all combustible gases and fuel oil, extra light gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼

Similar documents
KINEMAX. Medium velocity gas or oil burners

MULTIFIRE. High temperature dual fuel burner

1470 SERIES HOT AIR GAS BURNER

1466 SERIES COLD AIR GAS/OIL BURNER

1070 SERIES ULTRA LOW NO X

Eclipse RatioAir Burners

Specifications of STICKTITE and PILOTPAK Nozzles

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

North American 4485 Tempest SE

Specifications of MAXON VALUPAK burners for 50 Hz operation

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

VALUPAK. Packaged gas burners

FUEL OIL BURNERS. By Mark Butterfield March 09

Data /1/07 Eclipse RatioAir Burners Model RA0040

Doing more for clean environment and energy saving

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK

LVDT/HC PILOT BURNER. External raw gas pilot burner

Specifications of STICKTITE and PILOTPAK Nozzles

2.0 Burner Operating Parameters and Requirements

1200 SERIES FTR HOT AIR BAFFLE BURNER

Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

M10x1 Measuring Spark Plug

Weishaupt WKGL70 dual fuel burner Version 3LN (Low NO x ) multiflam 1/2003 GB

1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER

GTV HVOF K2 Burner OPERATORS MANUAL GTV Verschleißschutz GmbH.

Burners. Self-recuperative burners high speed with flat flame REKO-SIK-SW (E3903 rev /06/2015)

Low emissions, high performance natural gas burners

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

SureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual

Radiant tube burners RT (E3900 rev /01/2018)

Kerosene - oil burner

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

1500 SERIES LARGE CAPACITY ULTRA 2 LOW NO X

M14x1,25 Measuring Spark Plug

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

Burners. Ribbon linear flame burners AB & ABM (E3010 rev /11/2017)

Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual

Oil - kerosene burner

GAS BURNERS BLU 3000 PR BLU 4000 PR

Burners. High velocity LOW NOx combustion air burners EMB-SIK-NxT (E3507 rev /11/2016)

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB

Eclipse RatioAir Burners

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

Heating and Gas Installations - December 2014

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

North American Combustion Burners

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

PREMIX TUNNEL BURNERS

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

TECHNICAL DOCUMENTATION Chapter II COMPONENTS AND FUNCTIONS

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

Burners. Self-recuperative burners high speed free flame REKO-SIK-FF (E3901FF rev /05/2009)

Installation- and maintenance instruction B20KA/K

OIL FIRED FURNACE REPLACEMENT PARTS MANUAL FLF085D36C FLF110D48C. Models: Contents. General Notes. Important

Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

Light oil - kerosene burner

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA

Lecture 27: Principles of Burner Design

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

Burners. Pilot Heads BTC & BTSA (E3121 rev /04/2018)

Combustion Equipment. Combustion equipment for. Solid fuels Liquid fuels Gaseous fuels

North American Combustion Burners

Section 3 Technical Information

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

ONE STAGE GAS BURNERS RDBS SERIES

product Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners

E Series CE Approved Intermittent Pilot Ignition Control

Oxygen Probe Troubleshooting Guide Marathon Monitors, Inc.

Oil, gas and dual fuel burners. Burner series

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

ZEECO BURNER DIVISION

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

INFRA RADIATION EFFICIENCY UP TO 75%

Installation- and maintenance instruction ST120 S75/21

High Tension Spark Igniter (HTSI)

Installation- and maintenance instruction B20KAV/KV

VAL6 KBE5S. Service Manual

Design and Application Details

ENGINE AND EMISSION CONTROL

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

Installation- and maintenance instruction B20K-2

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

Installation- and maintenance instruction B20KA/K

EXHAUST SYSTEM AND INTAKE MANIFOLD

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

Methods of combustion in combustion chambers that are specially adapted for generation of combustion products of high pressure or high velocity.

Installation and Maintenance Manual Please retain this manual for future reference.

Design and Application Details

Transcription:

Technical Specification High Velocity Burner Type HV Content 1 Type Designation Code Key Technical Data 3 Deployment and Mode of Operation 4 Basic Construction of the Burner Installation and Startup.1 Electrical Control. Setting of the Media Throughput.3 Setting of the Electrodes.4 Flame Temperature 6 Maintenance Instructions 1 Type Designation Code Key HV-BG 3-G Fuel (possible are G [gas] and EL [fuel oil, extra light]) Installation Size (available for gas: 1,, 3 and 4; for oil: 3 and 4) High Velocity (high-speed) Technical Data Nominal Heat Output to 600 kw (see type plate) Fuel all combustible gases and fuel oil, extra light Fuel Pressure gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼ Throughput Control externally, via pressure or volume flow control Air Pressure up to 60 mbar at the burner head, depending on version Air Connection depends on installation size, 1 ¼, 1 ½, or x Air Temperature max. 30 C (see type plate) Air Flow depending on installation size, up to 600 Nm³/h Air Flow Control externally, via pressure or volume flow control Hot Gas Outlet Port depends on installation size, graded as of ø 30 up to ø Firing Chamber Material depends on application, available are: SiSiC (up to approx. 130 C combustion chamber temperature) ReSiC (up to approx. C combustion chamber temperature) HEXOLOY (up to approx. 1700 C combustion chamber temperature) Hot Gas Exit Speed up to 0 m/s Ignition ignition electrode (s), ignition transformer x 7, kv (fuel oil) or 1 x 1 kv (gases) Flame Monitoring ionisation electrode, UV cell (gases) or photo cell (fuel oil) Seite 1 von 6

3 Deployment and Mode of Operation Type HV burners are preferably deployed as side and roof burners both in continuously and intermittently operated industrial furnaces. They can however also be deployed as bar burner or in air heaters. As each burner is separately equipped with a ignition unit and a flame monitoring system, the deployment within temperature ranges below the fuel ignition limit is possible without any problems. As Type HV burners can reach high hot gas exit speeds, they are also often used as recirculation burners. To ignite the burner, the set λ-value should not be higher than. During operation, it is possible to reach λ-values of up to in modulating operation mode. 4 Basic Construction of the Burner Burner head with fuel and air connections, electrodes and inspection glass Burner flange plate for the attachment of the burner Burner tube (length is determined by the respective wall thickness) Mixing system with firing chamber and firing chamber seal gasket (the diagram presents a version for gases with ionisation electrode) Page of 6

Installation and Startup The burner and the firing chambers are separately packed and transported. Before conducting the installation of the burner, the firing chamber must be mounted and the gasket ring for the firing chamber sealing must be brought into the correct position. After this, the burner is inserted into the fire hole and, if necessary, fixed using he flange plate. The firing chamber is made of ceramic and very shock-sensitive, respectively prone to breakage! After both the fuel and air supply lines have been connected and the ignition and flame monitoring devices have been installed, the burner can be set into operation. It is necessary to observe that the clearances between the deployed electrodes to each other, respectively against the ground potential are correctly installed according to the specifications. The setting of the fuel and air flow is conducted according to the provided throughput curves..1 Electrical Control If the burner is deployed within temperature ranges below the fuel ignition limit, an automatic ignition device and an ignition transformer must be allocated to the burner. In order to be able to utilise the complete possible operational range of the burner, we recommend to deploy automatic firing devices of the type series LFL, LGK or LOK. In connection with an ignition device Type TQO as well as an optical flame monitoring unit, very good results were achieved in regard to operational safety even under extreme operational conditions. After activation of the automatic ignition device and the expiry of the pre-rinsing period, the ignition transformer starts up and the fuel nozzles open up. The fuel is now ignited, the burner is in operation, and the flame monitoring unit reports the existence of the flame. If the ful is not ignited after expiry of the ignition time, the fuel nozzles are closed and the automatic ignition device will report a malfunction. After the unlocking of the automatic ignition device, the start programme will start again.. Setting of the Media Throughput The setting of the fuel and air flow rate is conducted according to the provided throughput curves. The ideal burner setting depends on the respectively intended use of the burner. For the initial setting of the fuel and air flow rate, flow rate measuring devices for both the fuel and air flow rate should be deployed. Later comparative measurements, respectively readjustments, can also be conducted using a manometer. For this purpose, the same are connected to the measuring nipple for fuel (at the magnetic valve), respectively for air (at the burner head see also Attachment A ).3 Setting of the Ignition and Ionisation Electrodes At Type HV gas burners, the ignition is conducted against ground. The ground is hereby represented by the gas nozzle. It is important to observe that the ignition spark is positioned directly in front of a gas nozzle bore (for this purpose, it may be necessary to slightly turn the nozzle fitting tube together with the gas nozzle in the orifice plate.) At Type HV burners for fuel oil, the ignition is conducted between two electrodes. The position of the arc is hereby located, seen from the direction of the air flow, in front of the orifice plate. Page 3 of 6

Electrode Settings for Fuel Oil: a =.0 mm b = 1. mm c = 1.0 mm X Y Electrode Settings for Gases: x = 1. mm y = 1 mm.4 Flame Temperature / Hot Gas Exit Temperature The flame temperature is determined b the ratio of combustion air to fuel. The flame temperature is the temperature which can be measured at a combustion in the interior of the flame. The flame temperature depends on the degree of mixing of the combustible gases, the oxygen content of the gas mixture, the level of pre-heating of the gases, as well as the construction of the burner. Within a flame, there are usually different areas, the temperatures of which may vary by several hundred Kelvin. The maximum flame temperature varies according to the characteristics of the combustible substance and is approximately situated with the following ranges: liquid fuels: from 1300 to 1600 C, gaseous fuels: from 1600 to 3000 C. 6 Maintenance Instructions Type HV burners contain the following wear parts: electrodes, fuel nozzles, possibly optical flame monitoring devices. Consequently, it is necessary to regularly perform the following maintenance: 1.) Semi-Annual Switch off the burner, turn off fuel supply, remove and clean inner section (e.g. by blowing out with compressed air), visual check for mechanical damage, if necessary, exchange parts.) Annual Maintenance Switch off the burner, turn off fuel supply, remove and clean inner section, the electrodes (and, in case of gas burners, the stabilisation clamps) must be exchanged 3.) Maintenance after/every 18 Months Accords to the half-yearly maintenance plus the exchange of the optical flame monitoring device 4.) Maintenance after/every 4 Months Accords to the yearly maintenance plus the exchange of the fuel nozzle HIGH-TECH Brennsysteme GmbH Page 4 of 6

Attachment A Throughput Diagrams The throughput diagrams presented here are merely exemplary. Individual, special applications, due to the respectively specific construction, may generate different volumes. V / Bm³/h @ 0 C 3 SIC 70 SIC 4 SIC 30 Luftdurchsatz air volume through the burner 1-1 3 4 1 Luftdruck am Brennerkopf gemessen air pressure measured on the burnerhead p / mbar Gasdurchsatz / gas troughput Bm³/h 0 1 9 x 3,0 mm 9 x,9 mm 9 x,8 mm 9 x,7 mm 9 x,6 mm 9 x, mm 9 x,4 mm 9 x,3 mm 9 x, mm 9 x,1 mm 9 x,0 mm Heizwerte Erdgas H:,3 kwh/m³ 37,6 MJ/m³ 8,90 Mcal/m³ 0 0 mbar 00 Überdruck an der Düse / gas overpressure on the nozzle Datenblatt Standarddüsen HV-BG3-G / data sheet standard nozzles HV-BG3-G Page of 6

Page 6 of 6