VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Similar documents
VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

OWNER`S MANUAL SMH RANGE HORIZONTAL MULTISTAGE CENTRIFUGAL PUMPS SMH35 SMH45 SMH55 SMH75 SMH90

OWNER S MANUAL SINGLE STAGE STAINLESS STEEL CENTRIFUGAL PUMPS SSS SERIES. Installation / Operation / Troubleshooting SSS702 SSS2102 SSS2103 SSS3703

OWNER S MANUAL. Horizontal Multistage Centrifugal Pumps. SMH Range

WATERPRESS BOOSTER SETS WITH 24L HORIZONTAL EXPANSION TANK. Design features

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

OWNER S MANUAL. Jet Assisted Pumps Series

FARMMASTER. JJ & OJ Series

ESE Series Cast Iron Sewage Pumps

Owners Manual: - Pumps

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

StormPro BA Series Sump Pump

OWNER`S MANUAL. 112/252, 14, 18 SERIES HI-FLO CENTRIFUGAL PUMPS High flow water transfer. Suitable for tank filling & irrigation.

FOR NEW ZEALAND. T-604 WASTE DISPOSER B. HYDRAULIC CHARACTERISTICS &TECHNICAL SPECIFICATIONS. DECLARATION OF COMPLIANCE

Matala. VersiFlow Series. Instruction and Maintenance Manual

HALLMARK INDUSTRIES INC

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

StormPro BCV400 Sewage Ejector Pump

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

Owner s Manual Drill and Light Weight Portable Utility Pumps

OPERATION & MAINTENANCE INSTRUCTIONS

Installation & Operating Manual

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol

OPERATION & MAINTENANCE INSTRUCTIONS

Installation and Operating Instructions. WHISPER Series, TYPHOON C & T-Series Swimming Pool Pumps

GeyserMax-Flow Series

Installation and Operating Instructions

MINIPOND 700/900 Mk2 THE POND MASTERS GUIDE TO. Blagdon - The Pond Masters The name you can rely on

INSTALLATION MANUAL. Installation Details Warranty Wolfen Hand Held Trigger Spray Assembly With Stop Tap

Installation and Operating Instructions for

VERSION 2017 V.1.0

ELECTRIC LIFTING HOIST

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

PRESSURE BOOSTER 150

TPAK Series COOLANT PUMP

Installation and Operating Instructions for Davey HS20-65Y2 Multistage Pump

1600 PSI ELECTRIC PRESSURE WASHER

OWNERS MANUAL ECODIVER

OWNER S MANUAL VF150 SUBMERSIBLE PUMP. An earth leakage or residual current protection device must be fitted to all installations.

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

Submersible Pump Instructions. Safety Instructions

SELF PRIMING CHEMICAL SERVICE PUMPS

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUBMERSIBLE DIRTY WATER PUMP

Domestic Water Supply Pressure Pumps

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

INSTALLATION MANUAL. Installation Details Warranty Wolfen Folding Shower Seat 600mm Wolfen Folding Shower Seat 960mm

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler

ALAPE METAPHOR UNDERCOUNTER BASIN

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

SUPER PUMP OUT SYSTEM

TPHK Series Immersible Pump

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

1/2 HP SUMP PUMP OWNER'S MANUAL

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

1100W PORTABLE GENERATOR

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

INSTALLATION MANUAL. Installation Details Warranty Wolfen Pre Rinse Sink Mixer Wolfen Compact Pre Rinse Sink Mixer

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

SUBMERSIBLE WATER PUMP

INSTALLATION MANUAL Wolfen Cleaners Sink With Grate. Installation Details Warranty

6 Litre Oil-Less Air Compressor

Instruction Manual. * We reserve the right to amend specification without prior notice.

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE PUMP HSE RANGE

1200W INVERTER GENERATOR

Instruction Manual. * We reserve the right to amend specification without prior notice.

STUDIO - TRAINING MANUAL

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

M o d e l J E U. Self Priming Jet Pump. Operating Instructions, Installation & Maintenance Manual. Ebara Fluid Handling

GARDEN HOSE UTILITY PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Installation and Operating Instructions for Davey HS20-65Y2T Multistage Pressure System with

OMEGA UNDER COUNTER MECHANICAL BTW 4S CONCEALED CISTERN

HIDEAWAY PLUS IN-WALL CISTERN (BACK TO WALL PAN)

SUBMERSIBLE PUMP HSE RANGE

MIZU QUICK CHANGE DUAL FILTER SYSTEM

Generator Set. CP Range. Operating & Maintenance Instructions 0702

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

ROCA DUO PLUS OVAL INSET BATH

ROCA KHROMA TOILET SUITE

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

ROCA THE GAP BACK TO WALL TOILET SUITE

Sump Pump. Installation and Operating Instructions

SUBMERSIBLE WATER PUMP

Installation and Maintenance Manual

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

SUBMERSIBLE WATER PUMP

INSTALLATION INSTRUCTIONS

Matson Programmable Voltage Sensitive Relay MA98411

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

Material required for drilled well application (indoor use only)

12V CONSTANT PRESSURE PUMP

Voltmaster Centrifugal Trash Pumps

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

Installation Instructions

Transcription:

PRODUCT OVERVIEW The VADA series of self priming jet pumps combine the functional benefits of centrifugal pumps and the practical and qualitative benefits of self-priming pumps. The Venturi system the pumps are fitted with guarantees optimum hydraulic efficiency and great performance under high suction lift applications CONSTRUCTION Pump Casing Motor Bracket Impeller Monobloc diffusor Venturi tube nozzle assembly Shaft Mechanical Seal Counterface Seal Holder Plate O-ring X5 CrNi 1810 (AISI 304) stainless steel Die-cast aluminium Technopolymer with stainless steel shim ring Technopolymer X12 CrNiS 1809 (AISI 416) stainless steel Graphite Ceramic Technopolymer NBR 70 Shore USAGE LIMITATIONS Type of liquid: clean water with no suspended solids or abrasive material Maximum liquid temperature: 50 O C Maximum ambient temperature: 40 O C Maximum recommended suction height: 8m with foot valve Maximum operating pressure: 6 bar MOTOR Enclosed, externally ventillated Level of protection IP44 Class F insulation Single phase power supply with capacitor permanently activated Thermal protection built into the motor winding Speed of rotation 2850 rpm Suitable for continuous use WARRANTY You have purchased a quality product from Reece Australia. This product is covered by a 24 month warranty. This warranty covers faults in the product construction, material and assembly. Faulty products will be repaired or exchanged free of charge. Faulty items become our property. This warranty does not include faults caused by Unsuitable or improper use Incorrect installation Normal wear and tear Inadequate or complete lack of maintenance Chemical, electrochemical or electrical influences To the maximum extent permitted by law, Reece excludes all warranties other than those set out above. In the event of a warranty claim, we will replace or repair defective products, or pay for the cost of having defective products repaired or replaced, but will not be liable for any injury to any person, damage to any property, any indirect or consequential loss, or in any other respect.

TABLE OF HYDRAULIC PERFORMANCE 60 50 40 30 V60-J 20 10 Hm L / 1' Q m 3 / h 20 1,2 40 2,4 60 3,6 80 4,8 100 6 120 7,2 PUMP PERFORMANCE Model Nominal power Absorbed power Voltage Amp µf Q L/1 0 10 20 30 40 50 60 70 80 HP kw HP kw m3/h 0.6 1.2 1.8 2.4 3 3.6 4.2 4.8 V60-J 0.75 0.55 1.1 0.8 1~220/240V 4 12.5 Discharge head in meters 46 36 31 26 18 6 E SUCTION PORT B OUTLET PORT C D A PUMP DIMENSIONS Model Dimensions (mm) A B C D E Suction Port Outlet Port kg Weight V60-J 374 93 140 190 178 1 F 1 F 8.2

INSTALLATION Please pay careful attention to the following warnings signs and indications. Only qualified, licensed personnel should install pump. The electrical installation shall be in accordance with the national wiring rules (AS/NZS 3000) for class 1, IP44 rated products. These instructions are a guide only. Users not familiar with pumping equipment should seek advice from people experienced in pump equipment and installation. The pump is designed to be used with clean water in a residential application. Do not use it with alternative fluids, specifically abrasive, corrosive or explosive fluids. Do not install or operate your pump in an explosive environment or near combustible matter. Incorrectly installed or tested equipment may fail, causing severe injury or property damage. Freezing conditions will damage the unit, because when water freezes it expands. Ensure that the pump is located so that it is not prone to freezing, or ensure that the product is disconnected and dried of water during cold conditions. The pump is electrically connected. Ensure that it is isolated from electrical supply during installation and any subsequent service work. Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for at least 20 minutes before trying to work on it. A thermal overload switch protects the motor from heat damage during operation. PREPARING FOR INSTALLATION Inspect your pump, ensuring that it is well packaged and has not been damaged in transport. If the pump is damaged, report it to the Reece branch where the pump was purchased. Make sure the suction piping is completely air tight and is laid so that there can be no air locks. Warranty of these pumps is void unless they are operated in accordance with these instructions. PUMP PROTECTION The pump should be protected from the weather, floods, chemicals, dust, vermin and insects. It is recommended that the pump be housed in a weather proof, well vented enclosure.

GENERAL INSTALLATION 1. Fitting and Auto Pressure Control or Mains Water Switch Over Device If you are using a Vada Auto Pressure Control or a Mains Water Switch Over Device with your pump, connect it either directly to the top of the pump or in a suitable position in line with the delivery piping. For further instructions on connecting these devices, please refer to the manual supplied with your unit. Ensure that the power lead remains disconnected until you have completed the installation process. 2. Locating the Pump Find a location for your pump as close to your water source as possible. Ensure that this location is stable, dry and on a separate footing from your home. To do this you can mount the pump on a concrete base. 3. Power Source Arrange for an electrician to install a 10A weatherproof outdoor power point near the pump if there is not one there already. 4. Suction This is the most important part of the installation as errors will cause significant problems for the system in performance and longevity. A gate valve must be installed at the water source outlet. To maintain optimum performance from your pump, the suction pipe should be: Kept to the shortest length practical. Re-enforced crush resistant (non-collapsible) hose or pipe. All fittings should be air tight. Pipes should be equal to or larger than the diameter of the suction/inlet port. When pumping from a well/pit etc. a foot valve should be installed on the suction pipe. Optional: Fitted with a suction Strainer/Filter* *In-line strainers/filters are only recommended for pumps fitted with a Vada Auto Pressure Control or a Mains Water Switch Over Device. Regular maintenance is required to keep them clean and provide maximum pump pressure. 5. Discharge The length and diameter of the discharge hoses/pipes will affect the pressure and flow rate at which your pump operates. Pressure ratings of all components must exceed the maximum pressure of the pump by an appropriate safety factor. All pipe work should be supported independently of the pump. If you want to test that the pump is operating correctly prior to having the plumbing connected, attach a hose with a trigger nozzle to the top of the pump or the connected discharge hoses/pipes. 6. Pump Priming Ensure that there is at least 200mm of water in your tank, (i.e. that the tank outlet is covered, and the pump will not draw any air into the system). Open the gate valve on the water source. Check for any leaks, and repair these if necessary. If no leaks are present, remove the priming plug to open the priming port on the top of the pump case. If the tank is above the level of the pump, water will start to run out of this port. Replace the priming plug carefully. Your pump is not ready to run. If the tank water level is below the level of the pump, you will need to fill the pump body and suction line. Remove the priming plug and fill the pump body and suction line using a funnel.

ELECTRICAL INSTALLATION In accordance with AS 3350.2.41 we are obliged to inform you that this pump is not to be used by children or infirm persons and must not be used as a toy by children The pump must be supplied by an outlet protected by a residual current device or earth leakage circuit breaker with a maximum rated residual current of 30mA The pump is supplied with: A fixed cable featuring a weatherproof IEC socket A separate power cable which features a weatherproof IEC plug and a standard Australian 10 amp plug. If connecting directly to a power outlet, simply connect the two supplied cords using the IEC socket and plug. If you are installing a Vada Auto Pressure Control or a Mains Water Switch Over Device, connect the IEC socket from the pump to the IEC plug cord on the device. Ensuring there are no water traces on the connectors push them firmly into each other to ensure intended splash (water) proof protection. This connection shall be separated again only for service purpose and only after the power supply is removed by unplugging the cord form the socket outlet. The socket outlet shall be in dry and flood free location; preferably do not use extension cords for this very reason and because they can cause voltage drop. Supply voltage outside limits specified in Model Data can cause motor overheat leading to overload tripping, reduced component life or seriously damage pump and voids warranty. For additional protection, the pump must be supplied from an outlet protected by a residual current device RCD (also known as an Electrical Leakage Circuit breaker ELCB) with a maximum rated residual current of 30mA. OPERATION The pump operator or owner must be provided with this owner s manual. This must be read before operation, and followed during operation. Ensure that your pump is filled with water before operating. The pump is designed to be used with clean water in a residential application. Do not use it with alternative fluids, specifically abrasive, corrosive or explosive fluids. Do not install or operate your pump in an explosive enviroment or near combustible matter. Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for at least 20 minutes before trying to work on it. A thermal overload switch protects the motor for heat damage during operation. DO NOT RUN PUMP DRY Ensure that your pump is primed before operating START-UP/OPERATION Open all valves in the suction and discharge lines. When the power is turned on, the pump will start to pump water. Without an Auto Pressure Control or Mains Water Switch-Over Device, the pump will continue to operate until the power is switched off. Most applications will incorporate an Auto Pressure Control or Mains Water Switch-Over Device which will stop the pump as soon as it has pressurised the system it is connected to. For instructions on operating your pump with one of these devices, please refer to the manual that came with your unit. The system is now ready for use. If no water is delivered, check the troubleshooting section.

SERVICE AND MAINTENANCE Pump should only be serviced by qualified personel. For best results, use only genuine service parts. Be sure to prime pump before starting. Liquid may be HOT, release pressure with care before servicing. To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor and remove plug from power outlet before working on pump or motor. GENERAL CARE AND MAINTENANCE Under normal conditions VADA pumps do not need any type of maintenance. In order to avoid possible failures, it is advisable to periodically check the pressure supplied and current absorption. A decrease in pressure is a symptom of wear. An increase in current absorption is a sign of abnormal mechanical friction in the pump and/or motor. If the pump is not going to be used for long periods of time it should be emptied completely, rinsed with clean water and put in a dry place. TROUBLE SHOOTING GUIDE Symptom Cause Remedy The motor will not start, no water is pumped No electricity Ensure that the pump is connected to a live outlet Motor protection tripped Defective condenser Verify the cause and reset the switch. If the thermal circuit breaker has tripped wait for the system to cool down Replace the condenser Shaft blocked Verify the cause and unblock the pump The motor runs but no water is pumped The pump is sucking air Makes sure that the joints are airtight Check that the level of liquid has not dropped below the minimum priming level. The pump rotates in the wrong direction Reset the direction of rotation The pump stops after running for a short period of time because the thermal motor circuit breaker trips The power supply does not conform with the data on the nameplate A solid object is blocking the impellers The liquid is too thick Check the voltage on the power supply cable leads Call 1800 032 566 for your nearest Reece branch Call 1800 032 566 for your nearest Reece branch. You may need a different type of pump