Actuator LA23. Data sheet LINAK.COM/MEDLINE-CARELINE

Similar documents
Actuator LA23 DESKLINE. Data sheet LINAK.COM/DESKLINE

Actuator LA44. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA43. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA40. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA31. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA40. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA27. Data sheet LINAK.COM/MEDLINE-CARELINE

ACTUATOR LA28 PRODUCT DATA SHEET

Actuator LA30. Data sheet LINAK.COM/TECHLINE LINAK.COM/MEDLINE-CARELINE

Actuator LA27 HOMELINE Analogue. Data sheet LINAK.COM/HOMELINE

ACTUATOR LA31 PRODUCT DATA SHEET

Actuator LA32. Data sheet LINAK.COM/TECHLINE LINAK.COM/MEDLINE-CARELINE

Actuator LA34. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA29. Data sheet LINAK.COM/HOMELINE

product data sheet Usage: Duty cycle: Max 10% or 2 minutes continuous use followed by 18 minutes not in use Ambient temperature: +5 to + 40 C

ACTUATOR LA44 PRODUCT DATA SHEET

Battery Li-Ion BA21. Data sheet LINAK.COM/MEDLINE-CARELINE

Control Box CBJ1 / CBJ2. Data sheet LINAK.COM/MEDLINE-CARELINE

Control Box CB12. Data sheet LINAK.COM/MEDLINE-CARELINE

DESKLIFT TM DL6. Data sheet LINAK.COM/DESKLINE

LIFTING COLUMN LC2 PRODUCT DATA SHEET

Actuator LA35. Data sheet LINAK.COM/TECHLINE

ACTUATOR LA31 PRODUCT DATA SHEET

Kick & Click TM. Data sheet LINAK.COM/DESKLINE

Kick & Click TM. Data sheet LINAK.COM/DESKLINE

Actuator systems for hospital beds Perfection in movement LINAK.COM/MEDLINE-CARELINE

Actuator systems for patient lifts

ACTUATOR LA30 PRODUCT DATA SHEET

ACTUATOR LA30 WE IMPROVE YOUR LIFE. LA30 : 12/24V DC. Max. thrust 3500 N LA30L : 24V DC. Max. thrust 6000 N (LA30LK)

ACTUATOR LA30 PRODUCT DATA SHEET

Focus on marine LINAK.COM/TECHLINE

MOVE ON GO ELECTRIC! A Comparison of motion control systems: - Hydraulic - Electric

Focus on Ventilation and Farming Solutions LINAK.COM/TECHLINE

Actuator LD3. Product Data Sheet Feature

TA1. series. Comfort Motion Care Motion Auto Motion Ergo Motion. Product Segments

LIFTING COLUMN BL3 PRODUCT DATA SHEET

Actuator ID10. Product Data Sheet Feature

Actuator LA14. Data sheet LINAK.COM/TECHLINE

Better Solutions - Better Care. Product Overview LINAK.COM/MEDLINE-CARELINE

LIFTING COLUMN LC2 PRODUCT DATA SHEET

Focus on. Mining Equipment.

Actuator LA36. Data sheet LINAK.COM/TECHLINE

* depending on drive configuration at constant 24/29 V DC without load

LINEAR ACTUATOR INDUSTRIAL DUTY 10B SERIES

LINEAR ACTUATOR INDUSTRIAL DUTY 10A SERIES

LINEAR ACTUATOR INDUSTRIAL DUTY 10A/B SERIES

LINEAR ACTUATOR INDUSTRIAL DUTY LACT BALL SCREW DRIVE

LINEAR ACTUATOR INDUSTRIAL DUTY LACT ACME DRIVE SERIES

LINEAR ACTUATOR INDUSTRIAL DUTY 10A SERIES

LINEAR ACTUATOR INDUSTRIAL DUTY LACT SERIES

Preface... 4 Valid for... 5 Important information... 6 Safety instructions... 6 Manufacturer s declaration... 8

ACTUATORS POSITION SENSOR

LoadMaster 80 rodless actuator

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

TECHLINE Solar Catalogue

Electrical position feedback for actuator sizes Ø mm

1, 2, 4, 6, 8, 10 and 12 in. (50, 100, 150, 200, 254, 300 mm) for all models Clevis Ends

Pilot-Operated Proportional DC Valve Series D*1FH

SERIES PA SWING ARM CLAMPS for the Automotive Industry

SP24-09A Dynamic load capacity 09A4 - = 25 lbf 17A8 - = 75 lbf. 2. Dynamic load capacity 09A4 - = 25 lbf 17A8 - = 75 lbf

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Power Plugs for Proportional Valves (12 volt supply)

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview. 11 or 14mm drive output (Option)

Actual-position Feedback Unit. SISTO-SK-i. For Valves with Linear Actuators Stroke: 5-46 mm. Type Series Booklet

CCMT - Electrically operated valves for transcritical and subcritical CO2

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Machine elements. Pneumatic stamping unit. Toggle-lever presses

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Compact cylinders series NYD Double acting with magnetic piston, ISO M5 to G1/8 Piston Ø 20 to 100 mm

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

DLA SERIES + ACCESSORIES

SAV Electronic Valve Actuator

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

guide unit, double acting Technical details

Pressure switch hex 27

LEAB Voltage converter

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Index INDEX. Product overview Technical data... 5 RHL Sliders for RHL80: V100, V250 & V RHL

Compact electric actuators for 90 operation of 1/4 turn valves providing a range of torque outputs up to 1645 Nm.

Actuator type ABNM with Theft Protection, 0-10 V Proportional

Pneumatic cylinders, piston-ø mm Double acting with magnetic piston DIN ISO 15552

Potentiometers and sensors

Pressure Transmitters

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

MBL MOTION SOLUTIONS TILT/LIFT SYSTEM LIFT SYSTEM TILT SYSTEM LINEAR ACTUATORS

LED safety Luminaries

bar -20 C C ( C for high temperature version) 1000 mm

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Electronic Temperature Sensor ETS 300

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Key selector switches

MDC Series

RKPowerlift. Two-stage lifting column

ROOF FAN ROOFMASTER STEC

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Transcription:

Actuator LA23 Data sheet LINAK.COM/MEDLINE-CARELINE

LA23 The LA23 actuator is a small and strong push/pull actuator (up to 2500 N). The LA23 can be used in various applications where size is important. Some of the benefits the LA23 offers you are: Compact design High lifting force Exchangeable cables The standard LA23 is available for both the CARELINE and MEDLINE product ranges. Features and options: Load in push: 2500N, 1800N, 1500N, 1200N, 900N or 300N Load in pull: 2500N, 1800N, 1500N, 1200N, 900N or 300N Housing colour: Grey or black Protection class: IPX4, IPX6 Motor: 12 V DC, 24 V DC Stroke length: 20-300 mm Built-in dimensions: 110-146 mm + stroke length Positioning options: Potential free end stop signals Hall potentiometer or Hall PWM position Single Hall, Dual Hall Back fixture material: Plastic or steel Nut: Guided Safety nut: In push or pull (2500N and 1800N version only safety nut in push) Mechanical spline: Yes Built-in electrical end-stop: Yes Exchangeable cable: Yes Static safety factor: 2.5 Noise level: Max. 58.5 db(a) (At nominal voltage and with no load, according to EN ISO 3743-1) Mechanical end stop: Yes Integrated Control Yes Usage: Duty cycle: 10%, 2 minutes continuous use followed by 18 minutes not in use Usage temperature: +5 - +40 normal operating temp. -30 - +50 according to test conditions: ISO 7176-9 Storage temperature: -45 C to +70 C (according to ISO 7176-9) Compatibility: CB20, CB16, CB6S, CBJ 1/2, CBJC, CBJH, CBD4, CBD5 & CBD6*, CA30, CA40, CO61 and SMPS-T160 (for combination possibilities, please see the User Manual for SMPS-T160 on our website) * SLS must be ignored Up + Down in the CBD4, CBD5 or CBD6 when configured for LA23. * Only the 3, 6 & 12 mm versions can be configured in the CBD4, CBD5 or CBD6. * Only tested for single use. Approvals: IEC60601-1, ANSI/AAMI ES60601-1, CAN/CSA 22.2 No 60601-01. LA23IC is not approved according to the above. LA23 in combination with CBD4, CBD5 & CBD6 has no approvals. Flammability rate: Enclosure UL94-V0 LINAK.COM/MEDLINE-CARELINE

LA23 Ordering example: 23 6 1 A 0 1 0 00 250 A 4 IP degree: 4 = IPX4 6 = IPX6 Motortype: A = 12V B = 24V (Running mainly with battery (CBJ1, CBJ2, CBJH, CBJC, wheelchairs)) G = 24V (For OpenBus (CB20, CB16, CB6s)) not available with LA23IC Stroke: XXX = mm Min. 020 mm, Max. 300 mm in steps of 5 mm Recommended versions: 020 mm, 050 mm, 100 mm, 150 mm, 200 mm, 250 mm, 300 mm Positioning: 00 = No positioning 01 = Potential free end stop signals 02 = Dual Hall digital positioning 03 = Dual Hall PNP positioning 1x = Hall potentiometer feedback 2x = Hall potentiometer feedback and potential free endstop 3x = Hall PWM position feedback 4x = Hall PWM position and potential free endstop 50 = IC with standard electrical endstop - no positioning 52 = IC with Standard Single Hall Positioning 6x = IC with Hall potentiometer feedback. 7x = IC with Hall PWM position feedback Xx for more information please call LINAK Safety option: 0 = No safety options (pitch 3, 5, 6, 9, 12 or 20) 1 = Safety nut for push (pitch 3, 5, 6, 9 or 12) 2 = Safety nut for pull (pitch 6, 9 or 12) 3 = Mechanical spline without safety nut (pitch 3, 5, 6, 9 or 12) 4 = Mechanical spline with safety nut (pitch 3, 5, 6, 9 or 12)) Housing colour: 1 = Black (RAL 9005) 2 = Light grey (RAL 7035) Piston rod eye: 0 = Standard (steel) with slot (6.1 mm), eye Ø10.2 mm, incl. plastic bushings 1 = Standard (steel) with slot (6.1 mm), eye Ø10.2 mm (0231033) 2 = Standard (steel) with slot (6.1 mm), eye Ø12.3 mm (0231016) Back fixture 0 = 0 clockwise H = 60 clockwise Q = 120 clockwise rotation: A = 7.5 clockwise J = 67.5 clockwise R = 127.5 clockwise B = 15 clockwise K = 75 clockwise S = 135 clockwise C = 22.5 clockwise L = 82.5 clockwise T = 142.5 clockwise D = 30 clockwise 1 = 90 clockwise U = 150 clockwise E = 37.5 clockwise M = 97.5 clockwise V = 157.5 clockwise F = 45 clockwise N = 105 clockwise W = 165 clockwise G = 52.5 clockwise P = 112.5 clockwise Z = 172.5 clockwise Back fixture: 1 = Plastic with slot (6.1 mm), eye Ø10.2 mm (only for Standard push load) (0231017) (only for pitch 6, 9 or 12 and safety option 0 or 1 (push)) 2 = Steel with slot (6.1 mm), eye Ø10.2 mm, incl. plastic bushings 3 = Steel with slot (6.1 mm), eye Ø10.2 mm (0231034) 4 = Steel with slot (6.1 mm), eye Ø12.3 mm (0231020) Spindletype: 2 = 20 mm pitch (300 N) (only in push and safety option 0) 3 = 3 mm pitch (2500 N) 5 = 5 mm pitch (1800 N) 6 = 6 mm pitch (1500 N) 9 = 9 mm pitch (1200 N) 0 = 12 mm pitch (900 N) Actuator type: 23 = LA23

Dimensions: Back fixture orientation Option 1 Back fixture orientation Option 0 Drawing number:0234024

The built-in dimension depends upon the chosen safety option and stroke length. Please see the table below to decide upon the built-in dimension. Safety option Stroke length Spindle pitch Min. built-in Dimensions 0 = No safety option 20-49 6, 9, 12 or 20 160 0 = No safety option 20-49 3, 5 168 1 = Safety nut for push 20-49 6, 9 or 12 160 1 = Safety nut for push 20-49 3, 5 168 2 = Safety nut for pull 20-49 6, 9 or 12 172 3 = Mechanical Spline for push 20-49 6, 9 or 12 180 3 = Mechanical Spline for push 20-49 3, 5 196 4 = Mechanical Spline & safety nut for push 20-49 6, 9 or 12 180 4 = Mechanical Spline & safety nut for push 20-49 3, 5 196 0 = No safety option 50-200 6, 9, 12 or 20 110 + stroke 0 = No safety option 50-200 3, 5 118 + stroke 1 = Safety nut for push 50-200 6, 9 or 12 110 + stroke 1 = Safety nut for push 50-200 3, 5 118 + stroke 2 = Safety nut for pull 50-200 6, 9 or 12 122 + stroke 3 = Mechanical Spline for push 50-200 6, 9 or 12 130 + stroke 3 = Mechanical Spline for push 50-200 3, 5 146 + stroke 4 = Mechanical Spline & safety nut for push 50-200 6, 9 or 12 130 + stroke 4 = Mechanical Spline & safety nut for push 50-200 3, 5 146 + stroke 0 = No safety option 201-300 6, 9, 12 or 20 130 + stroke 0 = No safety option 201-300 3, 5 138 + stroke 1 = Safety nut for push 201-300 6, 9 or 12 130 + stroke 1 = Safety nut for push 201-300 3, 5 138 + stroke 2 = Safety nut for pull 201-300 6, 9 or 12 142 + stroke 3 = Mechanical Spline for push 201-300 6, 9 or 12 150 + stroke 3 = Mechanical Spline for push 201-300 3, 5 166 + stroke 4 = Mechanical Spline & safety nut for push 201-300 6, 9 or 12 150 + stroke 4 = Mechanical Spline & safety nut for push 201-300 3, 5 166 + stroke It is possible to order LA23 with extended built-in dimensions if the following requirements are fulfilled Spindle pitch = 6, 9, 12, 20 Spindle pitch = 3, 5 Spindle pitch = 6, 9, 12 Spindle pitch = 6, 9, 12 Spindle pitch = 3, 5 Safety option 0 : No safety option Safety option 2 : Safety nut pull Safety option 1 : Safety nut push Safety option 3 : Spline without safety nut Safety option 4 : Spline + safety nut push Max. built-in dimensions 730 - stroke 738 - stroke 742 - stroke 750 - stroke 766 - stroke Example: A) 6 mm pitch no safety option, stroke 200, BID can be max. (730-200) = 530 B) 3 mm pitch no safety option, stroke 20, BID can be max. (738-20) = 718

Technical specifications: Power supply Spindle pitch (mm) Load max. Push or Pull (N) Motor type *Typical speed at 0/ full load (mm/sec.) *Typical current at 0/ full load (Amp.) 12VDC 3 2500 / 2500 A: 12V 3.1 / 2.5 0.8 / 3.6 13.4 CBJ1/2, CBJH and CBJC 3 2500 / 2500 B: 24V 3.2 / 2.6 0.4 / 1.9 8.7 OpenBus TM 3 2500 / 2500 G: 24V 3.3 / 2.7 0.3 / 1.4 6.2 12VDC 5 1800 / 1800 A: 12V 5.4 / 4.2 0.8 / 3.9 13.4 CBJ1/2, CBJH and CBJC 5 1800 / 1800 B: 24V 5.4 / 4.5 0.4 / 1.9 8.7 OpenBus TM 5 1800 / 1800 G: 24V 5.6 / 4.6 0.3 / 1.4 6.2 12VDC 6 1500 / 1500 A: 12V 6.6 / 5.2 0.8 / 3.6 13.4 CBJ1/2, CBJH and CBJC 6 1500 / 1500 B: 24V 6.4 / 5.5 0.4 / 1.7 8.7 OpenBus TM 6 1500 / 1500 G: 24V 6.7 / 5.5 0.3 / 1.3 6.2 12VDC 9 1200 / 1200 A: 12V 9.9 / 7.5 0.9 / 4.0 13.4 CBJ1/2, CBJH and CBJC 9 1200 / 1200 B: 24V 9.5 / 8.1 0.4 / 1.9 8.7 OpenBus TM 9 1200 / 1200 G: 24V 9.9 / 8.1 0.3 / 1.3 6.2 12VDC 12 900 / 900 A: 12V 13 / 9.6 0.9 / 3.8 13.4 CBJ1/2, CBJH and CBJC 12 900 / 900 B: 24V 12.6 / 10.4 0.4 / 1.9 8.7 OpenBus TM 12 900 / 900 G: 24V 13.3 / 10.7 0.3 / 1.4 6.2 12VDC 20 300 / 300 A: 12V 21.5 / 18.6 0.8 / 4.3 - CBJ1/2, CBJH and CBJC 20 300 / 300 B: 24V 21.6 / 20.2 0.4 / 2.3 - OpenBus TM 20 300 / 300 G: 24V 21.8 / 20.6 0.3 / 1.6 - * Typical values, measurements are made with an actuator in connection with a stable power supply. The typical values can have a variation of ± 20% on the current values and ± 10% on the speed values. Inrush current (Amp) Safety nut and steel back fixture overview Pitch (mm) Load (N) Safety nut Steel back fixture Plastic back fixture 20 300 Not an option Required in pull Only in push 12 900 Optional in push or pull Required in pull Only in push 9 1200 Optional in push or pull Required in pull Only in push 6 1500 Optional in push or pull Required in pull Only in push 5 1800 Optional in push (Safety nut 2500N not available in pull) Always required Not available 3 2500 Optional in push (Safety nut 2500N not available in pull) Always required Not available Self-locking specifications Spindle pitch Without short circuit With short circuit 20 mm pitch 100 300 12 mm pitch 750 900 9 mm pitch 750 1200 6 mm pitch 1200 1500 5 mm pitch 1600 1800 3 mm pitch 2500 2500

Copyright LINAK 2018.08. MA M9-02-358-Y Chapter 5.15 Terms of use The user is responsible for determining the suitability of LINAK products for specific application. LINAK takes great care in providing accurate and up-to-date information on its products. However, due to continuous development in order to improve its products, LINAK products are subject to frequent modifications and changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products. While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK. All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof, please contact LINAK. FOR MOUNTING INSTRUCTIONS AND GUIDANCE IN USAGE, PLEASE SEE THE RELEVANT USER S MANUALS