Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

Similar documents
Quick Setup Guide for IntelliAg Model YP Air Pro

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Population pre-def ned Every Row Population. For other pre-def ned are made to the system or if options are added to the base planter.

Quick Setup Guide for IntelliAg Model YP Twin Row

Quick Setup Guide for IntelliAg Model YP

Full screen alarms identify abnormal or failed operation on all enabled system components/controls

ROW PRO DOWN PRESSURE

CONTROL SYSTEMS FOR PRECISION FARMING. IntelliAg puts the future of application control in your cab providing state-ofthe-art

Planting. Press to Highlight Configuration. Gauge Wheel Load Alarm. Value must be entered for your specific planter and parallel arm combination

CONTENTS 1.0 INTRODUCTION SAFETY... 5

Manufacturing, Inc.

FOLD SEQUENCE VERSION 2 & 3 ISO 6. Operator s Manual FOLD 1 FOLD 2 FOLD 3 FOLD 4 FOLD 5 FOLD 6 FOLD 7 FOLD 8 IMP-LIFT DISC COULTER MARKER

Reference Manual /12

CFX-750 Display with the Field-IQ System: Spraying /Strip Till/Anhydrous Application Quick Reference Card

Installation Instructions ISOBUS Liquid ECU

WIRELESS BLOCKAGE MONITOR OPERATOR S MANUAL

HARRISTON PICK POTATO PLANTER

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00

Troubleshooting a Planter that applies above or below target rate

Seed and Fertilizer Rate Charts for the YP1625IR Yield-Pro Planter with Individual Row Control Meters

Seed and Fertilizer Rate Charts for the YP3025A, YP4025A and YP4425A 30, 40 and 44-Foot 3-Section Yield-Pro Planters with Air-Pro seed meters

2010 AIR SYSTEM OWNERS OPERATING & PARTS MANUAL 2800 & 3350

Calibration & Operation Manual

Setup Tabs. Basic Setup: Advanced Setup:

ADJUSTMENTS BEFORE GOING TO THE FIELD

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual

Flight Systems. Replacement for KASSEC DESCRIPTION

PROPORTIONAL BAND ZERO ENERGY BAND DEFINITION S1 S2

Application Engineering

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE

AGRICULTURAL 2019 PARTS CATALOG

Signet Temperature Transmitter

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

Clutch Control. PN: November 2013 Rev E 1

CS 430RC. Solid De-icer Controller Configuration and Set-up Manual

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

Operator s Manual. Wi-Fi Air Drill Rate and Blockage ECU. MNST08205 P a g e 1 Software Revision 2.3.0

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

Raven RS1 Guidance and Steering Calibration & Operation Manual. P/N Rev. A 09/17 E29677

Signet Pressure Transmitter

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

ECONOMISER SERIES E2T USER MANUAL

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications

An ISO 9001:2008 Registered Company

Seed-Squirter. Installation Guide. APPLICATION SYSTEMS FOR PROFESSIONALS. How Can We Help?

SIGNET Temperature Transmitter

Freeman 380/385 Hydro PTO Operator Controls and Baler Connection Instructions

Spray Height Controller

KONGSKILDE KONNECT 1000

MODEL MCL-3212 SPEEDOMETER/TACHOMETER for 2012 up Dyna and Softail with 4 gauge

Smart Screen Operator Interface

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

INSTALLATION GUIDE Table of Contents

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

LED Diagnostic Display. ABS Modulator. Connector (MOD1) Supply Port 1/2" NPT MC-30 CONTROLLER INTRODUCTION

Matrix Pro GS. Setup Guide. For use with software version 3.0x. TeeJet Aabybro Mølhavevej 2 DK 9440 Aabybro Danmark

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

Level-Up Motorhome Leveling

RADION Automatic sprayer control Software version 1.07

PH2 C50219A AIR INTAKE SHUT-OFF VALVE. T800 KENWORTH / ISX ENGINE WITH POWERGUARD SMART OVERSPEED LIMITER

Instructions for Micro-Trak Seed Rate Control Systems Used with AgLeader INSIGHT, INTEGRA One, Two and Three Section

International A26 (2017)

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev.

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6.

Gillig EFAN Diagnostic Software User Guide & Troubleshooting Guide 8A Rev H Last Revised: 3/23/2017

KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS

MaxxForce 11 and 13 ( )

Diagnostic Trouble Code (DTC) List

Signet Pressure Transmitter

MONITOR INSTALLATION AND OPERATING INSTRUCTIONS VERSION

CurveMaker DFS v2.0 Dyna FS Ignition Programming Software

Issue 2.0 December EPAS Midi User Manual EPAS35

SureFire Drives and Harnesses for use with John Deere Dry Rate Controller

SharpShooter With Rate Sync for Turf

OMEM200 Tuning Manual 3v Series ECU. Tuning Manual OMEM200.

B-RAD Select USER MANUAL TABLE OF CONTENTS

Device Description User Manual Logix MD+ Positioners with HART

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

MODEL MCL /8 SPEEDOMETER/TACHOMETER for 2004 up

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Advanced User Manual

TOPCON APOLLO ISOBUS SEEDER CONTROLLER OPERATOR S MANUAL

DICKEY-john Sales DICKEY-john Technical Support

Subject Underhood G System Error Codes and Symptoms System or Parts affected

CONTROLLER DIAGNOSTIC GUIDE

B-PC20 Power Close Module

Seed and Liquid Fertilizer Rate Charts for the YP2425 and YP2425F Planters

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Service Manual. For the SCV2832E, SCV2426, Automatic Scrubbers For: Training Troubleshooting

Product Overview. Shift light turns on when RPM is above programmed shift point. Stage 2 activation light turns on when Stage 2 is active.

SmartFOAM. Electronic Foam Proportioning Systems. Models: Class A only 1.7AHP, 2.1A Class A/B 3.3, 5.0, 6.5 FOAM OPERATION QUICKSTART FSG-MNL-00179

Installation Instructions

2007 Mercury Marine SmartCraft Gauges

USERS MANUAL MCD REMOTE OPERATOR

BLOCKAGE MONITOR. Proudly built in the U.S.A. by:

Vission 20/20 micro-controller. Operation and service manual

ECON-ZIP-DETF; ZIP PACK

Seed Rate Charts for the YP1225 or YP1625 Planters

Transcription:

STEP 1: Pre-Programming Preparation: Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings. If errors are detected (e.g., failed sensors, incorrect confi guration) an alarm and code displays. Alarms are silenced by pressing the Alarm Cancel button. Refer to Operator s manual for troubleshooting assistance. The system has three user levels. The system loads in User Level 1 (operator level) at every power cycle. Access to User Level 2 and 3 screens to setup constants (system confi guration) requires a password. STEP 2: Change User Level to Dealer Level To change the user level, a 6-digit password is required. Password includes the five-digit serial number found on the label of the Working Set Master or Information screen. On the IntelliAg Main Work screen, press the Diagnostics button. At the Diagnostics screen, press the Information button. At the Information screen, record serial number of WSMT. Press the Password button. On the Password screen, enter the 6 digit password as follows: enter the fi rst digit as 2 for User Level For the next fi ve digits, enter the Working Set Master serial number taken from the WSMT or Information screen. 6. Press the OK button. Dealer screens on appears at the bottom of screen confi rming the password and dealer screens are activated. 7. Press the Work Screen button to return to the Main Work screen. STEP 3: Auto Configuration (Identifies sensors connected to each module) Auto config is performed at the factory, but may need to be done in the field as changes are made to the system or if options are added to the base planter. Verify Auto Confi g results are correct. Check that the correct number of rows are assigned to the correct module and number of hopper sensors are assigned accurately. To Run Auto Config: Press the Next Page button until the Confi guration button appears. Press the Confi guration button. Press the AUTO CONFIG button. Hour glass will indicate system is being confi gured detecting the presence of seed or hopper sensors connected to each module and will be automatically assigned to the appropriate module. When Auto Confi g completes, press the Row Assign button to display the Row Assignment screen to verify correct Row # is assigned to the correct module based on serial number. 6. Enter # of rows assigned to each module. Configuration Screen Seed Sensor Configuration Screen STEP 4: Row Status/Row Width At the Row Assignment screen, press the Row I/O button. Begin entering desired values using Table A as reference. Press the Work Screen button when Row Status/Row Width confi gurations are complete to return to the Main Work screen. STEP 5A: Material Configuration (Controlled Hydraulic Drive) 15 different materials can be confi gured for use as planter controls. Reference the System Confi guration section in the Operator s manual for additional information. At the Main Menu screen, press the Control button. Select and press one of the Material buttons (Material 1-15). Enter desired values from Table B. 6. (Optional) SERIAL NUMBER 10001 10001 10002 10003 10001 MODULE TYPE WSMB-18R MODULE ADDR. 1 WSMT-PDCGP 2 WSMB-18R 3 WSMB-POM 4 WSMB-CFM 5 Press the Control button to return to the Control screen. Repeat steps 2-4 for additional materials. Press the Channel button to proceed to channel setup screen. MODULE ADDR. TYPE 1 WSMB-18R The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference Operator s manual for installation instructions. NOTE: The master switch is only required for hydraulic control systems. Reference the manual for instructions to assign a master switch as an auxiliary input. 2 WSMT- PDCGP 6 # OF ROWS ROW # s 3 1-3 4-9 3 WSMB-18R 3 10-12 TABLE A: Row Status/Row Width TABLE B: Material Default Value/ Value to Enter Controlled Hydraulic Drive Matrl Label Matrl 1 Material Name can be customized to accurately defi ne the material s type. Creating a name allows for quick identifi cation at the Control screen. Type Planter Control Desired type of application control channel being used for a specifi c material. The Material Type must correctly match the Control Type to be able to select Material from the Material Summary screen and operate properly. Units Ks/Ac S/Sec Automatically changes with the type of material application selected. Changes units for target application. Preset Method Enable Enabled Preset Method allows 10 user-defi ned target rates to be adjusted from the Main Work screen using Inc or Dec buttons. A Disabled Preset Method increases/decreases the target rate based on the % values set at the Material screen. Seeds per Rev See Manual Set to number of seeds per 1 disc revolution. Disc Low Limit 5 Set to desired min seed disc RPM. Disc High Limit 37 Set to desired max seed disc RPM. Product Level Alarm Sets the level to trigger an alarm alerting of low product levels. Entered value is an estimate in volume. High Pop Alarm 15% This is the percentage above the target population of the planter channel if rows are assigned to the planter channel. If rows are not assigned to a planter, this is the percentage above average planter population for all unassigned rows. Low Pop Alarm 15% This is the percentage below the target population of the planter channel if rows are assigned to the planter channel. If rows are not assigned to a planter channel, this is the percentage below average planter population for all unassigned rows. Row Fail Rate Default Value or Value to Enter 2/1 (2 seeds every 1 second) Row Width 36 Enter row width distance in inches to calculate seed rate 38 40 correctly. Auto Update Width Enabled When enabled, implement width will automatically calculate. If disabled, manually enter implement width. On/Off Pattern Every Row On On/Off Pattern indicates specifi c row patterns to be on or off. Select pre-defi ned planter All Row On pattern. For other pre-defi ned planter patterns or individual row settings, reference Operator s manual. Pop/Block Pattern Every Row Population Determines which sensors are used to calculate population and those used only for blockage detection. Select pre-defi ned Every Row Population. For other pre-defi ned patterns, reference Operator s manual. Set to desired number of seeds per second to trigger seed sensor failure alarm. 1

STEP 5B: Material Configuration (Ground Driven Metering) For Ground Driven Metering, control channels 1, 3, and 4 MUST be disabled and the Monitor Only feature selected at the Control screen. NOTE: A Material Name must also be selected at the Row Monitor screen to activate high and low population alarms. At the Main Menu screen, press the Control button. Select and press one of the Material buttons (Material 1-16). Enter desired values from Table B Press the Control button to return to Control screen. Press the Channel button to proceed to Channel screens and disable any active channels. STEP 6A: Planter Control Channel (Controlled Hydraulic Drive) At the Control screen, press the Channel button. Select Channel 1 and verify that the channel is set to Planter Control. Enter desired values using Table C as reference. After planter control setup, calibrate hydraulic valve by pressing the Valve Cal button. Ensure implement is raised. With brakes locked and transmission in PARK position, start engine. 6. Engage hydraulics and run engine at normal speed until hydraulic fl uid is at operating temperature. 7. 8. Verify point row clutches are turned ON. Do NOT perform this step unless meters are installed in all locations across planter row units or drive damage will occur. Press the START button. Turn the master switch to the ON position. The valve calibration will immediately start. Keep the hydraulics engaged until the calibration completes. 9. When the screen indicates calibration is complete, press the Channel button to return to Channel 1 home screen. 10. Turn the master switch OFF. 1 To set up additional control channels (planter or fertilizer control), press the Next Channel button. 1 Press the Work Screen button when channel confi gurations are complete to return to the Main Work screen. Once a control channel has been established as Planter Control, any new materials established as Planter Control on the Material screen will automatically be added as optional materials for Planter Control channels on the Control screen. STEP 6B: Planter Control Channel (Ground Driven Metering) NOTE: When using a ground drive/nonhydraulic application to monitor population, control channels 1, 3, and 4 must be disabled and Material configured for Monitor Only. A Material Name must also be selected at the Row Monitor screen. At the Control screen, press the Channel button. Select Channel 1 and verify that the channel is set to Disabled. Press the Next Channel button to change all other control channels to Disabled. TABLE B2: Material TABLE C: Planter Control Default Value/ Value to Enter Default Value/ Value to Enter Ground Driven Metering Type Monitor Only Desired type of application control channel being used for a specifi c material. Units Target Population High Pop Alarm Low Pop Alarm On/Off Pattern Row Fail Rate Ks/Ac S/Sec 2/1 (2 seeds every 1 second) Automatically changes with the type of material application selected. Changes units for target application. Desired rate of application Warns of a high population problem. Values are % based. Warns of a low population problem. Values are % based. Rows can be automatically turned ON or OFF according to the pattern. Set to desired number of seeds per second to trigger seed sensor failure alarm. Type Planter Control Set desired Channel Type as Planter Control. Material Name Displays only materials that have been confi gured for the channel type. Control Mode AUTO Auto is used in normal operating conditions calculating the rate of how the system is running. Manual mode acts as an override if application rate sensors are inoperable allowing the use of increase/decrease buttons to set the fl ow rate for the control. Refer to System Confi guration section of Operator s manual for additional information. Drive Type PWM A hydraulic valve varies the oil fl ow to the motor proportioned to the electric current supplied. Drive Frequency 100 Hz If not using a DICKEY-john supplied valve, see the manufacturer s specifi - cations for drive frequency. Input Filter 50 Feedback frequency fi lter for the control channel. DO NOT CHANGE. Gear Ratio 900 Specifys the actual ratio from the feedback sensor to the seed meter shaft RPM. Number of revolutions the feedback sensor turns in relation to one revolution the seed meter turns. Sensor Constant 360 Sensor Constant establishes the number of pulses for one revolution of the feedback sensor. If a DICKEY-john application rate sensor is used, the value should be set to 360.0. # of Seed Rows 12 Entry of a specifi c number of seed rows for the control channel. Row assignment is given a priority based on the channel and will be assigned sequentially thereafter. Channel 1 is always assigned to the fi rst set of rows, Channel 2 next set of rows, and so on. Channel Width 432 456 480 Manual entry of the channel width for rows assigned to a specifi c channel. Width calculation can be determined by # of planter rows assigned to the channel multipled by the row spacing. Precharge Time + 0.0 Typically used during startup conditions in the fi eld, a Precharge time is a specifi ed length of time a control channel will operate at the defi ned Precharge Ground Speed. Must be entered as a positive (+) number. Delay Time - 0.0 Length of time before the control channel will start after the master switch has been turned ON and the implement switch is in a lowered position. Must be entered as a negative (-) number. 2

STEP 7A: Material Configuration (Split Air Regulation) It is recommended that when setting a control channel for split air, the material name be created as Air to eliminate confusion between the actual material and the control used. At the Main Menu screen, press the Control button. Select the Material 16 button. Enter desired values from Table D. Press the Work Screen button to return to the Main Work screen. TABLE D: Material Default Value/ Value to Enter Split Air Regulation Type Split Air Reg Desired type of application control channel being used for a specifi c material. CREATE MATERIAL NAME AS AIR. Units In H 2 0 Oz in 2 Automatically changes with the type of material application selected. Changes units for target application. Preset Method Disabled User-defi ned target rates can be confi gured and when enabled can be adjusted from the Main Work screen using the Increment/Decrement buttons. Target Rate 00 Establishes the desired rate of application in inches of H 2 0. Max Rate 00 Maximum application rate in inches of H 2 0. Min Rate 00 Minimum application rate in inches of H 2 0. Inc/Dec % 5% Percentage of change of the entered target rate applied each time the Increment/Decrement button is pressed on the Main Work screen. STEP 7B: Planter Control Channel (Split Air Regulation) NOTE: Split Air Regulation must be configured as Control Channel 2 only. At the Control screen, press the Channel button. Select Channel 2 and select Split Air Regulation as the Type. Enter desired values from Table E. Press the Work Screen button to return to the Main Work screen. TABLE E: Planter Control Default Value/Value to Enter Split Air Regulation Type Split Air Reg Confi gure control channel 2 as Split Air Regulation. Control Mode Auto Control channel feedback based on air pressure sensor. Drive Type Air Reg 2 Automatically selects Air Reg 2 as drive type. Input Filter 79 Amount of fi ltering applied to the control channel feedback frequency. Pressure Drop 0 Difference in pressure sensor mounting location to the seed disk in inches of H 2 0. Pressure Slope 447.2269 The change in pressure sensor voltage to a frequency readable by the IntelliAg system and measured in inches of H20. Should only be adjusted by qualifi ed personnel. Pressure Offset 800 Takes a zero point reading that provides a frequency when the fan is off. Press the Zero Pressure button to calculate frequency. Planter Selection 3PYP Select planter selection of 3PYP automatically adjust to the appropriate calibration settings. Sensitivity Adjust 0 Increases or decreases the calibration parameters in the ranges of -10 to +10. Increasing response time makes the system response quicker. STEP 8: Row Monitor At the Main Work screen, press the Row Monitor button. Enter desired values using Table F as reference. Press the Work Screen button to return to the Main Work screen. TABLE F: Row Monitor Material Name Default Value/Value to Enter See Instructions Material Name only appears on the Row Monitor screen when all control channels are disabled and material is set for Monitor Only. This is only used for ground drive/nonhydraulic applications to monitor population with high and low alarms. A material must be confi gured and selected to activate alarms. High Alarm Delay 5 Desired number of seconds that high population can be above high alarm point before alarm will sound. Low Alarm Delay 5 Desired number of seconds that low population can be below low alarm point before alarm will sound. Population Adjust 100 Enter a % to allow for seed sensor population inaccuracies to achieve the desired population display. 100% represents true calculation. Population Filter 50 Set fi lter value to stabilize the monitored population display. Number can be set to 0% for no fi ltering and 99% for high level fi ltering. Row Fail Rate 2/1 (2 seeds every 1 second) Set to desired number of seeds per second to trigger seed sensor failure alarm. 3

STEP 9: Speed Set Calibration At the Main Work screen, press the Speed Set button. Enter desired values using Table G as reference. Press the Work Screen button when ground speed calibration confi gurations are complete to return to the Main Work screen. STEP 10: Accessory Sensor Hopper Assignment At the Main Work screen, press the Next Page button. Press the Confi guration button to display the Confi guration screen. At the Confi guration screen, press the Hopper Assign button. Press Hopper Set button. Enter desired values using Table H as reference. RPM Assignment 6. At the Confi guration screen, press the Accessory Assignment button. 7. Press the RPM button. NOTE: There must be at least 1 RPM sensor confi gured before the RPM button appears on the screen. 8. Enter desired values using Table H as reference. STEP 11: Clutch Folding (CFM) The CFM is installed in the cab to control row clutches, wing fold, marker tilt, and marker fold. At the Main Work screen, press the Clutch CFG button to access the Clutch Confi guration screen and verify that the correct # of clutches are confi gured for the system. The Clutch CFG button only appears as a top level button when a planter output module and clutch folding module are installed. OUTPUT LEFT CENTER RIGHT # of Clutches 3 # OF ROWS 3 6 3 ROW # s 1-3 4-9 10-12 TABLE G: Speed Set TABLE H: Accessory Default Value or Value to Enter Default Value or Value to Enter Source Digital Frequency Select CAN Ground if radar is connected to ISO tractor cab harness. Select Digital Frequency if radar or hall-effect is connected to WSMT actuator harness. Gspd Constant 12192 Input based on pulse count produced by the ground speed sensor over 400 distance. See Operator s manual for calibration instructions. Shutoff Speed 0.5 mph Set desired minimum ground speed allowed before the system shuts off. Minimum Override Master Sw Timeout Gspd Fail Alarm Delay Precharge Ground Speed 0 mph Set to operate when actual ground speed falls below the designated value. Control will operate at this speed until actual ground speed rises above minimum override speed or actual speed drops below shutoff. 10 Set to desired number of seconds system shuts off if the master switch is turned on and there is no ground speed. Toggle master switch to restart the system and turn off alarm. 5 Set to desired number of seconds alarm sounds after the ground speed is zero and seed fl ow continues. (Monitor only) 0 Set to the desired speed the system will use when a precharge time has been enabled for a control channel. Refer to Table C1: Planter Control for Precharge Time. This setting will only display when a Precharge Time has been entered. Implement Lift Enabled Implement lift switch, when enabled, displays an implement lift indicator on the Main Work screen indicating implement lift position as up or down. Control channels can be turned on and off without using the master switch. Hopper # of Hoppers 1 # of hopper sensors connected to each module (4 sensors maximum). # of hopper data items for each listed module and the Hopp # s value will automatically populate if Auto Confi g is used to confi gure installed sensors. Logic Level Active Lo Sets the active state to low signifying that an alarm is generated if the sensor s output is in a low state. Use this setting if the connected sensor outputs a low condition when empty similar to the DICKEY-john hopper sensor. Alarm Delay 5 sec Controls the delay time between the detection of a high/low hopper alarm condition and the generation of the resulting alarm. The value is entered in seconds. Channel Assigns hopper sensor to channel. RPM High Alarm (fan speed) Low Alarm (fan speed) 3000 rpm Sets the RPM value at which a high RPM warning error is generated. 1800 rpm Sets the RPM value at which a low RPM warning error is generated. High Alarm Delay 10 sec Establishes the delay between the detection of a high RPM alarm condition and the resulting alarm display. The value is entered in seconds. Low Alarm Delay 10 sec Establishes the delay between the detection of a low RPM alarm condition and the resulting alarm display. The value is entered in seconds. RPM Constant 3 pulses/rev Number of pulses per sensor revolution. RPM Filter 0 Filters the signal out of the RPM sensor. Disable Control on Low Alarm Disabled Allows for disabling of all control channels if the RPM value of the selected sensor falls below the low alarm level setting. 4

STEP 12: Clutch Folding Operation The planter section controls turn the left, center, and right clutch controls on and off. Hydraulic drive planters have 2 clutches and use left and right only. The master switch must be in the ON position to activate any planter section. When a clutch control is ON, a green light will illuminate. The frame control switches control the wing fold as well as tilt and fold of the markers. The switches operate on a priority order. When the prioirity 1 switch is active, any lower priority switch turned on will NOT operate until the switch that takes higher priority is turned OFF. STEP 13: 5 Revolution Test Press the Control button. Press the Channel button. Press the Next Page button. 6. Ensure implement is raised before starting 5 Rev Test. With brakes locked and transmission in PARK position, start tractor engine. Engage hydraulics and run engine at normal speed until hydraulic fl uid is at operating 7. temperature. Press the 5 Rev button. 8. 9. Test Ground Speed and Row data must be entered to perform test. Press and hold remote test button to initiate 5 Rev Test. Master CFM Switch Planter Section Controls MASTER Left Center Right Wing Fold Marker Tilt Marker Fold CLUTCH Priority Assignments: Priority 1: Wing Fold Priority 2: Marker Tilt Priority 3: Marker Fold Planter Frame Controls STEP 14: Summary Screen The Summary screen provides an overview of setup constants for active control channels. At the Main Work screen, press the Next Page button. Press the Summary button To view specifi c control channel confi gurations, press the respective control channel box 1- Press inside a yellow highlighted box to open a specifi c screen for editing. Press the Work Screen button to return to the Main Work screen. Summary Screen 5

- Quick Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro Battery Tractor + CFM 467984210S1 Rows 1-3 Left Section Row 1 Row 2 Row 3 Connect to 467980132 467980143 25 Tractor Cab 467980455 467980452 (5 Terminal) or 467980451A (10 Terminal) CFM 467980330 CAN Terminator 467980126 Chassis Ground Virtual Terminal WSMB Seed Monitor 467981100S1 WSMB 467981201A Output 1 Marker Tilt Output 2 Marker Fold 464820511S1 Output 1 Left Clutch Output 2 Center Clutch Connect Cab to Implement Can Tractor ECU Controller (467985060S1) Ignition Connect to switched +12VDC. NOTE: This wire must be connected to switched +12VDC RS232 GPS (467980451 ) Master Switch (467980124S1) Note: Connect the WSMT Actuator and the Dj Planter to the mating connectors of the WSMT Rows 4-9 Middle Section Row 4 Row 5 Row 6 Row 7 Row 8 Row 9 WSMT II 467980815S1 Connect to Actuator 467980160 467980143 25 WSMT 467980151 467980143 25 464820513S1 Planter Output 467982000S1 464820512S1 Right Clutch Output 1 467983504 Output 2 Wing Fold Clutch Control Implement CAN Breakaway 467980132 Connect to Optional Hydraulic Tongue or to Application Rate Sensor (Channel 1-4 Feedback) Labeled FB1-FB4 Radar Speed Sensor 467833000S1 (Radar connected to either tractor harness or WSMT as shown below) ACTUATOR HARNESS 467980160 PWM Solenoid Valves 466820832S1 10 457901815 Adapter 467980172 Accessory Sensors connection to WSMT Actuator 467980160 Pressure Sensor 467980496 Rows 10-12 Right Section Row 10 Row 11 Row 12 WSMB Seed Monitor 467981100S1 WSMB 467981201A Can Terminator Hopper Level Sensor 466820720S3 Implement Lift 466820713 Actuator 467096050 Implement Lift Sensor 464820520S1 If no implement lift sensor is used, connect the IMP LIFT leads together Fan/Shaft RPM Sensor 466970014S1 5 457901826 Hopper 466820714 Fan 459680922 Servo Valves (Labeled Servo 1 and Servo 2) Test Switch Radar Speed Sensor 46783300S1 (Radar connected to either tractor harness or WSMT as shown below) System Component Installation Locate and install system components as shown in the diagram. Note how the modules are identifi ed and which modules are located on which sections in this system. Connect WSMB module harnesses together with included extensions. s connect to the WSMT harness connection. Plug all unused connectors with included dust plugs. Secure any excess wires with tie-wraps. See Operator s Manual for additional installation information. Power on monitor and program with correct constants as described on this Quick Start Guide. 6