Zone manifold DN 25, DN 32, DN 50. Mounting and operating instructions

Similar documents
Zone manifold DN 25, DN 32, DN 50. Mounting and Operating Instructionsi

Pump group DN 32 SA, SMT. Mounting and operating instruction

Pump group DN 25 SA, SMTC, SMT. Mounting and operating instruction

SINUS VERTEILER PRODUCT GUIDE

VICTRIX PRO Wall-hung modular condensing boiler for heating only

Installation and Operation Instructions HeatBloC K31 - DN 25

K35 HeatBloC with 3-temperature mixing valve

Installation and Operation Instructions K38 HeatBloC - DN 32

Pump Stations for Heating Circuits

Installation and Operation Instructions K31 HeatBloC - DN 50

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

Spare Parts List GS 28

Preassembled manifolds with flow meter, series CPRFL

SOLAR THERMAL EQUIPMENT

Installation and Commissioning Instructions High Temperature Zone Module F31-1" (DN 25)

Wash and rinse systems. Page 2. Various and air traps. Page 5. Drain and filter systems. Page 6. Door and hood components. Page 9

KS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors


VAILLANT SPARE PART CATALOGUE

KLINGER. Instructions for installation and operation of. Reflex level gauges K D asbestos-free. wt 3017/11 Page 1.

PRODUCTS FOR HEATING AND TAP WATER SYSTEMS. Product Catalogue

Product Instructions. Mixing Station. Features. Specifications. Materials

Spare parts list UC-S

SILANOS. Spare parts suitable for: Member of the. Fax: +49 (0) Robert-Koch-Straße 3a Planegg/Munich.

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

in cast iron Your Life, our Quality. Worldwide. 65 Wastewater Submersible sewage pumps ( single-channel) in cast iron

Transmission, disassembling and assembling

Ebara Submersible Sewage Pumps (Single Channel Impeller)

DMLV - DMLVF. SUBMERSIBLE SEWAGE PUMPS (VORTEX) in cast iron. Your Life, our Quality. Worldwide. 80 Wastewater

Rear strut assembly - Removal and installation. A. Model 129

SUBMERSIBLE SEWAGE PUMPS (VORTEX) in cast iron

SUBMERSIBLE ELECTRIC PUMPS FOR FOUL WASTE WATER (SINGLE CHANNEL) in cast iron

AKG-A/AKGS-A. Type Series Booklet

SUBMERSIBLE ELECTRIC PUMPS FOR FOUL WASTE WATER (VORTEX) in cast iron

VIESMANN VITOTRANS 100 Plate heat exchanger

Globo P. Ball valves Pump ball valve made of gunmetal

ENG-16, Turbocharger Replacement (Including Tips on K27 Turbocharger Installation)

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

AKG-A/AKGS-A. Type Series Booklet

Pneumatic Screw-in Temperature Controllers

PRESSURE RELIEF VALVE CONTROL VALVE

R o L. BALL VALVE of stainless steel with welded / threaded / flanges ends 440, 442, 443, 445 series SILVER LINE. Description. Edition

Inspection boxes and accessories

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

CLASSEQ LTD. Spares manual D400

CLASSEQ LTD. Spares manual G400

CLASSEQ LTD. Spares manual D500

HYDRAULIC CONTROL VALVES

CLASSEQ LTD. Spares manual G400 DUO

NORI 320 ZXSV Type Series Booklet

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

HYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h) " "1/ "1/ " 8.

CLASSEQ LTD. Spares manual D400 DUO

Thermowell For sanitary applications Model TW61, for orbital welding

Installation instruction

MANIFOLDS AND DISTRIBUTION EQUIPMENT

MASTER DIRECT OIL HEATERS. MODEL 35 CED 10 kw Model ILLUSTRATED PARTS BREAKDOWN. Motor and Pump Assembly

DML - DMLF. SUBMERSIBLE SEWAGE PUMPS (SINGLE-CHANNEL) in cast iron. Your Life, our Quality. Worldwide. 67 Wastewater APPLICATIONS TECHNICAL DETAILS

Spare Parts List GS 14 / GS 15 GS 14 E / GS 15 E

Valves, controls + systems Stations for the connection heat generator/heating circuit

WASTEWATER SUBMERSIBLE MOTOR PUMP MODEL DML3

INSTRUCTIONS AND PARTS LIST FOR MODEL FORCE 10DA and FORCE 25DA (Double Acting, Electrically-Operated Hydraulic Press)

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Screw Pump Twin Aggregates Series SPZ/M MagDrive

Kunkle Bailey 756 safety relief valve

TDU.3 floor distribution unit SK

HERZ PUMPFIX HERZ PUMPFIX. Datasheet 1 45XX XX, Issue Table of contents. Page 1. General information about HERZ PUMPFIX pump groups...

MANIFOLDS & WATER TEMPERATURE CONTROL

SIHI multi. Modular multistage pumps. Type MSL, MSM. Description. Construction. Applications. Technical Data. Options

DML - DMLV. SUBMERSIBLE ELECTRIC PUMPS FOR SEWAGE in cast iron 3,7 5,5 7, LM 80 OUTPUT DIAMETER 80

CLASSEQ LTD. Spares manual G500 DUO

KRAL Screw Pumps. L Series. Catalog. L Series Edition 05/2011 Subject to change.

AKG-A/AKGS-A Type Series Booklet

Ford Racing Front Lower Control Arms (05-12 GT & GT500):

LAUDA Integral. Process thermostats for professional external thermostating across a wide temperature range from -90 up to 320 C

Section L Wet Pipe Systems

Simplex Pump and Socket Ball Valves Pump and Socket Ball Valves

Air-to-water heat pump for indoor installation - LIK 8TES. Spare parts list

2500 Automatic Tank Gauge

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

High. Efficiency. Facts. LESER worldwide. Pilot Operated Safety Valves. Series 810 Pop Action US Units. The-Safety-Valve.com. The-Safety-Valve.

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

40 geothermal ground loop manifolds

Profluid and Gap-type tube filters. Automatic filters

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C

CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC. ML /240 V. 8.5kW ML V. 8.5kW 3-PAN PRO

Ballorex Venturi 3.1 Introduction

AN ISO 9001:2008 CERTIFIED COMPANY. Safety Valve

Spare parts list GS 640 / GS 650

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

LESER LLC LESER S.A.R.L.

Mild Steel Dosing Pots

A E R Z E N S C R E W C O M P R E S S O R S

STAAL 100 Swing check valves PN DN Applications Standard Variants Operating Data Materials Additional Information Purchase Order Data

Side channel pump PN 40 SRZ. self-priming, according to DIN EN 734. Technical description

MV2-DT MV3-D2 MV3-RDP3 MV5-DT

Spare Parts List - DUO 500 & DUO 2

MODEL CMA-180UC PARTS MANUAL Rev 1.19A

INSTRUCTIONS AND PARTS LIST FOR MODEL 25H HAND-OPERATED HYDRAULIC PRESS

Transcription:

Zone manifold DN 25, DN 32, DN 50 Mounting and operating instructions WOMIX Sportowa 31 89-200 Szubin, Poland phone/fax +48 52 382 44 50, +48 52 382 44 51 www.womix.com.pl e-mail: export@womix.com.pl

Central heating zone manifold C60 - DN 25 Two-chamber steel manifold C 60 DN 25-2, 3 or 4 heating circuits was created to simplify installation of pump groups. The factory manifold is equipped with EPP insulation. In addition, the manifold has an output DN 20 on the return side for connecting pressure vessel and the output DN 25 on the power supply for connecting the safety group. On request, the manifold can be equipped with a set of mounting brackets on the wall DELTA (see bushings M8). Max. power: Insulation material: Zone manifold C 60 2F - DN 25 steel ST 37.1 8 bar 45 kw (DT 200C) Nut 1 ½ 1 M directional arrows. Installation should be be carried out according with the directions of the arrows. Supply from boiler Zone manifold C 60 3F - DN 25 Zone manifold C 60 4F - DN 25 2

Central heating zone manifold C70 - DN 25 Two-chamber steel manifold C 70 DN 25-2, 3, 4 or 5 heating circuits was created to simplify installation of pump groups. The factory manifold is equipped with EPP insulation. In addition, the manifold has an output DN 20 on the return side for connecting pressure vessel and the output DN 20 on the power supply for connecting the safety group. On request, the manifold can be equipped with a set of mounting brackets on the wall DELTA (see bushings M8). Max. power: Insulation material.: steel ST 37.1 8 bar 73 kw ( DT 200C) Nut 1 ½ F 1½ M directional arrows. Installation should be be carried out according with the directions of the arrows. Zone manifold C 70 2F - DN 25 Supply from boiler 3

Zone manifold C 70 3F - DN 25 Zone manifold C 70 4F - DN 25 Zone manifold C 70 5F - DN 25 4

Central heating zone manifold C 100 - DN 25 Two-chamber steel manifold C 100 DN 25-2, 3, 4, 5 or 6 heating circuits was created to simplify installation of pump groups. The factory manifold is equipped with EPP insulation. In addition, the manifold has an output DN 20 on the return side for connecting pressure vessel and the output DN 25 on the power supply for connecting the safety group. On request, the manifold can be equipped with a set of mounting brackets on the wall DELTA (see bushings M8). Warning! The exception is the manifold C 100 6F. The above-mentioned manifold can be equipped with a set of mounting brackets on the floor (see the socket G1 "). Max. power: Insulation material: Zone manifold C 100 3F - DN 25 Nut 1 ½ F 1 1/4 M directional arrows. Installation should be be carried out according with the directions of the arrows. Zone manifold C 100 2F - DN 25 Steel ST 37.1 8 bar 110 kw (DT 200C) Supply from boiler 5

Zone manifold C 100 4F - DN 25 Zone manifold C 100 5F - DN 25 Zone manifold C 100 6F - DN 25 6

Central heating zone manifold C 100 - DN 32 Two-chamber steel manifold C 100 DN 32-2, 3, 4, 5 or 6 heating circuits was created to simplify installation of pump groups DN 32. The factory manifold is equipped with EPP insulation In addition, the manifold has an output DN 20 on the boiler side for connecting pressure vessel and the output DN 25 on the installation side for connecting the safety group. On request, the manifold can be equipped with a set of mounting brackets on the wall DELTA (see bushings M8). Warning! The exception is the manifold C 100 6F. The above-mentioned manifold can be equipped with a set of mounting brackets on the floor (see the socket G1 "). WARNING! In order to connect the DN 32 group to the manifold it is necessary to buy additional connections DN 1 1/4 "x 2" or connections with integrated ball valve. Max. power: Insulation material: steel ST 37.1 8 bar 120 kw (DT 200C) 1 1/4" M 1 1/4" M directional arrows. Installation should be be carried out according with the directions of the arrows. Zone manifold C 100 2F - DN 32 The dimension of 140 mm is available until stocks are exhausted Supply from boiler 7

Zone manifold C 100 3F - DN 32 Zone manifold C 100 4F - DN 32 Zone manifold C 100 5F - DN 32 Zone manifold C 100 6F - DN 32 8

Central heating zone manifold C2 100 - DN 32 Two-chamber steel manifold C2 100 DN 32-2, 3, 4, 5 or 6 heating circuits was created to simplify installation of pump groups. The factory manifold is equipped with EPP insulation. Additional manifold is equipped with two thermometers and two the socket ½ " F drain. WARNING! In order to connect the DN 32 group to the manifold it is necessary to buy additional connections DN 1 1/4 "x 2" or connections with integrated ball valve. steel ST 37.1 Max power: Insulation material: 6 bar 220 kw (DT 200C) 1 1/4" M 2" directional arrows. Installation should be be carried out according with the directions of the arrows. Zone manifold C 2 100 2F - DN 32 Supply from boiler Return 9

Zone manifold C 2 100 3F - DN 32 Zone manifold C 2 100 4F - DN 32 Zone manifold C 2 100 5F - DN 32 Zone manifold C 2 100 6F - DN 32 10

Central heating zone manifold C2 120 - DN 50 Two-chamber steel manifold C2 120 DN 50 2 or 3 heating circuits was created to simplify installation of pump groups DN 25, DN 32, DN 40, DN 50. The factory manifold is equipped with EPP insulation. Additional manifold is equipped with two thermometers and two the socket ½ " F drain. Max. power: Insulation material: steel ST 37.1 6 bar 350 kw (DT 200C) 250 mm 2" M 2 1/2" directional arrows. Installation should be be carried out according with the directions of the arrows. Zone manifold C 2 120 2F - DN 50 Supply from boiler Return Zone manifold C 2 120 3F - DN 50 11