Measuring Pump Efficiency with Mike Eglitis

Similar documents
Public Review Draft Proposed Addendum cv to Standard , Energy Standard for Buildings Except Low-Rise Residential Buildings

Understanding NEMA Motor Nameplates

High Capacity Centrifugal & Sprinkler Pumps

HIGH CAPACITY CENTRIFUGAL & SPRINKLER PUMPS

Guidance Document EP.NA.

EPACT ENERGY POLICY ACT OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER

Motor Efficiency Improvements for Pumping Applications. Brent McManis, P.E. Industry Engineering Manager Baldor Electric: A Member of the ABB Group

Motor Basics AGSM 325 Motors vs Engines

Efficient Variable Speed Pumping: A Low Cost Approach to Green Energy

FAN ENGINEERING. Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia ( ) 2

CYCLO HBB. ofc. Gearmotor. Premium Efficient Motor Edition. Catalog

AAFAME Presentation. Shermco Industries Inc. Drives and Automation Application, Sales and Service Manager, Irving Texas.

The Energy Policy Act. The law s requirements for 1 to 200 horsepower AC motors effective October 24, 1997

الهيئة السعىدية للمىاصفبت والمقبييس والجىدة Saudi Standards, Metrology and Quality Org (SASO)

Steve Schouten. Donna Densmore

General Catalog. A New Vision for Quality Pumps. General Catalog

Product Numbering System Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC Pump Assembly, Types AC & AE

Variable Frequency Drives

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM

Commercial Pressure Booster Systems

DWO DWO DWO DWO

Low Voltage Fuses For Motor Protection

SERVICE THE GORMAN-RUPP COMPANY P.O. Box 1217 MANSFIELD, OH FX

Energy Independence & Securities Act Frequently Asked Questions

Save Thousands of Dollars Per Year!

PAC TRAINING PUMP MOTORS

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

SECTION MOTOR REQUIREMENTS for HVAC

You have probably noticed that there are several camps

Full Voltage Starting (Number of Starts):

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

Inline Pumps. Product review. Wilo-VeroLine-IPL. Single-head pumps: Single stage inline, flanged, long coupled, mechanical sealed dry rotor pump

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

IMPROVING MOTOR SYSTEM EFFICIENCY WITH HIGH EFFICIENCY BELT DRIVE SYSTEMS

HYDROMATIC HE8/HE12/HE20/HE25/ HE30/HE35/HE50 HIGH HEAD FILTERED EFFLUENT

Contents. Identification

Permanent Magnet Motors for ESP Applications Updating the Track Record of Performance. Lorne Simmons VP Sales & Marketing

PIP ELEMT01 Guidelines for Selecting IEEE and API Standards for AC Motors 250 HP (185 kw) and Larger

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps

SKHS SERIES 2 HP 1-1/2 HP 1 HP 1/2 HP CAPACITY-U.S. G.P.M.

DOCUMENTATION PACKAGE

HYDROMATIC SPX50/SPX50H EXPLOSION PROOF, SEWAGE EJECTOR

Goulds 7200CB. API th Edition / ISO nd Edition API BB5 Barrel Multistage, Radially Split In-Line Diffuser Type

It s What s Inside that Counts

Over 525 Stock Motor Ratings. The Right Pump Motor for your Application. Leadership in Premium Efficiency. 1

2CDU70/206-2HP 2CDU70/306-3HP CDU120/306-3HP 2CDU200/506-5HP 607

AMERICAN STAINLESS PUMPS STAINLESS STEEL PUMPS FOR THE COMMERCIAL MARKETPLACE

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

ECET 211 Electric Machines & Controls Lecture 5-4 Electric Motors. Lecture 5-4 Electric Motors

CUSTOM DC MOTORS & GEARMOTORS

Off-line filter / cooler unit BKF

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS

SPD50H/100H. Performance Data SPD100H SPD50H. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

How to implement higher efficiency motors

High-pressure In-line Pump. Movitec. 50 Hz. Type Series

ECET 211 Electric Machines & Controls Lecture 2-3 (Part 3 of 3) Symbols and Drawing for Electric Motor Control Systems

Item No. Specifications Selection Performance Pump Sectional View Chart Curve Dimensions

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

Matched Performance TM Medium voltage drives and motors for energy efficiency and process control

HYDROMATIC SKHS SERIES SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

Auditing Water System Pumps for Efficient Operation. Tyler Clary, P.E. City of Vancouver

Motors & Drives Rebate Application

Industrial and Commercial Duty IEC Motors

Vertical Pumps for the Oil & Gas Industry

DOCUMENTATION PACKAGE

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

Volume 2 Charts, Formulas, and Other Useful Information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

BERKELEY CENTRIFUGAL PUMPS AND ACCESSORIES CANADA 2013 LIST PRICES

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

AUCOM WHITE PAPER SERIES GET YOUR MOTOR RUNNING. An introduction to reduced voltage starting of three phase induction motors

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

scfm (6.5 psi) Max HP

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

Pneumatic Conveying Systems. Division of

Table 1. Lubrication Guide

DATA SHEET. Three Phase Induction Motor - Squirrel Cage. Customer : Product code : : W22 NEMA Premium Efficiency Three-Phase

Off-Line Filter BNF. FluidControl

Multi-Institutional Academic Health Science & Research Center Evansville, IN

RADIAL ALUMINUM LOW PRESSURE

franklinwater.eu 50 HZ EH - EHsp SERIES HORIZONTAL MULTISTAGE AND SELF-PRIMING PUMPS

SM / SMI N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

Benefits of VFD for single to three phase conversion

DARTMOUTH COLLEGE DESIGN February 15, 2006 & CONSTRUCTION GUIDELINES

VERTICAL MULTI-STAGE PUMPS

VERTICAL MULTI-STAGE PUMPS

5GB, 7GB, 10GB, 18GB, 25GB, 33GB

Square HeadTM Concrete Vibrators. wycotool.com

SUPER-MAX INDUCTION MOTOR

RADIAL ALUMINUM LOW PRESSURE

VCMVerticalInlineProcessPump

HYDROMATIC SK75/100 SUBMERSIBLE SEWAGE EJECTOR

PUSHING MOTOR EFFICIENCY TO THE LIMIT

HYDROMATIC SPD50H/100H SUBMERSIBLE HIGH HEAD, DOUBLE SEAL EFFLUENT

Inverter Speed Ratio Information

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

Transcription:

Measuring Pump Efficiency with Mike Eglitis Centrifugal Product Specialist since 1995 Mitchell Lewis & Staver Co.

Who is MLS? Mitchell Lewis & Staver is the West s premiere value-added integrator of high quality pumps and motors, booster stations and custom applications. We are OEMs for UL listed electrical controls, including soft start systems and Variable Frequency Drives (VFDs) used in moving water and a variety of industrial materials. Established in 1882, we service the Western United States, with locations throughout California, Oregon, Washington, Idaho, Utah and Arizona.

Pump & Motor Efficiency What is efficiency? Often measureable Minimizing waste Maximizing performance Maximizing value: money / time Factors in efficiency Fluid Dynamics: forces acting on the movement of fluid

Pump Mechanics How does a pump move water? Centrifugal pumps Impeller shape Factors in pump selection

Motor Efficiency What makes up motor Efficiency? Conversion of Electricity to mechanical energy Energy losses- Wire resistance, brgs. fans, connectors, which cause Heat.

Motor Efficiency

Measuring Motor & Pump Efficiency Wire to Water Efficiency formula: GPM x Total Head 5300 x KW input

DOE Mandated Motor Performance Standards June 1, 2016 DOE issues new performance standards for electric motors.

U.S. Department of Energy Integral Horsepower Motor Rule Effective June 1, 2016 The U.S. DOE passed a final rule that covers 1 500 HP (0.75 370 kw) three phase electric motors. This new law will supersede the existing Energy Independence and Security Act of 2007. The motors regulated under expanded scope meet the following nine characteristics: 1. Is a single speed motor, 2. Is rated for continuous duty (MG 1) operation or for duty type S1 (IEC), 3. Contains a squirrel-cage (MG 1) or cage (IEC) rotor, 4. Operated on polyphase alternating current (AC) 60-hertz sinusoidal line power, 5. Has 2-, 4-, 6-, or 8-pole configuration, 6. Is rated 600 volts or less, 7. Have a three or four digit NEMA frame size (or IEC metric equivalent), including those designs between two consecutive NEMA frame sizes (or IEC metric equivalent) or an enclosed 56 NEMA Frame size (or IEC metric equivalent). 8. Has no more than 500 horsepower, but greater than or equal to 1 horsepower (or kilowatt equivalent), 9.and meets all the performance requirements of a NEMA design A, B or C electric motor or an IEC design N or H electric motor. Several categories of motors were previously covered at lower efficiency levels or exempt. These motors now must be produced to premium efficiency levels (NEMA MG 1-2011, Table 12-12, 20A or 20B).

Pump Curves B4JPBH 1800rpm Curve

Pump Curves B4EPBM 3600rpm Curve

Pump to Application Efficiency Pressure reading at discharge Flow meter Use of amp meter Create a performance curve Consult WaterTec Findings: Outside best operations point on the curve?

Findings: Best operation points on the curve? On either side of this issue you could be adding cost. To the left: smaller pump? To the right: larger pump?

Is a VFD a solution? Pros: Reducing power consumption Pipe fill mode Adjustable speeds Remote control and monitoring Cons: Upfront investment Doesn t address all scenarios Timely technical service

VFD Multi-speed Curve

VFD Multi-speed Curve

Factors in Pump Efficiency Loss (in the field) 1. Heavy Use / Age of the Pump / Abrasives in the water Impeller wear Reduced efficiency (worn down) Performance shifts to right of BEP Vibration Suction line issues 2. Motor Issues Above rated amperage operation Vibration, bearings, mechanical wear Heat Vibration 3. Irrigation System Worn sprinkler nozzles Leaks System changes Water source conditions Incorrect pipe sizing

New motors vs. Old motors A. Old Motors Size Construction/weight Large cooling openings Air gap B. New Motors More compact Steel or aluminum frames 2017 DOE standard compliance Resilient Improved wiring C. Point of Motor Replacement Operating at high amperage Vibration Rewind or purchase a new motor

Pump: Rebuild or Replace A. Rebuild or Replace a Pump Berkeley: replaceable parts Pump End Kit Cornell: expensive parts Order what is needed B. Age of Pump Is the pump a current model with available parts? If not, a new pump is recommended

Conclusions Start with a good plan. Up front, consider future needs. Design the most efficient system. Engage the tools of technology to focus on the causes and in determining a solution.