GIB TECHNICAL DATA MECHANICAL DIMENSIONS SINGLE/DUAL AXIS ENTRY LEVEL TILT SENSOR (XY/Z) ENTRY LEVEL tilt sensor with MEMS technology.

Similar documents
Voltage Output MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

MELT PRESSURE TRANSMITTERS K7 SERIES PERFORMANCE LEVEL c

MELT PRESSURE TRANSMITTERS K7 SERIES PERFORMANCE LEVEL c

STT280 SEALED TILT SENSOR

ACTUATORS POSITION SENSOR

Seal material. Pressure range. Pressure connection -40 F +212 F 1 -4 F +257 F 3

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

JUMO MIDAS Pressure transmitter

STT280 SEALED TILT SENSOR

Electric Mini Slides MSC-EL

Pressure Transmitters

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Adjustment range. Seal material. Pressure connection

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH Analog /Digital. Technical Data / Description

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH 200. Technical Data / Description. Compact sensor for mobile hydraulics

Electronic Pressure Switch EDS 3000

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

EPI Applications. Features

GTS-L4 5 / 10 / 15 TECHNICAL DATA

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

Hydraulic Valves «DSV»

Electronic pressure switch with integrated analogue output

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA

MOBILE HYDRAULIC SOLUTIONS

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

EPN/EPNCR Applications. Features

MBS 1200 and MBS 1250

Temposonics. Magnetostrictive Linear Position Sensors. MHRM Analog Data Sheet. For embedded or externally threaded installation

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

Differential Pressure Sensors

JUMO MIDAS S05 Pressure transmitter Type

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series MH5 Analog Data Sheet

Angle sensor AN2 series 30

Temposonics. MH-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

ECT Applications. Features

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

Solid State Relays, 3-phase

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

Electronic Pressure Switches

ACCESSORIES FOR GEFLEX SYSTEM

Electronic pressure switch with two switching outputs

Pressure transmitters for heavy duty applications MBS 3200 and 3250

AF40... AF96 3-pole contactors Technical data

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MB Analog. Technical Data / Description

GTS 15/25/40/50/60/75/90/120A

Differential Pressure Sensors

Pressure transmitters for heavy duty applications Type MBS 3250

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

More Precision. Draw-wire displacement sensors

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

MINI MCR-SL-UI-UI(-SP)(-NC)

Temposonics. M-Series PWM. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm. Document Number Revision B

Electronic Temperature Sensor ETS 300

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

HUMIDITY / TEMPERATURE TRANSMITTER

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

0 to 100 up to 0 to PSI (gage) Packard Electric Metri-Pack 150 Series, M12-4 Pole* 1/4-18 NPT ma, VDC, 0-5 VDC, 0-10 VDC

BODAS Pressure sensor PR3 series 10

Data Sheet P1A Pressure Sensor

Proportional directional valve, direct operated, with pq functionality

OBSOLETE. Data Sheet P1E Oxygen Service Pressure Sensor. Main Features. Typical Applications. Attributes. Description

15 Flow Meter SCQ. Measurement principle: spring/piston system

PX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Data Sheet for Linear Sensors

Industrial Contactors CTX 3 3P 185A - 800A

MINI MCR-SL-UI-UI(-SP)

CTE7000 / CTU7000 Series Miniature pressure transmitters

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Industrial Pressure Transmitter

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

LFT RADAR MICROONDE GUIDATE CONTROLLI DI LIVELLO. LFT level sensor the all-round talent with TDR technology. Dimensional drawing.

Temposonics. M-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring length mm. Compact Sensor for Mobile Hydraulics

DIN EN UL 508 / CSA 3RF A A 0 2

Microswitches M series

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Electronic Pressure Switches

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Micro-Machined Silicon Transducers

Intelligent Positioner

RI360P0-QR24M0- INCRX2-H1181 Contactless Encoder Incremental

Temposonics. M-Series Analog. Magnetostrictive Position Sensors. Temposonics MH Measuring length mm SENSORS

PROPORTIONAL VALVES. G1/4, G3/8 and G1/2 tapped body or subbase mounted body with digital pressure control

Type A-10 General Purpose Pressure Transmitters

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

958A Compact. Series 958 Compact Housing LDT. Housing ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS

Transcription:

GIB SINGLE/DUAL AXIS ENTRY LEVEL TILT SENSOR (XY/Z) TECHNICAL DATA ENTRY LEVEL tilt sensor with MEMS technology. Space-saving solution, high performances, easy installation. High IP protection level, resistance to shock and vibration,and high electromagnetic compatibility make this product suitable for many mobile hydraulics applications. Developed to ensure a robust and high-performance solution for applications such as agricultural machines, construction machines, material handling equipments. Measurement range ±0 ±5 ±20 ±30 ±45 ±60 ±85 (single axis Z for analogue output-dual axis XY) 360 (±80 ) single axis Z only Supply voltage +5Vdc (only for 0.5..4.5Vdc output); +0 +36Vdc (see output signal for right supply voltage) Output signal 0.5...4.5V RATIOMETRIC (supply +5Vdc); 0.5...4.5V; 0...0V; 4...20mA; CANopen Electrical connections AMP Superseal 6P 28208-; cable output - PUR sheath conductors 22 AWG Ø 4.4 (single) - Ø 5.5 (redundant); cable output + M2 5 pin male overprinted connector Resolution 0.05 (±0 to ±20 ); 0.05 (±30 ); 0. (±45 ); 0. (±60 ); 0. (±85 ); 0. (±80 ) analog output; 0.05 CANopen output Linearity < ± 0,5% FS (±0 to ±60 ; ±80 ); < ± 0.5% FS (±85 ) Working and coefficient temperature -40 C... +85 C thermal drift < 0.0 / C in the range (T=-0 C..+60 C) Vibrations 20g tra 0 Hz 2000 Hz IEC 60068-2-6 Shock Impulsive on 3 axes; 50g ms IEC 60068-2-27 Electromagnetic compatibility 204/30/EU Electromagnetic Compatibility (EMC) IP protection level IP67 - IPX9K with female mating connector mounted AMP282090- (GIB-A version); IP68 (GIB-F cable-pur sheath version); IP67 (GIB-F cable+m2 connector version) Housing material PBT MECHANICAL DIMENSIONS AMP VERSION CABLE VERSION 22 AWG wires PUR sheath ø 5.5 33 0 3x - 0 3x - 0 Metal insert Maximum torque: 2.5Nm Metal insert Maximum torque: 2.5Nm 32 4 32

ELECTRICAL CONNECTIONS AMP VERSION AMP Superseal 6 pole 28208- connector Mated with connector AMP 282090- CONNECTIONS CAN CONNECTIONS. GROUND. GROUND 2. + SUPPLY 2. + SUPPLY 3. OUTPUT X (dual axis)/ Z (single axis) 4. OUTPUT Y (dual axise)/ n.c. (single axis) 3. n.c. 4. n.c. 5. n.c. 5. CAN L 6. n.c. 6. CAN H SINGLE AXIS DUAL AXIS CABLE VERSION CONNECTIONS CAN CONNECTIONS. BLACK GROUND. BLACK GROUND 2. RED + SUPPLY 2. RED + SUPPLY 3. YELLOW OUTPUT X (dual axis)/ Z (single axis) 4. GREEN OUTPUT Y (dual axise)/ n.c. (single axis) 3. YELLOW n.c. 4. GREEN n.c. 5. BLUE n.c. 5. BLUE CAN L 6. WHITE n.c. 6. WHITE CAN H SINGLE AXIS DUAL AXIS ITEMS MARKED n.c. SHOULD NOT BE CONNECTED

CABLE+M2 VERSION PIN connections cable+m2 PIN RED PIN 2 GREEN PIN 3 BLACK PIN 4 YELLOW PIN 5 WHITE Black Red Yellow PUR 6x0.34 cable Green White 00 30

FULL REDUNDANT VERSION Gefran GIB tilt sensor is designed to be double mounted with specific spacers (BUS027) in order to have a full redundant space-saving version. Please pay attention how to install the two GIB sensors: please position them both always face up or both face down. Example of AMP FULL REDUNDANT VERSION SINGLE AXIS DUAL AXIS AMP Superseal 6 pole 28208- connector Mated with connector AMP 282090-3 x Spacer BUS027 CONNECTIONS. GROUND 2. + SUPPLY 3. OUTPUT X 4. OUTPUT Y 5. n.c. 6. n.c. CAN CONNECTIONS. GROUND 2. + SUPPLY 3. n.c. 4. n.c. 5. CAN L 6. CAN H ITEMS MARKED n.c. SHOULD NOT BE CONNECTED MECHANICAL DIMENSIONS Face up 3x - 0 Metal insert Maximum torque: 2.5mm 32 4

AUTOZERO FUNCTION (additional function) available for analog versions in GIB-XY configuration (dual axis) To activate the Autozero function make sure that: - sensor is powered - fixing surface is free of dust or grease - sensor is fixed on the horizontal plane with suitable screws ATTENTION! The Autozero function can be defined within a maximum range of +/- 4.5 from the original zero position (factory set). Hold the magnetic pen (accessory to order-pkit32) to the ZERO POINT label 2. Hold the position for at least 3-5 seconds so that the operation is successful. indicated on the product 2

FUNCTIONS: SENSOR OUTPUT GRAPH DUAL AXIS TILT SENSOR (XY) - X AXIS DUAL AXIS TILT SENSOR (XY) - Y AXIS 20mA A A2 A3 CLAMP HIGH 4.5 V 0 V 20mA A A2 A3 CLAMP HIGH 4.5 V 0 V 2mA 2.5 V 5 V 2mA 2.5 V 5 V 4 ma Level diagnosis (A-A3 Models) 0.5 V 0 V 4 ma Level diagnosis (A-A3 Models) 0.5 V 0 V -45 0 +45-45 0 +45 SINGLE AXIS TILT SENSOR (±80 ) - Z AXIS 20mA A A2 A3 CLAMP HIGH 4.5 V 0 V 2mA 2.5 V 5 V 4 ma Level diagnosis (A-A3 Models) 0.5 V 0 V -80-90 0 +90 +80 LOAD CONDITIONS +0.5Vdc...+4.5 Vdc output with power +0...36Vdc and +0..0Vdc output with power +..36Vdc: it is recommended a load resistance > 00 KΩ +0.5Vdc +4.5 Vdc output with power +5 Vdc: it is recommended a load resistance > 0 KΩ +4...20 ma output with power < 5Vdc up to 0Vdc: the maximum load resistance is admissible 200Ω +4...20 ma output with power > 5Vdc up to 36Vdc: the maximum load resistance is admissible 500Ω

ORDERING CODE GIB - SINGLE/DUAL AXIS ENTRY LEVEL TILT SENSOR (XY/360 ) ELECTRICAL CONNECTIONS AMP Superseal 6P connector output A Cable output (specify cable length) F CERTIFICATE 0 No certificate attached L Linearity curve to be attached AXIS TYPE Dual axis (XY axis) O Single axis (Z axis) V MEASURING RANGE measuring range (indicate) ±0 ±5 ±20 ±30 ±45 ±60 ±85 XXX (single axis Z for analogue output-dual axis XY); 360 (±80 ) for single Z axis only MEASURING RANGE (NOT available) (redundant option NOT available) 000 SUPPLY VOLTAGE +5Vdc (only for A output) L +0 +36Vdc (see output signal for right supply voltage) H ACCESSORIES X No accessories Magnetic pen Y (PKIT32) 3x spacers for redundant version A (BUS027) CABLE LENGTH 0 cable 00 mm 02 cable 200 mm 05 cable 500 mm 0 cable m 20 cable 2 m --- other lengths on request OUTPUT TYPE +0.5 +4.5Vdc output (available with supply L = ratiometric output A and with supply H = 0.5...4.5V output) 0...+0Vdc output (powered at +...+36Vdc) A2 4...20mA output (powered at +0...+36Vdc) A3 CANopen output (powered at +0...+36Vdc) C CABLE Cable without connector (always 0 in case of GIB-A version) 0 Cable (00mm) + M2 5 pin male overprinted connector EXAMPLE OF DESCRIPTION: GIBFV360000HA30 0000X0 GIB F V 360 000 H A3 0 0 000 X 0 cable only 4..20mA output +0..36Vdc cable 00 mm ND no accessories 360 special execution single axis no certificate attached cable output GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice GEFRAN spa via Sebina, 74 25050 PROVAGLIO D ISEO (BS) - ITALIA tel. 0309888. - fax. 0309839063 Internet: http://www.gefran.com DTS_GIB_05-207_ENG