SENTINEL BATTERY MONITORING

Similar documents
Integrated Inverter/Battery Monitoring System (IBMS)

Battery Monitoring System

Battery Management at it's best! Technologies

Battery Monitoring Why Technology Matters. Mats Karlstrom V.P. Sales & Marketing, Alber

Est Battery Data Logger BDL3000

Battery Monitor Products. Trust Your Batteries TM. Doing it right!

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Battery Monitoring Systems

Cellwatch Battery Monitoring Systems

Stationary Batteries: Why they fail and what can be done to prolong battery life

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

User Manual. Solar Charge Controller 3KW

RF80-M. Features. Lead Acid Batteries Multistep Programmable. Automatic Operation Stores 100 Programs

Maintaining the operating temperature of the battery at 20 C to 25 C will maximize its service life and efficiency.

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

User Manual Solar Charge Controller 3KW

Hydro Plant Risk Assessment Guide

Battery Maintenance Solutions for Critical Facilities

Technical Note. Management of Sealed Lead Acid Batteries in Reliable Small DC Standby Power Supply Systems

Battery Technology for Data Centers and Network Rooms: Site Planning

Automatic DC Power Supply/Battery Charger

TRIPS AND FAULT FINDING

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

Low and medium voltage service. Power Care Customer Support Agreements

icon Solar Battery Charge Controller for Home UPS

Why Ni-Cd batteries are superior to VRLA batteries. Statements and facts

BATTERY TESTING SOLUTIONS

Proper Torque Values for Connection Hardware. 90 to 100 in-lbs

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

INTRODUCTION. Specifications. Operating voltage range:

BMS-3923 Battery Monitoring System

Model UPS NXRT-1000 NXRT-1500 NXRT-2000 NXRT-3000 Model EBP NXRT-EBP1 NXRT-EBP2 NXRT-EBP3 NXRT-EBP3

INTELEPOWER CXS SWITCHING SYSTEMS

VALEO HEVAC (P38 NRR) - System Overview

REOZM SERIES GENERATORS. for Industrial Power Systems 835 kva 2500 kva 668 kw 2000 kw

Stationary Battery Testing

Remote Condition Monitoring

Long-Term Costs and Savings of Properly Rewound Motors

INTRODUCTION MARKET SECTORS CUSTOMER SERVICE CCL OFFERS YOU. Switchmode Technology A highly efficient, lightweight

UPS FEATURES & BENEFITS TECHNICAL DATA Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications.

OPTIMISING SEWAGE PUMPING STATION PERFORMANCE

AN INTRODUCTION TO THE BENEFITS OF IMPRES ENERGY SOLUTIONS

Foreword

With Cummins PowerCommand Cloud, you can ensure you are always on.

One-Stop Service: Monitoring and Managing.

3400W Solar Battery Charger Maximum Power Point Tracker

Station dc supply voltage. Electrolyte level. Inspect: Verify:

HYBRID POWER FOR TELECOM SITES

TECHNICAL BULLETIN Fig #1 - VRLA Battery Components. Intercell Welded Connection Strap joining neg. plates in parallel.

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Technical Guide Smart Technology and Solar Street Lights

Battery Storage Systems

3400W Solar Battery Charger Maximum Power Point Tracker

Genset Starting Education Module #3: Solutions to Leading Causes of Battery Failure in Gensets

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS

TRW Commercial Steering Diagnostic Tool

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

Business Case for Battery Monitoring

Deep Cycle Battery Safety. First. Battery Handling, Maintenance & Test Procedures

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1.

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

The Traveler Series TM : Adventurer

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

Magellan Utility Scale Energy Storage

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Factory Data: MOSFET Controls Supercapacitor Power Dissipation

HOPPECKE Lithium-ion battery systems

Three Phase UPS Systems Range: 10 to 500kVA

The Traveler Series: Adventurer

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Transforming Transforming Advanced transformer control and monitoring with TEC

PRODUCT CATALOG YOUR PARTNER IN CRITICAL POWER SOLUTIONS

CONNECTED SERVICEs TACHOGRAPH SOLUTIONS

Contact-Cooled Rotary Screw Air Compressors. Nirvana kw ( hp)

3400W Solar Battery Charger Maximum Power Point Tracker

Boosters. DN C Series. Pressures to 650 psig Capacities 102 to 692 cfm. kaeser.com

MP Access Charger.

Critical Battery Monitoring, Testing, & Charging Solutions

MGE TM Galaxy TM 7000

Modbus Register Map:Galaxy VM (3: kVA 400/480V)

3ph UPS NS3000 series kVA

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

Standby Battery Life Management: Breaking the Price Barrier

» Eco-Friendly. » Intelligent» Space Saving

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

MKN-DSP SERIES - THREE PHASE

Appendix T: BATTERY REQUIREMENTS FOR INTERCONNECTION TO PG&E SYSTEM

Series 120/120VAC Universal Tower/Rack Mount

Duo Battery Charge Controller

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

premium charge Innovative charging technology Made in Germany

On-line, Single Phase, Double Conversion UPS

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

System Background and Operation

Advanced Alternative Energy Solutions HSS. Hybrid Storage Solution HYBRID ALTERNATIVE ENERGY STORAGE COMBINED WITH INTELLIGENT CONTROLS

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

ABB Drive Services Your choice, your future

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

Transcription:

Protecting your power supply SENTINEL BATTERY MONITORING

Helios Power Solutions If you re operating mission critical systems and relying on the protection of a UPS and battery bank, then it has to make sense to have battery monitoring. It s about peace of mind knowing that the batteries are healthy and being constantly monitored. Knowing that everything has been done, that can be done, to protect your enterprise from the consequences of a power failure. All batteries will fail, it is just a matter of time. It only takes the failure of one battery to compromise the entire battery string. It is often assumed that batteries are meticulously maintained, but this is rarely so. Many batteries are not inspected or maintained beyond an annual UPS service visit. Unknown and undetected battery failures become apparent right at the time when you need the batteries the most during a mains failure. UPS systems provide only rudimentary battery monitoring. The UPS cannot identify faults within individual batteries, nor detect an imbalance in the performance of multiple strings. To ensure the integrity of the battery system, it is necessary to detect failing blocks before they affect the performance of the entire system. The effectiveness of a battery monitoring system is proportional to the number of points that are monitored and the frequency that this occurs. With regular monitoring comes the accumulation of data, the ability to report and spot trends, and the ability to take timely remedial action. Helios Power Solutions when and where it matters the most PowerShield is trusted throughout the world to help protect the power supply of data centres, banks, hospitals, telecommunications operators, and a wide range of major commercial and industrial enterprises. The Helios System takes a modular approach to battery monitoring. This means that by selecting from a range of options, the system can be tailored to meet your specific requirements. VRLA or wet cells, lead acid or Ni-Cd - Helios has a solution for your battery. 80% of UPS failures are due to undetected battery problems Helios provides the most advanced and most cost-effective tool for monitoring and managing stand-by battery banks. Helios continuous data sampling, reporting and battery management capability delivers reduced costs, gives peace of mind, and most importantly - ensures that you have batteries that perform when needed.

Understanding your batteries Individual Battery Voltage Correct float voltage is critical for battery life. Incorrect charge voltages may result in loss of capacity, accelerated grid corrosion, excessive gassing and premature end of life. Voltage also identifies catastrophic failures, such as short circuit cells, and gives true visibility of performance under discharge. Ambient Temperature A battery s life-span is normally specified at 20 or 25 degrees centigrade. Temperatures outside of the specified range can significantly affect the battery s corrosion rate, and therefore the life of the battery. An 8-10deg temperature increase can decrease battery life by 50%. String Current String current monitoring measures the energy delivered or accepted by each battery string. A UPS will only measure total current and cannot detect imbalances between strings. An imbalance highlights potential problems within a battery string. String current measurement also allows detection of incorrect battery charging and any significant earth leakage faults. String Voltage Tracking the string voltage confirms the charger is on and performing correctly. Individual Battery Impedance (Ohmic Value) The impedance of a battery will increase with age. High impedance results in a battery that cannot supply the required current its key task. By trending impedance you can accurately determine end-of-life. High impedance readings also highlight poor connections and open circuit batteries before failure. Batteries can fail in a very short period of time (less than a week) so measuring impedance daily allows you to detect faulty batteries - without the need to discharge them. Individual Battery Temperature Measuring the temperature of each battery allows the early detection of thermal runaway. It pinpoints localised environmental problems through poor HVAC, and can also highlight poor connections and excessive charger ripple. A common failure mode for Ni-Cds is separator failure which can be detected with temperature. PowerShield System Option 1 Option 2 Option 3 Option 4 Individual Voltage Ambient Temperature String Current String Voltage Impedance Battery Temperature Get the information you need to confirm your batteries are operating within IEEE/IEC guidelines.

The financial benefits By definition, wherever there is a bank of batteries, there is a mission-critical environment being protected. It follows that if the batteries are unable to perform when they are needed, the consequences and costs are going to be serious. Power failures happen all too often, and at a time like that, the investment in the UPS, battery bank, and battery monitoring system needs no further financial justification. However, even in day-to-day operation, PowerShield battery monitoring provides a strong return. The following cost savings are worth considering: Fewer batteries to purchase - through extending the useful life of those that you have. Reduced manpower through automation & reduced number of discharge tests. Reduced call-out charges through effective preventive maintenance. Planned battery purchasing through avoiding emergency replacements. Reduced travel and time through remotely accessing status data. Successful warranty claims through having documentary evidence. Reduced Insurance premiums Permanent monitoring not only offers increased measurement frequency and consistency, it allows this do be done with greater safety and security. Keep personnel out of hazardous battery rooms and away from sensitive plant & operations. Simplify your heath & safety planning and focus on your core operations. The more critical your environment - the more necessary PowerShield becomes. Helios gives us the confidence to get on with running the business with the peace of mind that should there be a power outage, our battery back up is in A1 condition Television New Zealand Helios increased safety through optical isolation became very important to our system. The reduction in maintenance cost was an added advantage. Telecom It is easy to install, neat in appearance, straight forward to commission and the software is user friendly. We use the system wherever possible to obtain complete and accurate battery data

Helios battery monitoring features Data presentation is the key for efficient management 24/7 alarm notification. Automatic capture and recording of data during float, charge, discharge & idle. Compatible with float & intermittent charging. Rapid voltage sampling - all batteries simultaneously every 4 seconds. Built in intelligence - battery state recognition & self calibration for reliable impedance. User defined alarm limits. On-board memory. Sealed, vented, Ni-Cd batteries. Flexible to suit battery model & application. Designed to allow IEEE/IEC best practice. Remote reporting service available. A single Helios system can monitor up to 1,280 batteries. Connecting multiple systems via Helios Link battery management software gives visibility to an unlimited number of batteries from a single desk. Offers: WAN/LAN integration for remote monitoring via Link software. RS 232 connection for local battery service and diagnosis. SNMP or Modbus interface to Building Management Systems. Dry contacts for alarm output. Ensure that you can see and understand what is happening in your battery room. Link battery management software Proactive management tool Permanent connection to multiple sites Real time battery status Alarm & activity log with on-screen pop-ups and email alerts Live discharge display Automated data management with RDBMS storage Battery history database for life trending Point & click report generation