). 'A' Dimension Standard 12 (305) Minimum Sleeve Length 21 (533) All other dampers 7 3/16 (182) 16 (406)

Specifications Corridor Fire Smoke Dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Dampers shall meet the requirements of the latest edition of NFPA 80, 90A, 92A, 92B, 101 & 105. Dampers shall be tested, rated and labeled in accordance with the latest edition of UL Standards 555 and 555S. Dampers shall be classified by UL under the Corridor Damper listing with a UL 555 fire rating of 1 hour. Each damper shall be equipped with a heat responsive device which has been tested and approved for use with the damper assembly in accordance with UL 555. The heat responsive device shall have a temperature rating of (specifier select one of the following) 165 F (74 C), 212 F (100 C), 250 F (121 C), or 350 F (177 C). Dampers shall be UL labeled for use in dynamic systems. The damper shall have a dynamic closure airflow rating equal to or greater than the airflow at the damper s installed location and a dynamic closure pressure rating of 6 in. wg (1.5 kpa). Dampers shall have a UL 555S Leakage rating of Class I and a temperature rating of 250 F (121 C) minimum. Dampers shall have a UL 555S operational airflow rating equal to or greater than the airflow at its installed location and an operational pressure rating of 6 in. wg (1.5 kpa). Damper actuators must be factory mounted and qualified for use with the damper in accordance with UL 555S. Damper actuators shall be (specifier select one of the following) electric type for 120 (24 or 230) volt operation. Manufacturers submittal data shall indicate actuator space requirements around the damper. All UL 555 and 555S Dynamic Closure Ratings, Operational Ratings and Leakage Ratings shall be qualified for airflow and pressure in either direction through the damper. UL ratings shall allow for mounting damper vertically (with blades running horizontal) or horizontally. The Damper Manufacturers submittal data shall certify all air performance pressure drop data is licensed in accordance with the AMCA Certified Ratings Program for Test Figures 5.2, 5.3 and 5.5. Damper air performance data shall be developed in accordance with the latest edition of AMCA Standard 500-D. Dampers shall be labeled with the AMCA Air Performance Seal. Dampers shall be listed by the California State Fire Marshal. Dampers shall be listed by the New York City Department of Buildings Material and Equipment Acceptance (MEA). Damper blades shall be 16 ga. (1.5mm) galvanized steel 3V type with three longitudinal grooves for reinforcement. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow and operation in either direction through the damper (blades that are non-symmetrical relative to their axle pivot point or utilize blade stops larger than ½ in. (13mm) are unacceptable). Damper frames shall be galvanized steel formed into a structural hat channel shape with reinforced corners. Bearings shall be sintered bronze sleeve type rotating in extruded holes in the damper frame. Blade edge seals shall be silicone rubber designed to inflate and provide a tight seal against leakage as pressure on either side of the damper increases. Jamb seals shall be stainless steel compression type. Basis of design is Greenheck Model. Copyright 2011 Greenheck Fan Corporation Rev. 9 Aug 2011