CERTIFICATE OF ACCREDITATION

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Accredited Laboratory

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

PROMPT ENGINEERING P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Welcome to Garber C O R P O R AT E O V E R V I E W

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

Re: Extension for ISO/IEC 17025: 2005 accreditation Certificates #ACT-1997, ACT , ACT & AT

Certificate of Accreditation

Laboratory Accreditation Programmes

Institute for Design of Electrical Measuring Instruments, Swatantryaveer Tatya Tope Marg, Chunabhatti, Sion, Mumbai, Maharashtra

Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

Hi-Tech Calibration, 307, 3rd Floor, Govinda Complex, Char Rasta, Vapi, Gujarat. Discipline Mechanical Calibration Issue Date

Certificate of Accreditation

CERTIFICATE OF ACCREDITATION

Certificate of Accreditation

Page : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

Calitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra

Accurate Labs, 311, 312 Govinda Complex, GIDC Char Rasta, Vapi, Valsad, Gujarat. Discipline Mechanical Calibration Issue Date

QA Tech (A Division of GMP Technical Solutions Pvt. Ltd.), L-73, Verna Industrial Estate, Verna Salcette, Goa

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. SCHAP LABORATORY SERVICES, LLC Taft Road, Unit 5 Spring Lake, MI Erik Johnson Phone:

Alcalab Private Limited, 3rd Floor, Ashiana Trade Centre, Adityapur, Jamshedpur, Jharkhand. Discipline Mechanical Calibration Issue Date

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELECTRICAL

Accurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument

Q-Tech Engineering Services, S-134, C/o, Precision Engineering Works, MIDC, Bhosari, Pune, Maharashtra

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

CALIBRATION SYSTEM CERTIFICATE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

CERTIFICATE OF ACCREDITATION

Autocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

For the National Voluntary Laboratory Accreditation Program

Discipline Mechanical Calibration Issue Date Certificate Number C-0752 Valid Until Last Amended on - Page 1 of 6

A.A. Calibration Pvt. Ltd., 13-C/18, Vasundhara Haat, Vasundhara, Ghaziabad, Uttar Pradesh. Discipline Mechanical Calibration Issue Date

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION

TRI-STATE INSTRUMENT SVC, INC

Cal-Tech Calibration Services Pvt. Ltd., Flat No.8, Avadhut Heights, Anand Nagar, Sinhgad Road, Pune, Maharashtra

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Discipline Mechanical Calibration Issue Date Certificate Number C-0393 Valid Until Last Amended on - Page 1 of 6

SAFETY AND COMPLIANCE TESTING FOR SURESTOP

Discipline Mechanical Calibration Issue Date Certificate Number C-0208 Valid Until Last Amended on

REQUEST FOR QUOTATION

Date of Initial Accreditation Latest Date of Issue

Caliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra

ICL Calibration And Testing Services, SCO - 37, Ground Floor, Sector-12, Panchkula, Haryana. Discipline Mechanical Calibration Issue Date

Central Mechanical Engineering Research Institute, Mahatma Gandhi Avenue, Durgapur, West Bengal

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

Hellenic Accreditation System. Annex F2/17 to the Certificate No SCOPE of ACCREDITATION

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC & KS Q ISO/IEC

F-1500 SERIES INSERTION TURBINE FLOW METER

HD110C Heavy-Duty Digital Multimeter

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

DH50 SERIES. DATASHEET Rev. A

ASC300. Advanced Signal Calibrator. Process signal calibrator with superior accuracy. Specification Sheet

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Certificate of Calibration

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments

CERTIFICATE OF ACCREDITATION

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Deutsche Akkreditierungsstelle GmbH

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

NPI Qualification Test Report

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Model ½ Digit Multimeter

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

TEST AND CALIBRATION SERVICES Ensuring quality and reliability.

CERTIFICATE OF ACCREDITATION

Transcription:

CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Garber Metrology Weighing Solutions & Precision Calibration 520 E. Oregon Road Lititz, PA 17543 has been assessed by ANAB and meets the requirements of international standard ISO/IEC 17025:2005 and national standard ANSI/NCSL Z540-1-1994 while demonstrating technical competence in the field(s) of CALIBRATION Refer to the accompanying Scope(s) of Accreditation for information regarding the types of calibrations to which this accreditation applies. AC-1255 Certificate Number ANAB Approval Certificate Valid To: 01/26/2017 Version No. 004 Issued: 02/24/2016 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated January 2009).

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 Garber Metrology Weighing Solutions & Precision Calibration 520 E. Oregon Road Lititz, PA 17543 Vasant Amin www.garbermetrology.com vamin@garbermetrology.com Phone: 717 393 1708 CALIBRATION Valid to: January 26, 2017 Certificate Number: AC-1255 I. Electromagnetic - DC/Low Frequency PARAMETER/ DC Voltage - Source Up to 330 mv 330 mv to 33 V (33 to 100) V 100 V to 1 kv 0.02 mv/v + 3 µv 1.9 mv/v + 5 µv 11 mv/v + 50 µv 0.16 V/V + 1.5 mv DC Current - Source Resistance - Source Up to 1 ma (1 to 10) ma (10 to 100) ma 100 ma to 1 A (1 to 10) A Up to 10 Ω (10 to 100) Ω 100 Ω to 1 kω (1 to 100) kω 100 kω to 1 MΩ (1 to 10) MΩ 2 µa/a + 50 na 3 µa/a + 0.25 µa 22 µa/a + 3.3 µa 0.66 ma/a + 44 µa 5.5 ma/a + 0.33 ma 0.9 mω/ω + 8 mω 0.3 mω/ω + 15 mω 0.2 mω/ω + 60 mω 0.2 mω/ω + 6 Ω 0.2 mω/ω + 55 Ω 0.1 mω/ω + 0.55 kω Capacitance - Source Up to 1 nf (1 to 100) nf 100 nf to 1 µf 0.02 nf/f + 10 pf 0.35 nf/f + 100 pf 3.7 nf/f + 1 nf Version 004 Issued: 02/24/2016 Page 1 of 9

AC Voltage - Source AC Current - Source (1 to 330) mv (10 to 50) khz (50 to 100) khz 330 mv to 10 V (10 to 50) khz (10 to 100) V 100 V to 1 kv (29 to 190) µa (190 to 329) µa 329 µa to 3.3 ma (3.3 to 330) ma 330 ma to 2 A (2 to 10) A 0.16 mv/v + 20 µv 0.18 mv/v + 20 µv 0.18 mv/v + 20 µv 0.46 mv/v + 20 µv 0.46 mv/v + 33 µv 0.38 mv/v + 2.5 mv 0.39 mv/v + 0.60 mv 1.4 mv/v + 2.6 mv 1.8 mv/v + 5 mv 0.49 mv/v + 6.6 mv 0.50 mv/v + 15 mv 2.0 mv/v + 33 mv 0.48 mv/v + 80 mv 0.47 mv/v + 0.10 V 1.8 mv/v + 0.50 V 0.37 µa/a+ 0.15 µa 0.49 µa/a + 0.25 µa 0.53 µa/a + 0.30 µa 0.64 µa/a + 3 µa 0.12 ma/a + 3 µa 0.12 ma/a + 3 µa 15 µa/a + 3 µa 1.2 ma/a + 30 µa 1.2 ma/a + 30 µa 1.2 ma/a + 0.30 ma 1.2 ma/a + 0.30 ma 0.12 A/A + 2 ma 0.12 A/A + 2 ma Version 004 Issued: 02/24/2016 Page 2 of 9

Oscilloscopes - Amplitude 0 VDC - 50 Ω load 6 VDC - 50 Ω load 0 VDC - 1 MΩ load 66 VDC - 1 MΩ load 130 VDC - 1 MΩ load 12 mv 12 mv 12 mv 43 mv 76 mv Oscilloscopes - Flatness 50 khz ref to 10 mv p-p 50 khz ref to 5 V p-p 100 khz to 30 mv 100 khz to 5.5 V 300 MHz to 30 mv 300 MHz to 5.5 V 600 MHz to 30 mv 600 MHz to 5.5 V 0.30 mv 96 mv 0.76 mv 0.13 V 0.76 mv 0.13 V 1.3 mv 0.26 V Oscilloscopes - Rise Time (V p-p) 400 ps 1 MHz, 1 V 400 ps 10 MHz, 0.5 V 400 ps 10 MHz, 1 V 28 ps 28 ps 28 ps & Fluke 5522A for Flatness Oscilloscopes - Square Wave 1 MΩ Load 100 mv to 10 khz 1 V to 10 khz 10 v to 10 khz 2.2 mv 31 mv 1.1 V Square Wave 50 Ω Load 100 mv to 10 khz 1 V to 10 khz 5 V to 10 khz 3.9 mv 38 mv 87 mv Oscilloscopes - Time Markers 2 ns 20 ms 50 ms 5 s` 0.01 ns/s 0.01 ms/s 0.01 ms/s 0.03 s/s Electrical Simulation of Thermocouples Source Type E -10 50 1 00 Version 004 Issued: 02/24/2016 Page 3 of 9

Electrical Simulation of Thermocouples Source (cont.) Type J -15 375 C 75 0.35 C Type K -18 80 1 30 0.35 C Type T Electrical Simulation of Thermocouples Measure Type E -10 20 40-10 50 1 00 Type J -15 375 C 75 0.85 C Fluke 744 Type K -18 80 1 30 Type T -10 20 40 Version 004 Issued: 02/24/2016 Page 4 of 9

AC Power DC Power Frequency Source/Measure 5-50 W @ 60 Hz 100 W @ 60 Hz 200 W @ 60 Hz 390 W @ 60Hz 550 W @ 60 Hz 900 W @ 60 Hz 100 W @ 400 Hz 100 W @ 1 khz 100 W @ 5 khz Up to 10 W (20 to 50) W 100 W (200 to 900) W Up to 100 Hz 100 khz (1 to 10) MHz 20 MHz to 1 GHz 3.7 mw 7.3 mw 15 mw 24 mw 24 mw 24 mw 2.7 mw 2.7 mw 2.7 mw 0.38 mw 2.5 mw 3.8 mw 26 mw 47 nhz 17 nhz 24 nhz 17 nhz 5.8 Hz Rubidium MS-1009B & Marconi 2022A II. Thermodynamic PARAMETER/ Temperature Microbath and Drywell Calibrators RTD and Thermocouple Probes (4 wires measure) RTD and Thermocouple Probes (3 wires measure) RTD and Thermocouple Probes (Source) (0 to 260) C (-5 to 140) C 0.60 C 0.35 C (-200 to 660) C 0.35 C -180 C 100 C 780 C -180 C 100 C 780 C -180 C 100 C 780 C 0.37 C 0.37 C 0.37 C 0.37 C 0.37 C 0.18 C 0.18 C 0.18 C Hart Microbath 6102 Hart Scientific 9105 Drywell HP 3458A and RTD Probe RTD Probe, 9105 Drywell Calibrator, 9173 Drywell Calibrator, 6102 Microbath, HP 3458A Version 004 Issued: 02/24/2016 Page 5 of 9

III. Mechanical PARAMETER/ Pressure and Vacuum (0 to 300) psi 50 psi 100 psi 150 psi 200 psi 250 psi 300 psi Druck DPI610 Precision Pressure Calibrator Torque Up to 30 in Hg Up to 100 psi (100 to 150) psi (150 to 1 000) psi (1 000 to 10 000) psi Up to 100 in oz Up to 250 ft lb Up to 600 ft lb 0.12 in Hg 0.11 psi 1 psi 1.6 psi 3.1 psi 0.32 % of reading 1.3 % of reading Precision Pressure Calibrator, Dead Weight Tester, Ametek R-110-1 Torque Calibrator CDI Sure-test 5000-ST Torque Calibrator (4 to 50) in/lb (30 to 400) in/lb (100 to 1 000) in/lb (20 to 250) ft/lb 0.01 lb 0.03 lb 0.13 lb 0.03 lb Torque Arms & Class F Weights Durometers Up to 100 units 1.2 % of full scale Triple Beam Balance Pipettes (2 to 20) µl (20 to 100) µl (100 to 1 250) µl (2 000 to 9 000) µl (9 000 to 10 000) µl 0.23 µl 0.24 µl 1.3 µl 5 µl 6.7 µl Balance, Class 1 Weights Mass (1 to 2) g (5 to 100) g 200 g 500 g 1 000 g (2 000 to 5 000) g 0.40 mg 0.41 mg 26 mg 48 mg 80 mg 80 mg Standard Weights NIST Handbook 105-1 (0.001 to 0.002) lb (0.005 to 0.2) lb (0.5 to 10) lb (10 to 50) lb 0.0000001 lb 0.000001 lb 0.0001 lb 0.001 lb Version 004 Issued: 02/24/2016 Page 6 of 9

Up to 10 g (0.1 mg) Up to 200 g (0.1 mg) (200 to 600) g (600 to 6 000)g 0.20 mg 0.34 mg 20 mg 22 mg Class 0 Weights Class 1 Weights Balances and Scales Up to 1.2 kg (0.1 g resolution) (1.2 to 2) kg (0.2 g resolution) (2 to 6) kg (0.1 g resolution) (5 to 30) kg (0.1 g resolution) Up to 2 lb (0.0002 lb resolution) Up to 5 lb (0.0005 lb resolution) Up to 10 lb (0.001 lb resolution) Up to 20 lb (0.005 lb resolution) Up to 25 lb (0.002 lb resolution) Up to 50 lb (0.005 lb resolution) Up to 100 lb (0.01 lb resolution) Up to 150 lb (0.05 lb resolution) Up to 500 lb (0.05 lb resolution) Up to 1 000 lb (0.2 lb resolution) Up to 3 000 lb (0.5 lb resolution) Up to 5 000 lb (1 lb resolution) Up to 20 000 lb (2 lb resolution) Up to 200 000 lb (20 lb resolution) 0.13 g 0.26 g 0.20 g 0.22 g 0.0004 lb 0.001 lb 0.002 lb 0.01 lb 0.004 lb 0.01 lb 0.03 lb 0.1 lb 0.1 lb 0.3 lb 0.6 lb 1.3 lb 2.6 lb 27 lb Class F Weights NIST Handbook 44 Version 004 Issued: 02/24/2016 Page 7 of 9

IV. Dimensional PARAMETER/ Gage Blocks Thread Measuring Wires Up to 1 in (1 to 4) in (4 to 10) in (10 to 13) in 3.7 µin 5.1 µin 7.8 µin 7.8 µin (4 to 120) tpi 8.8 µin (0.0002 mm) Pratt & Whitney LMU-2130 Grade 1 Gage Blocks Plain Plugs and Pins (0.004 to 1) in (1 to 4) in (4 to 12) in 6.8 µin 9.7 µin 19 µin Thread Plugs Up to 1 in (1 to 7.5) in 14 µin 60 µin Pratt & Whitney LMU-2130, Grade 1 Gage Blocks, Thread Measuring Wires Thread Rings Plain Rings Up to 1 in (1 to 4 in) (4 to 8 in) (0.04 to 1) in (1 to 4) in (4 to 12) in 19 µin 35 µin 59 µin Pratt & Whitney 18 µin 21 µin 28 µin LMU-2130, Class XXX Plain Rings Micrometers OD, ID, Bore, Depth Up to 1 in (1 to 10) in (10 to 48) in 84 µin 140 µin 170 µin Calipers Dial, Vernier, & Digital Up to 6 in (6 to 12) in (12 to 48) in (48 to 120)in 580 µin 580 µin 590 µin 880 µin Grade 2 Gage Blocks, Optical Flat Indicator Calibrators Up to 1 in 59 µin Height Gages Up to 12 in (12 to 48) in 630 µin 650 µin Version 004 Issued: 02/24/2016 Page 8 of 9

Indicators - Dial and Digital Up to 6 in (0.001 in resolution) Up to 0.5 in (0.0001 in resolution) Up to 0.05 in (0.00005 in resolution) Up to 0.02 in (0.00002 in resolution) Up to 0.01 in (0.00001 in resolution) 290 µin 140 µin 58 µin 34 µin 14 µin Grade 2 Gage Blocks, Indicator Calibrator Surface Plates - Flatness Repeatability Length Standards To (36 x 48) in To (72 x 144) in (36 x 48) in (72 x 144) in Up to 1 in (1 to 4) in (4 to 10) in 240 µin 240 µin 55 µin 55 µin 6.8 µin 11 µin 19 µin Planekators, Straight Indicators Pratt & Whitney LMU-2130, Grade 1 Gage Blocks, Electronic Height Gage Parallels Up to 4 in 9.9 µin Pratt & Whitney LMU-2130, Grade 1 Gage Blocks Optical Comparators X Up to 6 in Y Up to 6 in 900 µin 900 µin Glass Scale Standard, Check Balls Notes: 1. Calibration and Measurement Capabilities (Expanded Uncertainties) are based on approximately a 95% confidence interval, using a coverage of k=2. 2. This laboratory offers calibrations in its laboratory and on-site at customer-designated locations. Since on-site conditions are typically more variable than those in the laboratory, larger measurement uncertainties are expected on-site than what is reported on the accredited scope. 3. The use of (D) signifies the diagonal measurement of the surface plate in inches. 4. This scope is part of and must be included with the Certificate of Accreditation No. AC-1255. Vice President Version 004 Issued: 02/24/2016 Page 9 of 9