MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

Similar documents
BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

KDM ARMORED FLOW METER & SWITCH

EZ-View. Flow Meters ISO CERTIFIED 9001

NBK-M - Economical Level Indicator

Vortex Eggs Delta Flowmeter

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

King Instrument Company opened its doors in 1983 with one major goal:

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500

F-2600 SERIES INLINE VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

F-2700 SERIES INSERTION VORTEX FLOW METER

mass flowmeter for compressed air

F-1500 SERIES INSERTION TURBINE FLOW METER

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Variable Area Flowmeters Ori-Flowrator TM Meters

G2 Industrial Grade Meters

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

VAREA-METER FLOW MEASUREMENT BY-PASS TYPES

2100 Turbine Flow Sensor

Flow-Alert Flow Switches (Micro Switch)

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2

MINI-NBK ECONOMICAL LEVEL INDICATOR

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

DPT TARGET TYPE FLOWMETERS

APG. Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX. Features

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

PISTON STYLE GAUGE. Mid-West Instrument

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Signet 2551 Magmeter Flow Sensor

Variable Area Flowmeters Armored Purgemeter

PSF50 Paddle flow switch

Pressure Transmitter

Hot Tap Insertion Vortex

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

8000 Series Liquid Flow Meters

UNIVERSAL Flow Meters

ABB Automation. Variable Area Dial Flow Indicator Series 10A2227. Series 10A2227 Variable Area Dial Flow Indicator

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

Glass Tube Full-View Flowmeters

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

F-2600 SERIES INLINE VORTEX FLOW METER

8000 Series Liquid Flow Meter

Model FVP General Specification. Flanged Vortex Plate. Product Features

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Product Summary. Flow Meters. Hydraulic Diagnostic Products

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Model Q45H/ Residual Chlorine Monitor...

MODEL 106F TEFLON LIQUID FLOW SENSOR

PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves. Pressure Control Techniques. Dynamic Range

VLM20 In-line Vortex Flowmeter

VIM20 Vortex Insertion Flowmeter

RCM. Direct Reading Flowmeter. for Liquids or Gases

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

9012G Pressure and 9016G Vacuum Switches

Dissolved Oxygen Measurement System with Air Blast Cleaner

Pressure Instrumentation

Vortex Plate. Model VP General Specification. Product Features

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

Model DFX Doppler ultrasonic flow meter

KEL DIFFERENTIAL PRESSURE FLOWMETERS

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

LTX RF LEVEL SENSOR. Instruction Manual

Product Catalog Pressure Regulators. Proportional Valves

Multivariable Vortex Flow Meter

Principle of Operation

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

PMG MAGNETIC FLOWMETER

Data Sheet. I/P and E/P converters. RS stock numbers ,

Low Profile Insertion Vortex

Ultra Compact UHP Liquid Flow Controllers

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

SmartBob II SBR.1 A M1 H X X XX. Base. Mounting Plate. Cable. Heater. Probe

Armstrong In-Line and Insertion Vortex Flow Meters

WP Series Hydraulic & Pneumatic Flow Monitors Illustrated Price List

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

PYTHON 1500 SERIES CONTROL VALVES. Pneumatic and Electric Actuated

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

STEEMCO-MAS Flowmeter for Steam

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

Transcription:

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP DESCRIPTION The MEMFlo MFTV Metal Bodied Flow Meters with Clear Top are simple, accurate, meters for use in a wide range of industrial liquid and gas applications. These meters have an excellent tolerance to suspended solids and measure flow to one percent accuracy. Unlike tapered tube rotameters, MFTV flow meters have an indicator disk in close proximity to the edge of the sight tube for visibility even in many dirty fluids. These meters can be supplied with the MFT2 2-Wire Flow Transmitters for flow rate and total. 600 PSIG OPTION FEATURES & BENEFITS Tough, simple, & accurate meters for water, oils, coolants, compressed gases, lubricants, mild slurries & other general industrial applications. Excellent tolerance to suspended solids. Extended flow ranges averaging 30 to 1. Disassembles in less than a minute without removing the meter from the pipeline. Good readability even in dirty fluids. T-316 stainless bodies & internals, with polysulfone measuring tube. No springs, cams, or seals to wear out. Standard 1/2 to 4 female NPT connections or optional flanges. Pipe adapters may be used for other sizes without affecting accuracy. Flows to 500 GPM liquids or 5750 SCFM gases. 360º rotation of scale. Special scales for other units or fluids & multiple scaling offered. Options include MFT2 2-Wire Flow Transmitter, alarms, pressure gauge oxygen cleaning, and panel mounts. Optional 600 PSIG Economically priced. TECHNOLOGY MEMFlo MFTV Metal Bodied flow meters are patented variable area flow meters using the the volumetric principle of flow measurement. These meters consist of five main parts including the body/measuring tube, core tube, float assembly, scale, and pitot tube. The meter is not a glass tapered tube, rather the media enters the meter vertically at the bottom inlet port and flows upward into the core tube. Then the media flows horizontally through the core tube slot and exits the meter through the side outlet port. During this process the media lifts the float assembly in the core tube in direct proportion to the rate of flow. The slotted core tube design gives the meter an excellent tolerance to suspended solids and there are no springs, cams, or dynamic seals to wear out. The polysulfone measuring tube displays flow rate by reading the sight disc on top of the float assembly. The optional MFT2 Flow Transmitter has an analog 4-20mA or 0-5, 0-10 VDC output to a remote display, PLC, Recorder, or other customer-supplied receiver. Using a simple and rugged design, the MEMFlo Metal Bodied Flow Meters with Clear Top measure to 1% accuracy.

SPECIFICATIONS Accuracy Repeatability Rangeability Materials Pressure Rating ± 1% of 100% flow rate 1/2 to 1½ : +/- 1/4% of indicated flow rate 2 to 4 : +/- 1/2% of indicated flow rate 30 to 1 average 1/2 to 2 Small Body: T-316 Stainless Steel 2 to 4 Large Body: Zinc Phosphate, Xylan 1052 coated steel with all stainless internals Up to 300 PSIG *Optional 600 PSIG Temperature Rating O-Rings Scales Up to 300ºF (pressure ratings decrease at higher temperatures). Buna N standard; Viton, Ethylene- Propylene (EPR), Silicone, Neoprene, Kalrez and Teflon optional. Standard direct reading (GPM or LPM Liquid, Sp. Gr. = 1.00 or SCFM Dry Air @ 100 psig, 70ºF.) or percentage scale. Special scales for other flow units or media conditions, or mylar scales for corrosive environments are available at extra cost. Note: Please Consult Factory for Special Requirements DIMENSIONS Small Body BODY & MEAURING TUBE DESCRIPTION A A B C D E F G Female NPT Stainless & Polysulfone 9.36 9.66 2.81 2.68 4.00 1.35 2.72 3.00 Up to 3/4 Stainless & Polysulfone 15.22 15.36 4.53 3.71 5.70 2.48 3.95 5.00 Up to 2 BODY & MEASURING TUBE DESCRIPTION H I J K L 150lb Flange Stainless & Polysulfone 10.24 3.69 3.56 2.75 3.88 Up to 3/4 Stainless & Polusulfone 16.61 5.92 4.96 3.88 5.00 Up to 2 Note: All dimensions are in inches, with a tolerance of ±0.03 on threaded models, ±0.20 on flanged units.

Large Body BODY & MEASURING TUBE DESCRIPTION A B C D E Female NPT Stainless & Polysulfone 20.23 6.38 5.38 3.63 NA 2 Stainless & Polysulfone 20.85 6.38 5.38 3.36 NA 2½ Stainless & Polysulfone (150 GPM/1750 SCFM) 22.35 7.50 6.00 4.25 NA 3 Stainless & Polysulfone (200 GPM/2300 SCFM) 26.85 8.63 7.13 5.56 NA 4 BODY & MEASURING TUBE DESCRIPTION A B C D E 150lb Flange Stainless & Polysulfone 20.73 6.28 6.88 6.00 4.75 2 Stainless & Polysulfone 21.35 6.88 6.88 7.00 5.50 2½ Stainless & Polysulfone (150 GPM/1750 SCFM) 22.60 7.75 7.75 7.50 6.00 3 Stainless & Polysulfone (200 GPM/2300 SCFM) 28.10 9.88 9.88 9.00 7.50 4 Note: All dimensions are in inches, ±0.05. Subject to change without prior notice.

COMPLETE FLOW SYSTEMS AND ACCESSORIES MFT2 TWO-WIRE FLOW TRANSMITTER MOUNT TO YOUR VOLUMETRIC FLOW METER FOR OUTPUT FLOW RATE DESCRIPTION The MFT2 two-wire flow transmitter accurately calculates and outputs flow rate. Compatible with any MEMFlo variable area flow meter, MFT2 combines FLO-CORP s time-proven variable area technology with a high tech processor and solid state circuitry. Each device includes an analog output that can be configured for 0-5 VDC, 0-10 VDC, or 4-20 ma current loop. Typical applications include pump flow output, compressed air consumption, cooling flow monitoring, steam flow usage/optimization and combustion gas metering. FEATURES & BENEFITS Non-contact sensor electronic Electronic signal conditioning circuit 3 output modes: 4-20mA, 0-5 VDC or 0-10 VDC Proportional analog output - two-wire, 4-20mA Designed to slip over any standard measuring tube Pre-calibrated from the factory for fast installation and start-up SPECIFICATIONS General Process Temperature Ambient Temperature Environmental Accuracy Repeatability Electrical Power Requirements Power Consumption Analog Outputs F: -20º to 240º C: -29º to 116º F: -20º to 158º C: -29º to 70º Humidity: 0-90% non-condensing ±1% 0.25% rate ±0.10% rate 0.5 VDC Output 10-30 VDC @ 3 wire 0-10 VDC Output 12-30 VDC @ 3 wire 4-20 ma Output loop-powered, 12 VDC - 30 VDC - 2 wire 25 ma maximum 0-5 VDC and 0-10 VDC into 10,000 Ohms minimum; 4-20 ma into 1000 Ohms maximum Resolution 1:4000 4-20 ma limited by cable resistance Transmission Distance (4000 ) 0-5 VDC 1000 feet (330m) maximum 0-10 VDC 1000 feet (300m) maximum Circuit Protection Reverse polarity and current limiting Isolation Inherently isolated from the piping system Transient Over-Voltages Category 3, in accordance with IEC 64 Temperature Drift 50 ppm/ºc (Max) Enclosure Rating NEMA 4 (IP67) ; NEMA 7 DigaCom 2000 Universal Process Display is a field mount display that provides bright, 6-digit LED indication, internal DC power supply for transmitter power, 4-20mA repeat output and advanced communications. DigaCom features digital push button configuration, simple programming interface and Ethernet communication. This device is well suited for a variety of process applications. Typical applications include level monitoring, analytical measurements, flow, distance monitoring, pressure monitoring, weight/ volume monitoring and temperature monitoring. DigaLink 3.0 Alarm & Monitoring Software is FLO-CORP s unique Alarm, Configuration and Monitoring Software. This enables users to receive e-mail alerts, configure, and remotely monitor from the convenience of their PC. DigaLink is unique in it s communication protocol that utilizes both TCP/IP Ethernet communication and Modbus/RS485 serial communication simultaneously. This advanced software features e-mail alerts, display configuration, datalogging and real-time monitoring from unlimited devices. With DigaLink you can easily setup, monitor and receive e-mail alerts from practically anywhere. exmod Relay Expansion Module is a 4-relay output module that connects to the display via RS-485 serial communication (4-wire). It is extremely versatile and can be mounted locally or remotely to allow for a purely distributed system. Display(s) can be mounted in the plant or control panel, while the exmod can be mounted in the motor control cabinet for reduced cost of control wiring. Additionally, the exmod s BIG 10 AMP AC/DC rated relays bring added value to your control/alarm monitoring systems.

Ordering Information FLO-CORP MODEL NUMBER BUILDER For Assistance Call 877.356.5463 Use the diagram below, working from left to right to construct your FLO-CORP Model Number. Simply match the category number to the corresponding box number. Example: MFTV-GSU-0508-TCB MEMFlo MFTV Flow Meter for Gas Service, SST Body, Polysulfone sight tube, 1-20 SCFM, 1 Connection Size, Female NPT Threaded Connection, Corrosive Resistant Scale, Buna-N O-Ring, No Additional Options MFTV MFTV Service (1) L) Liquid G) Gas Body Material (2) S) T-316 Stainless Steel (1/2 to 1½ small body) Zinc Phosphate, Xylan 1052 Coated Steel (2 to 4 Large Body) Sight Tube Material U) Polysulfone G) Armored Glass Capacity Designator (3) H GPM Liquid SCFM Gas 00) 0.025-0.545 0.16-3.2 01) 0.04-0.8 0.5-5 02) 0.6-1.2 0.3-7.4 03) 0.08-1.64 0.5-10.2 04) 0.1-2.6 0.6-14 05) 0.15-3.8 1-20 06) 0.5-5.4 1-26 07) 0.2-7 1-35 08) 0.2-10 2-50 09) 0.6-15 3-70 10) 0.5-20 4-85 11) 0.5-11 6-125 12) 0.7-15 6-160 13) 1-21 4-260 14) 0.5-35 1.5-25 15) 1-50 1-31 16) 2-70 2-40 17) 3-90 3-70 18) 4-120 4-100 19) N/A 5-140 20) N/A 5-175 21) N/A 6-250 22) N/A 2-310 23) N/A 7.5-390 24) N/A 10-510 25) N/A 35-750 26) N/A 20-1,000 27) 3-70 30-750 28) 3-100 40-1000 29) 6-150 50-1750 30) 3-100 40-1000 31) 6-150 50-1750 32) 10-200 100-2300 33) 14-300 150-3500 34) 5-100 50-1200 35) 10-200 100-2300 36) 14-300 150-3500 37) 15-400 200-4600 38) 20-500 230-5750 Connection Size (4) 04) 1/2 06) 3/4 08) 1 12) 1½ 16) 2 16) 2 20) 2½ 24) 3 32) 4 Connection Type (5) T) Female NPT Threaded F) ANSI 150lb Flange X) Special Connection Scaling Options (6) C) Vinyl P) Percent of Flow M) Multiple Scales X) Other O-Ring Material B) Buna-N E) EPR (Ethylene Propylene) K) Kalrez N) Neoprene S) Silicone T) Teflon V) Viton Additional Options (7) N--) None GP#) Gauge Port GS#) T-316 Pressure Gauge AG1) Armored Glass Sight Tube (connection size: 1/2-1 ) AG2) Armored Glass Sight Tube (connection size: 1½ - 4 ) HPO) 600 PSIG Option Ordering Notes: (1) Select the best configuration based on your requirements. (2) Stainless bodies available in large body sizes. Please consult factory. (3) Sizing is based on GPM Liquid, Sp. Gr. = 1.00 or SCFM Air @ 100 psig 70 F (4) Connection Size is based on Capacity - Colors must match to ensure compatibility. (5) If you require a Special Connection (X), please consult factory with requirements. (6) For digital or custom scaling, select Other (X) and note the following requirements: Digital Display: Requires Flow Monitor (Consult Factory for best option) Custom Scale: Requires Flow Application (Consult Factory) (7) To package the MFT2 flow transmitter see MFT2 data sheet model number builder Note: Match color with connection size.