FIRE TEST REPORT FH 5728

Similar documents
FIRE TEST REPORT FH 5154

FIRE TEST REPORT FH 5078

FIRE ASSESSMENT REPORT FAR 4659

ASTM E 1354 Caloric Content Determination of "3M Polyurethane Adhesive Sealant 540"

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

Comparison of Styropor and Neopor Expanded Polystyrene Foam Insulations HAI Project No. 1JJB

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

Test report no

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

Testing of Baier Plasterboard to AS/NZS (Electronic copy (PDF format) original signed by author) Materials Scientist.

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

Oxygen Bomb Calorimeter

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH

TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

Urban Wildfire Interface: Exterior Wall Wildfire Testing

Determination Of Fire Effluents From Products On Railway Vehicles

Practice Note on the Sourcing of Threaded Rod Used for Foundation Bolts

14 April 2016 Total Pages: 2. WET PENDULUM SLIP RESISTANCE Job No: M16/10016

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

EU Mutual Recognition Technical Requirements

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

Test report no

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

Test Report No

DNVGL-CP-0110 Edition March 2016

WET PENDULUM SLIP RESISTANCE Job No: M14/7986

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Test report No

Physical Scaling of Water Mist Protection of 260-m 3 Machinery Enclosure

Precision engineered to the highest Australian Standards, you ll find Ardent copper fittings and coils for just about every application. Ardent.

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

VOLUNTARY CODE OF PRACTICE FOR ELECTROMAGNETIC COMPATIBILITY (EMC) OF MOTOR VEHICLES (13 October 2014)

Mattest (Ireland) Ltd

David Fagan, Mobility Manager Paragon Mobility Pty Ltd 3/10 Tapnor Crescent, Brendale, Queensland th December, 2011.

BULDER 00 ROOMHEATER

Carl Stuart Ltd. Tallaght Business Park, Whitestown, Dublin 24. Calibration Laboratory Registration number: 270C

Mattest (Ireland) Ltd

NFPA 285 TEST REPORT. Report No.: H Test Date: June 1, Rendered to: ARCONIC ARCHITECTURAL PRODUCTS Eastman, Georgia

Ecoglo HYU Hybrid Photoluminescent Exit Signs: Compliance with NZBC F8/AS1

Test report No

Measurement Testing Plan and nvpm LTO Mass and Number Metric Development

FIRE REGULATION IN FURNITURE WORLD OVERVIEW

SAFETY AND COMPLIANCE TESTING FOR SURESTOP

Sequence VH Report Forms Version Conducted For

EU RO Mutual Recognition Technical Requirements

STS Directory Accreditation number: STS 0630

NovitaTech Engineering

HYDROGEN TEST CELLS. T. Wallner, R. Scarcelli, H. Lohse-Busch, B. Wozny. S. Miers Michigan Technological University. September 16 18, 2009

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A

Emissions Testing Report

The Advanced Rechargeable & Lithium Batteries Association Li-batteries hazards classification

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

PRODUCT EVALUATION REPORT

August 7, Mr. Stephen Kokenes Phone: Nomaco Inc. Fax: NMC Drive Zebulon, NC 27597

Lloyd s Register Type Approval System Test Specification Number GT04

} Rev.1/Add.12/Rev.6/Amend.4

Test report No

D ISB Lubricant Performance Test. Report Packet Version No. Method. Conducted For:

Zürich Testing on Fuel Effects and Future Work Programme

Classification report No K1

Technical File D3*GL*E3

European Fire Pump Listing

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

Title: WF Report No:

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX

Documentation of the component 16. June 2016 Thermal transmittance (U-value) according to BS EN ISO 6946

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition

Test report No

LEGAL REQUIREMENTS FOR TRANSPORT AND DISPOSAL OF HAZARDOUS WASTE IN THE ERA OF WASTE CLASSIFICATION

RESOLUTION MEPC.272(69) (Adopted on 22 April 2016) AMENDMENTS TO THE NOX TECHNICAL CODE 2008 NITROGEN OXIDES FROM MARINE DIESEL ENGINES

600 Amp Surge Arrester

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

DGINT/2. Flammability Reduction. Fuel tank safety. Purpose of the meeting. Review of conclusions from June 2004 workshop. Flammability Reduction

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

E/ECE/324/Rev.2/Add.104/Rev.2 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2

RATE OF HEAT RELEASE OF PLASTIC MATERIALS FROM CAR INTERIORS

Test report No

Technical Specification

Proposed Special Condition for limited Icing Clearances Applicable to Large Rotorcraft, CS 29 or equivalent. ISSUE 1

Report Number BTC 12024F

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9

NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (ACT 5 OF 2008) AS AMENDED THROUGH THE LEGAL METROLOGY ACT (ACT 9 OF 2014)

TOPAS 2130A (Draft v3)

Test report No

ANSI/BIFMA X Desk/Table Products - Tests. American National Standard for Office and Institutional Furnishings

E/ECE/324/Rev.2/Add.119/Amend.1 E/ECE/TRANS/505/Rev.2/Add.119/Amend.1

Optimization of Partial Filter Technology for Diesel Engines

Sound-absorbing spacer Sorp10

Spaceloft Insulation TECHNICAL GUIDE

INTERNATIONAL MARITIME ORGANIZATION (IMO) Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Marc ZELLAT, Driss ABOURI and Stefano DURANTI CD-adapco

Transcription:

1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5728 CONE CALORIMETER TEST AND NZBC VERIFICATION METHOD C/VM2 APPENDIX A AND NCC SPECIFICATION C1.10 PERFORMANCE OF NOVA WHITE GYPSUM CEILING TILES CLIENT USG Boral Building Products NZ 118 Savill Drive Mangere East Auckland 2024 New Zealand National Association of Testing Authorities, Australia (NATA) and International Accreditation New Zealand (IANZ) are both signatories of the ILAC Mutual Recognition Agreement. Users of test reports are recommended to accept test reports in the name of either accrediting body. PROJECT NUMBER: ISSUE DATE: PAGE: FT5728 11 May 2015 1 of 12

TEST SUMMARY Objective To conduct cone calorimeter testing and reduce the data in accordance with ISO 5660 and AS/NZS 3837 on client supplied specimens for the purposes of determination of the Group Classifications in accordance with; New Zealand Building Code (NZBC) Verification Method C/VM2 Appendix A National Construction Code (NCC) Volume One Specifications C1.10 and A 2.4 of the Building Code of Australia (BCA). Test sponsor USG Boral Building Products NZ 118 Savill Drive Mangere East Auckland 2024 New Zealand Description of test specimen The product as described by the client as Nova White, nominally 9 mm gypsum ceiling panels with a vinyl faced and foil back. Date of tests 6 May 2015. Test results For the purposes of compliance with the relevant building code documents, the following classification is considered applicable to the tested sample as described in Section 1. Building Code Document Group Number Classification NZBC Verification Method C/VM2 Appendix A 1 S NCC Specifications C1.10 and A 2.4 LIMITATION 1 The average specific extinction area was less than the 250 m 2 /kg limit. The results reported here relate only to the item/s tested. TERMS AND CONDITIONS This report is issued in accordance with the Terms and Conditions as detailed and agreed in the BRANZ Services Agreement for this work. FH 5728 11 May 2015 2 of 12

FH 5728 11 May 2015 3 of 12

CONTENTS SIGNATORIES... 5 DOCUMENT REVISION STATUS... 5 1. GENERAL... 6 1.1 Sample measurements... 6 2. EXPERIMENTAL PROCEDURE... 7 2.1 Test standard... 7 2.2 Test date... 7 2.3 Specimen conditioning... 7 2.4 Specimen wrapping and preparation... 7 2.5 Test programme... 7 2.6 Specimen Selection... 7 3. TEST RESULTS AND REDUCED DATA... 8 3.1 Test results and reduced data NZBC C/VM2... 8 3.2 Test results and reduced data NCC C1.10... 9 4. SUMMARY... 10 5. CLASSIFICATION IN ACCORDANCE WITH NZBC VERIFICATION METHOD C/VM2 APPENDIX A... 11 6. CLASSIFICATION IN ACCORDANCE WITH NCC VOLUME ONE SPECIFICATION C1.10... 11 7. NZBC CONCLUSION... 12 8. NCC CONCLUSION... 12 FIGURES Figure 1: Representative specimen (front face on left, back on right)... 6 Figure 2: Rate of heat release versus time... 10 TABLES Table 1: Physical parameters... 6 Table 2: Test results and reduced data NZBC C/VM2... 8 Table 3: Test results and reduced data NCC C1.10... 9 Table 4: Heat release rate... 10 Table 5: Report summary... 10 Table 6: NZBC Group classification and smoke extinction area... 11 Table 7: NCC Group classification and smoke extinction area... 11 FH 5728 11 May 2015 4 of 12

SIGNATORIES Author Matthew Van Atta Fire Engineer Reviewer P. C. R. Collier Senior Fire Testing Engineer IANZ Approved Signatory DOCUMENT REVISION STATUS ISSUE NO. DATE ISSUED DESCRIPTION 1 11 May 2015 Initial Issue REPORT NUMBER: ISSUE DATE: PAGE: FH 5728 11 May 2015 5 of 12

1. GENERAL The product submitted by the client for testing was identified by the client as Nova White, nominally 9 mm gypsum ceiling panels with a vinyl faced and foil back. Figure 1 illustrates a representative specimen of that tested. Figure 1: Representative specimen (front face on left, back on right) 1.1 Sample measurements The following physical parameters were measured for each specimen prior to testing. Table 1: Physical parameters Specimen ID Mass (g) Initial properties Mean thickness (mm) Overall apparent density (kg/m³) FH5728-1-50-1 77.0 9.2 837 FH5728-1-50-2 76.0 9.1 835 FH5728-1-50-3 80.0 9.2 870 FH 5728 11 May 2015 6 of 12

2. EXPERIMENTAL PROCEDURE 2.1 Test standard The tests were carried out and data reduced according to the test procedures described in ISO 5660: (2002), Reaction-to-fire tests Heat release, smoke production and mass loss Part 1: Heat release rate, and Part 2: Smoke production rate, and AS/NZS 3837:1998 Method of test for heat and smoke release rates for materials and products using an oxygen consumption calorimeter ; (the test standard). The sample preparation and test procedure were as described in 2.4 and 2.5. 2.2 Test date The tests were conducted on 6 May 2015 by Mr Matthew Van Atta at BRANZ Limited laboratories, Judgeford, New Zealand. 2.3 Specimen conditioning All specimens were conditioned to moisture equilibrium (constant weight), at a temperature of 23 2 C and a relative humidity of 50 5% immediately prior to testing. 2.4 Specimen wrapping and preparation All tests were conducted and the specimens prepared in accordance with the test standard. The spark igniter and the stainless steel retainer frame were used. All specimens were wrapped in a single layer of aluminium foil, covering the unexposed surfaces. 2.5 Test programme The test program consisted of three replicate specimens as identified in the above table, tested at an irradiance level of 50 kw/m². All tests were carried out with the specimen horizontal, and with a nominal duct flow rate of 0.024 m³/s. 2.6 Specimen Selection BRANZ was not involved in the selection of the materials submitted for testing. The test materials used were supplied to the laboratory by the client. FH 5728 11 May 2015 7 of 12

3. TEST RESULTS AND REDUCED DATA 3.1 Test results and reduced data NZBC C/VM2 Table 2: Test results and reduced data NZBC C/VM2 Material Test specimens as described in Section 1 (in accordance with ISO 5660) Mean Specimen test number FH5728-1-50-1 FH5728-1-50-2 FH5728-1-50-3 Test Date 6/05/2015 6/05/2015 6/05/2015 Time to sustained flaming s 35 37 39 37 Observations a - - - Test duration b s 1326* 766* 1468* 1187 Mass remaining, mf g 55.3 59.2 60.0 58.2 Mass pyrolyzed % 28.2% 22.1% 25.0% 25.1% Specimen mass loss c kg/m 2 2.4 1.9 2.2 2.2 Specimen mass loss rate c Heat release rate peak, average, q g/m 2.s 1.9 2.5 1.5 2.0 max kw/m 2 153.4 167.2 169.0 163.2 q avg Over 60 s from ignition kw/m 2 36.5 38.2 36.3 37.0 Over 180 s from ignition Over 300 s from ignition kw/m 2 17.8 17.1 16.9 17.3 kw/m 2 11.9 10.5 10.9 11.1 Total heat released MJ/m 2 7.2 4.2 5.9 5.8 Average Specific Extinction Area m 2 /kg 34.9 46.2 48.1 43.0 Effective heat of h MJ/kg 2.9 2.2 2.6 2.6 combustion d c, eff, Notes : a no significant observations were recorded b determined by * XO2 returning to the pretest value within 100 ppm of oxygen concentration for 10 c from ignition to end of test; d from the start of the test minutes ** 30 minutes after time to sustained flaming + value calculated using data beyond the official end of test time according to the test standard. NR not recorded FH 5728 11 May 2015 8 of 12

3.2 Test results and reduced data NCC C1.10 Table 3: Test results and reduced data NCC C1.10 Material Test specimens as described in Section 1 (in accordance with AS/NZS 3837) Mean Specimen test number FH5728-1-50-1 FH5728-1-50-2 FH5728-1-50-3 Test Date 6/05/2015 6/05/2015 6/05/2015 Time to sustained flaming s 35 37 39 37 Observations a - - - Test duration b s 416* 372* 382* 390 Mass remaining, mf g 61.4 63.9 65.1 63.4 Mass pyrolyzed % 20.3% 15.9% 18.7% 18.3% Specimen mass loss c kg/m 2 1.7 1.3 1.6 1.6 Specimen mass loss rate c Heat release rate peak, average, q kw/m 2 max q avg g/m 2.s 12.3 9.5 11.6 11.1 153.4 167.2 169.0 163.2 Over 60 s from ignition kw/m 2 36.5 38.2 36.3 37.0 Over 180 s from ignition kw/m 2 17.8 17.1 16.9 17.3 Over 300 s from ignition kw/m 2 11.9 10.5 10.9 11.1 Total heat released MJ/m 2 3.8 3.2 3.3 3.4 Average Specific Extinction Area Effective heat of combustion d, h, c eff m 2 /kg 47.7 63.6 56.0 55.7 MJ/kg 2.1 2.4 2.0 2.2 Notes : a no significant observations were recorded b determined by * average mass loss over 1 minute dropped below 150 g/m 2 ** two minutes after flameout or other signs of combustion cease *** 60 minutes have elapsed or 10 minutes without ignition c from ignition to end of test; d from the start of the test + value calculated using data beyond the official end of test time according to the test standard. NR not recorded FH 5728 11 May 2015 9 of 12

Rate of Heat Release (kw/m 2 ) 4. SUMMARY The test standards requires that the mean heat release rate (HRR) readings over the first 180 s from ignition for the three specimens should differ by no more than 10% of the arithmetic mean of the three readings. In the event of this criterion not being met, a further three specimens are required to be tested. Table 4: Heat release rate Specimen ID Average HRR over 180s from ignition FH5728-1-50-1 17.8 Arithmetic mean % difference from the arithmetic mean 3.1% FH5728-1-50-2 17.1 17.3-1.0% FH5728-1-50-3 16.9-2.0% Table 4 identifies the specimens exposed to 50 kw/m² irradiance meet the acceptance criteria. The report summary for the specimens as described in Section 1, exposed to an irradiance of 50 kw/m² is given in table below with rates of heat release illustrated in Figure 2. Table 5: Report summary Mean Irradiance Specimen (kw/m 2 ) thickness (mm) Mean Time to Ignition (s) Mean Peak Heat Release Rate (kw/m 2 ) 9.2 50 37 163.2 Average Specific Extinction Area (m²/kg) 43.0 (NZBC) 55.7 (NCC) Figure 2: Rate of heat release versus time 180 FH5728-1-50-1 FH5728-1-50-2 FH5728-1-50-3 160 140 120 100 80 60 40 20 0 0 600 1200 1800 Time (sec) FH 5728 11 May 2015 10 of 12

5. CLASSIFICATION IN ACCORDANCE WITH NZBC VERIFICATION METHOD C/VM2 APPENDIX A The following classification has been assessed in accordance with the New Zealand Building Code Verification Method C/VM2 Appendix A: Establishing Group Numbers for lining materials. Calculations were carried out according to section A1.3 for predicting a material s group number for each specimen tested. It states that If a different classification group is obtained for different specimens tested, then the highest (worst) classification for any specimen must be taken as the final classification for that material. The classification for the specimens as described in Section 1 is as follows: Table 6: NZBC Group classification and smoke extinction area Group Number Classification Average Specific Extinction Area (m 2 /kg) Sample 1 Sample 2 Sample 3 Classification 1 1 1 34.9 46.2 48.1 In accordance with Verification Method C/VM2 Appendix A, samples achieving either a Group Number classification 1 or 2, and with an average specific extinction area less than 250 m²/kg are identified with S post-script to the Group number. The tested samples recorded an average specific extinction area of 43.0 m 2 /kg which is less than the 250 m²/kg limit. 1-S 6. CLASSIFICATION IN ACCORDANCE WITH NCC VOLUME ONE SPECIFICATION C1.10 Calculations were carried out according to Specification A2.4. The classification and for smoke extinction area for the sample as described in Section 1 is as follows: Table 7: NCC Group classification and smoke extinction area Group Number Classification Average Specific Extinction Area (m 2 /kg) Specimen 1 Specimen 2 Specimen 3 Classification 1 1 1 1 47.7 63.6 56.0 The tested samples recorded an average specific extinction area of 55.7 m 2 /kg which is less than the 250 m 2 /kg limit and therefore it may be used in buildings with or without a sprinkler system complying with Specification E1.5 in accordance with Specification C1.10 Table 2. FH 5728 11 May 2015 11 of 12

7. NZBC CONCLUSION The cone calorimeter testing was carried out on the specimens as described in Section 1. For the purposes of compliance with the NZBC Verification Method C/VM2 Appendix A, the following classification is considered applicable to the material as described in Section 1. Group Number Classification 1-S 8. NCC CONCLUSION The cone calorimeter testing was carried out on the specimens as described in Section 1. For the purposes of compliance with the NCC Volume One Specification C1.10 for the Classification of Fire Performance of Wall and Ceiling Lining Materials, the following classification is considered applicable to the material as described in Section 1. Group Number Classification 1 The average specific extinction area was less than the 250 m 2 /kg limit. FH 5728 11 May 2015 12 of 12