Multi Key Solenoid Controlled Switch User Manual - Original Language Version

Similar documents
KSS Solenoid Controlled Switch

Multi Key Powersafe Electrical Switch User Manual - Original Language Version

Motion Sensing Interlock User Manual - Original Language Version

Dual Key Claw Interlock User Manual - Original Language Version

Sliding Door Interlock User Manual - Original Language Version

Motion Sensing Interlock User Manual - Original Language Version

Bolt Interlock with Safety Switch User Manual - Original Language Version

Dual Key Access Interlock with Safety Switch User Manual - Original Language Version

Multi Key Bolt Interlock with Safety Switch User Manual - Original Language Version

Access Interlock with Safety Switch User Manual - Original Language Version

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

KSUPS + Solenoid Controlled Switch

Modular Ball Valve Interlock User Manual - Original Language Version

Access Interlock with Safety Switch User Manual - Original Language Version

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Door Locks Overview of new products now available in the mgard range

Peristaltic Cased Tube Pumps

MKey9-series Safety Interlock Switch with Guard Locking

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

Data Sheet. AmLok.

BMRX Series ROTARY LEVEL CONTROL

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

BMRX Series Rotary Level Indicator

RELAY BOX PRODUCT MANUAL IMPORTANT

HYDRAULIC QUICK HITCH

HIB Enclosed Inverter User Guide

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Prevents Unscheduled Truck Departures

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Operating Instructions

Kirk Key Interlock Company

Rental Industry Safety Tester Safe Check 5s

D o o r I n t e r l o c k s

F3S-TGR-KHL1/-KHL3/-KHL3R

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Safety door-handle system STS

Safety switches with solenoid and separate actuator

Operating Instructions

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Application Guide. Total Access & Control

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Safety switches with solenoid and separate actuator

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

SD SERIES - SPECIFICATION DATA SHEET

Safety switches with solenoid and separate actuator

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Technical Data. Dimensions

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

EStrong-series Emergency Stop

MONITORED HYDRAULIC VALVE SYSTEMS

Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Elmdene International Ltd

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

Sense7-series Non-contact coded safety switch

INSTRUCTION MANUAL (ATEX / IECEx)

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

INSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

Instruction Manual. Sewage lifting station compli 300

CAUTION CM-SE CM-S21 CM-S41

Installation and Operating Instructions

Grant Grid-Connected Inverter For Grant Solar PV Systems. Installation & User Instructions

Solenoid interlock AZM 200 The non-contact interlock.

Battery Charger JCB- SCH20LI.2

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

Solenoid Actuated Diesel Engine Air Shut Down Valves

Electromagnetically actuated shotbolt lock unit G SC X... B01

Datasheet. Electrical Switching / Locking

MODEL 422 Submersible Pump Controller

Single Phase Electronic Speed Controllers

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Operating instructions Solenoid interlock AZM 170

Model LA 4300 Time Delay OFF Controller

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

OPERATING MANUAL C-1350 CABLE PUSHER. Copyright 2003 by CBS Products (KT), Ltd

Unified requirements for systems with voltages above 1 kv up to 15 kv

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

2 Ton - 50 Ton Bottle Jack

VA-7450 Series. Electric Valve Actuators

SKORPION Trapped Key Interlocking with Key Exchange THE SKORPION RANGE - AVAILABLE IN STAINLESS STEEL 316 OR DIE CAST:

MICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series Issue 2. Datasheet

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Transcription:

E20-FSS-3D-F-C/O4-110A The KSSE is a solenoid controlled, multi-key electrical switch for the controlled isolation of low current. This product is used where the controlled isolation of a machine needs to take place, i.e. where a robot has to finish a cycle prior to isolation and where multiple entry points to the protected area are required. The solenoid is continuously rated, and its position is electrically monitored. This type of isolator should be used for short term, off load isolation. The unit is supplied capable of being mounted into an existing panel or for surface mounting within its own IP65 rated lockable steel enclosure. The KSSE is manufactured from either brass or stainless steel making it ideal for use in standard or harsh corrosive environments. Operation Castell multi key solenoid controlled switches are typically used for machine isolation in applications where a machine has to finish a cycle prior to isolation. KSSE multi key solenoid controlled switch, exchange key condition 1 Isolation Key is free while power is on, solenoid is de-energised. Personnel keys are trapped. 2 Insert and turn isolation key to switch power off. Once external signal is received (LED illuminates), push the button to de-energize the solenoid and release personnel keys. 3 Power is off, isolation key is trapped and personnel keys are free. 1. While the isolation key is free, the power is on. Personnel keys are trapped. 2. By inserting and turning the isolation key in the KSSE, the contact condition changes switching the power off. Once the machine has finished the cycle, a signal is sent to the KSSE to energise the solenoid and an LED illuminates. The personnel keys can now be released by pushing the button. These keys can be taken by personnel to unlock the doors in the machine area. 3. The Isolation Keys stay trapped ensuring power is off until all personnel keys are replaced in the KSSE unit. 1 of 7

Operation KSSE multi key solenoid controlled switch, double key condition 1 All keys are trapped while power is on, solenoid is de-energised. 2 Turn and release all keys to change the condition of the contacts interrupting power supply. Once external signal is received (LED illuminates), push the button to energize the solenoid and release the keys. 3 While all keys are free, the power supply is interrupted. 1. While all keys are trapped, the switch for the main power supply is closed enabling the power supply. 2. By turning and releasing the keys, the contacts condition changes switching the power off. Once the machine has finished the cycle, a signal is sent to the KSSE to energise the solenoid and an LED illuminates. The Keys can now be released by pushing the button. These keys should be taken by the personnel to unlock the doors in the machine area. 3. The power is off until all keys are replaced in the KSSE unit and turned, switching the contact condition to open. 2 of 7

Usage The KSSE multi key solenoid controlled switch is designed to be part of a safety system and is used to isolate the power releasing a key which is then used to gain access to a hazardous area via an access interlock such as the AI, AIE or Salus. The KSSE multi key solenoid controlled switch is not designed for security purposes. No hazardous substances were used in the manufacture of this product. The product can be disposed of in standard waste. Installation Back of panel units should be mounted to a flat surface using suitable fasteners. Please refer to drawing on page 5 for more details). The lock face should be sealed to the panel for ingress protection. Cables should be connected to the switch in accordance with the applicable wiring diagrams. Ensure that the unit is bonded for earth continuity (see drawing on page 5 for more installation details). IMPORTANT: The interlock should be mounted using anti-tamper fasteners to prevent unauthorised removal. The KSSE range of multi key solenoid controlled switches must be installed by a competent and qualified person who has read and understood these instructions. Please retain this document in your technical file. Maintenance Periodic visual checks should be carried out by the site manager / safety officer. Do not lubricate lock barrel with oil or grease, use CK Dry Powder Graphite if necessary. In case of defects beeing detected please contact your nearest Castell Support Department for further actions. Please see Contact section for contact details. 3 of 7

Technical Data Temperature rating Type of mounting Weight Material Power isolation Switch approvals MTTF Certification -25 C ice free to +55 C Surface (with enclosure) or panel mount using suitable fasteners (please refer to drawing on page 4 for more details) 4 kg (2 lock portions unit) Brass/Stainless steel 20A BS,UL,CSA & VDE Available on request Application A typical application of KSSE multi key solenoid controleld switch is machine guarding. It is usually used in combination with an access interlock such as the Salus for part body access or an AIE access interlock with an exchange key for full body access control. The KSS breaks the machine safety circuit, ensuring a machine is shut down once the isolation key is inserted and turned into the unit. Once the machine has completed the cycle, an external signal is received by the solenoid, which is indicated by an illuminated LED. Activating the green button on the KSSE will enable the personnel keys to be turned and removed ensuring the power is locked out. The keys can then be taken to the AIE double key access interlocks to enable access to the machine. The machine cannot be restarted until all doors are closed, and all personnel keys returned to the KSSE multi key solenoid controlled switch. EC-Declaration KSSE Solenoid Controleld Switch AIE Access Interlocks We, the manufacturers, declare that the components, detailed herein and placed on the market, comply with all the essential health and safety requirements applying to them. Empowered signatory: Mr T.C. Whelan Managing Director 4 of 7

Drawing Dimensions: in mm Note: For safe mounting, use security screws KSSE 5 of 7

Wiring Diagram KSSE, Wiring Diagram DC KSSE, Wiring Diagram AC 6 of 7

Wiring Order Diagram Information Product Type 1 2 3 4 5 6 7 8 9 10 Part Number E - - - - - Example E 20 - FS B - 1 D - F - CC 4-110 A A1 Isolation Key Symbol B1 (exchange key condition) 11 O R 12 O R Primary Key Symbol (double key condition) Personnel Key Symbol (exchange key condition) Secondary Key Symbol (double key condition 1 Isolation 20 amps (standard) 2 Lock portion type FS (1) / Q (1) 3 Material B = Brass / S = Stainless steel 4 Secondary (additional) lock portion(s) 1 / 2 / 3 / 4 / 5 or 6 secondary lock portions 5 Key condition E = Exchange key condition / D = Double key condition (simulataneous removal of all keys) 6 Mounting P = Panel mount (back of board) / F = Front of board mount, with enclosure 7 Contacts arrangement in normal position CO = NO/NC arrangement (contacts closed/opened)/ CC = NC arrangement (contacts closed) 8 Number of contacts 4 / 6 (standard) 9 Control voltage 110 / 24 / 240 (standard) 10 Current VAC / VDC 11 Lock portion symbol: Isolation key (for exchange key condition) FS (1) up to 3 characters / Q (1) up to 6 characters Primary key (for double key condition) 12 Lock portion symbol: Personnel key (for exchange key condition) Secondary key(s) (for double key condition) FS (1) up to 3 characters / Q (1) up to 6 characters (1) FS - Lock type Q - Lock type Up to 3 characters Up to 6 characters Contact Information Special construction available upon enquiry Castell Safety International Ltd. The Castell Building 217 Kingsbury Road London, England NW9 9PQ Castell Safety International Ltd. Oskar-Jäger-Strasse 137 50825 Köln Germany Castell Interlocks Inc. Suite 800 150 N Michigan Avenue, Chicago, Illinois 60601 USA Castell Safety China Building 1, No. 123, Lane 1165, Jindu Road, Minhang District, Shanghai 201108, China. t: +44 (0) 20 8200 1200 f: +44 (0) 20 8905 9378 e: uksales@castell.com t: +49 (0) 221 1649 794 f: +49 (0) 221 1649 795 e: vertrieb@castell.com t: +1.312.360.1516 f: +1.312.268.5174 e: ussales@castell.com t: +86 21 61519023 f: +86 21 61519030 e: chinasales@castell.com 7 of 7