DEWS SERIES 25W-30W WIDE INPUT RANGE

Similar documents
KQWS SERIES 40W WIDE INPUT RANGE

Voltage Set-point Accuracy +/-2% max. Input Voltage Range 2:1 or 4:1 Input Range. Short Circuit Restart Automatic Efficiency 88% typ.

KHWS SERIES 40W-80W WIDE INPUT RANGE

LW SERIES 5W WIDE INPUT RANGE

PU SERIES 1W UNREGULATED

E-Star Power Development Co., Ltd. (E-STAR) Phone : Fax :

PG02S Series 2W DC/DC CONVERTER, SIP-Package

2W, Low Cost DIP, Dual Output DC/DC Converters

Unit/Comments. %; Equal Output Loads %; Equal Output Loads Full Load

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

RCD15W Series PART NUMBER STRUCTURE

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

(typ.) (Range) ±18 330# 89 MPW MPW

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

DH50 SERIES. DATASHEET Rev. A

UL Certified RP30-FW

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

SH01S/D Series 1W DC/DC CONVERTER, SMD-Package

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

DCMCW60 SERIES FEATURES

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

RUZ- _/_ Protection (3) Isolation Option (4)

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

(typ.) (Range) Load

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

MPP10-48 S 05 W A - P T Series Name Input Output Output Input Pin Connection Remote On/Off Trim Voltage Quantity Voltage Range Option Options Option

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

C B. Operating up to 5000m altitude 5 year product warranty Models

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)

4:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 87% Ultraminiature Open Frame SMD No Minimum Load Required

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Features. Unregulated Converters. 2 Watt SIP7 Single and Dual Output RKZE. RKZE- _/_ Protection (4) Isolation Option (3) Single or Dual

Series AM1D-Z 1 Watt DC-DC Converter

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 91% Six-Sided Continuous Shield Available as Power Module (RPM60-G)

APPLICATIONS: AVAILABLE OPTIONS

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

OSR03-24 S 05 A Series Name Input Output Output Assembly Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Series AM2D-RZ 2 Watt DC-DC Converter

Load (2) Single or Dual

MODEL SELECTION TABLE Open Frame Models. MODEL SELECTION TABLE U-Chassis Models. MODEL SELECTION TABLE Enclosed Models

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91%

Efficiency(1) Max. Capacitive. Package(3) CTRL Logic(2) Single

Features. Isolation PFM. Block Diagram

Package (3) CTRL Logic (2)

Note1: Efficiency is tested by nominal Vin, full load and at 25 C. Package (3) CTRL Logic (2)

Input Voltage Range ±10% Output Voltage Accuracy Line Voltage Regulation RSS, RSS8, RSD, RSD10 1.2%/1% of Vin typ.

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

RP40- _FR/ Package (4) CTRL Logic (3)

Volant NEA/NEF010 Series

S24SP series 40W Single Output DC/DC Converter

Packaging (1) Package

DC/DC Converter URF48_QB-200W(F/H)R3 Series

American Power Design, Inc.

DC/DC Converter URF48_QB-75W(F/H)R3 Series

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

3-Phase Military AC-DC Power Supply 3-Phase, VrmsL-L

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

25 to 30 Watt XW Single Series DC/DC Converters

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S

FEATURES. Input Voltage (VDC) 3.3

MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters

Conducted and radiated emissions (Note 4) EN55011, EN55022, Class A and FCC part 18 Immunity (Note 5)

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

LSS-T/10-W12. Adjustable Output 10 Amp SIP-mount DC/DC Converter. PRODUCT OVERVIEW FEATURES

Series AM1P-Z 1 Watt DC-DC Converter

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Sales: Technical: Fax:

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Series AM2F-Z 2 Watt DC-DC Converter

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

S24SP15004 series 60W Single Output DC/DC Converter

ISOLATED DC-DC Converter EC2SB SERIES APPLICATION NOTE

Industrial Power Supplies

Series AM5T-Z 5 Watt DC-DC Converter

Features. Non Isolated Power Module ROF-78E ROF-78E - SMD-R. DC/DC Converter

Transcription:

DEWS SERIES 25W-30W WIDE INPUT RANGE FEATURES 25-30 WATTS OUTPUT POWER ULTRA COMPACT SIZE:1.0 x1.0 x0.52 INDUSTRY STANDARD PACKAGE 9V-18V,18V-36V,36V-75V WIDE INPUT RANGE 100% BURNED IN HIGH EFFICIENCY UL 94V-0 PACKAGE MATERIAL CUSTOM SOLUTIONS AVAILABLE 3 YEARS WARRANTY OUTPUT SPECIFICATIONS INPUT SPECIFICATIONS Voltage Set-point Accuracy +/-2% max. Input Voltage Range 2:1 Temperature Coefficient +/-0.05%/ C Input Filter Pi Network Ripple& Noise(20MHz BW) 1 150mVp-p max. Remote ON/OFF Control Table 1 Line Regulation 2 +/-0.5% max. Protection Fuse Recommended Load Regulation 3 +/-0.5% max. GENERAL SPECIFICATIONS Minimum load 10% of Full Load Efficiency 85% typ. Short Circuit Protection Continuous Isolation Voltage 4 1500 VDC min. Short Circuit Restart Automatic Isolation Resistance 10 9 ohms min. External Trim Adj. Range Vout:5V +/-10% Isolation Capacitance 2200pF max. Vout:12V,15V -20%~+10% Switching Frequency 400KHz typ. Over Load Protection 150% typ. Weight 20g typ. Transient Response 5 500uS max. Case Material Six-Side Shielded Case ENVIRONMENTAL SPECIFICATIONS Case Size 25.4mm*25.4mm*13.2mm Operating Temperature -40 C to+100 C(with derating) Potting Material Epoxy(UL94V-0) Case Temperature +110 C max. MTBF 6 >300,000 Hours Storage Temperature Humidity -55 C to +125 C 95% max. Cooling Free-Air Convection ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD, AND 25 C UNLESS OTHERWISE NOTED. 1 Measured with 1uF ceramic capacitor connect to the output pins. 2 High Line to Low Line. 3 Load Regulation is for output load current change from 10% to 100%. 4 For 10 seconds. 5 25% Step Load Change. 6 MIL-HDBK-217F @Ta=25 C, Ground Benign. DANUBE http://www.danube.com.tw 1

SELECTION GUIDE 2:1 25W - 30W OUTPUT MODEL NUMBER INPUT VOLTAGE (VDC) OUTPUT VOLTAGE (VDC) OUTPUT CURRENT (ma) INPUT 7 CURRENT FULL LOAD (ma) NO LOAD EFF (%) 8 ISOLATION (VDC) CAPACITOR LOAD MAX. DEWS-1205 9-18 5 5000 2422 150 86 1500 1000uF DEWS-1212 9-18 12 2084 2423 130 86 1500 220uF DEWS-1215 9-18 15 1667 2395 120 87 1500 100uF DEWS-2405 18-36 5 5000 1197 100 87 1500 1000uF DEWS-2412 18-36 12 2500 1420 55 88 1500 220uF DEWS-2415 18-36 15 2000 1420 55 88 1500 100uF DEWS-4805 36-75 5 5000 599 70 87 1500 1000uF DEWS-4812 36-75 12 2500 710 55 88 1500 220uF DEWS-4815 36-75 15 2000 710 55 88 1500 100uF Note: Other input to output voltages may be available. Please contact factory. 7 NOMINAL INPUT VOLTAGE. 8 NOMINAL INPUT VOLTAGE, FULL LOAD. DANUBE http://www.danube.com.tw 2

MECHANICAL DIMENSIONS & RECOMMENDED FOOTPRINT DETAILS PIN SINGLE 1 +Vin 2 -Vin 3 Remote On/Off 4 -Vout 5 Trim 6 +Vout NOTE: Pin Size is Tolerance 1.0Φ ±0.10mm All dimensions are in millimeters [inches] Tolerance.X or.xx= ±0.8mm Table1 (Remote On/Off Control) Remote On/Off Control Control Input PIN3 Control Common PIN2 Control Voltage Converter Shutdown Idle Current 10mA ON OFF >+2.5VDC or Open Circuit Logic Compatibility <+0.5VDC or Jumper to PIN2 CMOS or Open Collector TTL DANUBE http://www.danube.com.tw 3

SIMPLIFIED SCHEMATIC TYPICAL APPLICATIONS FIXED VOLTAGE OUTPUT TRIM CONNECTIONS USING A TRIMPOT FIXED-VALUE TRIM DOWN RESISTOR FIXED-VALUE TRIM UP RESISTOR DANUBE http://www.danube.com.tw 4

TYPICAL PERFORMANCE CURVES Specifications typical at Ta=25 O C, nominal input voltage, rated output current unless otherwise specified. OUTPUT LOAD VS EFFICIENCY 100.0 EFFICIENCY(%) 80.0 60.0 40.0 20.0 0.0 0 20 40 60 80 100 % OF RATED LOAD(%) DERATING CURVE 125 TEMPERATURE DERATING OUTPUT POWER(%) 100 75 50 25 0 (Derating) SAFE OPERATING AREA -40 0 50 100 TA(degree C) INPUT FUSE SELECTION GUIDE 9-18V INPUT VOLTAGE(VDC) 18-36V INPUT VOLTAGE(VDC) 36-75V INPUT VOLTAGE(VDC) 10000 ma Slow-Blow Type 5000 ma Slow-Blow Type 2500 ma Slow-Blow Type INPUT OUTPUT Fuse +Vin +Vout DC-DC CONVERTER -Vi n -Vout Note: Certain applications may require the installation of external fuse in front of the input. DANUBE http://www.danube.com.tw 5

DEWS SERIES APPLICATION NOTES: EXTERNAL CAPACITANCE REQUIREMENTS: External output capacitance is not required for operation; however it is recommended that 10uF MLCC and 0.1uF ceramic capacitance be selected for reduced system noise.. Negative Outputs: A negative output voltage may be obtained by connecting the +OUT to circuit ground and connecting OUT as the negative output. Remote ON/OFF: The remote ON/OFF pin may be left floating if this function is not use. It is recommended to drive this pin with an open collector arrangement or a relay contact. When the ON/OFF pin is pulled low with respect to the Vin, the converter is placed in a low power drain state. Output TRIM: The TRIM pin may be used to adjust the output +/-10% from the nominal setting.this function allows adjustment for voltage drops in the system wiring. If the TRIM function is not required the pin may be left floating. FOR MORE INFORMATION CALL: Danube Enterprise Co., Ltd. Tel: 886-7-3755165 Fax: 886-7-3755330 E-mail: danube@ms10.hinet.net Home Page http://www.danube.com.tw DANUBE http://www.danube.com.tw 6