ACCESSORY KIT INSTALLATION INSTRUCTIONS

Similar documents
ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only

ACCESSORY KIT INSTALLATION INSTRUCTIONS

LOW AMBIENT ACCESSORY INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

INSTALLATION INSTRUCTIONS CMH-7A LOW AMBIENT CONTROL

ACCESSORY KIT INSTALLATION INSTRUCTIONS

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

NL SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (R-410A, STYLE B)

Installation Instructions Part Numbers: CRLOWAMB018A00 THROUGH CRLOWAMB026A00

ACCESSORY KIT INSTALLATION INSTRUCTIONS

E4FH, E5FH SERIES 12 SEER HEAT PUMP

PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, COOLING SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

INSTALLATION INSTRUCTIONS DNLOWAMB015A00, DNLOWAMB016A00

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

INSTALLATION INSTRUCTIONS CMH-21 Low Ambient 460V Fan Speed Control

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

Predator Model Number Nomenclature

ACCESSORY KIT INSTALLATION INSTRUCTIONS

System 350 P352AB Electronic Pressure Control Series

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

Installation and Start-Up Instructions

ACCESSORY KIT INSTALLATION INSTRUCTIONS

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

ACCESSORY KIT INSTALLATION INSTRUCTIONS

E1RA, E2RA SERIES - 10 SEER, 1PH & 3PH HEAT PUMP- OUTDOOR UNIT

Installation Instructions

P445 Series Electronic Lube Oil Control

PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

PREMIUM SERIES 22 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

TON KW 60HZ

LX SERIES 16 SEER SINGLE SPLIT DUCTLESS, HEAT PUMP SYSTEMS (CONTAINS INDOOR AND OUTDOOR MODELS)

INSTALLATION INSTRUCTION

Installation Instructions

Installation Instructions

SAVE THESE INSTRUCTIONS

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

Package Unit Modulating Economizer Installation Instructions

H*BA SERIES, 10 SEER, 1PH & 3PH AIR CONDITIONER- OUTDOOR UNIT

DESCRIPTION FEATURES

OIL PRESSURE SAFETY CONTROLS

30A SMART ENERGY MANAGEMENT SYSTEM TM

B2HZ SERIES - 13 SEER SINGLE PACKAGED HEAT PUMPS (R-410A, STYLE A,B)

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

SPECTRACOOL Slim Fit Air Conditioners (Surface-Mount Units Only) Quick Start Operation Guide

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15, 20 & 25 TONS MODELS: J07 thru 25NC, 2-PIPE J10 thru 20ND, 4-PIPE

installation manual imagine the possibilities Accessory Heat Kit For V-AHU VHK- A Thank you for purchasing this Samsung product.

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

P70, P72, and P170 Series Controls for High Pressure Applications

Installation Instructions

WATER COOLED AIR CONDITIONING UNITS MODEL CVWSEK-060 WATER SIDE ECONOMIZER FOR CSV060B VERTICAL R-410A STYLE B R-410A

SAVE THESE INSTRUCTIONS

Installation Instructions Electric Heaters 5 20 kw

TON KW 60HZ

Installation Instructions

P66 Series Electronic Fan Speed Controls

RigMaster Power Service and Repair Manual Document # S400909

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

Copeland Screw TM Compressors

ACCESSORY KIT INSTALLATION INSTRUCTIONS

This parts list is current as of the above revision date. See for the current revision.

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

Installation Instructions


REPAIR PART INSTALLATION INSTRUCTIONS

MODELS YCAV0157, 0177, 0187, 0197, 0207, 0227, 0247 AND YCAV0267 STYLE "A"

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806

SAVE THESE INSTRUCTIONS

KE2 FanControl Installation Instructions

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s)

Installation Instructions

Installation Instructions

Q35 Series Automatic Vent Damper System

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Installation Instructions

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

R-410A KW 50HZ

Installation Instructions

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

Installation Instructions

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Replacement Parts Catalog

Installation Instructions

Transcription:

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split-System Air Conditioners HA 300, HB 360 / 480 / 600, HF-25, HL-30 / -40 / -50 Models GENERAL These split-system condensing units are designed to operate at ambient temperatures down to 40 F. This accessory will insure safe operation at ambient temperatures down to 0 F. The VFD66 control monitors the refrigerant system and will vary the condenser fan speed based on the discharge pressure. One controller is required for each fan to be controlled. Therefore, two accessory kits are required for each unit. This instruction provides all the necessary information to properly field-install a low ambient accessory on the condensing units listed in Table 1. Components that are supplied in the respective accessory are listed in Table 2, and pictured in Figure 1. TABLE 1: APPLICATION DATA FIGURE 1 - ACCESSORY COMPONENTS 102694-UAI-A-1004 ACCESSORY MODEL # VOLTAGE UNIT 2LA04702625 208/230 HA 300 2LA04702646 460 HA 300 2LA04702825 208/230 HB 360 2LA04702846 460 HB 360 2LA04702925 208/230 HB 480 2LA04702946 460 HB 480 2LA04703025 208/230 HB 600 2LA04703046 460 HB 600 The 2LA047 series low ambient accessories are intended for use with the 25-50 Ton Split System condensing units only. UPG cannot guarantee proper operation for any application of this VFD 66X controller for other equipment or applications. Contact your local branch or distributor for any application related questions. TABLE 2: ACCESSORY COMPONENTS ITEM QTY. PART NO. DESCRIPTION 1 1 1 ea 473-24615-00X VFD66X Condenser Fan Speed Control and Enclosure 2 1 ea 025-37463-000 Pressure Transducer P399BAC-1CY 3 1 ea 025-37464-000 Wire Harness Assembly WHA-P399-500C 4 1 ea 025-38411-000 Power wire Harness 5 1 ea 023-20566-000 Tee Connector 6 2 ea 021-15529-000 Screw HEX ¼-14 X.75 7 1 ea 025-09848-000 Bushing 8 6 ea 025-09607-000 Wire Tie 9 1 ea 025-37455-000 0º Degree Switch 10 2 11 3 025-37423-240 30/40 Ton Crankcase Heater 025-37424-460 30/40 Ton Crankcase Heater 2 ea 025-37474-240 25/50 Ton Crankcase Heater 025-37474-460 25/50 Ton Crankcase Heater 3 ea 025-XXXXX-XXX Fuses 1. X denotes Model number needed for application. 2. Crankcase Heaters supplied are dependent on accessory ordered. 3. Fuses supplied are dependant on accessory ordered. Improper installation, adjustment, service or maintenance can cause injury or property damage. Therefore, only a qualified installer or qualified service personnel should perform this conversion. If the unit is connected to power sources, make sure that all electrical power to the unit has been disconnected. 1. Disconnect all electrical power to the unit. 2. Remove the condensing unit control box access panel. Unitary Products Group

Before installing accessory read all of this installation instruction. 3. Install the VFD66 enclosure with the provided screws. Mounting holes are pre-punched in the top rails to locate the enclosure near the condensing unit control box. See Figure 7. FIGURE 3 - P399 PRESSURE TRANSDUCER MOUNTING NOTE: Note: This procedure must be repeated for each system. FIGURE 2 - P399 PRESSURE TRANSDUCER 5. Attach wiring harness assembly plug to (P399) transducer. See Figure 4. Route sensor wires back to VFD66 enclosure. Do not remove the plastic plugs from the transducers until they are ready to be installed. 4. Attach the pressure transducers to the connection tee (provided in accessory). The pressure transducer has a ¼ In. SAE female flare with Schrader valve depressor for mounting to the tee. See Figure 2. Hand thread the transducer to the tee. Tighten and secure the connection. Remove the Schrader valve cap from the discharge line port (provided). Hand thread the tee to the discharge line port. Tighten and secure the connection, making sure the transducer is mounted vertically. See Figure 3. Perform a leak test on fittings and connections before putting the system into operation. FIGURE 4 - WIRE HARNESS ASSEMBLY 6. Remove VFD66 enclosure lid. 7. Pass wires through the bushing (provided), using knock out located in the bottom of the VFD66 enclosure. 8. Access the VFD66 control terminal blocks. See Figure 5. Remove the terminal access cover screws. Push downward on the ventilation holes while pulling outward on the top of the terminal access cover. 2 Unitary Products Group

FIGURE 5 - VFD66 CONTROL TERMINAL BLOCKS 9. Wire transducers to the VFD66 control. See Figure 6. FIGURE 7 - FAN MOTOR #1 LOCATION NOTE: All Wiring must comply with prevailing Local and National wiring codes and ordinances. FIGURE 6 - P399 PRESSURE TRANSDUCER WIRING Cut hole in the left most bushing in the bottom of the VFD66 control. See Figure 6. Push transducer sensor wires through this bushing. Connect red wire from transducer to terminal (1) on terminal block (TB3) located on the VFD66 Control. Connect black wire from transducer to terminal (4) on terminal block (TB3). Connect white wire from transducer to terminal (2) on terminal block (TB3). Connect bare wire from transducer to the grounding terminal on VFD66 control. 10. Cut two lengths of flexible conduit (Field Supplied) to connect from the VFD66 Control to the condensing unit control box. Conduit #1 should run from the bottom of the VFD66 enclosure to the condensing unit control box, using knock outs provided. In conduit #1 insert three # 14 Gage wires marked on both ends (field supplied). Conduit #2 should run from the bottom of the VFD66 enclosure to the condensing unit control box, using knock outs provided. In conduit #2 insert shielded power cable supplied in accessory. Allow additional conduit length to remove the VFD Control enclosure from the top rail and place on side for servicing. Unitary Products Group 3

11. Wire condenser fan motor #1 to the VFD66 control. See Figures 5, 7, and the wiring diagrams in Figures 10,11 and 12. The VFD66 must be wired to operate fan motor #1. Factory installed pressure switches control fan motor #2. Disconnect wire 136/BLK from terminal (T1) on contactor (M5). Disconnect wire 137/BRN from terminal (T2) on contactor (M5). Disconnect wire 138/PR from terminal (T3) on contactor (M5). Extend wire 136/BLK to terminal (T1) on terminal block (TB2) located on the VFD66 control using wires in conduit #1. Extend wire 137/BRN to terminal (T2) on terminal block (TB2). Extend wire 138/PR to terminal (T3) on terminal block (TB2). Connect (BLK) wire of power harness to terminal (T1) on contactor (M5) and to terminal (L1) on terminal block (TB1) located on the VFD66 control using shielded cable in conduit #2. Connect (RED) wire of power harness to terminal (T2) on contactor (M5) and to terminal (L2) on terminal block (TB1). Connect (WHT) wire of power harness to terminal (T3) on contactor (M5) and to terminal (L3) on terminal block (TB1). Connect bare wire of power harness to the grounding terminal on VFD66 control. 12. Check positioning of two jumpers to assure proper operation of VFD66 control. See Figure 8. needed in the future. To install a jumper, position the jumper on both pins. See Figure 9. FIGURE 9 - JUMPER PLACEMENT ON PINS Jumper block (J9) selects maximum frequency output of the control. Remove the jumper for 50 Hz motors. Install the jumper for 60 Hz motors. Power must be removed and reapplied before frequency changes will have effect. Jumper block (J8) establishes single or dual input signal operation. NOTE: The VFD66 is factory configured to accept single input operation. Therefore, (J8) jumper should be installed on both pins for this application. Jumper blocks (J2), (J3), (J4), (J5), (J6), and (J7) are preset at the factory and cannot be field adjusted. The activation pressures are preset at the factory. 13. Remove existing low ambient switch (LAS)(See Fig. 10), located in the unit control box, and replace with new 0 o ambient switch (provided). 14. Remove existing fuses of the condenser fan motor to which the VFD66 control is being applied. Replace with new fuses (provided). 15. Install additional crankcase heaters on the compressors of the system to which the VFD66 control is to be applied. Wire each additional heater parallel to the existing heater, utilizing the existing ground. FIGURE 8 - JUMPER BLOCK LOCATIONS To remove a jumper, reposition the jumper so that it is connected to only one pin on the jumper block. Keep the jumper because it may be 16. Secure wiring in the unit control box in a neat workman like manner using wire ties. 17. Replace terminal access cover on VFD66 control. 18. Replace lid on VFD66 enclosure. 4 Unitary Products Group

19. Close unit control box by replacing unit access panel and restore power to the unit. 20. Verify proper unit operation. A call for cooling closes the (M5) contactor powering the VFD66 control. As the discharge pressure rises above 210 PSI. during startup, the VFD66 control will increase the speed of the condenser fan accordingly. The unit s scroll compressor produces a rapid rise in discharge pressure upon startup and this, depending on the ambient temperature, will result in full speed operation of the condenser fan. After the discharge pressure has stabilized, the speed of the condenser fan may decrease especially during times when the ambient temperature is below 80 0 F. If the discharge pressure has stabilized and an additional compressor is energized, the speed of the condenser fan may increase, compensating for the rise in discharge pressure. As the discharge pressure begins to fall below the 270 PSI. setpoint, the drive will reduce the speed of the condenser fan. As the ambient temperature drops below 40 0 F the condenser fan will slow to the minimum speed. The pressure controlled condenser fan will disengage when the discharge pressure drops below 180 PSIG as the ambient temperature falls. The system discharge pressure will increase when the condenser fan is disengaged causing the VFD66 control to increase the condenser fan speed. 21. Contact your local branch or distributor for questions regarding installation. FIGURE 10 - LAS-LOW AMBIENT SWITCH WIRING LOCATIONS * Single control board (RB1) applies to 25-Ton unit only. **Dual control board (RB1 & 2) apply to 30, 40 & 50 ton units. Unitary Products Group 5

FIGURE 11-25, 30, 40 & 50 TON LOW AMBIENT KIT DIAGRAM 6 Unitary Products Group

Unitary Products Group 7

Subject to change without notice. Printed in U.S.A. Copyright 2004 by Unitary Products Group. All rights reserved. 102694-UAI-A-1004 Supersedes: 11592-UAI-B-1102/035-18560-001-B-1102 Unitary 5005 Norman Products York OK Group Drive 73069