Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Similar documents
Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating Instructions (from serial number 3000)

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Quickstart. English Deutsch Français

Type SE35. Quickstart. English. Flowmeter Flow Transmitter

Type SE36

Types 8025 / Operating Instructions. Bedienungsanleitung Manuel d utilisation. Flowmeter Durchflussmessgerät Débitmètre

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

INSERTION flowmeter with paddle wheel, ELEMENT design

INSERTION flow sensor for continuous flow measurement

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Inductive conductivity meter

Type 6213 EV, 6281 EV

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Operating Instructions (from serial number )

Positive displacement flowmeter

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Type

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Insertion magnetic inductive flowmeter

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Positive displacement flowmeter for continuous flow measurement

Inductive conductivity meter

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Paddle-wheel flow controller for On/Off control

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

Type 8222 ELEMENT. Operating Instructions. Bedienungsanleitung Manuel d utilisation. Conductivity meter Leitfähigkeits-Messgerät Conductivimètre

Type 8635 Remote-Positioner. Zusatzanleitung. English Deutsch Français

Positive displacement batch controller

Paddle-wheel flow controller for On/Off control

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 3320, Service Manual. Serviceanleitung Service Manuel

Paddle-wheel flow controller with optical principle for On/Off control

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Type Pneumatic Control Unit. Operating Instructions

Type Pneumatic Control Unit. Operating Instructions

Type 8222 ELEMENT. Operating Instructions. Bedienungsanleitung Manuel d utilisation. Conductivity meter Leitfähigkeits-Messgerät Conductivimètre

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Type 8222 ELEMENT. Operating Instructions. Bedienungsanleitung Manuel d utilisation. Conductivity meter Leitfähigkeits-Messgerät Conductivimètre

Type 8228 ELEMENT. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Type 3360, Service Manual. Serviceanleitung Service Manuel

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Type 8228 ELEMENT. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Aurora Wind Interface Box

Operating Instruction for Flowmonitor. Model: DF-WM

Type 8798 Remote Sensor. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps

FTB 372 Series Axial Turbine Flow Meter

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

Switching DC Power Supply

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

c-go 24V/6A 24V/8A 24V/12A

Type 2000, 2002, 2012

Digital Pressure Regulator Sentronic PLUS Series 614

Compact System NRGS 11-2 NRGS Original Installation Instructions English

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Differential Pressure Transmitter

Type 2030, 2031, 2031 K, 2032, 2033, 2037

Elektric actuator MC50/24-C

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Micro Diaphragm Gas Sampling Pumps

Micro Diaphragm Gas Sampling Pumps

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Assembly and Maintenance Manual Type ASNU

Inline Paddle Wheel Flow Switch

Operating Instructions CYR52

Type /2-way globe valve 2/2-Wege-Geradsitzventil Vanne à siège droit 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type 2000 Transducer Product Instructions

Technical Documentation

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications

Digital ph transmitter

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Type 3232, 3233, 3233 K, 3234, 3235, 3239

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

WATERFLUX 3070 Quick Start

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Operating Instructions for Torsion Paddle Flow Meter / Monitor. Model: DPT-...

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

IQL Helios Area-/Streetlight. User Manual

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Transcription:

Water flow rate transmitter Wasser-Durchfluss-Transmitter Transmetteur de débit d eau Operating Instructions Bedienungsanleitung Manuel utilisateur

We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Bürkert S.A.S, 2008-2018 Operating Instructions 1808/03_EU-ML_00560456 / Original FR

Contents: 1. About this manual...5 1.1. Symbols used...5 2. intended use...6 3. Basic safety information...6 4. General information...7 4.1. Manufacturer's address and international contacts...7 4.2. Warranty conditions...7 4.3. Information on the Internet...7 5. Description...8 5.1. Area of application...8 5.2. General description...8 5.2.1. Design... 8 5.2.2. Measuring item and principle... 8 5.3. Description of the name plate...9 6. Technical data...9 6.1. Conditions of use...9 6.2. Conformity to standards and directives...9 Water flow rate transmitter type 8081 6.3. Conformity to the pressure equipment directive...9 6.4. General technical data...10 6.4.1. Mechanical data...10 6.4.2. Dimensions...10 6.4.3. Fluid data...10 6.4.4. Electrical data...11 6.4.5. Electrical connections...12 7. Installation and wiring...12 7.1. Safety instructions...12 7.2. Installation onto the pipe...13 7.3. Electrical wiring...14 7.3.1. Assembly of the female cable plug (article number 438680)...15 7.3.2. Wiring of the 5-pin M12 fixed connector...16 7.3.3. Connecting the pulse output...16 7.3.4. Only connecting the current output...17 7.3.5. Connecting both the current and pulse outputs...17 8. Commissioning...18 8.1. Safety instructions...18 3

Contents 9. Adjustment and functions...18 9.1. Safety instructions...18 9.2. Adjustment of the 8081...18 10. Maintenance...19 10.1. Safety instructions...19 10.2. Cleaning...19 11. Packaging, transport...19 12. Storage...19 13. Disposal of the product...20 4

About this manual 1. About this manual This manual describes the entire life cycle of the device. Please keep this manual in a safe place, accessible to all users and any new owners. This manual contains important safety information. Failure to comply with these instructions can lead to hazardous situations. This manual must be read and understood. caution Warns against a possible risk. Failure to observe this warning can result in substantial or minor injuries. Notice Warns against material damage. Failure to observe this warning can result in damage to the device or system. 1.1. Symbols used danger Warns against an imminent danger. Failure to observe this warning can result in death or in serious injury. Warning Warns against a potentially dangerous situation. Failure to observe this warning can result in serious injury or even death. indicates additional information, advice or important recommendations. refers to information contained in this manual or in other documents. indicates a procedure to be carried out. 5

intended use 2. intended use Use of the ultrasonic flow rate transmitter that does not comply with the instructions could present risks to people, nearby installations and the environment. The 8081 transmitter is intended solely for the measurement of the flow rate in water or neutral liquids. If possible, avoid placing this device near sources of electromagnetic interference This device must be protected against ultraviolet rays and, when installed outdoors, the effects of the climatic conditions. This device must be used in compliance with the characteristics and commissioning and use conditions specified in the contractual documents and in the user manual. The device can only be used together with devices and components recommended and/or approved by Bürkert. Requirements for safe and proper operation are proper transport, storage and installation as well as careful operation and maintenance Only use the device as intended. 3. Basic safety information This safety information does not take into account: any contingencies or occurences that may arise during assembly, use and maintenance of the devices. the local safety regulations that the operator must ensure the staff in charge of assembly observe. Danger due to high pressure. Danger due to high temperatures of the fluid. Danger due to electrical voltage. Various dangerous situations To avoid injury take care: to prevent any power supply switch on. to carry out the installation and maintenance work by qualified and skilled staff with the appropriate tools. to guarantee a set or controlled restarting of the process, after a power supply interruption. to use the device only if in perfect working order and in compliance with the instructions provided in the user manual to observe the general technical rules during the planning and use of the device. 6

General information 4. General information Various dangerous situations To avoid injury take care: not to use the type 8081 ultrasound flow rate transmitter in a potentially explosive atmosphere. not to use fluid that is incompatible with the materials of which the transmitter is made. not to subject the device to mechanical loads (e.g. by placing objects on top of it or by using it as a step). not to make any external modifications to the device. Do not paint or varnish any part of the device. notice Elements / Components sensitive to electrostatic discharges This device contains electronic components sensitive to electrostatic discharges. They can get damaged if they are touched by an electrostatically charged person or object. In the worst case scenario, these components are instantly destroyed or go out of order as soon as they are activated. To minimise or even avoid all damage due to an electrostatic discharge, take all the precautions described in the EN 61340-5-1 norm. Also ensure that you do not touch any of the live electrical components. 4.1. Manufacturer's address and international contacts To contact the manufacturer of the device use following address: Bürkert SAS Rue du Giessen BP 21 F-67220 TRIEMBACH-AU-VAL You may also contact your local Bürkert sales office. The addresses of our international sales offices can be found on the last pages of this manual. They are also available on the Internet at: www.burkert.com 4.2. Warranty conditions The condition governing the legal warranty is the conforming use of the 8081 in observance of the operating conditions specified in this manual. 4.3. Information on the Internet You can find the user manuals and technical data sheets regarding the type 8081 at: www.burkert.com 7

Description 5. Description 5.1. Area of application The ultrasonic flow rate transmitter type 8081 is intended for the measurement of water flow rates which may be slightly charged with contaminants. 5.2. General description 5.2.1. Design The 8081 ultrasonic flow rate transmitter consists of an electronic module and a brass fitting with a built-in measuring tube. When combined with a controller and a control loop, it enables a control loop to be established. The electrical connection is made via a 5-pin M12 fixed connector. The transmitter features, depending on the version: a pulse output or a pulse output and a 4...20 ma current output; Each version is available for 5 different flow rate ranges: model QN 0.6 DN15: 0.06 to 20 l/min (nominal flow rate 0.6 m 3 /h namely 10 l/min) model QN 1.5 DN15: 0.1 to 50 l/min (nominal flow rate 1.5 m 3 /h namely 25 l/min) model QN 2.5 DN20: 0.16 to 82 l/min (nominal flow rate 2.5 m 3 /h namely 41 l/min) model QN 3.5 DN25: 0.6 to 116 l/min (nominal flow rate 3.5 m 3 /h namely 58 l/min) model QN 6 DN25: 1 to 200 l/min (nominal flow rate 6 m 3 /h namely 100 l/min) 5.2.2. Measuring item and principle The 8081 flow meter is based on the transit time method. This consists in measuring the transit times of the sound from emitter 1 to receiver 2 and from emitter 2 to receiver 1 and subsequently comparing both values. The calculated transist time difference is directly proportional to the flow speed of the fluid. ultrasonic wave 1 ultrasonic wave 2 emitter-receiver emitter-receiver 1 2 t 0 t 1 t 2 t Direction of flow of the fluid The electronic module then delivers a pulse signal proportional to the volume or an industry-standard 4...20 ma signal, proportional to the flow rate or to the temperature. 8

Technical data 5.3. Description of the name plate 1. Measured quantity, type of flow meter 2. Supply voltage 3. Measuring principle 4. Nominal flow rate 5. Output data 6. Process connection 7. Flow rate range 8. Manufacturing code 9. Serial number 10. Article number 11. Materials: housing, seal 1 2 3 4 6. Technical data 6.1. Conditions of use Ambient temperature: +5...+55 C Storage temperature: +5...+55 C Air humidity: Protection rating: < 80 %, not condensated IP65 with cable plug plugged-in and tightened 6.2. Conformity to standards and directives The applied standards, which verify conformity with the EU directives, can be found on the EU-type examination certificate and/or the EU declaration of conformity (if applicable). Made in France 11 FLOW8081 ULTRAS QN2.5 NPN/PNP : 0,7A - 36VDC 12-36 VDC 4-20mA G1 MSEPDMFKM 0,16-82L/MIN S/N 1000 00559869 W41LP 10 9 8 5 6 7 6.3. Conformity to the pressure equipment directive The device conforms to Article 4, Paragraph 1 of the Pressure Equipment Directive 2014/68/EU under the following conditions: Device used on a pipe (depending on the maximum pressure, the DN of the pipe and the fluid) 9

Technical data Type of fluid Fluid group 1, Article 4, Paragraph 1.c.i Fluid group 2,Article 4, Paragraph 1.c.i Fluid group 1, Article 4, Paragraph 1.c.ii Fluid group 2, Article 4, Paragraph 1.c.ii 6.4. General technical data 6.4.1. Mechanical data Item Housing, cover Seal in contact with the environment M12 connector Fitting Measuring tube Seal in contact with the fluid Material PPS Silicone PA Brass PES EPDM, FKM Conditions Forbidden DN 32 or PSxDN 1000 Forbidden DN 200 or PS 10 or PSxDN 5000 6.4.2. Dimensions Please refer to the technical data sheets related to the product / device at: www.burkert.com 6.4.3. Fluid data Pipe diameter DN15 to DN25 Type of fluid water (or neutral liquids on request) Fluid temperature +5...+90 C Fluid pressure PN 16 Measuring range 0.06...200 l/min Accuracy (see curves on next page) ± (0.01 % of Full Scale* +2 % of measured value) 1) Repeatability 1 % of measured value Measuring element 2 ultrasound emitter-receiver cells * Full Scale, see measuring range on the diagram of measurement accuracy. 1) Reference conditions: fluid = water, water and ambient temperatures = 20 C 10

Technical data Measurement accuracy Max. measurement max DN15 max DN20 deviation in % max DN25 10 8 6 4 2 0-2 -4-6 -8-10 0,1 1 10 100 1000 Flow rate in l/min 6.4.4. Electrical data Supply voltage (V+) Current consumption Pulse output (transistor) version without current output version with current output 12...36 V DC Own consumption: < 4 ma Consumption with load: < 1 A NPN as default setting; (PNP on request), open collector, 5 ma min., 700 ma max., NPN output: 0,2...36 V DC PNP as default setting; (on request: NPN for the pulse output and sinking mode for the current output), open collector, 5 ma min., 700 ma max., PNP output: supply voltage (V+) If QN=0.6 or 1.5: 1 pulse corresponds to a volume V = 0.002 l (K factor = 500 pulse/litre) If QN=2.5 or 3.5: 1 pulse corresponds to a volume V = 0.005 l (K factor = 200 pulse/litre) If QN=6: 1 pulse corresponds to a volume V = 0.01 l (K factor = 100 pulse/litre) 11

Installation and wiring Current output Protection against: reversed polarity voltage peaks short-circuits 4...20 ma (sourcing mode as default setting; on request: sinking mode for the current output and NPN for the pulse output) corresponding to the flow rate range of the selected model max. loop resistance: 1100 W at 36 V DC 610 W at 24 V DC 100 W at 12 V DC yes yes yes, for the pulse output Recommended cable type max. cross section of 1.5 mm 2 6.4.5. Electrical connections 7. Installation and wiring 7.1. Safety instructions danger Risk of injury due to high pressure Cut off the pressure and depressurize the pipes before loosening the pipes and connections. Risk of injury due electrical discharge. If the device is installed either in a wet environment or outdoors, all the electrical voltages must be of max. 35 V DC. Before starting work, make sure that you switch off the supply voltage and secure it to prevent restarting. Observe all applicable accident protection and safety guidelines for electrical equipment. Warning Flow rate meter version Any version Type of cable plug female 5-pin M12 cable plug (available as an accessory; Article number 438680) Risk of injury due to non-conforming installation. The electrical and fluid installation can only be carried out by qualified and skilled staff with the appropriate tools Install appropriate safety devices (correctly rated fuse and/or circuit-breaker). Use cables with an operating temperature limit which is suitable for your application. Under normal conditions of use, cables with a 0.75 mm 2 cross section should be enough to transmit the signal. 12

Installation and wiring Warning Risk of injury due to unintentional switch on of power supply or uncontrolled restarting of the installation. Take appropriate measures to avoid any involuntary activation of the installation. Guarantee a set or controlled restarting of the process subsequent to the assembly of the device. notice When the cover is removed, the transmitter may be damaged through any element touching the electronics, and the tightness of the transmitter is no longer ensured. Do not dismantle the device 7.2. Installation onto the pipe Correct Correct Incorrect Incorrect When horizontally mounted, the max. fluid temperature is 90 C. But the max. fluid temperature must be reduced to 80 C when the electronics (black enclosure) is turned upwards. When vertically mounted the max. fluid temperature is also 80 C. Please be careful to respect the correct direction of fluid flow in the pipe. It is indicated with an arrow, marked on the underside of the fitting. danger Risk of injury due to high pressure in the installation. Cut off the pressure and depressurize the pipes before loosening the pipes and connections. The 8081 ultrasonic flow rate transmitter can be fitted onto a horizontal or vertical pipe. It is advisable to avoid placing the 8081 transmitter near any source of electromagnetic interference (switch, electric motor, fluorescent lamp,...). 13

Installation and wiring Minimum upstream and downstream distances are not necessary. The 8081 works correctly when the pipe is full and free of any air bubbles near the transmitter. In presence of bubbles in the pipe, the left installation no.1 should be avoided. notice When mounting the device on the pipe, the M12 fixed connector may be damaged. If the M12 fixed connector is damaged the device cannot be used anymore. Please be careful not to damage the M12 fixed connector when mounting the device on the pipe. 7.3. Electrical wiring 1 2 3 4 If the absence of any air bubbles cannot be guaranteed, the device should then be fitted on an horizontal pipe, with the electronic enclosure facing down. Thus the bubbles will not interfere with the circulation of ultrasonic waves. danger Risk of injury due to electrical discharge If the device is installed either in a wet environment or outdoors, all the electrical voltages must be of max. 35 V DC. Before starting work, make sure that you switch off the supply voltage and secure it to prevent restarting. Do not install the cable near high voltage or high frequency cables. If this is unavoidable, keep to a minimum clearance of 30 cm. Observe all applicable accident protection and safety guidelines for electrical equipment 14

Installation and wiring The power supply must be filtered and regulated. Make sure the installation is earthed equipotentially (power supply - 8081). Connect the different earth connections of the installation to one another in order to remove any differences in potential which may arise between the two earth connections. Connect the cable shielding to the earth. Connect the negative terminal of the power supply to the earth to remove the effects of the common mode currents. If this connection cannot be made directly, a 100 nf / 50 V capacitor can be fitted between the negative terminal of the power supply and the earth. (**) + - 12-36VDC (*) (*) If a direct earthing connection is not possible, fit a 100 nf / 50 V capacitor between the negative terminal of the power supply and the earth. 7.3.1. Assembly of the female cable plug (article number 438680) 1 2 3 4 5 Fully unscrew terminal block [1] Remove body [2]. Unscrew clamping nut [5]. Pass cables through clamping nut [5], then through clamp ring [4] and gasket [3], and finally through body [2]. Wire terminal block [1] (acc. to 7.3.2, 7.3.3, 7.3.4 or 7.3.5) Screw terminal block [1] onto body [2]. Insert gasket [3] and clamp ring [4] into body [2]. Screw clamping nut [5]. (**) If your cable is shielded. 15

Installation and wiring 7.3.2. Wiring of the 5-pin M12 fixed connector Not connected (*) 5 4 V+ (12-30 VDC) 3 1 2 0 VDC Pulse output (NPN default setting) Wiring a version with pulse output 4...20 ma (*) (*) Functional earth connection 4 3 5 1 2 0 VDC V+ (12-30 VDC) Pulse output (PNP default setting) Wiring a version with pulse and current outputs Pin of M12 cable plug with a 2 m cable available as accessory Colour of wire (article number 438680) 1 brown 2 white 3 blue 4 black 5 grey 7.3.3. Connecting the pulse output The pulse output is connected in NPN mode (default setting on a version without current output) or in PNP mode (default setting on a version with current output). Load white 2 5 1 brown 3 4 blue grey NPN connection 12-36 VDC + - Load white 2 5 1 brown 3 4 blue grey PNP connection 12-36 VDC + - 16

Installation and wiring 7.3.4. Only connecting the current output The current output, where present, is connected in source mode (default setting) or in sink mode (on request). 4...20 ma input 4...20 ma input 7.3.5. Connecting both the current and pulse outputs Load Load black + - 2 5 1 brown 3 4 blue grey (*) Supply 12-36 VDC + - black + - 2 5 1brown 3 4 blue grey (*) Supply 12-36 VDC + - black white 2 brown 3 1 4 blue grey black white 2 brown 3 1 4 blue grey Source mode connection (default setting) Sink mode connection (on request) (*) If a direct earthing connection is not possible, fit a 100 nf / 50 V capacitor between the negative terminal of the power supply and the earth. 4...20 ma input 12-36 VDC Supply + - + - (*) 4...20 ma input 12-36 VDC Supply + - + - (*) PNP/sourcing mode connection (default setting) NPN/sinking mode connection (on request) (*) If a direct earthing connection is not possible, fit a 100 nf / 50 V capacitor between the negative terminal of the power supply and the earth. 17

Commissioning 8. Commissioning 8.1. Safety instructions Warning Danger due to non-conforming commissioning. Non-conforming commissioning could lead to injuries and damage the device and its surroundings. Before commissioning, make sure that the staff in charge have read and fully understood the contents of the manual. In particular, observe the safety recommendations and standard operating practices. The device/installation must only be commissioned by suitably trained staff. Protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, the effects of the climatic conditions. 9. Adjustment and functions 9.1. Safety instructions Warning Risk of injury due to non-conforming adjustment. The operators in charge of adjustment must have read and understood the contents of this manual. In particular, observe the safety recommendations and standard operating practices. The device/installation must only be adjusted by suitably trained staff. 9.2. Adjustment of the 8081 Pulse output: The pulse output delivers a frequency in proportion to a volume. A pulse is generated each time a set volume passes, i.e. either V = 0.002 litre (for a model with QN = 0.6 or 1.5) or V = 0.005 litre (for a model with QN = 2.5 or 3.5) or V = 0.01 litre (for a model with QN = 6). Current output: The current output, where present, is pre-programmed on the current range corresponding to the flow rate range (QN0.6, QN1.5, QN2.5, QN 3.5 or QN6) of the selected 8081 model. 18

Maintenance 10. Maintenance 10.1. Safety instructions danger Risk of injury due to high pressure in the installation. Cut off the pressure and depressurize the pipes before loosening the pipes and connections. Risk of injury due to electrical discharge. If the device is installed either in a wet environment or outdoors, all the electrical voltages must be of max. 35 V DC. Before starting work, be sure to switch off the supply voltage and secure it to prevent restarting. Observe the applicable accident prevention and safety regulations for electrical equipment. Warning Danger due to non-conforming maintenance. Maintenance must only be carried out by qualified and skilled staff with the appropriate tools. Following maintenance, ensure a controlled restart. 10.2. Cleaning The 8081 flow meter can be cleaned with water or using a detergent compatible with the materials it is made of. Please feel free to contact your Bürkert supplier for any additional information. 11. packaging, transport notice Damage due to transport Transport may damage an insufficiently protected device. Transport the device in shock-resistant packaging and away from humidity and dirt. Avoid the effects of heat and cold which could cause the storage temperature range to be exceeded. Protect the electrical interfaces by using protection caps. 12. StorAGe notice Poor storage can damage the device. Store the device in a dry place away from dust. Storage temperature: +5...+55 C. 19

Disposal of the product 13. Disposal of the product Dispose of the device and its packaging in an environmentallyfriendly way. notice Damage to the environment caused by products contaminated by fluids. Keep to the existing provisions on the subject of waste disposal and environmental protection. Please note: Comply with the national and/or local regulations which concern the area of waste disposal. 20

www.burkert.com