Cautions in Using The Relays 1/5

Similar documents
COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

Technical Information Solid State Relays. Glossary. Solid State Relays

DATA SHEET. Compact and lightweight, High breakdown voltage, Surface mounting type

Operation Switches Selector Chart

Safety Relay Unit G9S

Refer to CATALOG NUMBERS AND RATING. Fusing within 1 min if the current is 200% of rated current. K A B N A

Tactile Switch (Hinged Type)

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Pressure sensor with built-in amplification and temperature compensation circuit

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

No. P-KAB-001 DATE PRODUCTS DATA SHEET MICRO FUSE. Type KAB. UL/cUL approved File No.E17021 RoHS COMPLIANT LEAD FREE

Electromagnetic Buzzers

Refer to CATALOG NUMBERS AND RATING. Fusing within 1 min if the current is 200% of rated current. K A B N A

COMPACT FLAT SIZE FOR AUTOMOTIVE

COMPACT FLAT SIZE FOR AUTOMOTIVE

TURQUOISE STROKE SWITCHES

3. Block Diagram Pin Number, Function Pin No. Symbol Function 4. Environmental Conditions 1 Vin1 Ch1 Voltage Input Terminal 2,3 Vin23 Ch2,3 Voltage In

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Ordering Information. Text Surface-Mounting Signal Relay G6K

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Low-torque Basic Switch

QUASAR ELECTRONICS KIT No ELECTRONIC CAR IGNITION

LEVEL SWITCH WITH 1 FLOAT

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

CONDUCTIVE POLYMER ALUMINUM SOLID CAPACITOR

Pressure Sensor/PS-A (ADP5)

Turquoise Stroke Mini Switches

TURQUOISE STROKE SWITCHES

CTC Battery, Inc. Lithium Iron Phosphate Battery Specification

MIDDLE LOAD RELAY FOR SMART J/B

Reference Only. *B: Bulk packing also available. Inductance. Tolerance M:±20% N:±30% 0.150±25% 1.0 * * N:±30% 0.23±25% 0.8 *2 0.

Specification Approval Sheet

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

ø10 A1 Series Miniature Control Units

Type 4 Vertical Kink Short Lead. Double Outside Kink Lead (Gz Use) Type 6 Double Outside Kink Lead (Ks Use)

Reference Only. Inductance Frequency (μh) Tolerance Typ Max (MHz min.) 85 *

INDEX Section Page Number Remarks

DC-DC Converter DATA Sheet

DC-DC Converter DATA Sheet

Read and understand this manual for safely usage.

li-ion Polymer Battery Specification

DC-DC Converter DATA Sheet

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Reference Only. 1. Scope This reference specification applies to LQM2MPN_G0L series, Chip Coil (Chip Inductors).

1 Form A 5A small size power relay for interface

ø8 A8 Series Miniature Control Units

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

(M-702) No. M5-122 ITEM SPEC CONDITION 1. Rating Rated Voltage 12.0 V DC CCW 0.30 A MAX

EVS RP6020. Instruction Manual

HEAVY DUTY POWER RELAYS FEATURES

HL (AZH) LIMIT SWITCHES

Requests for Daily Care and Maintenance

li-ion Polymer Battery Specification

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

MCF3 DC86V11CT Inrush-withstand

HL (AZH) Limit Switches

High-frequency AC Method. panasonic-electric-works.net/sunx

Electromagnetic Buzzers

TV-5, TV-8 rated 10mm flat power relays Silent type is available

+Vin. -Vin PO RC ALM. Fig. 1 Connection Method

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

HL (AZH) Limit Switches

ION JET NOZZLE NIH-55

Turquoise Stroke Switches

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

RU Series Universal Relays

AM1 (NZ BASIC) SWITCHES

MCF3 25CT Inrush-withstand

Model Number Structure

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

Notice for TAIYO YUDEN products

Technical information for LFU20-Z07-3A-X2

Ratings 0402 inch size : Type ERBRD ERBRD R X 0R25 0R3 0R37 0R50 0R75 R00 R25 R50 2R00 2R50 3R00 Rated Current (A)

Notice for TAIYO YUDEN Products

ø12 A2 Series Miniature Control Units

ISTEK-C A 750V DC Contactor

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Requests for Daily Care and Maintenance

Direct Current Switch with Built-in Magnetic Blowout

Subminiature Basic Switch

Bright illumination face and snap-action switching.

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

PRODUCT SPECIFICATIONS PPD4NS SP-30-E

SL (AZ3) Micro Limit Switches

RP Instruction Manual

Lead-free glass Nickel plated brass Ceramic Tin plated copper Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* SOC NSD9 D32V [rated current]

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

MULTISTAGE MICRO EJECTORS

MEMS Gauge Pressure Sensor

RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX:

Electric Motor Controls BOMA Pre-Quiz

Technical Information Solid State Relays. Glossary. Solid State Relays

Precautions on the use of Multilayer Ceramic Capacitors

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

Specification Approval Sheet

Transcription:

Cautions in Using The Relays 1/5 Cautions for using the relay are mentioned hereafter and please read them before use. Also, in order to increase the reliability when you use the relay, confirm the actual conditions of your usage. Don t touch the relay terminal (charged parts) during the electric circulation, for you may receive an electric shock 1.CAUTION FOR HANDLING (1) Don t expose the relay in vibration and shock exceeding the specification level in order to maintain the initial performance. (2) Don t disassemble the relay You may not be able to maintain the initial performance. (3) Handling of stick packaging If a fractional amount remains, stopper as shown in the diagram is used, so that the relay will not move. If the relay moves inside the stick, it causes the problem to maintain the initial performance. 2.CAUTION CONCERNING THE COIL (1) Maximum allowable voltage The maximum allowable voltage of the coil is determined by the coil wire material, the heat-resistant temperature of the construction resin material, and the temperature rise level of the coil. Also, since the coil temperature rise differs according to ambient temperature, the maximum allowable voltage differs with ambient temperature. For further details, refer to the characteristics of the maximum allowable voltage of the respective relays. If the voltage applied to exceed the maximum allowable voltage, it may result in layer short of the coil and or burned damage, so it is necessary for you to take care. (2) Since the operate voltage normally rises by about 0.4%/degree Celsius because of the ambient temperature of the relay, when you use it in high humidity surrounding, consider carefully what is necessary to meet the terms and conditions for the actual use. Furthermore, when the voltage is applied to the relay coil, the operation voltage may occasionally rise due to heat generation of the coil itself. (3) It is fundamental that you apply the rated voltage to the coil. Also, apply square waves to the coil. (4) If you continually circulate electricity to the coil for a long time, there is a possibility of causing corrosion due to the heat resulting from a rise of the coil temperature and it may cause contact hindrance. In this case, consider using self-maintained type latching relay. (5) Latching relay <>Always connect polarity (+) and (-) as shown in the Relay Terminal Arrangement Drawing (Internal wire connection

Cautions in Using The Relays 2/5 drawing). Also, don t apply voltage to the 2 coil latching type set coil and reset coil at the same time. <>When shipping out the product, the product is in reset condition, but it may occasionally shifts to the set condition by vibration and shock during transportation. Therefore, please make sure that all parts fit properly before usage. (6) Coil electrolytic corrosion When the allowable voltage for the relay coil is relatively high, if you circulate electricity to the coil for a long time under high temperature and high humidity, electrolytic corrosion may occurs, which may occasionally cause the breaking of a wire. The following are examples of use, so take sufficient care. 3.CONTACT POINT CAUTION (1) Don t exceed contact rating, as it may cause smoke and/or fire. (2) It may occur occasionally that the life of the contact may be significantly shortened according to the kind contact load, switching frequency, ambient temperature and humidity, etc., so, confirm by the actually using circuit. (3) In case of AC load, if you conduct synchronous switching the optionally fixed phase, it will have significant affect on the switching life. As long as there is no special instruction, the switching of the AC load is at the value conducted by random phase control. (4) Micro-load When using the micro-load, since there can be significantly differences in its contact performance, confirm by use of the data or contact us. (5) Contact protection circuit When you open and/or close the inductive load of the solenoid and/or motor, there is a possibility that from hundreds to thousands of Volts of counter-electromotive force may occur and it may shorten the life of the contact significantly by arcing.examples of contact protection circuit are as follows.

Cautions in Using The Relays 3/5 Example of Contact protection circuit for inductive loads Example of circuit Remarks General standard as follows CR R(ohm) = Contact voltage(v) 0.5 to 1 C(micro Farad)=(0.5 to 1) x Contact current(a) Use a capacitor with a breakdown voltage of over 200 to 300V When inductive loads is relays or solenoides, there delay in release time. Varister Diode Diode + Zenner Controls high voltage between contact using the voltage Characteristics of varister. When inductive loads is relays or solenoides,there delay in release time. Use caution concerning the breakdown voltage of diode. Release time is more delayed than that of CR system Release time can be shortened more than Diode system. The zener voltage of Zenner diode uses the similar level of voltage as the power supply. Mount the contact protection circuit near the contact point (within 50cm). Also, avoid using the following protection circuit (6) Prohibited Circuit When a short-circuit occurs between form A contact and form B contact circuit construction at the power source, which causes short-circuiting, is prohibited and must not be used

Cautions in Using The Relays 4/5 4.USAGE ENVIRONMENT (1) Concerning ambient temperature Use within the ambient temperature range for the respective relays. If it is not used within the ambient temperature range, it will greatly affect the insulation property and/or contact life. (2) Concerning ambient humidity Use it in the atmosphere of less than 85%RH. If even sealed type relay is exposed in the atmosphere of high temperature and high humidity, it may absorb moisture with the water absorption property of plastic, and may occasionally cause the operation fault of the relay. (3) Dust and malignant gas Don t use in the atmosphere of significant level of dusts, sulfide gas (SO2, H2S) or organic gas. It causes hindrance in the operation. In such atmosphere please use the sealed type relay. However, plastics have breathing characteristics and please take sufficient care when the relay is exposed in the malignant gas for a long time. (4) Air pressure Use in the range of air pressure of 1013hPa plus-minus 20%. (5) Concerning vibration and shock Take care not to add vibration and shock to the relay exceeding the limits shown in the catalogue. Otherwise, it may cause the faulty and defective operation. (6) Influence of magnetic field If strong external magnetic field is added to the relay, it may cause the faulty operation. Therefore, take care when mounting transformers, solenoids, magnets, etc. near the relays. Also, if you mount polarized relays closely the characteristics of the relay may occasionally change by the influence of the permanent magnet housed in the relay. In such cases, please consult us. 5.CAUTIONS FOR MOUNTING RELAY ON PC BOARD (1) Mounting of relay <>Don t bend the terminals to make it self-supporting. <>If the relay is chucked during automatic mounting, please don t chuck hard the cover, for it may cause the damage and change of the characteristics. (2) Flux plating <>Take care that flux does not overflow onto the surface of the printed circuit board. <>When using flux, use non-corrosive rosin type flux. (3) Preheating <>Be sure to preheat. <>Preheating under the following terms and conditions. Temperature: Less than 100 degree Celsius Time : Within 1 minute <>Don t leave the relay in high temperature for a long time to avoid failure and characteristics changes of the relay.

Cautions in Using The Relays 5/5 (4) Soldering <>In case of automatic soldering Flow soldering is recommended. Soldering temperature: approx. 250 degree Celsius (Max. 270 degree Celsius) Soldering time Solder : within 5 seconds : JIS Z3282, H60 or H63 <>In case of manual soldering Soldering iron : 30 to 60W Iron tip temperature : approx. 300 degree Celsius Soldering time : Within 3 seconds (5) Cooling <>As soon as automatic soldering is finished, cool down by blowing wind immediately, so that the relay and/or other parts may not be deteriorated by the heat <>If you clean a sealed type relay, don t soak it in cold liquid such as cleaning fluid immediately after the soldering is finished. It may cause the damage sealing. (6) Cleaning <>Use an alcohol type cleaning agents <>Don t use trichlen, chrolothen, thinner, benzyl alcohol, etc. If such agents are used, it may cause damage of the case Avoid ultrasonic cleaning. Boiling cleaning is recommended. (7) Coating <>Take sufficient care to select coating agent in order to avoid bad affection to the relay.