Critical Battery Monitoring, Testing, & Charging Solutions

Size: px
Start display at page:

Download "Critical Battery Monitoring, Testing, & Charging Solutions"

Transcription

1 Keeping an Eye on Your Critical Power! Critical Battery Monitoring, Testing, & Charging Solutions 2016 Product Catalog ISO 9001:2008 CERTIFIED Utilities Data Centers Industrial Telecom Motive Power Eagle Eye Power Solutions, LLC

2 The leader in Critical Battery Monitoring, Testing & Charging Solutions THE EAGLE EYE ADVANTAGE Eagle Eye Power Solutions (EEPS) mission is to lead the industry in battery testing education, training, products, and support. Being the industry leader requires outstanding products, support services and overall value, so that every customer is 100% satisfied with their EEPS experience. We work with a variety of industries including utility, telecom, data centers, industrial, government & defense, motive power & other applications where backup battery performance is critical. Products Held to the Highest Standards Our world-class manufacturing and testing facilities have been producing quality products since Eagle Eye is ISO:9001 certified - our products are held to the highest standards in the industry. Ongoing Customer Support & Free Training Our response time and continued support to our customers are always a main priority for any representative at Eagle Eye. We offer unbeatable support & offer free training with every purchase. Industry Experts - Meet Compliance Needs Eagle Eye understands the need for meeting common industry regulations and standards - including NERC PRC-005-2, IEEE , IEEE , IEEE , IFC 608.3, and more! Focused On Long-Term, Mutually Beneficial Relationships Building lifetime customers is a priority for Eagle Eye. We encourage and value customer feedback regarding product & support improvements, and to better fit any specific needs & requirements.

3 Table of Contents Battery Training Training Eagle Eye University Training Courses 4-5 Battery Monitoring Systems BQMS Modular Battery Monitoring System 6-7 ipqms Battery Monitoring up to (488) Jars/Cells 8-9 BDS-Pro Battery Monitoring up to (24) Jars/Cells BMS-icom Battery Monitoring up to (4) 12V Jars/Cells 12 VGM-Series Battery Voltage & Ground Fault Monitoring 13 ELM-Series Battery Electrolyte Level Monitoring BTM-Series Battery Temperature / Thermal Runaway Monitoring 16 IEEE / NERC Solutions NERC Compliance Solutions Battery Monitoring & Portable Testing IEEE Compliance Solutions Battery Monitoring & Portable Testing Portable & Inline Testers IBEX-Series Battery Voltage & Internal Resistance Testers SG-Ultra Max Digital Hydrometer / Density Meter 26 SG-Ultra Digital Hydrometer / Density Meter 27 SG-1000 Digital Specific Gravity Tester 28 DLV-Max Digital Voltmeter & Specific Gravity Test Kit 29 SG-100M In-tank Liquid Density Hydrometer 30 DM-Series Inline Density Meters 31 GFL-1000 Ground Fault Locator 32 TIC-Series Thermal Imaging Cameras 33 AC & DC Load Banks SLB-Series SMART Constant Current DC Load Banks LB-Series Constant Current DC Load Banks 37 LB-Series AC Load Banks 38 Battery Regenerators LB-1000 Battery Discharger / Charger / Activator 39 BR-200 6, 8, 12V Battery Regenerator 40 BR V Universal Battery Regenerator & Charger 41 Battery Chargers Energenius IQ Microprocessor Battery Charger and Monitoring System 42 AT 10.1/AT30 Microprocessor Controlled Float Battery Chargers 43 MP-1000 Modular High Frequency Motive Power Battery Charger 44 GC-1000 Golf Cart Battery Charger 45 Gas Detection GD-Series Gas Detectors 46 VS-Series Ventilation Systems 47

4 MILWAUKEE eeu EAGLE EYE UNIVERSITY WISCONSIN Eagle Eye University Increasing Critical Power Reliability with Hands-on Education 30+ Years of Battery Knowledge EEU s instructors are industry specialists with countless years of instructional and hands-on field experience. Attendees will leave with in-depth real-world knowledge to fulfill their responsibilities. Comprehensive Training Programs In addition to EEU s standard course offering, we have the ability to customize any education program regarding battery reliability - including courses focusing on compliance with common industry standards such as IEEE, NERC, IBC & more. Attendees Across All Industries Industrial engineers, operation managers, power system technicians, facility managers, and emergency & disaster preparedness managers are all positions that will leave with a greater understanding of battery management & reliability - ensuring the safety of their workplaces. Introduction to Battery Management for Standby Power Systems 2-Day Course: This Course will provide an introduction on why and how to implement a battery management program. The program will cover all aspects of battery management from safety, battery types and applications, recommended practices per industry standards and guidelines, testing, and condition analysis. The course is intended for all personnel who have responsibility for the operation and management of batteries in a standby power environment. DC Power Systems 2-Day Course: This course covers the theory and design of the DC power systems that are typically used in standby applications. The attendees will receive instruction on the operating characteristics of the individual system components and their application within specific market areas - including telecommunications and power utilities. The basics of system design from system configuration/sizing through installation and commissioning, will also be covered. This course is intended for any personnel involved in the Specification, Procurement and Installation of DC power systems. Battery Data Analysis 2-Day Course: This course provides an in-depth look at the measurable battery parameters and their value in proving information with respect to a battery s reliability. Attendees will receive instruction in the use of both limit and trend analysis for both operation and discharge data. This course is intended for supervisory personnel with responsibility for the analysis of the collected battery data plus the determination of any remedial action required. Battery knowledge to the level covered in Battery 101 should be a prerequisite for this course. Battery Day Course: This course will provide the attendee with a comprehensive overview of the battery types and how they are used in Standby Power applications. The course is a basic introduction to the theory and management of batteries and is intended for personnel who have responsibility for the operation and maintenance of the batteries in Standby Power Systems. PRC Battery Operation & Maintenance Compliance Custom 1 or 2-Day Course: This course is designed to help Utility Companies ensure that their operation and maintenance procedures are in compliance with the battery maintenance requirements of NERC PRC The course will include a review of battery maintenance fundamentals, inspection methods both manual and automated, interpretation of the data collected and the required record keeping. This course is intended for all personnel with responsibility for the implementation and operation of a compliant battery monitoring and testing program. 4 5

5 BQMS Battery Monitoring System Common Applications: Data Centers, UPS Systems, Power Utilities & Distribution Product Description The BQMS Battery Monitoring System is designed to measure the aging status of up to 480 cells/units by measuring and recording: string voltage, string current, cell/unit voltage, internal resistance, cell/unit temperature and ambient temperature. The BQMS is intended for use on vented lead acid (VLA), valve regulated lead acid (VRLA), and nickel-cadmium (Ni-Cad) battery systems. Installation of the BQMS is non-intrusive and can be completed while the battery system is online. Battery Monitoring Systems BMS-SERIES Communication Control Unit (CCU) Product Advantages 24/7/365 Battery Monitoring. Comprehensive Battery Management Software. Installation while systems are online. Meets IEEE and NERC standard recommendations for battery monitoring. Patented ripple-removing algorithm to filter out noise from measurements. Injects minimal current for measurement. Simple to install with custom, pre-assembled installation materials. Add-On Products Include: ELM-Series for electrolyte level monitoring, GFM-100 for ground fault monitoring, and the HGD-2000 for hydrogen gas detection. See the EE-NERC-Series page for more information. Standard communication includes Eagle Eye s Centroid 2 Battery Management Software for recording and trending measured parameters. Centroid 2 can be installed on a private network on multiple PC s. Networked systems can utilize SMS/ alerts during alarm conditions. Alternatively, the BQMS can be configured for Modbus output to an existing building management system or SCADA. All BQMS systems have the option to include up to (13) dry contact relays for additional external alarming. BQMS Installation on 125VDC Utility Battery System Battery Management Software Displays and records string voltage, string current, cell/unit voltage, internal resistance, temperature. Trending analysis of measured parameters on a string and cell/unit level with colored, easy to read graphs. PDF and Excel reporting. Detailed log of alarm outbreak history and SMS alerts Automatically record, save, & playback discharge & recharge events. Centroid 2 Battery Management Software 6 Tel: Fax: info@eepowersolutions.com V1.3

6 BQMS System Composition Typical BMQS systems are configured with the following main components: CCU (Communication Control Unit) A single CCU per system processes all measurement data and handles TCP/IP communication and alarming via dry contacts. Modules Connected in daisy chain and mounted on the battery rack. Wired directly to the battery connections for measurement of cell/unit parameters. BMS/SCADA Modbus TCP/IP TCP/IP Server Client Connection Clamps Physical connection to battery system. Installs to battery inter-cell cables or busbars. Server & Client PC Main computer which interfaces with the CCU. Runs Centroid Snet Server application. Client PC s installed on same network for additional users. Battery Capacity: 5 6,000 Ah Nominal Cell/Unit Voltage: 1.2V, 2V, 4V, 6V, 8V, 12V Measurement Range: String Voltage: VDC String Current: ±10,000 Temperature: 0 80 C ( F) String Voltage/Current: ±0.5% / ±1% Cell/Unit Temperature: ±2% Accuracy: Cell/Unit Internal Resistance: ±2% Cell/Unit Voltage: ±1% DC Voltage/Current: 0.1 V / 0.1 A Cell Voltage: 0.01 V Resolution: Internal Resistance: Ω Temperature: 0.1 Test Speed / Test Load: 30 seconds per bank at less than 2 A per cell Measuring Interval: Adjustable from 10 min to 24 hours (cell/unit readings) Data Transfer: TCP/IP to proprietary software, Modbus Alarming Up to (13) Form C outputs and (8) inputs Operating Environment: Temperature: 0 65 C ( F), RH: Under 80% Input: VDC / VAC Power Requirements: Consumption: CCU: 10W, Modules: 3W Dimensions: Clamp Connections to Battery Bank CCU: 210 x 76 x 200 mm (8.25 x 3 x 7.9 in) Module: 114 x 70 x 39 mm (4.5 x 2.75 x 1.5 in) SMS/ Applications UPS Systems Power Utilities and Distribution Telecom/Communications Data Centers Oil, Gas & Fuel Mining Government/Defense Transportation Operations Battery Suppliers and Manufacturers System Includes Centroid Viewer Battery Management Software BQMS CCU Measuring Modules C-Clamps for inter-cell busbar connections O-Clamps for inter-cell cable connections Cabling for all measurement connections CT for string current measurement Optional: Spare parts kit Battery Monitoring Systems BMS-SERIES 1 BQMS Battery Monitoring Solutions: Up to 480 Cells/Units Tel: Fax: info@eepowersolutions.com V1.3 7

7 ipqms Battery Monitoring System Common Applications: Power Utilities & Distribution, UPS Systems, Telecom/Communications Product Description The ipqms Battery Monitoring System is designed to measure the aging status of up to 448 cells/units by measuring and recording: string voltage, string current, cell/unit voltage, internal resistance, and temperature. The ipqms is intended for use on vented lead acid (VLA), valve regulated lead acid (VRLA), and nickel-cadmium (Ni-Cad) battery systems. Installation of the ipqms is nonintrusive and can be completed while the battery system is online. Battery Monitoring Systems BMS-SERIES Main Processing Unit (MPU) Product Advantages 24/7/365 Battery Monitoring. Comprehensive Battery Management Software. Installation while systems are online. Meets IEEE and NERC standard recommendations for battery monitoring. Patented ripple-removing algorithm to filter out noise from measurements. Injects minimal current for measurement. Simple to install with custom, preassembled installation materials. Can be powered by AC or DC. Standard communication includes Eagle Eye s Centroid 2 Battery Management Software for recording and trending measured parameters. Centroid 2 can be installed on a private network on multiple PC s. Networked systems can utilize SMS/ alerts during alarm conditions. Alternatively, the ipqms can be configured for Modbus output to an existing building management system or SCADA. ipqms Installation on 125VDC Utility Battery System Battery Management Software Displays and records string voltage, string current, cell/unit voltage, internal resistance, temperature. Trending analysis of measured parameters on a string and cell/ unit level with colored, easy to read graphs. PDF and Excel reporting. Detailed log of alarm outbreak history and SMS alerts Automatically record, save, & playback discharge & recharge events. Centroid 2 Battery Management Software 8 Tel: Fax: info@eepowersolutions.com V1.2

8 ipqms System Composition Typical ipqms systems are configured with the following main components: MPU (Main Processing Unit) A single MPU per system processes all measurement data and handles communication. Allows on-site viewing of data with LCD. Modbus TCP/IP TCP/IP RU (Relaying Unit) Up to 7 RUs per system wire directly to clamps fitted to the battery inter-cell connections. Performs measurement and relays data back to the MPU. BMS/SCADA Server Client Connection Clamps Physical connection to battery system. Installs to battery inter-cell cables or busbars. Server & Client PC Main computer which interfaces with the MPU. Runs Centroid Snet Server application. Client PC s installed on same network for additional users. Clamp Connections to Battery Bank Battery Capacity: 5 6,000 Ah Measurement Range: Nominal Cell/Unit Voltage: 1.2V, 2V, 4V, 6V, 8V, 12V String Voltage: VDC String Current: ±999.9 A String Voltage/Current: ±0.5% / ±1% Accuracy: Cell/Unit Temperature: ±2% Cell/Unit Internal Resistance: ±2% Cell/Unit Voltage: ±1% DC Voltage/Current: 0.1 V / 0.1 A Resolution: Cell Voltage: 0.01 V Internal Resistance: Ω Temperature: 0.1 Test Speed / Test Load: 4 seconds per cell at less than 2 A per cell Measuring Interval: Adjustable from 10 min to 24 hours (cell/unit readings) Data Transfer: TCP/IP to proprietary software, Modbus Internal Storage: Approximately 1 month backup Operating Environment: Temperature: 0 65 C ( F), RH: Under 80% Power Requirements: Input: VDC / VAC Consumption: 15 W Dimensions: MPU: 290 x 280 x 90 mm (11.4 x 11 x 3.5 in) RU: 310 x 178 x 85 mm (12.2 x 5.9 x 3.3 in) SMS/ Applications UPS Systems Power Utilities and Distribution Financial Institutions Telecom/Communications Oil, Gas & Fuel Mining Government/Defense Transportation Operations Battery Suppliers and Manufacturers Medical/Biotechnology Generators System Includes ipqms hardware Centroid 2 battery management software All installation materials USB drive with software and support literature Optional: Spare parts kit Battery Monitoring Systems BMS-SERIES 1 ipqms Battery Monitoring Solutions: Up to 448 Cells/Units Tel: Fax: info@eepowersolutions.com V1.2 9

9 BDS-Pro Battery Monitoring System Common Applications: Power Utilities & Distribution, UPS Systems, Telecom/Communications Product Description The BDS-Pro Battery Monitoring System is designed to measure the aging status of up to 24 cells/units by measuring and recording: string voltage, string current, cell/unit voltage, internal resistance, and temperature. The BDS-Pro is intended for use on vented lead acid, valve regulated lead acid, and nickel-cadmium battery systems. The included Centroid 2 Battery Management Software records measured data for comprehensive trending analysis. The BDS-Pro Battery Monitoring Solution is an accurate, user-friendly and economic solution for monitoring systems using up to 24 cells/units. Battery Monitoring Systems BMS-SERIES Main Processing Unit (MPU) Reduce maintenance costs, improve up-time and manage your battery assets effectively by using the BDS- Pro battery monitoring solution for your system. Protect yourself from battery failure - one of the leading causes of facility downtime with battery monitoring. Product Advantages 24/7/365 Battery Monitoring. Comprehensive Battery Management Software. Installation while systems are online. Meets IEEE and NERC standard recommendations for battery monitoring. Patented ripple-removing algorithm to filter out noise from measurements. Injects minimal current for measurement. Simple to install with custom, pre-assembled installation materials. Can be powered by AC or DC. Installation to 48V Switchyard Battery Battery Management Software Displays and records string voltage, string current, cell/unit voltage, internal resistance, temperature. Trending analysis of measured parameters on a string and cell/ unit level with colored, easy to read graphs. PDF and Excel reporting. Detailed log of alarm outbreak history and SMS alerts Automatically record, save, & playback discharge & recharge events. Centroid 2 Battery Management Software 10 Tel: Fax: info@eepowersolutions.com V1.2

10 BDS-Pro System Composition Typical BDS-Pro systems are configured with the following main components: MPU (Main Processing Unit) A single MPU per system processes all measurement data and handles communication. Connection Clamps Physical connection to battery system. Installs to battery intercell cables or busbars. Server PC Main computer which interfaces with the MPU. Runs Centroid Snet Server application. BMS/SCADA Modbus TCP/IP TCP/IP Server Client Client PC Additional computers on the network which communicate with the Server PC. Runs Centroid Viewer application. Clamp Connections to Battery Bank Battery Capacity: 5 6,000 Ah Measurement Range: Nominal Cell/Unit Voltage: 1.2V, 2V, 4V, 6V, 8V, 12V String Voltage: VDC String Current: ±999.9 A String Voltage/Current: ±0.5% / ±1% Accuracy: Cell/Unit Temperature: ±2% Cell/Unit Internal Resistance: ±2% Cell/Unit Voltage: ±1% DC Voltage/Current: 0.1 V / 0.1 A Resolution: Cell Voltage: 0.01 V Internal Resistance: Ω Temperature: 0.1 Test Speed / Test Load: 4 seconds per cell at less than 2 A per cell Measuring Interval: Adjustable from 10 min to 24 hours (cell/unit readings) Data Transfer: TCP/IP to proprietary software, Modbus Internal Storage: Approximately 2 weeks backup Operating Environment: Temperature: 0 65 C ( F), RH: Under 80% Power Requirements: Input: VDC / VAC Consumption: 20 W Dimensions: MPU: 195 x 270 x 55 mm (7.7 x 10.6 x 2.2 in) SMS/ Applications Telecom/Communications Power Utilities and Distribution Transportation Operations Oil, Gas & Fuel Generators UPS Systems System Includes BDS-Pro hardware Centroid 2 battery management software All installation materials Fitted CT clamp USB drive with software and support literature Optional: Spare parts kit Battery Monitoring Systems BMS-SERIES 1 BDS-Pro Battery Monitoring Solutions: Up to 24 Cells/Units Tel: Fax: info@eepowersolutions.com V1.2 11

11 BMS-icom Battery Monitoring System Common Applications: Generators, Power Utilities & Distribution Product Description The BMS-icom Battery Monitoring System is designed to measure the aging status of up to (4) 12V units by measuring and recording: string voltage, string current, unit voltage, internal resistance, and temperature. The included Centroid 2 Battery Management Software displays and records measured data for comprehensive trending analysis. The BMS-icom is accurate, repeatable, user-friendly, and cost effective solution for monitoring 48VDC systems using (4) 12V batteries. Battery Monitoring Systems BMS-SERIES BMS-icom Product Advantages 24/7/365 Battery Monitoring Installation and maintenance can be done while battery systems are online Meets IEEE and NERC standard recommendations for battery monitoring Utilizes a patented ripple-removing algorithm Injects minimal current for measurement Simple to install with custom, pre-assembled materials Designed for 48V systems (12V cells) Alerts in real-time during outbreak Measurement Range: Accuracy: Test Speed / Test Load: Measuring Interval: Operating Environment: Power Requirements: Dimensions / Weight: Reduce maintenance costs, improve up-time and manage your battery assets effectively by using the BMS-icom battery monitoring solution for your 48V system. Real-time battery monitoring also reduces maintenance and replacement costs by maximizing your battery life. Battery Capacity: 5 6,000 Ah Nominal Cell/Unit Voltage: 12V String Voltage: VDC String Current: ±999.9 A String Voltage / Current: ±0.5% / ±1% Temperature: ±2% Internal Resistance: ±2% Cell/Unit Voltage: ±1% 4 seconds per cell / less than 2 A per cell/unit Adjustable from 10 min to 24 hours (voltage & resistance) Temperature: 0 65 C ( F) Relative Humidity: Under 80% Input: VDC (from connected batteries) Consumption: 7 W 140 x 121 x 44.5 mm (5.5 x 4.8 x 1.8 in) BMS-icom Installation System Includes BMS-icom hardware Centroid 2 battery management software All installation materials Fitted CT clamp USB drive with software and support literature Optional: Spare parts kit 1 BMS-icom Battery Monitoring Solutions: Up to 4 (12V) Jars/Cells 12 Tel: Fax: info@eepowersolutions.com V1.2

12 VGM-Series Voltage & Ground Fault Monitors VGM-Series Monitor Features Color touchscreen simple interface Ethernet connectivity to web interface, (4) Form C Contacts High reliability & durability Simple installation Includes mounting kit for DIN rail or wall mount Monitors 24V, 48V, 125V, & 250V batteries Alarm Contacts VGM (1) Form C each for over voltage, under voltage, positive ground, & negative ground VM (2) Form C each for over & under voltage GFM (2) Form C each for positive & negative ground Measurement Range: Fault Resistance Limit Set: Output Contacts: Contact Rating: Maximum Switching Power: Power requirements: Noise Immunity: Time Delay to Alarm: Operating Environment: Dimensions / Weight: Product Overview The Eagle Eye VGM-Series is an inexpensive and simple solution for monitoring battery string voltage and battery ground faults. For monitoring of both string voltage and ground faults, the VGM-100 is available. The VM-100 is available for only monitoring string voltage, and the GFM-100 is available for monitoring of ground faults. All models read battery bus status, detect out-of-limit conditions, and provide alarm indications per user settings. The monitor s status, U.V. and O.V. trip values, ground fault, time delay, and IP address settings are accessible on the color touchscreen. Output contacts corresponding to alarm conditions are available on each model. The VGM-Series is extremely durable and easily installed as a wall, panel, or DIN rail unit. VGM-100/VM-100: 18-32, 38-60, , VDC GFM-100: 20-28, 38-56, VDC kohm (4) Form C 125 VAC/VDC: 0.5A 30VDC: 2A 60 W Powered by connected battery DC voltage IEEE/ANSI Standard C 37.90a-1989 compliance Adjustable seconds Temp: 0 55 C ( F), Humidity: 0 95% RH 147 x 91 x 45 mm (5.77 x 3.56 x 1.77 in) / 284 g (10 oz) Web-Interface for Monitoring Kit Includes VGM-Series monitor DIN rail mounting clip Backplate for wall mounting Voltage & Ground Fault Monitors VGM-SERIES 1 VGM-100-XXX (1) Voltage & Ground Fault Monitor, available for 24V, 48V, 125V, or 250V 2 VM-100-XXX Voltage Monitor, available for 24V, 48V, 125V, or 250V 3 GFM-100-XXX Ground Fault Monitor, available for 24V, 48V, 125V, or 250V 1) Determine part number for required voltage, Ex. VGM-100-XXX would be VGM for 125V applications. Tel: Fax: info@eepowersolutions.com V1.0 13

13 ELM-Series Electrolyte Level Monitor Product Description The ELM-Series is a reliable dual sensor system that monitors the electrolyte level and temperature of individual flooded batteries. Utilizing low cost, easy to install sensors, the system will alarm on low electrolyte level or higher than normal temperature. The sensors are simply and securely attached, either directly to the cell/unit, or via an optional (included) clip which allows the sensor to be removed and re-used if the cell/unit should require replacement. Electrolyte Level Monitoring Systems ELM-SERIES ELM Monitor Product Advantages Low cost monitor for electrolyte level & cell/unit temperature monitoring Auto calibrating sensors adjust to battery in seconds Alarm contacts for external alarming LED lights on monitor and sensors for visual alarming on-site Fast and easy installation, all cabling cut to length based on simple site survey Applicable to any flooded battery system regardless of voltage & amp-hour Utilized commonly available cabling between sensors for easy sourcing of additional materials In the condition of a low electrolyte or temperature alarm, the sensors communicate to the system monitor and the system monitor activates a changeover relay output while simultaneously activating the appropriate alarm LED lights. In the event that four or more cells/units fall to an alarm level, the monitor will trigger a group alarm in addition to the single alarm. The alarm contacts are volt-free and can be made as make-on-alarm or fail-safe mode (giving warning of a supply failure) and may be linked in to any facilities management or alarm system for remote monitoring. Sensor Installation Installation of the ELM sensors is simple and fast. Sensors are daisy chained together via provided, pre-cut ribbon cable. All required materials for installation are provided and do not require modification. Each ELM sensor is installed to front of the battery case via a peel off adhesive. Small marks on the sensor allow it to be easily lined up with the minimum line on the cell/unit for accurate level detection. No marking of the battery jar is required during installation. ELM Sensor with Mounting Cradle 14 Tel: Fax: info@eepowersolutions.com V1.1

14 Sensor LED Indicators Each sensor has (3) LED lights. A green LED will illuminate when there is no fault. Separate red LEDs will illuminate in the event of level or temperature alarm. The LED s provide quick visual cues to determine the condition of specific cells/units in a string. Battery Types: Temperature Alarm Activation: Level Accuracy: Input Voltage: Output Relays Dimensions: (L x W x D) Sensors Installed to Level Line on Flooded Cells Compatible with all transparent flooded battery types 35 C (95 F), ± 2 C (3.5 F) 49 C (120 F), ± 2 C (3.5 F) 63 C (145 F), ± 2 C (3.5 F) Optional: No temperature alarm ± 2mm (± 0.08 ) above or below line label 12V DC ± 10%, 1 Amp SPDT volt-free contact relays for: 1+ low electrolyte level detection 4+ low electrolyte level detection 1+ high temperature detection 4+ high temperature detection Monitor: 176 x 80 x 51 mm (6.9 x 1.6 x 3 in) Sensor: 54 x 35 x 15 mm (2.2 x 1.4 x 0.8 in) Sensor Cradle: 65 x 52 x 14 mm (2.6 x 2.1 x 0.6 in) Cables: 1.25mm pitch at nominal length of 305 mm (12 in) System Includes Monitor Sensors Sensor Mounting Cradles Pre-Cut Ribbon Cable 12V AC Wall Adapter Support Literature Electrolyte Level Monitoring Systems ELM-SERIES No. Model # (1) Description 1 ELM-4C Electrolyte Level Monitoring Solution: Up to 4 Cells/Units 2 ELM-6C Electrolyte Level Monitoring Solution: Up to 6 Cells/Units 3 ELM-8C Electrolyte Level Monitoring Solution: Up to 8 Cells/Units 4 ELM-12C Electrolyte Level Monitoring Solution: Up to 12 Cells/Units 5 ELM-24C Electrolyte Level Monitoring Solution: Up to 24 Cells/Units 6 ELM-60C Electrolyte Level Monitoring Solution: Up to 60 Cells/Units 7 ELM-120C Electrolyte Level Monitoring Solution: Up to 120 Cells/Units 8 ELM-240C Electrolyte Level Monitoring Solution: Up to 240 Cells/Units 1) Common configurations shown, custom configurations available. Tel: Fax: info@eepowersolutions.com V1.1 15

15 BTM-Series Battery Temperature/Thermal Runaway Monitor Product Overview The BTM-Series is a dependable low-cost scalable solution to protecting your batteries against over-temperature and thermal runaway conditions. Individual sensors are quickly and securely attached to each battery jar and connected in series from the main unit. Each thermal sensor is sealed to IP68 (water, gas and dust proof) and the provided special gel-filled connectors are also sealed against acid ingress, dust, and gases. Battery Temperature Monitors BTM-SERIES BTM-Series Monitor & Sensor Features Low cost monitor for thermal runaway detection Monitors individual unit temperatures for thermal runaway conditions Ensures compliance with US IFC608.3 Simple fail-safe change-over relay alarm interfaces (2) Bright LEDs pinpoint individual overtemperature jars Fast one-wire acid and gas tight IDC connections Sensor circuit break detection Alarm on power supply failure (fail-safe) The alarm relays are fail-safe, meaning the user will always get an indication of supply failure. Several batteries in the vicinity of each other may be connected in series to the same monitor. In the event of one or more jars exceeding critical temperature, or a break in the sensor circuit, the monitor warning relay activates and the warning LED on the monitor is illuminated. Also at the same time an LED flashes on the sensor attached to the over-temperature battery jar, indicating the source of the fault. Should more than 4 jars exceed critical temperature, the system critical alarm relay activates Typical Connection of Sensors from Main Monitor Alarm Range: Reinstatement Temp: Input Voltage: DC 12V, 0.1A Output Relays Dimensions: (L x W x D) Compliance: Activation at 35 C (95 F), ± 3 C (5 F) 2 C (3.5 F) below activation temperature (2) SPDT volt-free contact relays Monitor: 84 x 40 x 77 mm (3.3 x 1.6 x 3 in) Sensor: 38 x 20 x 10 mm (1.5 x 0.8 x 0.4 in) Cables: 300 mm (11.8 in) UL, CE LED Indicators for: 1+ Jars critical temperature 4+ Jars critical temperature Power failure Sensor circuit break 1 BTM-Series (1) Battery Temperature Monitor includes (1) monitor and number of sensors per jars / cells 1) Model number varies per number of jars (Ex. BTM-60C for system with 60 jars) 16 Tel: Fax: info@eepowersolutions.com V1.2

16 BATTERY MONITORING NERC & IEEE Battery Monitoring And Testing Solutions Guide Meet Industry Guidelines & IEEE Requirements NERC 17

17 Eagle Eye NERC Battery Monitoring Solution Compliance Solutions NERC BATTERY MONITORING SOLUTION Eagle Eye Power Solutions provides battery monitoring solutions to power utilities worldwide. NERC (North American Electric Reliability Corporation) is a not-for-profit regulatory authority that ensures the reliability of the BES by enforcing reliability standards. NERC PRC-005 is the standard for Protection Systems Maintenance and Testing. PRC requires utilities to document and implement programs for the maintenance of all protection systems affecting the reliability of the Bulk Electric System (BES). NERC PRC Table 1-4(f) Exclusions for Protection System Station DC Supply Monitoring Devices and Systems *Maximum Maintenance Interval: No periodic maintenance specified NERC Requirement Attributes / Eagle Eye Solution Any station dc supply with high and low voltage monitoring and alarming of the battery charger voltage to detect charger overvoltage and charger failure. BQMS: Monitors String Voltage Any battery based station DC supply with electrolyte level monitoring and alarming in every cell. ELM-Series: Monitors Electrolyte Level Any station DC supply with unintentional DC ground monitoring and alarming. GFM-100: Monitors for DC Grounds Any station DC supply with charger float voltage monitoring and alarming to ensure correct float voltage is being applied on the station DC supply. BQMS: Monitors String Voltage Any battery based station DC supply with monitoring and alarming of battery string continuity. BQMS: Monitors String/Cell Voltage & Cell Internal/ Connection Resistance Any battery based station DC supply with monitoring and alarming of the intercell and/or terminal connection detail resistance of the entire battery. BQMS: Monitors Cell Internal & Connection Resistance Any Valve Regulated Lead-Acid (VRLA) or Vented Lead-Acid (VLA) station battery with internal ohmic value or float current monitoring and alarming, and evaluating present values relative to baseline internal ohmic values for every cell/unit. BQMS: Monitors DC Current, & Internal Ohmic Values for all Battery Types Any Valve Regulated Lead-Acid (VRLA) or Vented Lead-Acid (VLA) station battery with monitoring and alarming of each cell/unit internal ohmic value. BQMS: Monitors Ohmic Value of Each Cell Maintenance Activities No periodic verification of station dc supply voltage is required. No periodic inspection of the electrolyte level for each cell is required. No periodic inspection of unintentional DC grounds is required. No periodic verification of float voltage of battery charger is required. No periodic verification of the battery continuity is required. No periodic verification of the intercell and terminal connection resistance is required. No periodic evaluation relative to baseline of battery cell/unit measurements indicative of battery performance is required to verify the station battery can perform as manufactured. No periodic inspection of the condition of all individual units by measuring battery cell/unit internal ohmic values of a station VRLA or Vented Lead-Acid (VLA) battery is required Tel: Fax: info@eepowersolutions.com V1.0

18 BQMS Battery Monitoring System The BQMS Battery Monitoring System is a modular system that allows for complete monitoring of a single or multiple battery systems. Parameters monitored include string voltage, DC current, cell voltage, cell / connection resistance, cell temperature, & ambient temperature. The BQMS is designed for use on vented lead acid, valve regulated lead acid, and nickel-cadmium battery systems. The included software package, Centroid 2, allows for remote viewing and data management of all connected Eagle Eye battery monitoring systems. 1 BQMS Modular Battery Monitoring Solution ELM-Series Electrolyte Level Monitor The ELM-Series is a reliable dual sensor system that monitors the electrolyte level and temperature of individual flooded batteries. Utilizing low cost, easy to install sensors, the system will alarm on low electrolyte level or higher than normal temperature. There are LED indicators on the system for visual alarming on site and alarm contacts for external alarming. The alarm contacts can be made as make-on-alarm or fail-safe mode and may be linked in to any facilities management alarm system. 1 ELM-Series (1) Battery Electrolyte Level Monitor (1) monitor and number of sensors per jars / cells 1) Model number varies per number of jars (Ex. ELM-60C for system with 60 jars) GFM-100 Ground Fault Monitor The GFM-100 is a simple solution for monitoring battery ground faults. The unit reads battery bus status, detects out-of-limit conditions, and provides alarm indications per user settings. The monitor s status, under voltage & over voltage trip values, ground fault, time delay, and IP address settings are accessible on the color touchscreen. The GFM-100 Ground Fault Monitor has (2) Form C Alarm Contacts - each for positive and negative ground. Compliance Solutions NERC BATTERY MONITORING SOLUTION 1 GFM-100-XXX Ground Fault Monitor, available for 24V, 48V, 125V, or 250V 1) Determine part number for required voltage, Ex. GFM-100-XXX would be GFM for 125V applications. Tel: Fax: info@eepowersolutions.com V1.0 19

19 Eagle Eye NERC Portable Testing Solutions Eagle Eye understands the importance of testing and maintaining batteries per NERC PRC standards. We offer complete battery testing kits and options that meet and exceed these requirements. The purpose of NERC PRC-005 is to document and implement programs for the maintenance of all protection systems affecting the reliability of the Bulk Electric System (BES) so that these protection systems are kept in working order. Compliance Solutions NERC PORTABLE TESTING SOLUTION NERC PRC Table 1-4(a-e) 4 CALENDAR MONTHS - Maximum Maintenance Interval VLA VRLA NiCd Maintenance Activities EEPS Solution X X X Verify station DC supply voltage IBEX-Series X X Inspect electrolyte level SG-Series X X X Inspect for unintentional grounds GFL-Series 6 CALENDAR MONTHS - Maximum Maintenance Interval VLA VRLA NiCd Maintenance Activities EEPS Solution X Inspect condition of all individual units by measuring battery cell/unit internal ohmic values IBEX-Series 18 CALENDAR MONTHS - Maximum Maintenance Interval VLA VRLA NiCd Maintenance Activities EEPS Solution X X X Verify float voltage of battery charger IBEX-Series X X X Verify battery continuity IBEX-Series X X X Verify battery terminal connection resistance IBEX-Series X X X Verify battery intercell or unit-to-unit connection resistance IBEX-Series X Inspect cell condition of all individual battery cells where cells are visible - or measure battery cell/unit internal ohmic values where the cells are not visible IBEX-Series X Inspect physical condition of battery rack IBEX-Series 6 CALENDAR MONTHS or 3 CALENDAR YEARS - Maximum Maintenance Interval VRLA Only Maintenance Activities EEPS Solution X OR Verify that the station battery can perform as manufactured by evaluating cell/ unit measurements indicative of battery performance (e.g. internal ohmic values or float current) against the station battery baseline (6 calendar months) IBEX-Series OR X Verify that the station battery can perform as manufactured by conducting a performance or modified performance capacity test of the entire battery bank (3 calendar years) SLB-Series 18 CALENDAR MONTHS or 6 CALENDAR YEARS - Maximum Maintenance Interval VLA Only Maintenance Activities EEPS Solution Verify that the station battery can perform as manufactured by evaluating X OR cell/unit measurements indicative of battery performance (e.g. internal ohmic values or float current) against the station battery baseline (18 calendar IBEX-Series months) OR X Verify that the station battery can perform as manufactured by conducting a performance or modified performance capacity test of the entire battery bank SLB-Series (6 calendar years) 6 CALENDAR YEARS - Maximum Maintenance Interval NiCd Only Maintenance Activities EEPS Solution Verify that the station battery can perform as manufactured by conducting a X performance or modified performance capacity test of the entire battery bank (6 calendar years) SLB-Series 20 Tel: Fax: info@eepowersolutions.com V1.0

20 Ultra-Max Plus Kit The Ultra-Max Plus Kit is the premier kit for NERC compliance for Vented Lead Acid (VLA) and Nickel-Cadmium (NiCad) batteries. The Ultra-Max Plus kit has three parts: an IBEX-Ultra Portable Ohmic Battery Tester, SG-Ultra Max Digital Hydrometer, and Exmons Ultra+ Battery Management Software for all-in-one trending and reporting. The Ultra-Max Plus Kit tests internal resistance (internal ohmic values), voltage, inter-cell resistance (connection resistance), temperature, DC current, ripple current, specific gravity (state of charge), and electrolyte temperature. 1 Ultra-Max-Plus Kit IBEX-Ultra Battery Tester, SG-Ultra Max Digital Hydrometer, Exmons Ultra Plus Software GFL-1000 Ground Fault Locator The GFL-1000 Ground Fault Locator is an essential instrument to pinpoint faulty grounding where electrical cables have breakage and loss to the ground. The unit measures current leakage of DC systems with high resistance. The GFL-1000 is designed to fast-detect, track, and locate virtual grounding faults for both offline and online DC systems. The GFL-1000 is used to meet NERC PRC Compliance by inspecting for unintentional grounds for VLA, VRLA and NiCad batteries every four calendar months. 1 GFL-1000 Ground Fault Locator, Range: V, Hz SLB-Series DC Load Banks The SLB-Series Smart DC Load Banks monitor system voltage and cell voltage during discharge. The units are portable, durable, economic and come complete with software for data management. Capacity testing is a requirement every six years under NERC PRC for VLA and NiCad battery banks and every three years for VRLA. Discharge testing is a direct measurement of the battery strings capacity and is essential to learning the true health of critical DC systems. The SLB-Series has over 80+ models to meet any utility battery system configuration. Compliance Solutions NERC PORTABLE TESTING SOLUTION 1 SLB-Series* SMART Constant Current DC Load Bank with Monitoring (12-480V, A) *See catalog page for complete model list *Add DAC after model number for wireless monitoring per cell Tel: Fax: info@eepowersolutions.com V1.0 21

21 Eagle Eye Power Solutions IEEE Solutions Eagle Eye Power Solutions understands the importance of testing and maintaining batteries per IEEE standards. The most common IEEE standards for battery maintenance, testing & monitoring are below: Maintenance Activities IEEE BATTERY TESTING SOLUTIONS IEEE is the recommended practice for maintenance, testing, and replacement of Vented Lead-Acid (VLA) stationary batteries. IEEE is the recommended practice for maintenance, testing, and replacement of Valve-Regulated Lead Acid (VRLA) batteries for stationary applications. IEEE is the recommended practice for maintenance, testing, and replacement of Vented Nickel-Cad mium Batteries (NiCad) for stationary applications. IEEE is for Selection and Use of Battery Monitoring Equipment in Stationary Applications. VLA VRLA NiCd MONTHLY INSPECTIONS Maintenance Activities (Perform ALL items checked for your battery type) EEPS Solution X X Verify float voltage at the battery terminals IBEX-Series X X X Inspect general appearance and cleanliness of battery room or cabinet, racks, and batteries. Inspect for evidence of terminal, connector, and rack corrosion N/A Visual X X X Verify charger output current and voltage IBEX-Series X X Verify battery electrolyte levels ELM-Series / SG-Series X X X Verify ambient temperature and ventilation systems BMS-Series / IBEX-Series X Inspect for any unintentional battery grounds GFL-Series X Record pilot cell s voltage, specific gravity, and electrolyte level SG-Series X X Inspect all installed battery monitoring systems are operational BMS-Series / ELM-Series QUARTERLY INSPECTIONS VLA VRLA NiCd Maintenance Activities (Perform ALL items checked for your battery type in addition to monthly inspections) EEPS Solution X X X Verify voltage of each cell BMS-Series / IBEX-Series X Verify specific gravity of at minimum 10% of battery string cells SG-Series X X X X X Verify temperature of a representative sample of at minimum 10% of the battery cells Verify float voltage & current at the battery terminals Verify cell internal ohmic resistance values BMS-Series / BTM-Series BMS-Series/ IBEX-Series BMS-Series / IBEX-Series YEARLY INSPECTIONS VLA VRLA NiCd Maintenance Activities (Must perform ALL items checked for your battery type in addition to monthly and quarterly inspections) EEPS Solution X Verify specific gravity of all battery cells SG-Series X Verify AC ripple current IBEX-Series X X Record each cell temperature IBEX-Series X X X Verify cell-to-cell terminal connection resistance BMS-Series/ IBEX-Series X X Inspect cell condition of each cell in contrast to the monthly inspection. Verify the structural integrity of the battery rack N/A Visual 22 Tel: Fax: info@eepowersolutions.com V1.0

22 IEEE / NERC Ultra Max Plus Battery Testing Kit Product Overview The Ultra-Max Plus Kit is the complete solution for testing per IEEE and NERC standards. The Ultra-Max Plus Kit has three parts: an IBEX-Ultra Portable Ohmic Battery Tester, SG- Ultra Max Digital Hydrometer, and Exmons Ultra+ All-in-One Management Software. IBEX-Ultra Key Specs: SG-Ultra Max Key Specs: Complete Ultra Max Plus Kit Battery Capacity Range: Ah Voltage & I.R. Range: 0 60 VDC / I.R. 50 VDC Internal Storage: 600 or 4800 Test Results, 4 or 80 Battery Models Resolution: Voltage: 10 mv Resistance: mω Temperature: 0.5 C (0.5 F) Accuracy: DC Voltage: ±0.5% Internal Resistance: ±0.5% Temperature: ±2.0% Measurement Range: Density: g/cm3 Sample Temperature: *0 80 C ( F) Viscosity: 0 1,000 mpa Internal Memory: 1024 Results Resolution: g/cm3 Accuracy: Density: g/cm3 Temperature: ±0.2 C (±0.4 F) Operating Environment: C ( F) The Ultra-Max Plus Kit tests internal resistance, voltage, connection resistance, temperature, DC current, ripple current, specific gravity (state of charge), and electrolyte temperature. Eagle Eye s IEEE/NERC Kits are completely customized to meet your specific battery testing requirements. Let us know your specific applications, testing requirements and budget, and we can tailor a battery testing kit to fit your needs. Features Complete Battery Testing Kit meets IEEE/NERC Requirements for battery maintenance Measures: Internal Resistance, Voltage, Inter-Cell Resistance, Temperature, DC Current, Ripple Current, Specific Gravity and Electrolyte Temperature Store up to 4,800 results with IBEX-Ultra and 1,024 with SG-Ultra Max Exmons Ultra+ Software included for All-in-One battery management IEEE / NERC Requirements Meets IEEE Standards: , , NERC Compliance: PRC Kit Includes IBEX-Ultra Kit SG-Ultra Max Kit Exmons Ultra Plus Management Software Battery Test Equipment IEEE / NERC KITS 1 Ultra Max Plus Kit IBEX-Ultra Battery Tester, SG-Ultra Max Digital Hydrometer, Exmons Ultra Plus Software Tel: Fax: info@eepowersolutions.com V1.1 23

23 IBEX-Series Portable Battery Testers Product Description The IBEX-Series Portable Battery Testers are the fastest, smallest and most accurate battery testers in the industry today. Ensure reliability of backup power systems and prevent unexpected failures with the IBEX-Series. Eagle Eye Power Solutions offers multiple IBEX kit options to meet any company s needs and budget. Test internal resistance or conductance, cell voltage, ripple current, temperature, and connection resistance to ensure you are testing per IEEE and NERC Recommendations. Portable Battery Testers IBEX-SERIES IBEX-Ultra Kit Product Advantages IEEE Recommended: Meets IEEE Std and 2005 Recommended Practice for Maintenance, Testing, and Replacement for Stationary Applications Precise & Repeatable: Utilizes a patented ripple-removing algorithm Durable: Simple design with no moving parts Online Tester: Test batteries while they are in service Fast: Automatically measures and stores data in just 3-4 seconds Comprehensive Battery Diagnostic Software: Available software provides an easy to use interface for data management, trending analysis, exporting to excel, viewing graphs and creating reports Battery Bank Management: Upload battery bank and alarm information to the IBEX from the included software Charging ripple current analysis (%) with IBEX-Ultra The IBEX-Series is commonly used in the utility, telecommunications, UPS, transportation, and mission critical industries, and is the preferred battery tester by service groups worldwide. The IBEX injects a minimal test current into the tested batteries and precise & repeatable results appear in just 3 seconds. Battery Management Software is included with each IBEX-Series kit to easily identify bad cells, create reports, save data, and ensure the integrity of backup power systems. IBEX-Ultra with 4-Pin Test Leads and CT Clamp Meter Extender Rods All IBEX Models: (Standard Kit) IBEX-Ultra : IBEX-Pro: IBEX-EX: Optional: IBEX Kits Include IBEX Body, Soft-Poly-Vinyl Bag, 4-Pin Test Leads, Li-Ion Battery, USB Cable, Serial Comm Software, Standard Charger (100 to 240 VAC), Hard Plastic Carrying Case, User Manual Exmons Ultra Software, Temperature Probe, 0.5mΩ Shunt, Spare 4-Pin Test Lead Tips, DC Clamp Meter Exmons Ultra, 0.5mΩ Shunt, Spare 4-Pin Test Lead Tips Standard Kit Modular Extender Rods with LED light (91 cm, 3 ft) for testing UPS cabinets; Thermal Printer, Paper Rolls for IR Printer 24 Tel: Fax: info@eepowersolutions.com V1.3

24 Battery Types: Parameters Measured: Measurement Range: Accuracy: Resolution: Test Speed: Test Load: Alarms: Calibration Method: Data Transfer: Display: Internal Storage: Alarms: Operating Environment: Power Requirements: Dimensions / Weight: Exmons Battery Management Software VLA, VLRA, Ni-Cad, & Others Internal Ohmic Resistance, Inter-Cell Resistance, Voltage, Temperature, DC Current (Ultra), DC Ripple Current (Ultra) Battery Capacity: Ah Voltage: 0 60 VDC Ohmic Range: mΩ DC Voltage: ±0.5% Internal Resistance: ±1.0% Temperature: ±2.0% DC Voltage: 10 mv Internal Resistance: mω Temperature: 0.5 C (0.5 F) 3 4 seconds per cell/unit Less than 2 A per cell/unit Voltage Over & Under, Resistance Warning & Fail, Temperature Over Auto Calibration USB Cable to PC Backlit LCD IBEX-Ultra: 4800 Results IBEX-Pro & EX: 600 Results IBEX-Ultra: 80 Alarms IBEX-Pro & EX: 4 Alarms C ( F) Li-ion Battery Pack (2200 mah, 11.1V) 3 4 Hours of testing 175 x 95 x 42 mm (6.8 x 3.7 x 1.6 in) / 0.65 kg (1.4 lbs) Exmons Battery Management Software Import test data from the IBEX and Digital Hydrometers Organize test data into structured groups including the test site, battery bank, and test date Analyze trends in battery health by trending battery systems over time Easily identify problematic cells through colored graphs and cells Generate Reports or export directly to Microsoft Excel Available in three versions to best fit your needs - uploading specific gravity possible with the complete IEEE/NERC Kit Applications Utilities UPS Service Groups Oil, Gas, Fuel Green Energy Nuclear Power Municipalities Mining Hospitals Motive Power Telecommunication Transportation Mission Critical Facilities Industrial Manufacturing Battery Manufacturers and Suppliers Complete IEEE/NERC- Kit IBEX-Ultra Battery Tester SG-Ultra Max Digital Hydrometer Exmons Ultra Plus All-in- One Software Portable Battery Testers IBEX-SERIES 1 IBEX-Ultra ULTRA Intelligent Battery Examiner Kit with Exmons Ultra Software 2 IBEX-Pro PRO Intelligent Battery Examiner Kit with Exmons Ultra Software 3 IBEX-EX Economy Intelligent Battery Examiner Kit with Serial Comm Data Utility Tel: Fax: info@eepowersolutions.com V1.3 25

25 SG-Ultra Max Digital Hydrometer/Density Meter Product Overview The SG-Ultra Max measures the density and density-related values of your sample within seconds. Results appear on the backlit LCD screen and are ready for storage, printout or export to a PC. The lightweight and robust design enable on-site operation in a wide range of environments. Completely sealed, pump spills do not enter the instrument. The SG-Ultra Max digital hydrometer features leak-proof housing for operation in industrial and field applications including battery testing for utilities and telecoms, food & beverage testing, quality control, biotechnology, and many more. Supported measuring units include: density, density at reference temperature, specific gravity, alcohol, API, Baumé, Brix, and five programmable custom functions to ensure your measurement requirements. Digital Hydrometers SG-SERIES SG-Ultra Max Measurement Range: Accuracy: Resolution: Repeatability: Minimum Sample Volume: Communication: Display: Internal Storage: Operating Environment: Power Requirements: Dimensions: Weight: Product Advantages % Accurate, tests density and temperature simultaneously User-Friendly Compact, lightweight, and allows for one-hand measurement. Large backlit LCD display. Robust & rugged, comes with protective carrying case. Sustains tough field environments with leak-proof housing Wireless Communication Infrared data interface for data exchange with a PC and data export to a printer. Stores up to 1,024 total measurement results including time stamp and sample ID. Automatic temperature compensation Density: g/cm3 Sample Temperature: C ( F) Viscosity: 0 1,000 mpa Density: g/cm3 Temperature: ±0.2 C (±0.4 F) g/cm g/cm3 2 ml IrDA Interface Backlit LCD 1024 Results C ( F) (2) AA Batteries 140 x 138 x 27 mm (5.5 x 5.4 x 1.0 in) 368 g (13 oz) (1) Sample must not freeze in the measuring cell. 1 SG-Ultra Max Digital Hydrometer, Data-Logging, Range: SG-Ultra Max Kit Kit Includes SG-Ultra Max 180 mm Sample Tube 2 ml Plastic Syringes Luer Adapter 1/4 UNF IrDA Adapter Interface for Exporting Data to PC Carrying Case Electronic User Manual 2 SG-Ultra Max Ex-Petrol Intrinsically Safe Digital Hydrometer, Data-Logging, Range: Tel: Fax: info@eepowersolutions.com V1.1

26 SG-Ultra Digital Hydrometer/Density Meter Product Overview The SG-Ultra digital hydrometer/density meter offers % accurate, temperature-compensated specific gravity, density, and density-related values. Select from multiple units of measure to suit your measurement needs or create custom user-defined requirements. Results include sample identification, measurement unit, temperature correction coefficient, instrument identification and date & time. Results can be downloaded to a printer or PC easily. Reliable results appear in just 3 seconds - just immerse the sampling tube, pull the trigger, and read the final result. Trend results with included management software. The SG-Ultra is commonly used for battery testing (lead-acid & Ni-cad), alcohol and food testing, petroleum testing, and other custom density tests. SG-Ultra Measurement Range: Accuracy: Resolution: Minimum Sample Volume: Communication: Display: Internal Storage: Operating Environment: Power Requirements: Dimensions: Advantages Accurate % Accurate User-Friendly Compact, lightweight, and allows for one-hand measurement. Large LCD display screen with back-light Robust & rugged, comes with protective carrying case. Sustains tough field environments with a sealed housing Wireless Communication Infrared data interface for data exchange with a PC and data export to a printer (data transfer accessories included) Storage of up to 1100 results including sample ID, measurement unit, temperature correction coefficient, instrument identification, date and time Reliable CE Compliant and One Year Density: g/cm3 Sample Temperature: C ( F) Viscosity: 0 2,000 mpa Density: g/cm3 Temperature: ±0.2 C (±0.4 F) g/cm3 2 ml IrDA Interface Backlit LCD 1100 Results C ( F) (2) AAA Batteries 229 x 114 x 64 mm (9 x 4.5 x 2.5 in) Weight: 360 g (2.7 oz) Sample Tube Dimensions: 178 x mm / 7 x 1/8 in. Diameter *Custom lengths available (1) Sample must not freeze in the measuring cell SG-Ultra Kit Kit Includes SG-Ultra with Protective Boot Sample Tube (7 x 1/8 ) IrDA Adapters SG-Ultra Management Software Carrying Case User Manual Digital Hydrometers SG-SERIES 1 SG-Ultra Digital Hydrometer, Data-Logging, Range: Tel: Fax: info@eepowersolutions.com V1.1 27

27 SG-1000 Digital Hydrometer / Specific Gravity Tester Product Overview The SG-1000 digital hydrometer / specific gravity tester is specifically designed to quickly & safely measure the temperature-compensated specific gravity of your batteries. The SG-1000 is critical in determining the charge level of leadacid batteries, without touching any liquid or cumbersome cleaning. Singlehanded automatic operation makes this method 10x faster than conventional glass hydrometer and thermometer methods. Measure specific gravity and temperature simultaneously with a press of a button. To measure battery electrolytes, simply extract a sample in your suction tube and press the START button. The temperature-compensated specific gravity is displayed on the screen. The user can select between the specific gravity reading and temperature reading by pressing the SELECT button. Measurement results are displayed in just three seconds. Digital Hydrometers SG-SERIES SG-1000 Battery Digital Hydrometer Measurement Range: Accuracy: Advantages % Accurate 10x faster than conventional methods Measure specific gravity and temperature simultaneously Automatic temperature compensation Rugged & Durable Digital display CE Compliant Specific Gravity of Electrolyte: Available upon request: Sample Temperature: C ( F) ±0.002 Specific Gravity Applications Telecom/Communications Utilities Mining Government/Defense Industrial Manufacturing Motive Power Resolution: Display: Operating Environment: Power Requirements: Dimensions: Weight: g/cm3 Digital LCD C ( F) 9V Battery 70 x 40 x 210 mm (2.8 x 1.6 x 8.3 in) 235 g (8 oz) SG-1000 Kit Kit Includes SG-1000 Body 9V Battery Three (3) Sample Tubes Hand Strap Carrying Case User Manual 1 SG-1000F Battery Digital Hydrometer, Non-Datalogging, Range: , F 2 SG-1000C Battery Digital Hydrometer, Non-Datalogging, Range: , C 28 Tel: Fax: info@eepowersolutions.com V1.2

28 DLV-Max Battery Testing Kit Product Overview The DLV-Max Battery Testing Kit includes the DLV-Pro data logging voltmeter with the SG-Ultra Max digital hydrometer for a complete solution to voltage and specific gravity testing. The DLV-Pro measures and records cell voltages in less than 1 second, enabling rapid testing of battery cell voltages. Voltages are recorded in two formats: 8 strings of 256 or 20 strings of 48 readings. Specific gravity and temperature readings measured from the SG-Ultra Max are directly uploaded to the DLV-Max in 8 strings of 256 format. Both voltage and specific gravity readings can be combined into a single report. DLV-Pro Voltmeter & SG-Ultra Max Digital Hydrometer Features Record, view, & analyze cell voltage, SG, & temperature readings Record voltage in either 8 strings of 256 or 20 strings of 48 format Record SG in 8 strings of 256 format Perform a full discharge test & analyze results on-site during the test Easily transfer data files to Winmeter 5.1 battery analysis software Export test data to PDF reports or Excel spreadsheets Replay animated discharge tests The DLV-Max kit can also be used to perform a full discharge test on up to 256 cells by recording up to 11 time-stamped voltage readings for each cell, along with time-stamped load current readings and initial and/or final SG readings via the SG-Ultra Max. All test data can be uploaded to a PC using the included Winmeter 5.1 Battery Analysis Software. Generate Reports for Voltage, SG, and Temperature Portable Battery Test Kits DLV-SERIES Item DLV-Pro SG-Ultra Max Measurement Range Accuracy Memory Cell Voltage: 0 20V 0 4V: ±5mV 4 20V: ±10mV Voltage: 8 by 256, 20 by 48 SG & Temp: 8 by 256 Density: g/cm 3 Temp: 0 80 C ( F) Density: 0.001g/cm 3 Temp: ±0.2 C (±0.4 F) 1024 Sequential Test Results Operating Temp 0 40 C ( F) C ( F) Battery Life 3.7V Li-Ion Rechargeable, 20 Hours Industrial (2) AA, 100 Hours Size / Weight 160 x 76 x 33mm (6.3 x 3 x 1.3in) 298g (10.5oz) 140 x 138 x 27mm (5.5 x 5.4 x 1.0in) 368g (13oz) 1 DLV-Max Kit DLV-Pro Data Logging Voltmeter, 0 20 VDC SG-Ultra Max Digital Hydrometer, 0 3 g/cm 3 Kit Includes DLV-Pro Voltage Tester Voltage Test Leads SG-Ultra Max Digital Hydrometer Carrying Case Winmeter Analysis Software Tel: Fax: info@eepowersolutions.com V1.0 29

29 SG-100M Electronic Hydrometer / Liquid Density Monitor Model # SG-100M SG-100M Digital Hydrometer Product Overview The SG-100M Specific Gravity Meter/Liquid Density Monitor will replace ordinary glass bulb and optical refractometer hydrometers that are limited in range, utility and functionality. The SG-100M has an in-tank, drop-hang submersible probe that measures, monitors, records, and controls specific gravity/liquid density during a mixing, blending, fermentation, distillation, or plating operation. The SG-100M offers many user-customized options that allow the instrument to fit your exact measuring needs. The measurement probe can be purchased independently for integration into an existing PLC (Programmable Logic Controller). Optional 4-20mA analog output board or dual 5 amp relays for process control are also available. Simply submerge the measuring probe up to 500 feet and connect to an electronics module to provide digital readouts of user defined values such as Density, Specific Gravity, Baume, Brix and Alcohol %. Digital Hydrometers SG-SERIES Advantages % Accurate, measures in liquids or slurries Pressure irrelevant - can monitor density at any depth Remote readout at desired distance from probe Readout can be chosen in preferred engineering units Battery or In-tank operation depending on application Determines concentration mix (by volume or mass) of the sample Large sample temperature ranges (up to 106 C / 220 F) Customization available based on user needs Measurement Range: Pressure Range: Accuracy: Resolution: Repeatability: Minimum Sample Volume: Data Transfer: Operating Environment: Power Requirements: Dimensions 1 : Weight: Cable Length: Density: g/cm3* Sample Temperature: C ( F) 0 5 atm (operable in vacuum) ±0.005 g/cm3 ±0.001 g/cm3 ±0.004 g/cm3 310 ml Analog Voltage Data Logger (optional) 4 20 ma, dual 5 A Relay C ( F) Control Module: 120/240 VAC** Probe: 0 5 VDC Probe Length x Diameter: 280 x 51 mm (11 x 2 in) Probe: 2.3 kg (5 lbs) Standard: PVC: m (4 500 ft) Optional: Teflon: m (5 200 ft) (1) Probe must be mounted vertically and be completely submerged in the test solution. Digital Panel Meter CPVC Probe Applications Chemical Petroleum Food & Beverage Passivation Electroplating Flux Density Control Paper Production Coatings Kit Includes SG-100M Digital Panel Meter SG-100M CPVC Probe PVC Cable (Standard Lengths: 4 ft to 100 ft) Optional: Teflon Cable for Caustic Solutions 1 SG-100M Digital Panel Meter, CPVC Probe 2 SG-100M Probe Standalone CPVC Probe 3 SG-100M with Relay Digital Panel Meter with Analog Output Board (4-20 ma) or Dual 5 A Relay, CPVC Probe 30 Tel: Fax: info@eepowersolutions.com V1.1

30 DM-Series Inline Density Meters Model # DM-Series (A) (B) (C) Product Description The DM-Series Inline Density Meters are designed for continuous monitoring and process control of liquid concentration/density and temperature of solutions across a wide range of applications. Available in three different mounting configurations, the DM-Series density meters can be integrated directly into a variety of tanks and inline systems. Temperature compensated values can be measured and displayed in Density, Specific Gravity, Brix, Plato, Baume, API, Concentration, Solid %, and other measurements of density. Designed for process control, measured data outputs through a 4-20 ma signal. Digital communication for remote calibration and monitoring is also available. DM-1000A, DM-1000B, & DM-1000C Applications Industrial Chemical Production: Petroleum, natural gas, oil refining, salt mining Food & Beverage Industry: Beverage, syrup, vegetable oil, & soft drink processing Other Chemical Production: Urea, detergents, ethylene glycol, lubricating oils, acid solutions, & polymers Paper Industry: Black pulp, green pulp, white pulp, alkali solution Measurement Range: Accuracy: Resolution: Communication Output: Display: Each unit consists of a capacitive-type differential pressure transmitter tied to a pair of pressure repeaters immersed in the solution. Temperature compensation is performed by a temperature sensor located between the two pressure repeaters. Small variations in the process temperature are quickly and accurately calculated through dedicated software. Density: g/cm3 1 Temperature: C 2 / F 2 Density 0 1 g/cm3: g/cm3 Density 0 2 g/cm3: g/cm3 Density 0 3 g/cm3: g/cm3 Temperature: 0.2 C / 0.4 F g/cm ma, HART Protocol Backlit 4.5 Digital LCD Volumetric Displacement: Less than 0.15 cm3 3 / 0.01 in3 3 Power Requirements: Operating Environment: VDC (24 VDC recommended) C / F, 0 90% RH (1) Listed total range, specific models ordered with range of 0-1, 0-2, or 0-3 g/cm3. (2) DM- 1000A & DM-1000B range is C ( F) due to installation method. (3) Varies slightly depending on individual model. Inline Measurement of Density Main Features Monitoring & Process Control: Continuously monitors process, displays real-time measurement and transmits data through a 4-20 ma output Accurate Data Display: Digital LCD displays measured data in user-configurable units which can be alternated during operation Safe for Many Environments: Intrinsically safe with no moving parts, stainless-steel wetted parts, models available for industrial or sanitary environments Easy Operation: User troubleshooting procedures with error messages to help trace cause of problem, user-calibration procedures 1 DM-1000A Vertically Top-Mounted Inline Density Meter, g/cm3, C / F 2 DM-1000B Vertically Side-Mounted Inline Density Meter, g/cm3, C / F 3 DM-1000C Vertically Side-Flex-Mounted Inline Density Meter, g/cm3, C / F Inline Density Meters DM-SERIES Tel: Fax: info@eepowersolutions.com V1.0 31

31 GFL-1000 Ground Fault Locator Product Overview The GFL-1000 Ground Fault Locator is an essential instrument to pinpoint faulty grounding where electrical cables have breakage and loss to the ground. The unit measures current leakage of DC systems with high resistance. The GFL-1000 is designed to fast-detect, track, and locate grounding faults for both offline and online DC systems. Measurement of online DC systems is possible because the output current of the GFL-1000 is very low but the output voltage can be up to 1000V. Ground Fault Locators GFL-SERIES GFL-1000 Kit Output Voltage: Output Frequency: Output Current Limitation: Fault Location Sensitivity: Current Detect Sensitivity: Quick Search Clamp: Current Sensor: Jaw Opening: Display: Operating Environment: Power Requirements: Dimensions: Weight: The GFL-1000 provides accurate solutions for troubleshooting and preventative maintenance, increasing the reliability of electrical equipment. Fast localization and elimination of grounding faults is critical to increase system reliability. The compact and rugged design make it easy to use in small places and harsh environments. The GFL-1000 ground fault locator is widely used in the telecom, utilities, and transportation industries. 24, 48, 110, 220, 500, 1000 VDC Selectable between 1, 10, 50, 60, 325 Hz 5 ma or Unlimited (Max 25mA) 1 MΩ Advantages Patented technology, pinpoint current leakage fault with grounding resistance lower than 1MΩ Locate faults for both offline and online DC systems Adjustable output frequency on Signal Receiver effectively avoids interference from DC system itself Waveform analysis will analyze the interference signal in the circuit Wide output voltage and output frequency ranges allow the GFL-1000 to meet the needs of your electronic equipment AC/DC Circuit: 0.5 ma 55 mm (diameter), 60 mm (jaw opening) φ8 and φ20 60 mm (2.36 in) Backlit Color LCD Temperature: C ( F) 8.4 VDC Li-ion Battery 360 x 260 x 135 mm (14.2 x 10.2 x 5.3 in) 7 kg (15.4 lbs) Signal Receiver Kit Includes GFL-1000 Signal Generator Power Adapter Qty. (2) Signal Testing Leads Qty. (2) Alligator Clips Punctuation Clip Signal Receiver Qty. (2) Dual-Range Current Detector Qty. (2) Batteries Battery Charger Carrying Case 1 GFL-1000 Ground Fault Locator, Range: V, Hz 32 Tel: Fax: info@eepowersolutions.com V1.3

32 TIC-Series Thermal Imaging / IR Cameras Product Overview The Eagle Eye TIC-Series Thermal Imaging Cameras are portable, rugged infrared cameras designed for use in a variety of applications including preventative maintenance, construction, medical, & more. Results appear on the built-in display in seconds, allowing the user to quickly find problem areas. Images can be stored on the micro SD card and subsequently transferred to a PC for analysis and report generation as needed. The TIC-Series Thermal Imaging / IR Cameras offer an affordable and accurate solution for any requirement and price point. TIC-1000 Thermal Imaging / IR Camera Product Features Real-Time thermal imaging Hot & cold temperature spot measurements Reflected temperature compensation Measurement offset correction Item: TIC-500 TIC-1000 Measurement Range: C ( F) C ( F) Accuracy: ± 2 C or ± 2% of reading, whichever is greater ± 2 C or ± 2% of reading, whichever is greater Display: touch screen Memory / Image Format: 16GB micro SD card 16GB micro SD card Power Requirements 41.5V (AA Battery), 6 hours Li-Ion rechargeable, 3 hours continuous use Dimensions: 62 x 212 x 95 mm (2.4 x 8.3 x 3.7 in) 105 x 245 x 230 mm (4 x 9.6 x 9 in) Weight: 320 g (0.71 lbs) 1 kg (2.2 lbs) Thermal Imaging Cameras TIC-SERIES Operating Environment: C ( F), 80% Humidity C (5-122 F), 90% Humidity Array Size / Format: 80 x 60 pixels 160 x 120 pixels FOV / Min. Focus Distance: 20 x 20 / 50 cm (19.6 in) 25 x 19 / 10 cm (3.8 in) Thermal Sensitivity: 0.15 C 0.08 C Frame Frequency: 6 Hz 50/60 Hz Zoom: N/A X2 Spectral Range: 8-14μm 8-14μm Accessories: Soft pouch, 4 (AA) batteries, USB drive with manual Carrying case, Wrist strap & lens cover, Video out cable, (2) lithium ion batteries, battery charger, TF card & card reader, USB drive with manual & software 1 TIC Hz Thermal Imaging Camera with standard accessories 2 TIC /60 Hz Thermal Imaging Camera with case, software, and standard accessories Tel: Fax: info@eepowersolutions.com V1.0 33

33 SLB-Series DC Load Banks Product Overview Eagle Eye s SMART Constant Current DC Load Banks are designed for discharge testing, battery capacity testing, acceptance testing, battery maintenance and other testing for DC power with a load. The SLB-Series load banks are portable, economic, easy-to-use and come complete with DataView Software for data management and analysis. The SMART technology allows a constant current discharge without the need for any adjustments during the test. With over 35 standard models, the SLB-Series is used in a variety of industries including utilities, telecommunications, UPS, motive power/forklifts, transportation, CATV, and many more. Custom Solutions are available. Eagle Eye load banks are designed to make discharge testing convenient and easy for any application. SMART DC Load Banks SLB-SERIES SLB-Series DC Load Bank Data Acquisition Case (DAC): Eagle Eye s SMART Load Banks come with an optional DAC package allowing the voltage of EACH CELL to be wirelessly recorded and displayed during discharge. The DAC package allows the user to evaluate the health of each cell and replace only the cells that require replacement - saving time and money by significantly reducing labor hours and replacement costs. Product Features SMART Constant Current DC Load Banks with system and cell/ unit voltage monitoring Data management software included for data analyzing and reporting Four settings for auto shut-down of discharge: discharge time, total string end voltage, cell end voltage, discharged capacity Parallel connection of two units for increased discharge capacity Thermal cut-off and automatic overload protection Optional: Real-time display of voltage for each cell/unit with DAC package for 1.2V, 2V, 6V, 12V cells Optional: Custom DAC packages available for monitoring of uncommon cell voltages and configurations DAC Connection to 48V Battery (2V) Cells Typical connection of DAC s to the battery cells include a test lead connected to each cell from the DAC. Each DAC can connect up to 12 cells. DAC s are expandable to any size battery system and are compatible with VRLA, VLA, NiCad, and other battery types. Data Acquisition Case (DAC) 34 Tel: Fax: info@eepowersolutions.com V1.3

34 Discharge DataView Software The included DataView software allows the user to monitor the discharge test in real-time or import and view tested data from the load bank with the provided USB drive. View and print a detailed histogram of each cell s voltage from any point during the discharge test at user defined intervals of 15, 30, or 60 minutes. Cell Voltage: Discharge Current Range: Discharge Voltage Range: Standard DAC: 1.2V 1, 2V, 6V, 12V / Optional: Custom DAC configurations available upon request Single Load: A / Parallel Load: Up to 1200A Range: V (Max) / Voltage Steps: 12V, 24V, 36V, 48V, 80V, 125V, 240V, 380V, 480V Accuracy: Discharge Current: 1% / Voltage: 0.5% 0.8% Resolution: Sampling Interval: Data Transfer: Display: Operating Environment: Power Requirements: Dimensions: Weight: Real-Time Data Logging of Cell Voltage Discharge Current: 0.1 A or 0.5% / Voltage: V 5 seconds 1 minute USB, Wireless (466 MHz) Backlit LCD 0 40 C ( F) 110/220 VAC 50/60 Hz / DC (from connected batteries) Small: 400 x 177 x 288 mm (15.7 x 7 x 11.3 in) Medium: 520 x 202 x 355 mm (20.5 x 8 x 14 in) Large: 555 x 225 x 435 mm (22.5 x 8.9 x 17.2 in) X-Large: 603 x 400 x 740 mm (23.7 x 15.7 x 29 in) XX-Large: 762 x 406 x 737 mm (30 x 16 x 29 in) Small: 11 kg (24 lbs) Medium: 16 kg (36 lbs) Large: 21 kg (47 lbs) X-Large: 42 kg (93 lbs) XX-Large: 55 kg (122 lbs) (1)The standard DAC package includes quantity of DAC s & cabling for 2V/6V/12V batteries; testing of 1.2V NiCad batteries require additional DAC & cabling. Please make sure to note testing of NiCad to your sales rep. Recorded data exports directly to Microsoft Excel. Users are able to customize the report with company name and location as well as input battery information including battery make, cell type, rated capacity, and more. The complete test criteria, weakest cells, string information, and individual cell information are included in the report. Graphs for string, and cells are also available to view in the software. Kit Includes SLB-Series Load Bank DataView Management Software Carrying Case (for small & medium size models) Set of 3m/10ft Load Cables 3m/10ft Voltage Test Leads PC communication interface Ground Cable AC Power Cord USB Drive with Software/ User Manual (2) Antenna Optional: Standard DAC Package Optional: CT Clamp for Assisted or External Load Testing Optional: Parallel Load Cable SMART DC Load Banks SLB-SERIES 1 SLB-Series* SMART Constant Current DC Load Bank with Monitoring (12-480V, A) *See next page for listing of model numbers *Add DAC after model number for wireless monitoring per cell Tel: Fax: info@eepowersolutions.com V1.3 35

35 SLB-Series Standard Models SMART DC Load Banks SLB-SERIES Maximum Discharge Current At: No Model 12VDC 24VDC 28VDC 36VDC 48VDC 80VDC 125VDC 240VDC 380VDC 480VDC 1 SLB ~ 300 ~ ~ ~ ~ ~ ~ ~ ~ 2 SLB ~ ~ ~ ~ ~ ~ ~ ~ 3 SLB ~ ~ ~ ~ ~ ~ ~ ~ 4 SLB-24/ ~ ~ ~ ~ ~ ~ 5 SLB-24/ ~ ~ ~ ~ ~ ~ 6 SLB-24/36/ ~ ~ ~ ~ ~ 7 SLB-24/36/48/ ~ 200 ~ ~ ~ ~ ~ 8 SLB-24/ ~ 200 ~ 200 ~ ~ ~ ~ ~ ~ 9 SLB-24/ ~ ~ ~ ~ ~ 10 SLB-24/48-300/ ~ ~ ~ ~ ~ 11 SLB-24/ ~ ~ ~ ~ ~ 12 SLB ~ ~ ~ ~ ~ ~ ~ 13 SLB ~ ~ ~ ~ ~ ~ ~ 14 SLB ~ ~ ~ ~ ~ ~ ~ 15 SLB ~ ~ ~ ~ ~ ~ ~ 16 SLB ~ ~ ~ ~ 100 ~ ~ ~ ~ ~ 17 SLB ~ ~ ~ ~ 150 ~ ~ ~ ~ ~ 18 SLB ~ ~ ~ ~ ~ 19 SLB ~ ~ ~ ~ 400 ~ ~ ~ ~ ~ 20 SLB ~ ~ ~ ~ ~ 21 SLB-48/ ~ ~ ~ 22 SLB-48/ ~ ~ ~ 23 SLB-48/ ~ ~ ~ 24 SLB-48/ ~ ~ 25 SLB v-200A ~ ~ 26 SLB ~ ~ ~ ~ 27 SLB ~ ~ ~ ~ 28 SLB ~ ~ ~ ~ ~ ~ 100 ~ ~ ~ 29 SLB ~ ~ ~ 30 SLB ~ ~ ~ 31 SLB ~ ~ ~ 32 SLB-125/ ~ ~ 33 SLB-125/ ~ ~ 34 SLB ~ ~ 35 SLB ~ ~ ~ ~ ~ ~ ~ 200 ~ ~ 36 SLB ~ ~ ~ ~ ~ ~ ~ ~ 50 ~ 37 SLB ~ ~ ~ ~ ~ ~ ~ ~ 100 ~ 38 LB *Custom models available upon request 36 Tel: Fax: info@eepowersolutions.com V1.3

36 LB-Series Constant Current DC Load Banks Product Overview Eagle Eye s LB-Series Constant Current DC Load Banks are designed for discharge testing, battery capacity testing, acceptance testing, battery maintenance, and other testing of DC systems. The LB-Series constant current load banks are portable, economic, reliable and user-friendly. The intelligent technology allows a constant current discharge without the need for any adjustments during the test. The LB-Series is used in a variety of industries including utilities, telecommunications, UPS, motive power / forklifts, transportation, CATV, and many more. LB CC Current Range: 0 600A Voltage Range: Standard: 1 480V Accuracy: Discharge Current: 0.1A Voltage: 0.1V Control Precision: ±0.3% / +0.2A Display: Backlit numeric LED Operating Environment: C ( F) 0 90% relative humidity Input Voltage: 110/220 VAC 50/60 Hz Cooling: Forced air cooling Product Features LED display for voltage, current, & test duration Easily program test parameters with simple keypad Three test conditions for discharge auto-stop: Test Time, End Voltage, Exceeded Capacity Unit will alarm and end discharge in the event of overheating, abnormal disconnection of battery, improper polarity detected Cooling fans continue to run automatically after each test to ensure maximum heat protection. Previously used parameters saved after powering off the machine Kit Includes LB-Series CC Load Bank 3 m (10 ft) Discharge Cables 110/220 AC Power Cable One-year Standard Warranty Constant Current DC Load Banks LB-SERIES 1 LB-24/36/48-150/225/300-CC 24V-150A, 36V-225A, 48V-300A Constant Current DC Load Bank 2 LB-24/36/48-250/375/500-CC 24V-250A, 36V-375A, 48V-500A Constant Current DC Load Bank 3 LB-24/36/48-300/450/600-CC 24V-300A, 36V-450A, 48V-600A Constant Current DC Load Bank 4 LB CC 48V-100A Constant Current DC Load Bank 5 LB CC 48V-200A Constant Current DC Load Bank 6 LB CC 48V-300A Constant Current DC Load Bank 7 LB CC 48V-500A Constant Current DC Load Bank 8 LB CC 48V-600A Constant Current DC Load Bank 9 LB CC 80V-100A Constant Current DC Load Bank 10 LB CC 480V-200A Constant Current DC Load Bank 11 LB CC 480V-300A Constant Current DC Load Bank Tel: Fax: info@eepowersolutions.com V1.3 37

37 LB-Series AC Load Banks Product Overview The LB-Series AC Load Banks are designed to provide a temporary load for field servicing and testing generators and inverters. Eagle Eye s AC Load Banks are among the smallest AC load banks in the industry that offer unmatched capacities with rugged durability. LB AC Load Bank Each AC Load Bank is fully self-contained and designed for portable AC load testing that can easily withstand harsh testing environments. Straightforward individual fan switches, load step switches, and master load switches make each unit user-friendly. Safety features are equipped on every AC Load Bank for fast acting, branch circuit fuse protection and sensors to prevent overheating and current overload. Each LB-Series AC Load Bank comes in a padded AC Load Banks LB-SERIES LB Load Steps: LB Meters: LB Load Steps: LB Meters: LB Load Steps: 120VAC Single Phase:.33,.66,.66, 1.66, 3.33, 3.33 KW 240VAC Single Phase:.66, 1.33, 1.33, 3.33, 6.66, 6.66 KW 208VAC Three Phase: 1, 2, 2, 5, 10, 10 KW 0-150V Voltmeter 0-100A Ammeter 55-65HZ Frequency Meter 120VAC Single Phase: 1.6, 1.6, 3.2, 3.2, 3.2 KW 240VAC Single Phase: 6.5, 6.5, 13, 13, 13 KW 208VAC Three Phase: 10, 10, 20, 20, 20 KW 480VAC Three Phase: 12.5, 12.5, 25, 25, 25 KW 0-600V Voltmeter 0-250A Ammeter 55-65HZ Frequency Meter 200VAC Three Phase: 9, 18, 27, 36, 42, 54, 63, 72 KW Product Features Portable, lightweight, and durable Temperature sensor removes load when over-temperature is detected Easy-to-use switches & controls for fan, load steps & master load Low-noise, high velocity cooling system Power indicator lights Quick connect for cables LB Meters: LB D Load Steps: LB D Meters: 0-250V Voltmeter 0-250A Ammeter HZ Frequency Meter 200VAC Three Phase: 10, 19, 28, 37, 46, 55, 64, 73, 82, 91, 100, 109 KW V Voltmeter 0-999A Ammeter HZ Frequency Meter Kit Includes LB-Series AC Load Bank Portable Carrying Case 10 Cables User Manual 1 LB HZ 120/240VAC SINGLE PHASE 208V 3PHASE 30KW 2 LB HZ 480/208 3PHASE 100KW AT 480VAC AND 80KW AT 208VAC 3 LB HZ 72KW IN 8 9KW STEPS UP TO 72KW CONTINUOUS 4 LB D 400HZ 100KW IN 12 STEPS 10, 19, 28, 37, 46, 55, 64, 73, 82, 91, Tel: Fax: info@eepowersolutions.com V1.1

38 LB-1000 Battery Charger / Discharger / Activator Product Overview The LB-1000 is a complete solution for daily battery maintenance of single jars or cells up to 12V. It offers three complete solutions: battery charger, battery discharger and battery activator. Each test functionality can be used individually or comprehensively - when used comprehensively, lag-out battery will experience low-volt constant current charging and discharging of single or multi-cell batteries (1 100A). By activating the disabled active material of the battery electrode plate, it amends the battery malfunction caused by chemical failure and boosts the capacity of an old battery. Activation curve and certain parameters (Ex. voltage and resistance) will display on the screen as activation ends. LB-1000 Charge Current per Cell Voltage: 1.2V: 1 50A 2V: 1 100A 6V: 1 30A 12V: 1 30A Discharge Current per Cell Voltage: 1.2V: 1 25A (1) 2V: 1 100A 6V: 1 30A 12V: 1 30A Charge & Discharge Voltage per Cell Voltage: 1.2V: V 2V: V 6V: V 12V: V Display: Features Designed for testing cells of 1.2V, 2V, 6V, and 12V 3-in-1 functionality: charger, discharger, and activator (used separately or comprehensively) Accurate test results with vivid waveforms Designed to charge/discharge single and multi-cell batteries Included Data Management Software with reporting capability Safety circuits prevent damage to battery during testing Compact unit with rolling carrying case 128 x 64 pixel color LCD Power Requirements: AC 110/60Hz or AC 230/50Hz (2) Operating Environment: Dimensions: Weight: 0 50 C ( F), 5 90% RH 40 x 30 x 20 cm (15.7 x 11.8 x 7.9 in) 10 kg (22 lbs) (1) Available discharge current per 1.2V cells can vary depending on battery capacity. (2) Desired input voltage must be stated at time of order. Kit Includes LB-1000 Main Unit Voltage Test Leads Positive & negative Load Cables AC Power Cord LB-1000 Analyzing Software Carrying Case User Manual 1 LB-1000 Battery Charger, Discharger, Activator for 1.2V, 2V, 6V, & 12V Cells Portable Load Banks LB-SERIES Tel: Fax: info@eepowersolutions.com V1.4 39

39 BR-200 Battery Regenerator & Discharger Product Overview The BR-200 Battery Regenerator & Discharger is a compact, multifunctional 5-in-1 regenerator for 6V, 8V, and 12V lead-acid batteries. By using intelligent smart control pulsing technology to increase battery capacity, Eagle Eye s regenerators are the most advanced and effective in the industry. The regeneration process minimizes damage of electrodes and plates by using the optimized high frequency pulse technology. The built-in software algorithm searches for the optimum frequency to restore battery capacity by using a built-in microprocessor, allowing faster regeneration speeds. Battery Regenerator BR-SERIES BR-200 Regenerator & Discharger Kit Includes BR-200 Battery Regenerator & Discharger Clip Probe Cables Power Cord User Manual Features 5 Main Functions: Regenerator, Power Supply, Discharger Internal Resistance Tester, and Cold Cranking Ampere (CCA) Tester Save money in battery replacement costs by extending battery life more than double the original lifespan Easy to use LCD power display - see measurements and condition in real-time Over-voltage protection - maintains low battery temperature during restoring Innovative pulse technology allows charging and restoring simultaneously Pulse technology restores up to 50% faster than other regenerators Battery Voltage: Standard DC 6V, 8V, 12V Battery Types: Lead Acid (20Ah - 300Ah) Input Power: AC V, V / 50-60Hz Max Output: 240W (DC 6V: 10A and DC 8V & 12V: 15A) Discharge Capacity: Approx. 420 Watts Maximum Discharge Current: 30A Input Voltage: 480V Power Consumption: (Standby) Approx. 20W (Maximum) Approx. 200W Regeneration Method: Charge Current Inclusive High Frequency Pulse Dimensions 345 x 370 x 170 mm (13 x 14 x 7 in) Weight: 9 kg (20 lb) 1 BR-200 Battery Regenerator & Discharger for 6V, 8V, and 12V lead-acid batteries 40 Tel: Fax: info@eepowersolutions.com V1.0

40 BR-500 Battery Regenerator & Charger Product Overview The BR-500 Battery Regenerator & Charger is a multifunctional, universal 3-in-1 regenerator for 2-96V lead-acid batteries. By using intelligent smart control pulsing technology to increase battery capacity, Eagle Eye s regenerators are the most advanced and effective in the industry. The regeneration process minimizes damage of electrode plates by using the optimized high frequency pulse technology to successfully remove sulfation. The current pulses and converts sulfate crystals back to liquid molecules in the electrolyte. The BR-500 automatically controls voltage and current per type of battery. The built-in software algorithm searches for the optimum frequency to restore battery capacity by using a built-in microprocessor, allowing faster regeneration speeds. Increase battery recharging efficiency and prolong battery lifespan with the BR-500 Battery Regenerator. BR-500 Regenerator & Charger Features 3 Main Functions: Battery Regenerator, Charger, and Power Supply Universal design - can regenerate all types of lead-acid, GEL and AGM batteries Save money in battery replacement costs by extending battery life more than twice the original lifespan User-friendly 8 inch digital touch screen to program tests and view history Regeneration and charging begins in 5-simple steps using touch screen Over-voltage & surge protection - maintains low battery temperature during restoring Innovative pulse technology allows charging and restoring simultaneously Pulse technology restores up to 50% faster than other regenerators Save & print reports when results are transferred from the BR-500 to a PC via USB - allowing a detailed analysis of the regeneration process Battery Regenerator BR-SERIES Battery Voltage: Nominal DC 2-96V Battery Types: Lead Acid (40-3,000Ah) Input Power: AC V / Hz Max Output: 3.00KW Power Consumption: (Standby) Approx. 20W (Maximum) Approx. 2.5W Regeneration Method: Charge Current Inclusive High Frequency Pulse Dimensions 480 x 400 x 1010 mm (19 x 16 x 40 in) Weight: 50 kg (110 lbs) Kit Includes BR-500 Battery Regenerator & Charger Regenerator Cables AC Power Cord User Manual 1 BR-500 Battery Regenerator, Charger & Power Supply for 2-96V lead-acid, GEL or AGM batteries Tel: Fax: info@eepowersolutions.com V1.1 41

41 EnerGenius IQ Automatic DC Power Supply/Battery Charger Product Description The EnerGenius IQ Automatic DC Power Supply/Battery Charger delivers DC power and charges your battery system while testing battery performance, logging relevant site data, & communicating the results. Built-in intelligent control system reduces recharge time and cuts risk of overcharge, maximizing the reliability of DC systems at the lowest cost. The charger simultaneously supplies smooth DC to critical loads, recharges the connected battery system, & automatically maintains VLA, VRLA, or NiCd batteries. Using Dynamic Equalize Charge, the charger automatically compensates for depth of discharge, varying load, battery age, & other variables. Battery Chargers BC-SERIES Energenius IQ, Size Q1 & Q2 Included standard on every EnerGenius IQ is an on-board battery check system to determine if your battery can support a connected continuous load without taking the battery offline or shutting down the charger. Black box data recorder captures and logs previously unavailable system and site data needed to analyze failures and demonstrate if site conditions are harming battery life. Dual microprocessors provide internal fault tolerance & provide a level of system reliability superior to either conventional analog or single microprocessor-controlled chargers. CommsGenius Communications Module allows data gathered by the charger to be used to improve reliability of battery sites through the provided Insight PCbased application or their own networks. CommsGenius provides networking (RS- 485 and Ethernet), precise digital load sharing for two chargers, and PC-based charger setup and administration. Features Built-in Intelligence makes it easy to correctly configure charger for battery & site conditions Battery Check System automatically tests battery to reduce risk of expected application shutdown Black Box Data Recorder helps spot previously hidden problems Advanced User Interface, USB PC Utility provide easy to understand system status & control Modbus Communication Option provides remote monitoring EnerGenius Control Panel AC Input Voltage: DC Output Voltage: Current Ratings: Voltage Regulation: +0.25% Current Limit Adjust: Operating Environment: Agency Compliance: Dimensions 1 : 120/208/240 VAC, 60 Hz or 50/60Hz 12, 24, 48, 11/220 or 220/240 VDC nominal 6, 12, 16, 25, 35, 50 Amps 33% 110% rated output C ( F) Recommended UL Listed Q1 Housing: 330 x 493 x 448 mm (13 x 19.4 x 17.6 in) Q2 Housing: 409 x 600 x 707 mm (16.1 x 23.6 x in) (1) Charger housing offered in two sizes, housing weight can vary based on specifications. Applications Electric Utility Substations Switchgear Refineries & Chemical Plants DC Control Systems Engine Starting Oil & Gas Pipelines Offshore Platforms 1 EnerGenius IQ Single Phase Battery Charger - Request Order Form to build your own custom model 42 Tel: Fax: info@eepowersolutions.com V1.1

42 AT10.1 / AT30 Microprocessor Controlled Battery Chargers Product Overview Stationary float battery chargers and rectifiers are produced with a combination of advanced technology microprocessor control and performance-engineered modular construction. Chargers are easy to set-up, operate, and maintain. Chargers are customized based on current and voltage requirements. All stationary float battery chargers have a five year warranty - providing unbeatable quality and protection. AT10.1 & AT30 Chargers VAC Input: Stationary float battery chargers are commonly used in the following industries: utilities & telecommunications, manufacturing, uninterrupted power systems (UPS), transportation, and many more. Features 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure, High VDC, Low VDC, Positive(+) and Negative(-) ground fault AC input and DC output circuit breakers High DC voltage shutdown Forced load share during parallel operation Front panel controls can be disabled for security Group 1 (6 25 ADC) Voltage: 120/208/240Vac Multi-tap 60Hz 480 VAC 60Hz 220 VAC, 380/416Vac 50/60Hz VAC 50/60Hz Group 2 ( ADC) Voltage: 120, 208, 240 or 480 VAC 60Hz 220 VAC, 380 or 416 VAC 50/60Hz VAC 50/60Hz ADC Voltage: 208 VAC 60Hz 240 VAC 60Hz 480 VAC 60Hz VAC 60Hz 220 VAC 50/60Hz 380 VAC 50/60Hz 416 VAC 50/60Hz Input Voltage Tolerance: +10%, -12% +10%, -12% Input Frequency Tolerance: ±5% ±5% Efficiency: 85-90% typical for 130 VDC at % load 85-90% typical for 130 VDC at % load VDC Output: 12, 24, 48, or 130 VDC nominal 12, 24, 48, or 130 VDC nominal Current Ratings: Continuous Rating: GROUP 1: 6, 12, 16, 20, 25 A GROUP 2: 30, 40, 50, 75, 100 A 110% rated current at maximum equalize voltage at 50 ºC (122 F) 25, 30, 40, 50, 75, 100,125, 150, 200, 250, 300, 400, 500, 600, 800, 1000 A 110% rated current at maximum equalize voltage at 50 ºC (122 F) Current Limit Adjust Range: 50% to 110% rated output 50% to 110% rated output Voltage Regulation: ±0.25% for line, load and temp. variations ±0.25% for line, load and temp. variations Electrical Noise: 32dBrnc 32dBrnc Surge Withstand Capability: Meets IEEE-472, ANSI C37.90a Meets IEEE-472, ANSI C37.90a Operating Environment: Ambient Temperature: C (0 122 F) Relative Humidity: 95% Ambient Temperature: C (0 122 F) Relative Humidity: 95% 1 AT10.1 Single-Phase Battery Charger with 12, 24, 48, 130 VDC & ADC Output 2 AT30 3-Phase Battery Charger with 12, 24, 48, 130 VDC & 25 1,000 ADC Output Battery Chargers BC-SERIES Tel: Fax: info@eepowersolutions.com V1.1 43

43 MP-1000 Modular Motive Power Battery Charger Product Overview The MP Phase Modular Battery Charger is a high frequency, fully automatic battery charger for motive power & forklift batteries. There are 15 standard configurations of the MP-1000 ranging from 24-48V and current ranges from A. Lead acid, sealed and gel traction batteries are compatible with the UL-approved MP The MP-1000 offers high-energy efficiency that reduces operating costs while the power module system eliminates costly downtime and Motive Power Battery Charger BC-SERIES MP-1000 Battery Charger Kit Includes MP-1000 Battery Charger 3 m (10 ft) Load Cable User Manual Optional: Floor Stand Product Features Soft start charge cycle Voltage drop compensation Protection against reverse polarity High frequency switching technology Charge cycle begins with batteries as low as two volts Digital display for simple programming USB Port allows programming and download of last 300 charge cycles Power module system allows charging to continue even if a module stops working Battery Voltage: Input Voltage: Battery Types: Dimensions: Standard: 24V, 36V, 48V Non-Standard: 72V, 80V 480V Lead Acid, Sealed, and Gel Traction Batteries 63.5 x 35.5 x 20 cm (25 x 14 x 8 in) 1 MP V-80A Output, 480V-4.3A Input Battery Charger (32 kg / 70 lbs) 2 MP V-100A Output, 480V-5.4A Input Battery Charger (32 kg / 70 lbs) 3 MP V-120A Output, 480V-6.4A Input Battery Charger (34 kg / 77 lbs) 4 MP V-150A Output, 480V-8A Input Battery Charger (34 kg / 77 lbs) 5 MP V-80A Output, 480V-5.4A Input Battery Charger (32 kg / 70 lbs) 6 MP V-100A Output, 480V-8A Input Battery Charger (32 kg / 70 lbs) 7 MP V-120A Output, 480V-9.6A Input Battery Charger (34 kg / 77 lbs) 8 MP V-150A Output, 480V-12A Input Battery Charger (34 kg / 77 lbs) 9 MP V-50A Output, 480V-5.4A Input Batter Charger (28 kg / 62 lbs) 10 MP V-60A Output, 480V-6.4A Input Battery Charger (32 kg / 70 lbs) 11 MP V-80A Output, 480V-8.6A Input Battery Charger (32 kg / 70 lbs) 12 MP V-100A Output, 480V-10.7A Input Battery Charger (32 kg / 70 lbs) 13 MP V-120A Output, 480V-12.9A Input Battery Charger (34 kg / 77 lbs) 14 MP V-130A Output, 480V-13.9A Input Battery Charger (34 kg / 77 lbs) 15 MP V-150A Output, 480V-16.1A Input Battery Charger (34 kg / 77 lbs) 44 Tel: Fax: info@eepowersolutions.com V1.0

44 GC-1000 High Frequency Golf Cart Battery Charger GC-1000 Golf Cart Battery Charger Product Overview The GC-1000 Golf Cart Battery Charger is a high frequency automatic battery charger for golf cart batteries. The GC-1000 is compatible with various 36V and 48V vehicle models, including E-Z-GO, Club Car, and Yamaha. The GC-1000 is lightweight, easy-to-use and can begin a charge cycle with the batteries as low as two volts. Red, Yellow and Green LED lights on the unit indicate the charging status. The float feature allows for batteries to maintain full charge at the end of a charge cycle. In addition, the GC-1000 has overload protection, and charging will be interrupted if the maximum temperature has been exceeded, protecting the batteries from over temperature and thermal runaway. Vehicle: 36V E-Z-GO 48V E-Z-GO Charger Kit Part #: Connection Cable Plug: Voltage: Universal Input: Battery Types: Vehicle Types: Display: Dimensions: Weight: Compliance: 36V / 48V V AC Standard Flooded Lead -Acid Optional: AGM or Gel 36V-E-Z-GO 48V-E-Z-GO 48V-E-Z-GO TXT 36V Club Car / Yamaha G9, G14, G16 48V Club Car Yamaha G19, G22 YDRE Yamaha LED Display: Red / Yellow / Green Lights 178 x 305 x 102 mm (7 x 12 x 4 in) 5.1 kg (11.25 lbs) UL Approved 48-E-Z-GO TXT 36V Club Car/ Yamaha G9, G14, G16 48V Club Car Yamaha G19, G22 YDRE Yamaha GC-EZ36 GC-EZ48 GC-EZTXT48 GC-CC36 GC-CC48 GC-YAM GC-YDRE Features Fully automatic battery charger for golf cart batteries Thermal cut-off and automatic overload protection Short-circuit and reverse polarity protection Begin charge cycle with batteries as low as 2 volts Float feature allows for batteries to maintain full charge at the end of charge cycle Lightweight and portable with carrying handle Kit Includes GC-1000 Main Body DC Connection Cable Plug (specific for golf cart model) User Manual Golf Cart Battery Charger BC-SERIES 1 GC-1000* High Frequency Golf Cart Battery Charger *Specify Connection Cable Type when Ordering Tel: Fax: info@eepowersolutions.com V1.0 45

45 HGD-Series Hydrogen Gas & Smoke Detectors Hydrogen Gas Detection The HGD-Series is designed for gas detection in unattended battery installations or remote shelters containing gassing lead acid batteries and charging systems. The units will turn on an exhaust fan when hydrogen gas levels reach 1% and will alarm at 2%. This alarm consists of a local 80db horn, a flashing red LED, and a dry contact switch closure for remote alarming. The HGD-3000i includes a silent intrusion alarm in addition to the standard features of the base model. For detection of only hydrogen gas, the HGD-2000 is available. Hydrogen Gas Detectors HGD-SERIES HGD-3000i Smoke Detection The photoelectric smoke sensor detects minute combustion products from smoldering wire insulation, battery cases, and other material. When smoke is detected, a distinctive alarm is emitted from the 80db horn and a separate dry contact switch is activated. At this time, the exhaust fan is inhibited in order to deny the fire increased oxygen from outside air. Temperature, Loss of Power, & Intrusion During normal operation and in the absence of an alarm condition, an internal thermostat will turn on the exhaust fan at a preset temperature to reduce heat build-up in the room. Loss of power to the unit will also generate a dry contact alarm. Additionally, an optional infrared intrusion alarm will trigger a silent dry contact switch. Features Highly sensitive and stable solid state hydrogen sensor Sensitive photoelectric smoke detector module Internal thermostat for automatic exhaust fan control at 40 C (104 F) with ±5 adjustable range Save insurance costs - reduce insurance premiums when placed in battery charging rooms Detection: Alarms: Relay Connections Mounting: Operating Environment: Power Requirements: Compliance: Dimensions: Hydrogen Gas, Smoke, Temperature, Intrusion HGD-3000: 10A Relay for Exhaust Fan, 1A Relay for Loss of Power, 1A Relay for Smoke Alarm, 1A Relay for Intrusion, 1A Relay for 2% H2 Concentration HGD-2000: (2) Form C Relay RJ45, Punch-Down Block (4) 4.5 mm (3/16 in) screws Temperature: C ( F) Standard: VAC, 50/60 Hz Optional: VDC or 12VDC IEEE Standard 450; National Fire Protection Agency (NFPA) Article 64; NFPA 2: Hydrogen Technologies Code; Uniform Building Code (UBC) Section 6400; National Electric Code (NEC) Section (A); NEC (B); NEC (1)-3 - use in Class 1 Division 2 Group B. 178 x 120 x 55 mm (7 x 4.75 x 2.5 in) 1 HGD-2000 Hydrogen Gas Detector 2 HGD-3000 Hydrogen Gas / Smoke Detector 3 HGD-3000i Hydrogen Gas / Smoke Detector with Infra-red Intrusion Alarm 4 Control Box Remote control box with connection cable for the HGD Breakout Box Breakout box for the HGD-3000 or HGD-3000i HGD-2000 Control Box Kit Includes Hydrogen Gas Detector User Manual Optional: Silent-Alarm Add-on Optional: Control Box or Breakout Box Optional: Junction Box 46 Tel: Fax: info@eepowersolutions.com V1.2

46 HGVS-1000 Hydrogen Gas Ventilation System Model # HGVS-1000 Product Overview The HGVS-1000 Hydrogen Gas Ventilation System is a forced ventilation fan system used in battery charging rooms and other areas where hydrogen may be present. This is to be used in conjunction with the HGD-2000 and HGD-3000 Hydrogen Gas Detectors. The hydrogen gas detector is mounted in the highest part of the room and the HGVS-1000 vent fan is mounted through the outside wall. HGVS-1000 Features Compliance with IEEE Std 450 Compliance with National Fire Protection Agency (NFPA) Article 64 Compliance with Uniform Building Code (UBC) Section 6400 Automatic Operation and Continuous 24/7 Monitoring High Sensitivity and Stability Long Life-Span for Reliable Monitoring Inexpensive protection for equipment and personnel Two-Year Warranty The system has four fans factory-rated at 850 CFM each. This conforms to N+1 for 2550 CFM. The vent is equipped with a Positive Airflow Shut Off feature. These doors can be closed by an external electric command, and will stop any airflow from passing through the fans. The HGVS-1000 is primarily set up to exhaust air but can be reversed to source forced air into a room. Optional Features Fan Supply Power: 24vdc, 48vdc, or 115 VAC Fan can be provided as an exhaust fan (standard) or supply fan (optional) Fan can be provided for -48 VDC A&B isolated redundant power service Fan can be provided with an optional firefighter shut down lever Fan can be provided with an optional emergency horn & flashing light Ventilation Systems VS-SEIRES Connections: Mounting: Positive Shut-Off: Dimensions: Weight: Safety Standard: Options: Input: Positive shutoff control, N.O. Dry Contacts Output: 1% Fan Running, 2% Alarm, N.O. Dry Contacts (4) 38 mm (1.5 in) Standard 607 mm (24 in) Dry contact activated, manually reset VDC or 115 VAC as ordered, ground stud Fan: 23 kg (51 lbs) Rain Shield & Damper: 10.9 kg (24 lbs) (4) fans rated at 850 CFM Total 3400 CFM N+1 (3) Fans at 850 CFM Total 2550 CFM for 777 sq. m (2550 sq. ft) Mounting wing placement, room exhaust source, small or large rain shield, N.O. to N.C., custom features on request Applications Utilities and Power Plants UPS Power Systems Fuel Cell Test Stations Nuclear Waste Reforming Hydrogen Refueling Stations Fire Department Battery Suppliers Battery Charging Rooms Motive Power Golf Cart 1 HGVS-1000 Hydrogen Gas Ventilation System (used in conjunction with HGD-2000 and HGD-3000) Tel: Fax: info@eepowersolutions.com V1.0 47

47 Critical Battery Monitoring, Testing, & Charging Solutions Battery Monitoring Portable Resistance Testing Digital Hydrometers SMART Load Testing DC Load Testing Voltage & Ground Monitoring NERC Compliance Portable Testing NERC Compliance Monitoring Thermal Runaway Monitoring Electrolyte Level Monitoring Battery Regenerators Ground Fault Location Gas Detection Data-Logging Volt Meters Battery Charging 4031 W Kiehnau Ave Milwaukee, WI phone: toll-free: fax: DISTRIBUTOR info@eepowersolutions.com * The content of this information is subject to change without prior notice for the improvement of the product s performance. V1.1

PRODUCT CATALOG YOUR PARTNER IN CRITICAL POWER SOLUTIONS

PRODUCT CATALOG YOUR PARTNER IN CRITICAL POWER SOLUTIONS PRODUCT CATALOG YOUR PARTNER IN CRITICAL POWER SOLUTIONS THE EAGLE EYE ADVANTAGE Eagle Eye Power Solutions (EEPS) mission is to lead the industry in Critical Power Solutions, Education, and Customer Support.

More information

2018 PRODUCT CATALOG YOUR PARTNER IN CRITICAL POWER SOLUTIONS

2018 PRODUCT CATALOG YOUR PARTNER IN CRITICAL POWER SOLUTIONS 2018 PRODUCT CATALOG YOUR PARTNER IN CRITICAL POWER SOLUTIONS THE EAGLE EYE ADVANTAGE Eagle Eye Power Solutions (EEPS) mission is to lead the industry in Critical Power Solutions, Education, and Customer

More information

Motive Power Solutions

Motive Power Solutions www.eepowersolutions.com Keeping an Eye on Your Critical Power! Motive Power Solutions 2016 Product Catalog ISO 9001:2008 CERTIFIED Motive Power & Forklift Battery Monitoring, Testing and Charging Solutions

More information

Station dc supply voltage. Electrolyte level. Inspect: Verify:

Station dc supply voltage. Electrolyte level. Inspect: Verify: Table 1-4(a) Component Type Protection System Station dc Supply Using Vented Lead-Acid (VLA) Batteries Protection System Station dc supply used only for non-bes interrupting devices for SPS, non-distributed

More information

Battery Monitoring Why Technology Matters. Mats Karlstrom V.P. Sales & Marketing, Alber

Battery Monitoring Why Technology Matters. Mats Karlstrom V.P. Sales & Marketing, Alber Battery Monitoring Why Technology Matters Mats Karlstrom V.P. Sales & Marketing, Alber 1 Agenda Introduction Why is battery monitoring needed? Example of battery failure Why are resistance measurements

More information

Battery Maintenance Solutions for Critical Facilities

Battery Maintenance Solutions for Critical Facilities Battery Maintenance Solutions for Critical Facilities Chapter Two: Meeting Regulatory Requirements and Observing Best Practices Click a section below In chapter one of Emerson Network Power s ebook entitled

More information

Automatic DC Power Supply/Battery Charger

Automatic DC Power Supply/Battery Charger Automatic DC Power Supply/Battery Charger PATENTED U.S. 9,270,140; 9,385,556; 9,413,186; 9,509,164 NEW in 2015: Field selectable AC input voltage in high-powered units Automatic battery commissioning mode

More information

Stationary Battery Testing

Stationary Battery Testing Stationary Battery Testing STATIONARY BATTERY TESTING The stationary backup batteries are the life line in any safety system, a life line that simply cannot fail. In order to ensure safe operation it is

More information

SENTINEL BATTERY MONITORING

SENTINEL BATTERY MONITORING Protecting your power supply SENTINEL BATTERY MONITORING Helios Power Solutions If you re operating mission critical systems and relying on the protection of a UPS and battery bank, then it has to make

More information

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER Evo Series battery charger designed with YOU in mind. Evo Series battery charger is a next generation SCR-based utility battery charger. This evolutionary

More information

Integrated Inverter/Battery Monitoring System (IBMS)

Integrated Inverter/Battery Monitoring System (IBMS) Integrated Inverter/Battery Monitoring System (IBMS) Battery monitoring at its finest Maintenance Bypass Switch Input AC to DC Converter DC to AC Inverter Static Bypass Switch Output Operations: Normal

More information

Est Battery Data Logger BDL3000

Est Battery Data Logger BDL3000 Est.1968 Battery Data Logger BDL3000 Concept The Thycon Battery Data Logger (BDL) measures, stores, displays and analyses multiple battery parameters continually without user intervention. The BDL combines

More information

Battery Monitoring System

Battery Monitoring System GE Critical Power Battery Monitoring System Battery management at its best gecriticalpower.com GE s Battery Monitoring System If you re operating mission critical systems relying on the protection of a

More information

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry

More information

Cellwatch Battery Monitoring Systems

Cellwatch Battery Monitoring Systems Cellwatch Battery Monitoring Systems A battery can fail overnight leaving an entire power system without backup capability... So what did your batteries do today? If you want to know, read on... Cellwatch

More information

Fluke 500 Series Battery Analyzers

Fluke 500 Series Battery Analyzers Fluke 500 Series Battery Analyzers Technical Data Intelligent test probe with integrated LCD display Reduced testing complexity, a simplified workflow and an intuitive user interface provide a new level

More information

RF80-M. Features. Lead Acid Batteries Multistep Programmable. Automatic Operation Stores 100 Programs

RF80-M. Features. Lead Acid Batteries Multistep Programmable. Automatic Operation Stores 100 Programs RF80-M CHRISTIE Aircraft Battery Charger / Analyzer Features Nickel Cadmium Batteries Lead Acid Batteries Multistep Programmable Automatic Operation Stores 100 Programs Unique ReFLEX Charging Exclusive

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell UPS 12-1121 PURE LEAD PLUS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications 305-545 Watts per APPLICATIONS Data Centers Network Operations Centers Industrial Process Control

More information

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features Smart-UPS On-Line Lithium Ion UPS 230V Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features A UPS developed for availability of your most critical loads under

More information

White Paper. Direct Current Load Banks for Battery Capacity Testing

White Paper. Direct Current Load Banks for Battery Capacity Testing White Paper Direct Current Load Banks for Battery Capacity Testing Direct Current Load Banks for Battery Capacity Testing Reliable Direct Current (DC) power requires battery systems to be maintained according

More information

ATevo SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative

More information

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell -11 PURE LEAD PLUS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications 305-545 Watts per Cell FEATURES & benefits APPLICATIONS Data Centers Network Operations Centers Industrial

More information

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM PowerLine DPA 20 120 kva Full power for industrial applications PowerLine DPA 20 120 kva Full power for industrial applications 2 ABB UPS SYSTEMS POWERLINE

More information

ALL-TEST PRO 5. The AT5 Motor Circuit Analyzer Complete electric motor health analysis in minutes! Motor Circuit Analyzer

ALL-TEST PRO 5. The AT5 Motor Circuit Analyzer Complete electric motor health analysis in minutes!  Motor Circuit Analyzer ALL-TEST PRO 5 Motor Circuit Analyzer PREDICTIVE MAINTENANCE QUALITY CONTROL TROUBLESHOOTING ROUTE-BASED TESTING TRENDING The AT5 Motor Circuit Analyzer Complete electric motor health analysis in minutes!

More information

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1 IMPORTANT

More information

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL 7 Stage Automatic Smart Battery Charger Desulphuration& Maintainer (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1

More information

EVO AT SERIES BATTERY CHARGER

EVO AT SERIES BATTERY CHARGER EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T PATENT PENDING hindlepowerinc.com 610-330-9000 Evo AT Series battery charger designed with YOU in mind. Evo AT Series battery charger

More information

UPS Battery Maintenance Training

UPS Battery Maintenance Training UPS Battery Maintenance Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq This UPS Battery Maintenance

More information

INTELEPOWER CXS SWITCHING SYSTEMS

INTELEPOWER CXS SWITCHING SYSTEMS INTELEPOWER CXS SWITCHING SYSTEMS INTELEPOWER CXS SWITCHING SYSTEMS Intelepower DC UPS - CXS Range Designed For Switching The demands for quality power in switching applications are placing new demands

More information

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS 12-1079 HIGH RATE MAX UPS 12-355MRF APPLICATIONS Data Centers Network Operations Centers Industrial Process Control Facilities Internet Housing Sites Semiconductor Manufacturing Banks & Financial Markets

More information

On-line, Single Phase, Double Conversion UPS

On-line, Single Phase, Double Conversion UPS V Series Standard Universal Tower/Rack Mount 1, 2, 3 kva On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven Digital Signal Processor (DSP) achieving high reliability, while

More information

AT SERIES EVO BATTERY CHARGER

AT SERIES EVO BATTERY CHARGER AT SERIES EVO BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T hindlepowerinc.com 610-330-9000 AT Series evo. A battery charger designed with YOU in mind. AT Series evo is HindlePower s next generation

More information

AT EVO SERIES BATTERY CHARGER

AT EVO SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation

More information

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA V Series 120/120VAC Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven

More information

Series 120/120VAC Universal Tower/Rack Mount

Series 120/120VAC Universal Tower/Rack Mount V Series 120/120VAC Universal Tower/Rack Mount Standard 1000VA, 1500VA, 2000VA & 3000VA LB Extended Models 900VA, 1250VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features

More information

CHAIN WEAR ANALYSIS WITH LUBECON

CHAIN WEAR ANALYSIS WITH LUBECON CHAIN WEAR ANALYSIS WITH LUBECON LUBECON THE EXPERT IN CHAIN WEAR ANALYSIS CASTROL S LUBECON BRAND OFFERS YOU A COMPLETE RANGE OF WORLD-CLASS CHAIN LUBRICANTS, LUBRICATING EQUIPMENT AND PRODUCT SUPPORT

More information

Appendix T: BATTERY REQUIREMENTS FOR INTERCONNECTION TO PG&E SYSTEM

Appendix T: BATTERY REQUIREMENTS FOR INTERCONNECTION TO PG&E SYSTEM Appendix T: BATTERY REQUIREMENTS FOR INTERCONNECTION TO PG&E SYSTEM The purpose of this document is to ensure safety and reliability of Pacific Gas and Electric Company and its customers who will or plan

More information

SECTION DC POWER SUPPLY/BATTERY CHARGER

SECTION DC POWER SUPPLY/BATTERY CHARGER SECTION 26 33 05 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide the single-phase heavy-duty industrial battery charger and all accessories required, complete and operable, in accordance

More information

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System

More information

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting

More information

INTRODUCTION MARKET SECTORS CUSTOMER SERVICE CCL OFFERS YOU. Switchmode Technology A highly efficient, lightweight

INTRODUCTION MARKET SECTORS CUSTOMER SERVICE CCL OFFERS YOU. Switchmode Technology A highly efficient, lightweight CCL OFFERS YOU Switchmode Technology A highly efficient, lightweight and compact charging technology. Providing less than 1% ripple output, this technology is especially suitable for VRLA batteries. CCL

More information

Battery Monitor Products. Trust Your Batteries TM. Doing it right!

Battery Monitor Products. Trust Your Batteries TM. Doing it right! Battery Monitor Products Trust Your Batteries TM Doing it right! www.alber.com Trust Your Batteries TM Your battery is the heart of your backup system. And just like your own heart, you don't want it to

More information

BLU SERIES Battery Load Units

BLU SERIES Battery Load Units BLU SERIES Battery Load Units Lightweight starting from 12,8 kg (28.2 lbs) Powerful discharge power of up to 28,4 kw Voltage measurement range: 5,25-500 V DC Discharge current up to 340 A DC Easily expandable

More information

SUBSTATION EQUIPMENT - Page 1 of 8

SUBSTATION EQUIPMENT - Page 1 of 8 BATTERY BANKS 1. GENERAL: JEA utilizes a 125 volt DC system for the control and operation of its transmission and distribution substations. JEA has standardized on lead acid type battery banks to supply

More information

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER DESCRIPTION Battery management is implemented in the Aspiro and Guardian DC Power Systems using the ACC Extended (ACX) controller. ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER The

More information

MJÖLNER 200 Microhmmeter

MJÖLNER 200 Microhmmeter Fully automatic testing Micro processor controlled Safe test DualGround and Remote control True DC ripple free current Lightweight suitcase withstands the impact of water, dust or sand Built in thermal

More information

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet SOLAR SMART 12/24V 20Amp MPPT Solar Charge controller with Ethernet Embedded web pages, SNMP support, output port for external Relay board and GSM SMS unit port USER MANUAL PLEASE READ THIS MANUAL CAREFULLY

More information

RF80-M. Features. Lead Acid Batteries Multistep Programmable. Automatic Operation Stores 100 Programs

RF80-M. Features. Lead Acid Batteries Multistep Programmable. Automatic Operation Stores 100 Programs RF80-M CHRISTIE Aircraft Battery Charger / Analyzer Features Nickel Cadmium Batteries Lead Acid Batteries Multistep Programmable Automatic Operation Stores 100 Programs Unique ReFLEX Charging Exclusive

More information

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible

More information

Magellan Utility Scale Energy Storage

Magellan Utility Scale Energy Storage Magellan Utility Scale Energy Storage MAGELLAN ESU 2 Supplying industry since 1992 Built for harsh environments Rugged industrial design Magellan Power ESU Series of Utility Scale Energy Storage combines

More information

ALIANT ULTRALIGHT BATTERY is a product by ELSA Solutions S.r.l

ALIANT ULTRALIGHT BATTERY is a product by ELSA Solutions S.r.l Pg. 2 / 32 LIFEPO4 BATTERY CHARGER CB1203 3 Amp charger / Xtra Small Compact and inexpensive battery charger!!! Use with Aliant X, X-P and YLP series / from 2 to 20Ah ACCESSORIES This battery charger is

More information

INTELEPOWER CX COMMUNICATIONS SYSTEMS

INTELEPOWER CX COMMUNICATIONS SYSTEMS INTELEPOWER CX COMMUNICATIONS SYSTEMS INTELEPOWER CX COMMUNICATIONS SYSTEMS Intelepower DC UPS - CX Range Designed For Communications The demands for quality power in communication applications are placing

More information

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries RS-2046 Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries FOLLOW MANUFACTURER S PUBLISHED INSTRUCTIONS WHEN INSTALLING, CHARGING AND SERVICING BATTERIES.

More information

Lithium-ion battery systems for ABB UPS solutions Reliable, lightweight and compact UPS energy storage for critical applications

Lithium-ion battery systems for ABB UPS solutions Reliable, lightweight and compact UPS energy storage for critical applications THREE-PHASE UPS SYSTEM Lithium-ion battery systems for ABB UPS solutions Reliable, lightweight and compact UPS energy storage for critical applications Lithium-ion: the choice for critical power backup

More information

Industrial Chargers and

Industrial Chargers and Industrial Chargers and DC Systems SPR - Single Phase Rectifier TPR - Three Phase Rectifier 12V 250V 5A 1000A Designed for all Industrial applications Oil & Gas, Petrochemicals Offshore, Onshore, Pipelines

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

HYBRID POWER FOR TELECOM SITES

HYBRID POWER FOR TELECOM SITES HYBRID POWER FOR TELECOM SITES ARE YOU MAKING THE MOST OF YOUR ENERGY TO REDUCE OPEX? Energy costs can amount to 55-65% of total operating expenditure for mobile operators, yet many lack the tools they

More information

ENGINEERED TO ORDER SOLUTIONS

ENGINEERED TO ORDER SOLUTIONS DM-Series ENGINEERED TO ORDER SOLUTIONS for Transformer Bushing, Winding Hot Spot and PD Monitoring Features & Benefits Advanced Analytics Flexible and Modular Hardware Platform Bushing Monitoring Optional

More information

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state

More information

80V 300Ah Lithium-ion Battery Pack Data Sheet

80V 300Ah Lithium-ion Battery Pack Data Sheet 80V 300Ah Lithium-ion Battery Pack Data Sheet 80 V, 300 amp-hour capacity, maintenance-free energy storage, IP65 design, fully integrated BMS, integrated fuse and safety relay protection, highly configurable

More information

BATTERY CHARGER Plus Battery maintainer & Rejuvenator

BATTERY CHARGER Plus Battery maintainer & Rejuvenator BATTERY CHARGER Plus Battery maintainer & Rejuvenator For lead-acid batteries \\ Model No: 60132 1 WARNING The charger is designed to charge and maintain 12 Volt batteries only. (VRLA), AGM, Calcium, Gel

More information

Portable TOC Analyser for Stack Emissions

Portable TOC Analyser for Stack Emissions Portable TOC Analyser for Stack Emissions Lightweight, compact, safe and SMART Size and Weight SPECIFICATIONS 355(W) x 155(H) x 426(D) mm, 10 Kg (with batteries 13,4 Kg) Power Supply External Power Adapter

More information

STATIONARY BATTERY SEMINAR

STATIONARY BATTERY SEMINAR Consulting Associates, Inc. Introduction & Stationary Battery Basics Page STATIONARY BATTERY SEMINAR Developed by Marco W. Migliaro, PE, Life Fellow IEEE Copyright 994-95, 00, 004, 006, 008, 0-, 04-5 by

More information

Reference Number PDS 18 - (RIC Standard: EP SP)

Reference Number PDS 18 - (RIC Standard: EP SP) Discipline Engineering Standard - NSW Category Electrical Title Reference Number PDS 18 - (RIC Standard: EP 06 00 00 01 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Jan 05 Standards

More information

RF80-K Aircraft Battery Charger / Analyzer

RF80-K Aircraft Battery Charger / Analyzer RF80-K Aircraft Battery Charger / Analyzer Features Automatic Operation Heavy Duty Design And Performance Digital Timing / Display Charges And Analyzes Aircraft Batteries (3-75 AH) One-hour Main Charge,

More information

SPA AGM VRLA batteries

SPA AGM VRLA batteries SPA AGM VRLA batteries for Stationary Applications SPA OVERVIEW Valve Regulated AGM batteries The SPA range of SUNLIGHT Valve Regulated Lead Acid batteries has been developed as general purpose batteries,

More information

Heavy-Duty Battery and Electrical System Diagnostic Tester

Heavy-Duty Battery and Electrical System Diagnostic Tester Sabre Heavy-Duty Heavy-Duty Battery and Electrical System Diagnostic Tester Heavy-duty for 24-volt battery and electrical systems Diagnoses battery packs in series, parallel, or series/parallel Test AGM/gel

More information

596 Rectifier Retrofit

596 Rectifier Retrofit PRODUCT OVERVIEW 596 Rectifier Retrofit Overview GE Energy has offered the 596 family of rectifiers from the early 1990s. 596 rectifiers can be found in the GPS4812, 2424, PXS Shelves, and OCS Cabinet

More information

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model UniStar III Series 1, 2, & 3kVA Tower Model On-line, Single-phase UPS System The UniStar III is a sophisticated yet affordable single phase, double conversion UPS system. It offers on-line technology and

More information

IEEE IAS Atlanta Chapter

IEEE IAS Atlanta Chapter Stationary Battery Sizing IEEE IAS Atlanta Chapter Presented by: Lesley Varga, P.E. Quality Standby Services, LLC 1649 Sands Place, SE, Suite C Marietta, GA 30067 (770) 916-1747 lesley@qualitystandbyservices.com

More information

BMS-3923 Battery Monitoring System

BMS-3923 Battery Monitoring System BMS-3923 Battery Monitoring System Real time knowledge about the battery condition is very significant to ensure the performance of critical power system. However, existing methods of manual measurement

More information

Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting NRG Intelligent Engine Start Battery Charger The Smart Choice for Mission-Critical Engine Starting Fast, accurate, mission-critical charging gives best starting reliability Replace nearly any charger without

More information

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog Low voltage AC drives ABB micro drives ACS55 0.25 to 3 hp/0.18 to 2.2 kw Catalog ACS55 IP20 Overview ACS55 micro drives are designed for use in a wide variety of simple machinery applications where only

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

Illuminator Series CR NEMA 3R

Illuminator Series CR NEMA 3R Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the

More information

5067 Mini BDFB / BDCBB

5067 Mini BDFB / BDCBB PRODUCT OVERVIEW 5067 Mini BDFB / BDCBB Up to 4 Loads, 600 Amps per Load Compact unit can be placed at the point of load High density models available with 48 circuits in 16RU Digital metering, extended

More information

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Series. On-line, Single-phase Parallel Redundant UPS System.   6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM Series 6 and 10 kva Rack Mount On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

Unity output power factor single-phase double-conversion, online UPS with advanced management features

Unity output power factor single-phase double-conversion, online UPS with advanced management features Smart-UPS On-Line 208V Unity output power factor single-phase double-conversion, online UPS with advanced management features A versatile UPS developed for unstable power conditions worldwide. Smart-UPS

More information

User Manual. Hybrid PV Inverter. Version: 2.1

User Manual. Hybrid PV Inverter. Version: 2.1 User Manual Hybrid PV Inverter Version: 2.1 Table Of Contents 1. Introduction...1 2. Important Safety Warning...2 3. Unpacking & Overview...4 3-1. Packing List... 4 3-2. Product Overview... 4 4. Installation...5

More information

engineered to order solutions

engineered to order solutions DM-Series engineered to order solutions for Transformer Bushing and Partial Discharge (PD) Monitoring Features & Benefits Bushing Monitoring Partial Discharge Monitoring Optional Thermal Modelling with

More information

ANNEXURE XI. (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I.

ANNEXURE XI. (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I. ANNEXURE XI (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I. Sr. No Technical Particulars Confirmation to be given by bidder (Please strike out which ever not applicable)

More information

ABB Services for Low Voltage equipment Your choice, your future

ABB Services for Low Voltage equipment Your choice, your future ABB Services for Low Voltage equipment Your choice, your future You choose, we respond. Globally. The future of your equipment depends on the service you choose Whatever you choose, it should be a well-informed

More information

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System Illuminator Series CM GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System This description contains all the necessary functional and technical

More information

Li-ion Battery System

Li-ion Battery System Flex ion TM Li-ion Battery System For Mission Critical Applications DATA CENTERS OIL & GAS UTILITY Flex ion TM main advantages Main benefits versus VRLA lead-acid batteries LIFE TIME LOW MAINTENANCE INSTALLATION

More information

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller Rover Series Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller 0 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.5 Important Safety Instructions Please save these

More information

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C)

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C) 12-373 UL Recognized Component RETURN LEAD RECYCLE LIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY FOR STANDBY APPLICATIONS Capacities from 100 to 600 Ampere-hours (8 hours to 1.75 VPC) 343 to

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

Solution Overview. Asset Condition Monitoring. Extend operational life and reduce downtime

Solution Overview. Asset Condition Monitoring. Extend operational life and reduce downtime Solution Overview Asset Condition Monitoring Extend operational life and reduce downtime QUALITROL Integrated Monitoring Server : Data Integration Diagram SMARTSUB Substation Condition Monitoring: Transformer

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

Testing Lead-acid fire panel batteries

Testing Lead-acid fire panel batteries Thames House, 29 Thames Street Kingston upon Thames, Surrey, KT1 1PH Phone: +44 (0) 8549 5855 Website: www.fia.uk.com Testing Lead-acid fire panel batteries 1. Background - Methods of testing batteries

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. IntelliCharge Battery Charger Series INSTRUCTION MANUAL 855-342-000 Models: ICT24012-30BC2, ICT24012-30BC2M ICT24012-15BC2, ICT24012-15BC2M ICT24024-15BC2, ICT24024-15BC2M

More information

CBI All in One DC UPS Power Solutions

CBI All in One DC UPS Power Solutions CBI All in One Power Solutions Everything and more! More efficiency of the battery thanks to continuous control over time. More monitoring in main connection nodes: input, output load, battery. Event logging:

More information

SimpliPhi Power PHI Battery

SimpliPhi Power PHI Battery Power. On Your Terms. SimpliPhi Power PHI Battery INTEGRATION GUIDE: VICTRON Optimized Energy Storage & Management for Residential & Commercial Applications Utilizing Efficient, Safe, Non-Toxic, Energy

More information

Stationary Batteries: Why they fail and what can be done to prolong battery life

Stationary Batteries: Why they fail and what can be done to prolong battery life Stationary Batteries: Why they fail and what can be done to prolong battery life J. Allen Byrne Tech. Support & Services Mgr. Interstate PowerCare A Division of Interstate Batteries April 13, 2016 Schaumburg,

More information

BLU SERIES Battery Load Units

BLU SERIES Battery Load Units BLU SERIES Battery Load Units Lightweight starting from 12,8 kg (28.2 lbs) Powerful discharge power of up to 28,4 kw Voltage measurement range: 5,25-500 V DC Discharge current up to 340 A DC Easily expandable

More information

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous

More information

CENTURY YUASA - STANDBY OVERVIEW

CENTURY YUASA - STANDBY OVERVIEW CENTURY YUASA - STANDBY OVERVIEW BUSINESS OVERVIEW Overview Our People Standby Power Division is a group within CenturyYuasa that provides Across Australia, Century Yuasa Field Technicians have wide energy

More information

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations DLRO 10 and DLRO 10X DESCRIPTION NEW interchangeable test lead terminations Auto current reversal cancels standing emfs Protected to 600 V Automatically detects continuity in potential and current connections