AIR CONDITIONERS WA14**A SERIES

Similar documents
AIR CONDITIONERS WA16 SERIES

14.5 SEER VALUE SERIES CONDENSING UNITS

13 SEER CONDENSING UNITS

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES

Rheem Value Series Two-Stage Air Conditioners

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

CONDENSING UNITS RAKB- SERIES. Seven Models

CONDENSING UNITS CLASSIC X CONDENSING UNITS RAKA- SERIES. Seven Models. Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16.

CONDENSING UNITS ACHIEVER 12 SUPER HIGH EFFICIENCY CONDENSING UNITS UAMA- SERIES. Seven Models

HEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES. Nominal Sizes 1 1 /2 to 5 Tons [5.28 to kw]

HEAT PUMPS UPKB- SERIES. Seven Models

15 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant 15PJL SERIES

HEAT PUMPS UPLB- SERIES. Seven Models

Cased/Uncased Coils For Gas And Oil Furnaces

CONDENSING UNITS UAPC- SERIES. Six Models. Cooling Capacities 23,200 to 56,500 BTU/HR [6.8 kw] to [16.6 kw]

Bosch BOVA Split System Heat Pump

Package Air Conditioners

VS6BF Series 2-4 Ton Capacity. VS4BF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 5 Ton Capacity

VS4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner. 14 SEER Residential System 1.

DS4BD-KB Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner 13 SEER Residential System 1.

FORM NO. PTZ-806 REV. 1 HEAT PUMPS

Bosch BOVA Split System Heat Pump

Ruud Achiever Series Heat Pumps

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

HCH6. Product Specifications

Ruud Achiever Series Heat Pumps

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

Rheem Classic Series. Air Conditioners

WCA4**4. Product Specifications

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

CSA6. Product Specifications. SoftSound SXC 2600

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

Rheem Classic Series. Air Conditioners

Rheem Classic Series. Air Conditioners

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

N4A6. Product Specifications

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump

TECHNICAL SPECIFICATIONS

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

Rheem Prestige Series Heat Pumps Equipped with The Comfort Control 2. System

Ruud Achiever Series Air Conditioners

Rheem Classic Series. Air Conditioners

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

VT4BF-KA/B Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton Capacity

TECHNICAL SPECIFICATIONS

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY

TECHNICAL SPECIFICATIONS

FT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System 1 1/2 5 Ton Capacity

GSC13 Split System Air Conditioner

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons

Cased/Uncased Coils For Gas And Oil Furnaces

C4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h

Ruud Achiever Series Air Conditioners

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

JS4BF-K(A,B) Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

TSA6. Product Specifications. SmartComfort TXC 5600

Rheem Prestige Series Heat Pumps equipped with the Comfort Control System

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.

FS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

ET4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. ET4BD Series R-410A High Efficiency Heat Pump WARRANTY

TECHNICAL SPECIFICATIONS WSH2BF

JS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

N4A4 C. Product Specifications

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

CASED/UNCASED COILS FOR GAS AND OIL FURNACES

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

TECHNICAL SPECIFICATIONS

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER 3 Phase Light Commercial R-410A High Efficiency Heat Pump WARRANTY

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

JS6BD-K Builder's Series

FSH1BE Series. High Efficiency Heat Pump TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 14 SEER Residential System 1 1/2 5 Ton Capacity

10+ SEER - AIR CONDITIONER

TECHNICAL SPECIFICATIONS

HSH5. Product Specifications. Quiet Comfort DXC 1500

Transcription:

FORM NO. A66-220 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light commercial applications. Painted louvered steel cabinet Easily accessible control box Condenser coils constructed with copper tubing and enhanced aluminum fins Grille/Motor mount for quiet fan operation Filter Drier (shipped not installed) WA14**A SERIES 14 SEER/11.5 EER Nominal Sizes 2-4 Tons [7.03-14.0 kw] Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.

Table of Contents TABLE OF CONTENTS Model Number Identification...3-4 Electrical & Physical Data...5 Unit Dimensions...6 Refrigerant Line Size Information...7 Performance Data...8-9 Limited Warranty...10 2 WeatherKing

Model I.D./Accessories/Compressor Air Conditioners* W A 13 24 A J 1 N A * Brand Product Category WeatherKing A - Air Conditioners 13-13 SEER 14-14 SEER SEER Capacity BTU/HR 18-18,000 [5.28 kw] 24-24,000 [7.03 kw] 30-30,000 [8.79 kw] 36-36,000 [10.55 kw] 42-42,000 [12.31 kw] 48-48,000 [14.07 kw] Major Series* Voltage Type Controls Minor Series** Option Code A - 1st Design J - 1ph, 208-230/60 C - 3ph, 208-230/60 D - 3ph, 460/60 1 - Single-stage N - Non-Communicating A - 1st Design N/A Heat Pumps (For Reference)** W P 14 24 A J 1 N A * Brand Product Category SEER Capacity BTU/HR WeatherKing P - Heat Pump 14-14 SEER 18-18,000 [5.28 kw] 24-24,000 [7.03 kw] 30-30,000 [8.79 kw] 36-36,000 [10.55 kw] 42-42,000 [12.31 kw] 48-48,000 [14.07 kw] 60-60,000 [17.58 kw] Major Series* Voltage Type Controls Minor Series** Option Code A - 1st Design J - 1ph, 208-230/60 1 - Single-stage N - Non-Communicating A - 1st Design N/A Furnace Coils (For Reference)** T C F 24 17 S T A M C A * Brand Product Category Generic C - Evap Coil F - Furn Coil H - Air-Handler Coil Type Capacity BTU/HR 24-24,000 [7.03 kw] 36-36,000 [10.55 kw] 48-48,000 [14.07 kw] 60-60,000 [17.58 kw] Width Efficiency Metering Device 14-14" 17-17.5" 21-21" 24-24.5" S- Standard Eff. M- Mid Eff. H- High Eff. T-TXV E-EEV P-Piston Major Series* A - 1st Design M - Multipoise V - Vertical only/ convertible H - Ded. Horizontal only Orientation Casing Minor Series** Option Code C - Cased U - Uncased A - 1st Design N/A WeatherKing 3

Performance Data 90%+ AFUE Gas Furnaces (For Reference)** W 92 P A 70 2 3 17 M S A Brand Series Motor Major Rev Input BTU/HR WeatherKing 92-92 AFUE 95-95 AFUE 96-96 AFUE P - PSC A - 1st Design 040-42,000 [12.31 kw] 060-56,000 [16.41 kw] 070-70,000 [20.51 kw] 085-84,000 [24.62 kw] 100-98,000 [28.72 kw] 115-112,000 [32.82 kw] Stages Air Flow Cabinet Width 1 - Single-stage 3 - up to 3 ton 5-3 1/2 up to 5 ton 14-14" 17-17.5" 21-21" 24-24.5" Configuration Nox Minor Rev M - Multi X - Low Nox S - Standard A - 1st Design 80% AFUE Gas Furnaces (For Reference)** W 80 2 V A 075 3 17 M S A Brand Series Stages Motor Major Rev Input BTU/HR WeatherKing 80-80+ AFUE 1 - Single-stage S - PSC standard A - 1st Design 050-50,000 [15 kw] 075-75,000 [22 kw] 100-100,000 [29 kw] 125-125,000 [37 kw] 150-150,000 [44 kw] Air Flow Cabinet Width 3 - up to 3 ton 4-2 1/2 to 4 ton 5-3 1/2 up to 5 ton 14-14" 17-17.5" 21-21" 24-24.5" Configuration Nox Minor Rev M - Multi Z - Down & zero clearance down flow X - Low Nox S - Standard A - 1st Design Air Handlers (For Reference)** W H 1 T 36 17 S T A N A A 000 * Brand Product Category WeatherKing H - Air Handler Stages of Airflow Motor Type Capacity BTU/HR 1 - Single-Stage P - PSC 24-24,000 [7.03 kw] 36-36,000 [10.55 kw] 48-48,000 [14.07 kw] 60-60,000 [17.58 kw] Width Coil Size Metering Device 14-14" 17-17.5" 21-21" 24-24.5" S - Standard Eff. M -Mid Eff. H - High Eff. Major Series* Controls Voltage Minor Series** T - TEV A - 1st Design N -Non-comm A - 1ph, 115/60 J - 1ph, 208-240/60 D - 3ph, 480/60 Factory Heat Cap A - 1st Design 00 - no factory heat with option code Option Code *TBD 4 WeatherKing

Electrical and Physical Data Electrical and Physical Data ELECTRICAL PHYSICAL Model Compressor Number Fan Motor Minimum Fuse or HACR Phase Outdoor Coil Refrig. Weight WA Full Load Circuit Frequency (Hz) Rated Load Locked Rotor Circuit Breaker Per 14**A Amperes Ampacity Circuit Voltage (Volts) Amperes Amperes Minimum Maximum Face Area No. Net Shipping (RLA) (LRA) (FLA) Amperes Amperes Amperes Sq. Ft. [m 2 CFM [L/s] ] Rows Oz. [g] Lbs. [kg] Lbs. [kg] 24 1-60-208/230 13.5/13.5 58.3 0.6 18/18 25/25 30/30 16.39 [1.52] 1 2805 [1324] 93 [2636] 142 [64.4] 149 [67.5] 30 1-60-208/230 11.2/11.2 54 0.68 15/15 20/20 25/25 16.39 [1.52] 1 2915 [1376] 107 [3033] 168 [75.7] 175 [71.2] 36 1-60-208/230 14.1/14.1 78 1.0 19/19 25/25 30/30 21.85 [2.03] 1 3435 [1621] 124 [3515] 194 [87.9] 201 [82.1] 42 1-60-208/230 16.0/16.0 88 2.8 23/23 30/30 35/35 21.85 [2.03] 1 3550 [1675] 144 [4082] 218 [98.8] 225 [93] 48 1-60-208/230 21.8/21.8 117 1.7 29/29 35/35 50/50 21.85 [2.03] 2 4310 [2034] 236 [6690] 267 [121.0] 274 [124.2] NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set. WeatherKing 5

Unit Dimensions Unit Dimensions Unit Dimensions Model No. WA14**A Width W Length L Height H Inches [mm] Inches [mm] Inches [mm] 24 27 5 /8 [702] 27 5 /8 [702] 24 1 /4 [616] 30 31 5 /8 [803] 31 5 /8 [803] 27 3 /8 [695] 36, 42, 48 31 5 /8 [803] 31 5 /8 [803] 35 3 /8 [899] NOTE: Illustrations show the deep drawn basepan. 6 WeatherKing

Refrigerant Line Size Information Condensing Unit Refrigerant Line Size Information System Capacity -24-30 -36-42 -48 Liquid Line Connection Size (Inch I.D.) 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] Line Size (Inch O.D.) [mm] NOTES: *Standard line size N/A = Application not recommended. 25 [7.62] Liquid Line Sizing (R-410A) Liquid Line Size Outdoor Unit Above Indoor Coil (Cooling OnlyDoes not apply to Heat Pumps) Total Equivalent LengthFeet [m] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] 150 [45.72] 25 [7.62] Liquid Line Size Outdoor Unit Below Indoor Coil Total Equivalent LengthFeet [m] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] 150 [45.72] Minimum Vertical SeparationFeet [m] Maximum Vertical SeparationFeet [m] 1/4 [6.35] 0 10 [3.05] 36 [10.97] 61 [18.59] 87 [26.52] 112 [34.14] 16 [4.88] N/A N/A N/A N/A N/A 5/16 [7.93] 0 0 0 0 0 0 25 [7.62] 28 [8.53] 22 [6.71] 15 [4.57] 9 [2.74] N/A 3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 37 [11.28] 34 [10.36] 32 [9.75] 30 [9.14] 28 [8.53] 1/4 [6.35] 0 10 [3.05] 42 [12.80] 74 [22.56] 107 [32.61] 139 [42.37] 23 [7.01] N/A N/A N/A N/A N/A 5/16 [7.93] 0 0 0 0 0 0 25 [7.62] 39 [11.89] 31 [9.45] 22 [6.71] 14 [4.27] N/A 3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 47 [14.33] 44 [13.41] 41 [12.50] 38 [11.58] 5/16 [7.93] 0 0 0 0 6 [1.83] 18 [5.49] 25 [7.62] 30 [9.14] 18 [5.49] N/A N/A N/A 3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 45 [13.72] 41 [12.50] 37 [11.28] 33 [10.06] 29 [8.84] 1/2 [12.70] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 51 [15.55] 50 [15.24] 49 [14.94] 48 [14.63] 5/16 [7.93] 0 0 0 16 [4.88] 32 [9.75] 48 [14.63] 25 [7.62] 16 [4.88] N/A N/A N/A N/A 3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 37 [11.28] 31 [9.45] 26 [7.93] 20 [6.10] 15 [4.57] 1/2 [12.70] 0 0 0 0 0 0 25 [7.62] 45 [13.72] 44 [13.41] 43 [13.11] 42 [12.80] 41 [12.50] 5/16 [7.93] 0 0 7 [2.13] 27 [8.23] 48 [14.63] 69 [21.03] 25 [7.62] 14 [4.27] N/A N/A N/A N/A 3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 41 [12.50] 34 [10.36] 27 [8.23] 20 [6.10] 13 [3] 1/2 [12.70] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 51 [15.55] 49 [14.94] 48 [14.63] 46 [14.02] Suction Line Length/Size versus Capacity Multiplier (R-410A) Unit Size 1 1 /2 Ton 2 Ton 2 1 /2 Ton 3 Ton 3 1 /2 Ton 4 Ton 5 Ton Suction Line Connection Size 3/4" [19.05] I.D. 7/8" [22.23] I.D. Suction Line RunFeet [m] 5/8" [15.88 mm] O.D. 3/4" [19.05 mm] O.D. Standard* 5/8" [15.88 mm] O.D. 3/4" [19.05 mm] O.D. Standard* 7/8" [22.23 mm] O.D. 3/4" [19.05 mm] O.D. 7/8" [22.23 mm] O.D. Standard* 7/8" [22.23 mm] O.D. 1 1 /8" [28.58 mm] O.D. Standard* 25' [7.62] Standard 50' [15.24] Standard 100' [30.48] Standard.95.95.94.97.97.97 150' [45.72] Standard.92.93.92.94.91.93.95.94.95.94.95.94.97 NOTES: *Standard line size Using suction line larger than shown in chart will result in poor oil return and is not recommended. 3 Ton Suction Line Connection is 3/4" WeatherKing 7

Performance Data Performance Data @ AHRI Standard ConditionsCooling High Sales Volume Tested Combination (HSVTC) Outdoor Unit Indoor Coil or Air Handler Total Capacity Net Sensible Net Latent SEER EER Indoor CFM [L/s] WA1424AJ1 TCFL-H*2417+RXMD-C04 24000 [7.0] 17700 [5.2] 6300 [1.8] 14 11.5 800 [377.6] 8937991 WA1430AJ1 TCF3617STA+RXMD-C04 29200 [8.6] 11200 [3.3] 18000 [5.3] 14 11.5 1000 [471.9] 8937993 WA1436AJ1 TCF3621STA+RXMD-C04 34600 [10.1] 23700 [6.9] 10900 [3.2] 14 11.5 1150 [542.7] 8937087 WA1442AJ1 TCFL-H*4821+RXMD-C04 40500 [11.9] 30200 [8.9] 10300 [3.0] 14 11.5 1400 [660.7] 8937997 WA1448AJ1 TCFL-H*4821+RXMD-C04 47000 [13.8] 34100 [10.0] 12900 [3.8] 14 11.5 1475 [696.1] 8938001 AHRI# Coil Only Ratings Outdoor Unit WA1424AJ1 WA1430AJ1 WA1436AJ1 WA1442AJ1 WA1448AJ1 Indoor Coil Total Capacity Net Sensible Net Latent SEER EER Indoor CFM [L/s] TCF2414STA+RXMD-C04 24000 [7.0] 17700 [5.2] 6300 [1.8] 14 11.5 800 [377.6] 8937051 TCF2417STA+RXMD-C04 24000 [7.0] 17700 [5.2] 6300 [1.8] 14 11.5 800 [377.6] 8937052 TCF3621HTA+RXMD-C04 30000 [8.8] 11500 [3.4] 18500 [5.4] 14 11.5 1000 [471.9] 8937065 TCF3621MTA+RXMD-C04 30000 [8.8] 11500 [3.4] 18500 [5.4] 14 11.5 1000 [471.9] 8937066 TCF3621STA+RXMD-C04 29200 [8.6] 10000 [2.9] 19200 [5.6] 14 11.5 1000 [471.9] 8937067 TCF3624HTA+RXMD-C04 30000 [8.8] 11500 [3.4] 18500 [5.4] 14 11.5 1000 [471.9] 8937068 TCF3624MTA+RXMD-C04 30000 [8.8] 11500 [3.4] 18500 [5.4] 14 11.5 1000 [471.9] 8937069 TCF3621HTA+RXMD-C04 36000 [10.6] 26000 [7.6] 10000 [2.9] 14 11.5 1200 [566.3] 8937085 TCF3621MTA+RXMD-C04 36000 [10.6] 26000 [7.6] 10000 [2.9] 14 11.5 1200 [566.3] 8937086 TCF3617STA+RXMD-C04 34600 [10.1] 25000 [7.3] 9600 [2.8] 14 11.5 1150 [542.7] 8937995 TCF3624HTA+RXMD-C04 36000 [10.6] 26000 [7.6] 10000 [2.9] 14 11.5 1200 [566.3] 8937088 TCF3624MTA+RXMD-C04 36000 [10.6] 26000 [7.6] 10000 [2.9] 14 11.5 1200 [566.3] 8937089 TCF4821MTA+RXMD-C04 42000 [12.3] 32000 [9.4] 10000 [2.9] 14 11.5 1400 [660.7] 8937106 TCF4821STA+RXMD-C04 41000 [12.0] 30900 [9.1] 10100 [3.0] 14 11.5 1375 [648.9] 8937107 TCF4824HTA+RXMD-C04 42000 [12.3] 31400 [9.2] 10600 [3.1] 14 11.5 1400 [660.7] 8937108 TCF4824STA+RXMD-C04 41000 [12.0] 30900 [9.1] 10100 [3.0] 14 11.5 1375 [648.9] 8937109 TCF4821MTA+RXMD-C04 48000 [14.1] 34800 [10.2] 13200 [3.9] 14 11.5 1550 [731.5] 8937121 TCF4821STA+RXMD-C04 48000 [14.1] 35700 [10.5] 12300 [3.6] 14 11.5 1375 [648.9] 8937122 TCF4824HTA+RXMD-C04 48000 [14.1] 34800 [10.2] 13200 [3.9] 14 11.5 1600 [755.1] 8937123 TCF4824STA+RXMD-C04 48000 [14.1] 35700 [10.5] 12300 [3.6] 14 11.5 1375 [648.9] 8937124 AHRI# 8 WeatherKing

Performance Data Performance Data @ AHRI Standard ConditionsCooling (con t.) Air Handler Ratings Outdoor Unit WA1424AJ1 WA1430AJ1 WA1436AJ1 WA1442AJ1 WA1448AJ1 Indoor Coil Total Capacity Net Sensible Net Latent SEER EER Indoor CFM [L/s] RF1P2421STAN 24000 [7.0] 17700 [5.2] 6300 [1.8] 14 11.5 800 [377.6] 8937053 RF1T2421MTAN 24000 [7.0] 17700 [5.2] 6300 [1.8] 14 11.5 800 [377.6] 8937054 WBHP-17 24000 [7.0] 17700 [5.2] 6300 [1.8] 14 11.5 800 [377.6] 8937050 WH1P2417STAN 24000 [7.0] 17700 [5.2] 6300 [1.8] 14 11.5 800 [377.6] 8937055 WH1T2417STAN 24000 [7.0] 17700 [5.2] 6300 [1.8] 14 11.5 800 [377.6] 8937056 RF1T3624MTAN 30000 [8.8] 11500 [3.4] 18500 [5.4] 14 11.5 1025 [483.7] 8937070 WBHP-21 30000 [8.8] 11500 [3.4] 18500 [5.4] 14 11.5 1000 [471.9] 8937064 WH1T3617STAN 29800 [8.7] 11800 [3.5] 18000 [5.3] 14 11.5 1000 [471.9] 8937071 WH1T3621HTAN 30000 [8.8] 11500 [3.4] 18500 [5.4] 14 11.5 1000 [471.9] 8937072 WH1T3621MTAN 30000 [8.8] 11500 [3.4] 18500 [5.4] 14 11.5 975 [460.1] 8937073 RF1P3624STAN 36000 [10.6] 26000 [7.6] 10000 [2.9] 14 11.5 1100 [519.1] 8937090 RF1T3624MTAN 36000 [10.6] 26000 [7.6] 10000 [2.9] 14 11.5 1025 [483.7] 8937091 WBHP-21 36000 [10.6] 23300 [6.8] 12700 [3.7] 14 11.5 1200 [566.3] 8937084 WH1T3617STAN 35400 [10.4] 26000 [7.6] 9400 [2.8] 14 11.5 1200 [566.3] 8937092 WH1T3621HTAN 36000 [10.6] 26000 [7.6] 10000 [2.9] 14 11.5 1200 [566.3] 8937093 WH1T3621MTAN 36000 [10.6] 26000 [7.6] 10000 [2.9] 14 11.5 1150 [542.7] 8937094 WBHP-24 41500 [12.2] 29600 [8.7] 11900 [3.5] 14 11.5 1400 [660.7] 8937105 WH1P4221STAN 41000 [12.0] 30500 [8.9] 10500 [3.1] 14 11.5 1325 [625.3] 8937110 WH1T4821MTAN 42000 [12.3] 31400 [9.2] 10600 [3.1] 14 11.5 1400 [660.7] 8937111 WH1T4821STAN 42000 [12.3] 31900 [9.3] 10100 [3.0] 14 11.5 1400 [660.7] 8937112 WBHP-24 47500 [13.9] 32200 [9.4] 15300 [4.5] 14 11.5 1400 [660.7] 8937120 WH1T4821MTAN 48000 [14.1] 34800 [10.2] 13200 [3.9] 14 11.5 1400 [660.7] 8937125 WH1T4821STAN 48000 [14.1] 34800 [10.2] 13200 [3.9] 14 11.5 1575 [743.3] 8937126 WH1T4824STAN 48000 [14.1] 34800 [10.2] 13200 [3.9] 14 11.5 1550 [731.5] 8937127 AHRI# WeatherKing 9

Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* WeatherKing will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Parts...Five (5) Years 10 WeatherKing

Notes WeatherKing 11

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. In keeping with its policy of continuous progress and product improvement, WeatherKing reserves the right to make changes without notice. PRINTED IN U.S.A. 3-16 QG FORM NO. A66-220 Supersedes Form No. G66-536 Rev. 3