Similar documents
Continental Super Flow

INSTALLATION INSTRUCTIONS

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

INSTALLATION INSTRUCTIONS

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Electromagnetic Particle Clutches and Brakes Models: POC, PHC-R, PMC-A3, POB, PRB and PTB-BL3 P Performance Manual

WARNING. Laser light is extremely bright and can potentially cause permanent eye damage or interfere with critical operations if improperly used.

OWNERS MANUAL HF4263

Electromagnetic Particle Brakes Model: PRB-H

Premium Supply. Tilt Deck. Models PCK-TD PCK-PTD. Operator s Manual and Installation Instructions

FLEETWOOD TRAVEL TRAILER SLIDEOUT SYSTEM OWNER S MANUAL

TRI-GRAIN MOISTURE TESTER OVVNER'S MANUAL

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

Installation Instructions

Premium Supply. Tilt Deck. Models PCK-TD PCK-PTD CTD-310-K. Operator s Manual and Installation Instructions

Users Guide for Ac-sync

MODEL TC400 TIRE CART. Installation, Operation & Repair Parts Information REV P/N:

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

SOLAR DASH CHARGING SYSTEM USER GUIDE

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Installation Instructions / Warranty

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

Premium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions

2 HP PADDLE WHEEL AERATOR

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Owner s Manual & Safety Instructions

AT Clutch Major Service Sizes 25, 55, 115

Service & Installation Instructions. An Altra Industrial Motion Company P WE Vented. Enclosed Version Optional

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

Preassembled Clutch/Electrically Released Brake Module

OWNERS MANUAL HF4550 PREACHER CURL. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

OWNERS MANUAL HF4261

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

Preassembled Clutch/Brake Module

Compressor Clutch Replacement Procedure

OWNERS MANUAL HF

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Preassembled Clutch/Electrically Released Brake Module

ERD Electrically Released Brakes

Quadratec Spare Tire Mounted Bike Rack

Warner Electric UNIBRAKE Motor Brakes

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

Installation Instructions Pet Barrier

J. & M. Mfg. Co., Inc. 284 Railroad Street - P.O. Box 547 Fort Recovery, OH Ph: (419) Fax: (419)

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Stainless Steel Air Motor Conversion Kits

9' & 12' CHALLENGER SHUFFLEBOARD TABLE ASSEMBLY INSTRUCTIONS

Installation Instructions / Warranty. Starck 10444XX XX1

POWER GEAR SLIDE-OUT MANUAL

Procedure to Install the New Autogap components in ER-1225 and ER825 Brake with inverted Armature Hub

RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS

ROW PRO DOWN PRESSURE

QUALITY MISTING PUMPS

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

Installation Power Management Unit Battery Cables and Battery Harness

Instruction Manual. ATV Plow Tube System

SELECT/DIRECT DEMO BOX USER GUIDE. INST164 Doc 1.00

Wrap Spring Clutches & Brakes CB & Super CB Series P-2026-WE SM592-gb-02/08

QUALITY MISTING PUMPS

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

User s Manual and Operating Instructions

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

Extension Boot System

Installation Instructions Receiver Rack (Part # 7700) Universal Application

Case IH 3320, 3330, and Booms AutoBoom Installation Manual. P/N Rev B 06/15

Two Motor Tandem. Installation Instructions. for Model 108 F LEX-AUGER Feed Delivery Systems

HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS

Stainless Steel Air Motor Conversion Kits

Compressor Clutch Replacement Procedure

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

Lint Slide Grid Moist Air Applicator

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

Installation Instructions / Warranty

FR1118- P10. User s Manual

Installation Instructions

Extension Hopper Installation & Operator s Instruction Manual for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

Table of Contents. Safety... 2 Specifications... 3 Setup Parts List and Diagram Warranty Operation Maintenance

PPM EO-100 TM. Operation Manual

Water Jetter Units DU JT50 / DU JT100

30Deg.Two Motor Tandem

CDS-JOHN BLUE COMPANY

LED 3rd Brake Light Ring

Harvil 4 Foot Air Hockey Table

FOLD SEQUENCE VERSION 2 & 3 ISO 6. Operator s Manual FOLD 1 FOLD 2 FOLD 3 FOLD 4 FOLD 5 FOLD 6 FOLD 7 FOLD 8 IMP-LIFT DISC COULTER MARKER

DeZURIK 2 20" BOS BUTTERFLY VALVES

TRUSS KITS FOR SPOUTING Installation Manual

11 ½" MODEL SINGLE CHAIN CONVEYOR

Quadratec 2 or 4 Bike Receiver Bike Racks

Read this entire manual before operation begins.

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Transcription:

Safety Notices... 1... 3 Specifications... 3 General... 3 Electrical... 3 Hydraulic Connections... 3 Components... 4 Assembly... 4 Implement Installation... 7 Hydraulic Connections... 9 Closed-Center Hydraulics... 9 Connecting Multiple s (Closed-Center Hydraulics)... 9 Open-Center Hydraulics... 11 Pre-check... 13 Manual Override... 13 Warranty...15 /I

II /

SAFETY NOTICES Safety notices are one of the primary ways to call attention to potential hazards. This Safety Alert Symbol identifies important safety messages in this manual. When you see this symbol, carefully read the message that follows. Be alert to the possibility of personal injury or death. Use of the word WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Use of the word CAUTION with the Safety Alert Symbol indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Use of the word CAUTION without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in equipment damage. SAFETY NOTICES / 1

2 / SAFETY NOTICES

HYDRADRIVE The is a hydraulic motor with an integrated flow control valve that delivers high torque at low speeds while consuming minimal hydraulic oil. Hydraulic ports on the drives allow multiple s to be connected. SPECIFICATIONS GENERAL RPM Operating Range: 4 to 180 RPM Hydraulic Oil Usage: 4.9 in 3/rev (80 cc/rev) Max Hydraulic Oil Usage: 4 gpm (15 LPM) Maximum Torque: 1400 inch pounds (160 Nm) Dimensions: 10.2 x 5.0 x 6.3 in (260 x 127 x160 mm) Weight: 19.8 lbs (9.0 Kg) ELECTRICAL Control Signal: 12 Volts pulse width modulated Control Frequency: 200 Hz Maximum Current: 1.5 Amps HYDRAULIC CONNECTIONS Tractor Hydraulics: Closed Center or Open Center Hydraulics: Pressure port 1/2 SAE (7/8 UNO) Return port 1/2 SAE (7/8 UNO) HYDRADRIVE / 3

COMPONENTS components consist of the following items that must be assembled prior to installation. Hydraulic motor Valve manifold Valve cartridge (4) bolts A bracket will be required to attach the to the implement. Figure 1 Components Valve Manifold 4 Bolts ASSEMBLY Valve Cartridge Hydraulic Motor The mounting position of the manifold onto the motor will affect: Direction the motor will turn (clockwise or counterclockwise). The motor direction is identified on the type and bottom of the manifold. Pressure and return inlets To Assemble the : 1. Remove the red blocking s from the hydraulic motor and verify o-rings are fitted within the pressure and return inlets. IMPORTANT: Ensure the hydraulic motor mounting surface is clean with no dust particles before attaching to the manifold. 4 / HYDRADRIVE

Figure 2 Verify O-rings Remove s and verify o-rings are in place Remove s and verify o-rings are in place Mounting of the manifold determines which direction the motor will turn. Motor direction is identified on the top and bottom of the manifold. Figure 3 Secure Manifold to Motor Align valve to motor. Insert bolts to secure placement. 2. Determine the appropriate motor direction and align the valve manifold mounting holes to the hydraulic motor. 3. Insert bolts into manifold holes and use an Allen wrench to tighten and secure to motor. HYDRADRIVE / 5

4. Place the valve cartridge into the side hole of the valve manifold and screw in until secure. Figure 4 Valve Cartridge Placement The motor is now ready to install to implement. Figure 5 Assembled 6 / HYDRADRIVE

IMPLEMENT INSTALLATION To attach the to the implement, a heavy-duty bracket is required either by making or purchasing from a dealer or distributor. The typical mounting location is the center of the implement above the final planter drive. To Install to the Implement: 1. Attach steel bracket to implement frame to accommodate mounting of. 2. Mount the to the bracket. 3. Attach appropriate drive sprocket on the 1 keyed output shaft of the. 4. Install application rate sensor and coupler onto the 1 output shaft of the. Figure 6 Bracket Mounted to Implement Drive Sprocket Application Rate Sensor Coupler Bracket Mounting Holes IMPLEMENT INSTALLATION / 7

8 / IMPLEMENT INSTALLATION

HYDRAULIC CONNECTIONS The is connected to the tractor hydraulics and is dependent on if the tractor has closed-center or open-center hydraulics. The is shipped for closed-center hydraulics. Check the tractor s operator s manual to confirm the tractor s hydraulic type. NOTE: All pressure and return ports on the are SAE #10. CLOSED-CENTER HYDRAULICS For closed-center hydraulic connections to the valve, connect as shown in (Figure 7). 1. Connect hydraulic pressure hose from tractor to P1 valve port. 2. Connect hydraulic return hose from T1 valve port to tractor. 3. Close the P2 and T2 ports with the red blocking s. Figure 7 Closed-Center Connection Hydraulic pressure from tractor Hydraulic pressure to tractor CONNECTING MULTIPLE HYDRADRIVES (CLOSED-CENTER HYDRAULICS) Ports P2 and T2 are used only when connecting multiple s in a series. 1. Connect hydraulic pressure hose from tractor to P1 valve port. 2. Connect a hose from the P2 valve port to the P1 valve port of the next. 3. Connect a hose from the T2 valve port to the T1 valve port of the next. 4. Repeat steps 2 and 3 for each connected unit. 5. Connect the hydraulic return hose of the last connected to the T2 port back to tractor. 6. Close the P2 port of the last connected using the red blocking. Close the T1 port on the first using the red blocking. HYDRAULIC CONNECTIONS / 9

Figure 8 Connecting Multiple Units (Closed Center) Hydraulic pressure from tractor Hydraulic return to tractor 10 / HYDRAULIC CONNECTIONS

OPEN-CENTER HYDRAULICS For an open-center hydraulic connection to the valve, connect as shown in (Figure 9). 1. Remove the 5 mm hex blocking 5. 2. Under 5 remove the 4 mm hex blocking. This is to be permanently removed. 3. Reinstall the outer blocking 5. 4. Connect hydraulic pressure hose from tractor to P1 valve port. 5. Connect the hydraulic return hose to the T2 port. 6. Close the P2 and T1 valve ports with the red blocking s. Figure 9 Open-Center Connection Hydraulic pressure from tractor Permanently remove 4mm blocking. Re-install outer blocking. Hydraulic pressure to tractor CONNECTING MULTIPLE HYDRADRIVES (OPEN-CENTER HYDRAULICS) To connect multiple units: 1. Remove the 5 mm hex blocking 5. 2. Under 5 remove the 4 mm hex blocking. This is to be permanently removed. 3. Reinstall the outer blocking 5. 4. Connect hydraulic pressure hose from tractor to P1 valve port. 5. Connect a hose to the T2 valve port and connect to the next unit s P1 valve port. 6. Repeat steps 1-3 and step 5 for each unit. 7. Connect the hydraulic return to tank hose to the T2 valve port of the last unit back to tractor. 8. Close all P2 and T1 valve ports with red blocking s on each unit. HYDRAULIC CONNECTIONS / 11

Figure 10 Connecting Multiple Units (Open Center) Permanently remove 4mm blocking. Re-install outer blocking. Hydraulic pressure from tractor Hydraulic return to tractor 12 / HYDRAULIC CONNECTIONS

PRE-CHECK A pre-check before connecting to the controller is recommended to verify: Hydraulic hoses are properly connected Motor rotates in the right direction MANUAL OVERRIDE A manual override of the hydraulic valve will verify proper installation. To manually override the hydraulic valve: 1. Start tractor and engage hydraulics. 2. Unscrew the protective cap from the valve cartridge. 3. Slowly turn the red thumbscrew clockwise to a maximum of 4 1/2 turns to fully open the hydraulic valve. 4. Verify that the hydraulic motor is rotating in the proper direction. A After performing a manual override, the red thumbscrew on the valve cartridge MUST be turned fully counter clockwise until it stops turning for automatic control of the valve. Figure 11 Valve Cartridge Thumbscrew Thumbscrew HYDRAULIC CONNECTIONS / 13

14 / HYDRAULIC CONNECTIONS

Dealers have the responsibility of calling to the attention of their customers the following warranty prior to acceptance of an order from their customer for any DICKEY-john product. DICKEY-john WARRANTY DICKEY-john warrants to the original purchaser for use that, if any part of the product proves to be defective in material or workmanship within one year from date of original installation, and is returned to DICKEY-john within 30 days after such defect is discovered, DICKEY-john will (at our option) either replace or repair said part. This warranty does not apply to damage resulting from misuse, neglect, accident, or improper installation or maintenance; any expenses or liability for repairs made by outside parties without DICKEY-john s written consent; damage to any associated equipment; or lost profits or special damages. Said part will not be considered defective if it substantially fulfills the performance expectations. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY, FITNESS FOR PURPOSE, AND OF ANY OTHER TYPE, WHETHER EXPRESS OR IMPLIED. DICKEY-john neither assumes nor authorizes anyone to assume for it any other obligation or liability in connection with said part and will not be liable for consequential damages. Purchaser accepts these terms and warranty limitations unless the product is returned within fifteen days for full refund of purchase price. For DICKEY- john Service Department, call 1-800-637-3302 in either the U.S.A. or Canada Headquarters: 5200 Dickey-john Road, Auburn, IL USA 62615 TEL: 217 438 3371, FAX: 217 438 6012, WEB: www.dickey-john.com Europe: DICKEY-john Europe S.A.S, 165, boulevard de Valmy, 92706 Colombes France TEL: 33 (0) 1 41 19 21 80, FAX: 33 (0) 1 47 86 00 07 WEB: www.dickey-john.com 2017 DICKEY-john Specifications subject to change without notice.