Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Similar documents
Multileaf damper with actuator

Type Pneumatic actuators

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Type Pneumatic actuators

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

TYPE EK-EU SMOKE CONTROL DAMPER

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Parts and characteristics

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

For installation into ductwork

Attachments. Explosion-proof actuators. For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) 09/2017 DE/en

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

VARYCONTROL VAV Dual Duct Terminal Boxes

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Technical information

Type VSD35. Nominal length up to 1500 mm: one spigot

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Grilles Linear Grilles

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

VOLUME CONTROL / REGULATING DAMPERS

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Homepage > Products > Airflow Control - VAV and CAV > Variable air volume flow control - VARYCONTROL > Control components > Type Easy.

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

Attachments. Open/Close actuators. For the opening and closing of dampers in air conditioning. 06/2017 DE/en PD OC 1

Pressure relief dampers

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

Blade Features. AirShield Control and Shut Off Dampers. AirShield

Marine Fire and Gas Dampers

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Actionair Control and Shut Off Dampers

TROX Prisliste Spjæld Riste Lyddæmpere K3-00

INDEX. Chapter1 6. air master. Volume Control Dampers

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

HEPA terminal filter units Ceiling diffusers: F640, F650, F654, F655, F656, F659, F660 Wall grilles: F670

CONTROL SMOKE AND BALANCING DAMPERS

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP

Ceiling swirl diffusers

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Circular Fire Dampers

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Particle Filter Box FKU

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

Motorized Fire Dampers

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Ventilation grilles for installation into walls, sills or rectangular

LINEAR SLOT DIFFUSERS

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Zero Leakage Isolation Damper

Ceiling swirl diffusers

Aluminium Grilles. supply, exhaust and transfer ventilation systems. flow control / equalisation & pressure regulating dampers

Grilles Linear Grilles

ARROW UNITED INDUSTRIES

Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION

Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Transcription:

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Multileaf dampers > Type JZ Low leakage Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Rectangular multileaf dampers for volume flow and pressure control as well as for low-leakage shut-off of ducts and openings in walls and ceiling slabs Maximum dimensions of steel and stainless steel variants: 2000 1995 mm; of aluminium variant: 1200 1050 mm Closed blade air leakage to EN 1751, classes 1 4, depending on variant Casing air leakage to EN 1751, class C

Aerofoil opposed action blades Closed cell side seals meet increased hygiene requirements Steel and stainless steel variants: blades interconnected by external linkage Aluminium variant: blades interconnected by gears Available in standard sizes and many intermediate sizes Optional equipment and accessories Actuators: Open/Close actuators, modulating actuators Explosion-proof construction with pneumatic actuator or spring return actuator (not for JZ-*L-AL) Powder-coated construction Aluminium variant also as anodised construction Application Multileaf dampers of Type JZ-Low leakage are used as an acting element in the volume flow and pressure control in air conditioning systems For low-leakage shut-off of ducts and openings in walls and ceiling slabs Stainless steel and powder-coated constructions with increased corrosion resistance if required Steel and stainless steel variants with brass or stainless steel bearings are suitable for use in potentially explosive atmospheres (ATEX) Special characteristics Aerofoil blades Low-maintenance, robust construction No parts with silicone Available in standard sizes and many intermediate sizes Closed cell side seals meet increased hygiene requirements

Variants JZ-LL: Multileaf damper with opposed blade action, made of galvanised sheet steel, to EN 1751, classes 3 4 JZ-HL: Multileaf damper with opposed blade action, made of galvanised sheet steel, to EN 1751, classes 1 2 JZ-LL-A2: Multileaf damper with opposed blade action, made of stainless steel, to EN 1751, classes 3 4 JZ-LL-AL: Multileaf damper with opposed blade action, made of aluminium, to EN 1751, class 4 JZ-HL-AL: Multileaf damper with opposed blade action, made of aluminium, to EN 1751, class 2 Attachments Quadrant stays and limit switches: Quadrant stays to adjust the damper blades (stepless adjustment) and for capturing the end positions Open/Close actuators: Actuators for opening and closing multileaf dampers Modulating actuators: Actuators for stepless blade adjustment Pneumatic actuators: Pneumatic actuators for opening and closing multileaf dampers Explosion-proof actuators: Actuators for opening and closing multileaf dampers installed in potentially explosive atmospheres Accessories Installation subframe: Installation subframe for the fast and simple installation of multileaf dampers TECHNICAL INFORMATION Functional description Linkage Low-leakage multileaf dampers with external linkage have opposed action blades. An external linkage transfers the synchronous rotational movement from the drive arm to the individual blades. Even very large multileaf dampers can be safely opened and closed with this type of linkage. Opposed action blades close at different speeds since the linkage includes a transverse link. This facilitates the closing process and reduces the closed blade air leakage. Gears Multileaf dampers with gears can only have opposed action blades. The internal gears transfer the synchronous rotational movement from the drive arm to the individual blades.

Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2019-01-13 TROX UK Ltd.

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Multileaf dampers > Type JZ Low leakage Rectangular multileaf dampers for volume flow and pressure control as well as for low-leakage shut-off of ducts and openings in walls and ceiling slabs. Suitable for duct pressures up to 1000 Pa. Ready-to-operate unit which consists of the casing, aerofoil blades and the blade mechanism. Flanges on both sides, suitable for duct connection. The blade position is indicated externally by a notch in the blade shaft extension. Closed blade air leakage to EN 1751, class 4. Casing air leakage to EN 1751, class C. Special characteristics Aerofoil blades Low-maintenance, robust construction No parts with silicone Available in standard sizes and many intermediate sizes Closed cell side seals meet increased hygiene requirements Technical data Nominal sizes: 200 100 mm 2000 1995 mm Differential pressure range: 5 3500 Pa Operating temperature: 0 to 100 C At tach ments Type Quadrant stays and limit switches Type Open/Close actuators Type Modulating actuators Type Pneumatic actuators Type Explosion-proof actuators Accessories Type Installation subframes Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2019-01-13 TROX UK Ltd.

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Multileaf dampers > Type JZ Low leakage TROX UK Ltd Online-Services Service-Hotlines TROX Academy Your contact partner Our Office London Our Office Thetford Sales: +44 (0)1842 754545 Contact Service: +44 (0)1842 754545 Contact Technical service +44 (0)1842 754545 Contact Caxton Way, Thetford, Norfolk, IP24 3SQ, UK Tel: +44 (0) 1842 754545 Fax: +44 (0) 1842 763051 General Enquiries info@troxuk.co.uk Sales & Customer Services sales@troxuk.co.uk Accounts accounts@troxuk.co.uk Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2019-01-13 TROX UK Ltd.