LK Manifold Shunt VS2

Similar documents
LK Manifold Shunt VS 2-2,5

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

Products for underfloor heating

LK Manifold RF. Design. Requirements

LK Manifold RF. Design. Requirements. Documentation

LK Shunt Cabinet VS2, Shunt Cabinet VS2 Prefab

MANIFOLDS & WATER TEMPERATURE CONTROL

PRODUCTS FOR HEATING AND TAP WATER SYSTEMS. Product Catalogue

LK Control v.3 & LK Control v.3 - RA

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

Delta HE 35-XX, 55-XX

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump

THE NEW GENERATION MIXING VALVES. NEWS LK 840 ThermoMix 2.0 LK 841 ThermoMix 2.0

MrPEX 1 ¼ Stainless Steel Manifold Installation Guide

FCU Floor Control Unit

Pump Stations for Heating Circuits

Art.918C Pre-assembled manifold with flow meters, air

COMPONENTS FOR SOLAR THERMAL SYSTEMS

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

Premounted Midi Shunts

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

LK 820 ThermoVar. Technical Data. Thermic Valves and Check Valves. Opening temperatures 45 C, 55 C, 61 C, 66 C, 72 C or 80 C.

Characterized Port -CP Three-Way Ball Valves

Components for central heating

Controls and valves for heating systems

AV 23 Balancing valves SETTER Inline

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

EV RANGE MULTI-SPEED GLANDLESS CIRCULATORS

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

SERIES 2000 GAS SAFETY SHUT OFF VALVE

Underfloor Heating Manifold Control Kit

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Modulating control valve PN16 with magnetic actuator

Floor heating manifold with automatic flow control

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

Modulating control valve PN16 with magnetic actuator

High capacity valve body, type RA-G

ZONE CONTROLE / 2-WAY

4-Way Mixing Panel Submittal - Page 1 of 6

Product range Solex Technical data and dimensioning. 5 Years

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

Product and installation manual. Underfloor Heating Composite Manifold

COMPONENTS FOR SOLAR THERMAL SYSTEMS

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

Fan-coil valves Series

High Capacity Valve Body, Type RA-G

Electro Controls. Valves / Linkages WattsIndustries.co.uk

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Modulating control valves with magnetic actuators, PN 16

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Pressure independent balancing and control valve For ON/OFF control

CALEFFI. HydroMixer motorized temperature mixing unit. 167 series 01239/13 NA. Function

Pressure independent combined control and balancing valves with independent EQM characteristics

Seated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

Data sheet: Wilo-Stratos PICO 25/1-6

MULTI-FLUID SOLENOID VALVES 1/8 AND 1/4

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

PRESSURE CONTROL VALVES SABS 198

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Premounted Midi Shunts

Data sheet: Wilo-Stratos PICO 25/

ADDENDUM to INSTALLATION INSTRUCTIONS for Grant Solar Pump Station

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

This catalog contains the following geothermal accessory products and specification guides:

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Zone Valves and Parts (Honeywell)

26 Series Stainless Steel 2-way Ball Valves

Serie Ekoflux S. Flanged balancing valve. Application fields. Regulation. Ekoflux.S_GB_22/04/2015 HEATING CONDITIONING

Preassembled manifolds with flow meter, series CPRFL

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

NV Direct Coupled Globe Valve Actuator

AIR COOLED CHILLERS WATER COOLED CHILLERS

Pressure sensor for liquid and gaseous media QBE620-P...

Connections (*) Actuator Power MVX V ON/OFF MVX41 MVR24V MVR24MV (3) 24 V. Rev. h 07/10 1 DBL199E

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

dynacon floor heating manifold with automatic flow control

TA-FUS1ON-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

Manifold Isolation Valves

Manifolds series 73A and 77A. Instruction manual

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

ELECTRIC ACTUATORS 400 N

Automatic back-flushing filter AutoFilt RF4

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Valve monitoring system VDK 200 A S02

T2 Wall Hung Radiator & UFH Manifolds

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Modulating control valve PN16

ROTARY MOTORIZED VALVES

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Flow volume: 2-24 l/min Max differential pressure: 10 bar Applications: Lubrication, circulation and transfer

Seated valves VF 2, VL 2-2-way VF 3, VL 3-3-way

Transcription:

LK Manifold Shunt VS2 Design LK Manifold Shunt VS2 is a shunt unit with a two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds. The shunt unit is fitted as standard with a hand actuator on the control valve and with an adjustable maximum limit function of supply temperature. The pump has automatic speed-control for reduced energy consumption and quieter operation. Guideline capacity of this shunt unit is 200 m 2 floor surface. Capacity is however dependent on primary temperature, pressure, laying method etc. Suitable for underfloor heating areas up to 200 m 2. Compact design. Energy efficient circulation pump. Thermostat-controlled maximum limit of supply temperature. VF valve. Right or left mounting. Can be supplemented with a unit for weather dependent temperature control, LK Control v.3. Supplied with product Delivered as a complete unit, including: Accessories LK Control v.3 Installation cabinets for built-in or wall mounting, see heading Assembly in LK Installation cabinets. The valve actuator for 230 V or 0-10 V to connect to external control equipment. Circulation pump Grundfos UPM3 Auto L 15-70 with automatic speed control. Supply pipe in two versions, for right and left mounting respectively. 2 thermometers to measure secondary supply and return temperature. Bracket. LK Control v.3 1 (9)

LK Manifold Shunt VS2, overview 11 10 8 9 12 6 7 13 14 5 15 4 3 2 1 1. Supply flow from primary circuit. Female threads ¾. 2. Locking control valve. Only used to close the primary side, if the primary pressure exceeds 3 bar, see heading below, Shutting off primary side. 3. Return flow connection to primary circuit. Female threads ¾. 4. Isolation/flow control valve primary return (V2). Valve for adjustment and control of the primary flow. Also used as isolation valve. 8 mm hexagonal socket. 5. Return flow from the underfloor heating circuit. Male threads 1. 6. Built-in thermometers located in the underfloor heating return flow 7. Bracket. 8. VF Valve (VF). Should only be used in installations with low available drive pressure from the primary side of the circulation pump. 8 mm hexagonal socket. 9. Built-in check valve. 10. Pump connector. 11. Supply flow to underfloor heating circuit. Male threads 1. 12. Circulation pump Grundfos UPM3 Auto L 15-70 with automatic speed control. 13. Temperature limiter (TEMP). Factory-set to 50 C. Adjustable between 22-65 C, see table below. 14. Built-in thermometers located in the underfloor heating supply flow 15. Two-way control valve (V1). The control valve is fitted with a hand actuator to manually adjust the supply flow temperature. May be replaced by motorized valve actuators, see LK Control v.3. The valve is also used to close the primary side, see heading below, Shutting off primary side. 2 (9)

Requirements The manual control version of LK Manifold Shunt VS2 should be used in systems with a primary supply temperature that is weather dependent. Check the settings of the temperature limiter control. Otherwise, it is advisable to fit the shunt unit with LK Control v.3 to ensure optimum operational comfort and low energy consumption. The heating system must before assembly be flushed through and must not contain any impurities or additives that can damage the LK Manifold Shunt VS2. Max. 50% glycol or 30% ethanol mix. Note! Be aware of the fire hazard when mixing with ethanol and the resilience of other components to the ethanol mix. During assembly, ensure that the pump axle is horizontal and that any valve actuators are not placed below the control valve. When choosing a suitable location for installation, pay attention to any possible structure-borne noise. Assembly By-pass The shunt unit is fitted with an automatic speed controlled pump, which means the manifold does not require a mechanical By-Pass. Assembly in LK Installation Cabinet The shunt unit can be mounted together with the LK Manifold in specially designed cabinets in accordance with industry practices. The cabinets have a sealed base with rubber pipe inlets. The base has a drainage opening which allows any water leakage to drain to a location which can be inspected. LK Shunt Cabinet VS2 The LK Shunt Cabinet VS2 can be installed in a wall or externally on a wall. When installing in a wall then the LK Frame/hatch UFH INB is used to cover the hole in the wall. When the cabinet is installed externally on a wall, the LK Frame/hatch UFH UTV is used, which fits edge to edge with the outsides of the cabinet. Supplement with LK Base, which hides the pipes between the cabinet and the floor when mounting the cabinet externally. The shunt unit can be mounted directly to LK Manifolds from both the right and left. To facilitate this, two Manifold Supply Pipes are supplied, where the shorter is used for right mounting, see illustration above. When fitting from the left, move the thermometers to the opposite side of the shunt unit and use the longer pipe. LK Shunt Cabinet VS2 800 holds LK Manifold Shunt VS2 and LK Manifold RF 2-7. LK Shunt Cabinet VS2 1050 holds LK Manifold Shunt VS2 and LK Manifold RF 2-12. Note! When installing the LK Shunt Cabinet VS2 in a wall, a minimum stud-frame thickness of 95 mm with 13 mm wall covering is required. The shunt unit is placed to the right of the manifold, see instructions for LK Shunt Cabinet VS2. 3 (9)

LK Manifold Cabinet INB/UTV The following cabinet does not fulfil Swedish plumbing for water tightness regulations, and is therefore not normally sold on the Swedish market. LK Manifold Cabinet INB 800 holds LK Manifold Shunt VS2 and LK Manifold RF 2-7. LK Manifold Cabinet INB 1150 holds LK Manifold Shunt VS2 and LK Manifold RF 2-12. LK Manifold Cabinet UTV 800 holds LK Manifold Shunt VS2 and LK Manifold RF 2-7. LK Manifold Cabinet UTV 1150 holds LK Manifold Shunt VS2 and LK Manifold RF 2-12. Note! Ensure that the pump never runs dry and the system is well vented before use. Operating mode Grundfos UPM3 Auto L indicates in normal operation the power used by the pump (stated in per cent of maximum capacity) in accordance with the table below. Note! When installing the LK Manifold Cabinet INB in a wall, a minimum stud-frame thickness of 95 mm with 13 mm wall covering is required. Circulation pump The circulation pump has automatic speed control, which reduces power consumption and gives a quieter operation as the pump adjusts the flow according to the requirements of the system. A cast arrow on the pump housing indicates the direction of the flow. For underfloor heating it is recommended that the pump is set to constant pressure control, see capacity diagram below. Select the constant pressure curve which best matches the design system flow and pressure drop, choose between the curve CONST. PRESS. CURVE 1, 2 or 3. Table, overview of operating mode To show the setting currently in use by the pump, give the arrow button a short press. Read the selected mode by studying the settings menu below. After two seconds, the indicator returns to operating mode. Settings To change the pump setting press the arrow button on the pump for 2-10 seconds, and the pump will show the selected setting in accordance with the settings menu. Pressing the button shifts the pump between the different settings. Adjust to the desired setting using the menu. QR code for the installation instructions for UPM3 4 (9)

Settings menu Electrical connection The electrical connection is easily set up with the accompanying plug, with built-in strain relief. The plug no longer requires a 2-pole switch disconnecter. The circulation pump has built-in thermal motor protection The electrical connection must be fused with Max. 10 A slow blow fuse. Alarm codes In the event of an operating problem then a fault code will be displayed as below. Display Indication Operation Action Red LED, Yellow LED #5 Red LED, Yellow LED #4 Red LED, Yellow LED #3 Blocked rotor Too low voltage Electric fault Start attempt each 1.33 sec. Only warning, the pump operates as normal Pump stopped because of low voltage or serious fault Wait or release rotor Check the voltage to the pump Check voltage to pump / Replace pump Overview of settings options for the UPM3. Relevant settings are marked with a blue rectangle, other settings are shaded. Capacity chart P (kpa) 70 60 50 CC MAX CC III CC II Cp1 Cp2 Cp3 40 30 20 10 Cp3 Cp2 Cp1 CC I 0 0 5 10 15 20 25 30 35 40 Q (l/min) 5 (9)

Setting for temperature limiter (TEMP) The temperature limiter can be set between 22-65 C. The factory setting is about 50 C. Always check the setting at the time of installation; refer to the table below. LK Control v.3 (accessory) Settings for the temperature limiter (TEMP) 0 22 C 1 30 C 2 37 C 3 45 C 4 53 C 5 65 C Max. temperature Underfloor heating with constant supply temperature The shunt unit can also be used in an underfloor heating system where a constant supply temperature is needed. Close control valve (V1). Reduce the temperature controller (TEMP) to a projected supply temperature, normally about 40 C. Then, open the control valve until about 40 C is read off the flow-side thermometer Flow control valve (V2) Return flow primary circuit The estimated primary flow can be adjusted using the shunt unit's return valve, as shown in the table below. Revolutions Fully open. 1 3.9 2 3.7 3 3.4 4 3.0 5 2.6 6 2.1 7 1.7 8 1.2 9 0.8 10 0.4 11 0.2 12 0.0 Kv (m 3 /h) 4.1 Kvs The LK Control v.3 is a complete unit for weather dependent temperature control, adapted and pre-programmed for LK s floor heating systems. The LK Control v.3 consists of a control unit, valve actuator as well as a flow and outdoor temperature sensor. As an option, the LK Control v.3 can be supplemented with the LK Room Unit v.3 for regulating room temperature to the control unit s heat curve. This function is similar to a room thermostat, but with the possibility of remote control of the control unit. The LK Room Unit v.3 is often used in areas with an open floor plan where only one room sensor is needed. When mounting the LK Control v.3 the shunt group's hand actuator must be removed and replaced with the valve actuator, which is enclosed with the LK Control v.3. See illustrations below for placement and installation. 6 (9)

1 3 2 4 Locking the control valve. 1. Close the control valve (V1) by unscrewing the hand actuator anti-clockwise to its farthest position. 2. Dismantle the cover, see illustration below. 3. Screw in the cone (hex 4 mm) to lock the control valve. 1 2 5 3 1. Unscrew the handle on the hand actuator (anti-clockwise). 2. Pull out the clasp. 3. Remove the hand actuator 4. Remove the spindle extension 5. Install the valve actuator. Shutting off primary side The shunt unit can be used to shut off the primary side, e.g. during service work on the shunt unit or underfloor heating manifold. 1 2 1. The primary side's return is shut off by screwing the cone clockwise for the control valve (V2). 2. The primary side's flow is shut off by unscrewing the hand actuator on the control valve (V1), i.e. screwing out anti-clockwise to its farthest position. Note! The control valve remains sealed for a primary pressure of up to about 3 bar. Above 3 bar the control valve's cone must be locked. This may be needed for larger installations with a relatively high static pressure. The valve is now sealed for pressure above 3 bar. Note! When service has been completed, remember to fully open the control valve lock and then open the control valve with the hand actuator. Troubleshooting The floor heating circuit is not heating up or not heating sufficiently. Check that the control valves (V1+V2) are open. See heading, Shutting off primary side. Check settings for the control valve (V1). Are the actuator and adjustment valves open for the underfloor heating manifold? Check the settings for the temperature limiter (TEMP). Check that the correct pump curve is selected. If the above checks have been completed and the heat to the manifold is still insufficient, this may suggest too little drive pressure from the primary side's main circulation pump (normally located at the heat source). Check the main circulation pump's operation and whether this can be increased. If this does not rectify the situation, the circulation pump of the manifold shunt can help to "draw" the water from the primary side to the underfloor heating side by gradually closing the VF valve until the correct temperature is reached. 7 (9)

Technical data Article number 243 52 14 Max. operating pressure Max. pressure differential in operation Operational temperature secondary Operational temperature primary 1.0 MPa 0.1 MPa +12 - +65 C Max. 80 C Ambient temperature Max. 70 C Max. valve capacity control valve V1 with hand actuator fitted. Max. valve capacity control valve V1 with electric valve actuator. Kv 2.2 Kvs 3.6 Control valve V2 Kvs 4.1 Material Media Circulation pump Nickel-plated brass MS58, stainless acid-proof steel Water, water/glycol 50/50%, water/ethanol 70/30% Grundfos UPM3 Auto L 15-70, with cast iron pump housing Voltage 1 phase 230V AC, -15 % / +10 %, 50 Hz, PE Output Current Cable protection class Max. 52 W Max. 0.52 A IP44 Relative humidity Max. 95% Approved pump CE, EC Low Voltage Directive (2006/95/ EC) incl. additions Flow diagram C 12 TEMP 15. Control valve (V1). T A 13 9 8 F B 15 4 4. Isolation/flow control valve primary return (V2). V1 13. Temperature limiter (TEMP). 12. Circulation pump. 9. Built-in check valve. 8. VF Valve (VF). VF V2 A. Control unit (LK Control v.3) accessory. B. Supply flow sensor (LK Control v.3) accessory. C. Outdoor sensor (LK Control v.3) accessory. D. Room unit (LK Control v.3) accessory. E. Secondary side underfloor heating system. F. Primary side, system with main pump. E D 8 (9)

Dimensions drawing Left Right LK Systems AB, Box 66, 161 26 Bromma, Sweden www.lksystems.se 9 (9)