ST Wiring diagram. Product description. Temperature controller. Order number

Similar documents
ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

Operation Manual. Temperature Controller ST49. Revision 1.1, dated on

PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

HBLT-C1 Controller. Instruction Manual. For pump control of levels in industrial refrigeration systems

Signet Pressure Transmitter

Operating Instructions. Angle Seat Control Valve. Type 7020

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Signet Pressure Transmitter

Contact dial thermometer

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

Electronic Pressure Switch EDS 3000

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

Electronic Ballast EVG 2000-T

JConn Inv. PID Controller Instruction Manual

SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Operating instructions Flow monitors SI5000 SI / / 2007

PCT-3001 plus. Display LCD

Differential Pressure Sensor

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

RVD G2383en. Installation. - Compact station - Control cabinet (in the front, on the inner wall or on a

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

SERVICE MANUAL HOT DELI 3/4/5/7 MERCHANDISERS

Operator's manual ATSc Instrumentation en-gb

TD320 Differential Temperature Controller For HVAC

OCS-T High Resolution Digital Crane Scale

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

2-Color Display High-Precision Digital Pressure Switch

Instructions Manual Control Unit RCU205

Electronic Temperature Sensor ETS 300

Operating manual. ph / mv controller type M8832N

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

A419ABG-3C Electronic Temperature Control

Signet Temperature Transmitter

OS3050 OS3051. Controller for reverse osmosis plants. Instruction manual. Softwareversion 3.04

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Digital Pressure Gauge / Pressure Switch

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

Digital ph transmitter

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

Combined Ventilation Controller RVWS-T-224HA

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

Screw-in resistance thermometers with plug connector

Manual Kinematic Viscosity Bath Tamson TV12

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

Model Pressure range ON/OFF output Linear output

WP37 & HT37 User Manual

Operating Instruction for Electronic Pressure Switch. Model: PDD

THERMAL MANAGEMENT

DIGITAL TORQUE GAUGE MODEL BTGE-G

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

TMD90A Dual Input Digital Thermometer

MiX 2310i with IP Housing. P r o d u c t I n f o r m a t i o n G u i d e

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Paddle-wheel flow controller for On/Off control

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

Service instructions. MAGNA Series 2000

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

User Manual Reference/Professional Temperature Calibrator Jofra RTC-125/157/158/159/250/700 A/B/C Jofra PTC-125/155/350/425/660 A/B/C

MC 785-SC. Operating Manual (Wall and panel mounting) Type: MANUAL Number of pages: 32 Version: V2.3

Drive System Application

HYGROMETERS HUMIDITY MEASUREMENT YOU CAN COUNT ON.

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Self-regulating frost protection system for pipes

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

The monitor can be placed on the dashboard, on the sun visor or mounted in any convenient place in the vehicle.

User Manual Temperature Calibrator JOFRA ATC-125/140/156/157/250/320/650 A/B Copyright 2005 AMETEK DENMARK A/S ( UK)

User Manual Reference/Professional Temperature Calibrator JOFRA RTC-156/157/158/159/250/700 A/B/C JOFRA PTC-125/155/350/660 A/B/C

Reference Manual Professional Temperature Calibrator Jofra PTC-125/155/350/425/660 A/B/C

Electrical operating instructions

BRAKE TESTER DECELEROMETER

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

Digital display Pressure range ON/OFF output Linear output Model

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

CeraControl. Temperature Programmer User Handbook.

FOLLOW THE ARROWS. Alspa MV1000 Variable speed drive TEL: INSTALLATION QUICK START PROGRAMMING. FIRMWARE VERSION: 1.

Advanced Power Electronics Corp.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

DPS280 / DVS280 Series

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

SWA-24X2C PID Temperature Controller with Timer (SWA-2442C/2452C)

Warnings and Safety Tips

1.4 SCT Temperature sensor

Transcription:

ST7-31.3 Temperature controller Order number 9154.12 Wiring diagram Product description The switching exits of the thermostatic controller can be programmed as -two-point controller with alarm -three-point controller -two-stage controller -controller with ramp profile. The setpoint and all parameters of the controller are set on a three-field plastic foil keyboard. Sensor: PTC Range: -5...15 C Front size: 72mm x 36mm Panel cut-out: 68.5mm x 28.5mm Connector: screw terminal

Software.3 Adjustment options Key UP Pressing this key you can increase the parameter or parameter value or scroll the parameter list. Key DOWN Pressing this key you can decrease the parameter or parameter value or scroll the parameter list. At alarm the buzzer function can be switched off with this key. Key 4: SET While SET key is pressed, the setpoint is indicated. In addition, the SET key is used for parameters First control level: Parameter of the control setpoint If none of the keys is pressed, the display indicates the actual value of the temperature. Pressing the SET key, the setpoint shows on the display. If the setpoint is to be changed, the SET key is to be kept pressed while adjusting the setpoint with the keys UP and DOWN. Please note that the setpoint can only be changed within the set setpoint limits. Para- Function description Adjustment range Standard meter S1 Setpoint P4...P5. C Custom

Second control level (P parameters): Setting of control parameters Simultaneously pressing the UP and DOWN key for at least 4 seconds opens a parameter list containing control parameters. With the UP and DOWN keys the list can be scrolled in both directions. Pressing the SET key will give you the value of the respective parameter. Pressing also the UP or DOWN key at the same time the value can be adjusted. Return to the initial position takes place automatically, if no key is pressed for 6 seconds. Parameter Function description Adjustment range Standard P1 Setpoint 2 or P4...P5, C DeltaW -99...+999 K +1K P2 Hysteresis contact K1.1... 99.9 K 1. K P3 Hysteresis contact K3.1... 99.9 K 1. K P4* Control range limitation -99 C...P5-99 C minimum setpoint P5* Control range limitation P4...999 C 999 C maximum setpoint P6 Actual value correction -1...+1. K. K P11** Relative or -99...99K 1.K absolute employment point of -99...999 C 1. C the ramp phase P12** Ramp gradient.1...1k/min. 1.K/min. P19 Key-lock : no key-lock 1: key-lock P3 Lower alarm value -99...999 C/K -1. K P31 Upper alarm value -99...999 C/K +1. K P32 Hysteresis alarm circuit,.1...99.9 K 1. K symmetrical Custom * standard depends on sensor type ** parameter only available with activated ramp function

Parameter description: P1: Setpoint / DeltaW for control circuit 2 Adjusting the setpoint of control circuit 2. If A5=1, the setpoints for control circuit 1 and 2 are linked with one another via switching difference DeltaW, which can be adjusted with P1. (operation with DeltaW) The following applies: setpoint thermostat 2 = setpoint control circuit 1 + delta W2. This difference can take positive or negative values. Thus, a leading or following contact can be realised. P2: Hysteresis contact K1 P3: Hysteresis contact K3 The hysteresis can be set symmetrically or one-sided at the setpoint (see A4, A41). At one-sided, the hysteresis works downward with heating contact and upward with cooling contact. At symmetrical hysteresis, half of the hysteresis value is effective below and half of the value above the switching point (see fig. 1 and 2). Fig. 1: Heating controller, one-sided hysteresis hysteresis Fig. 2: Cooling controller, symmetrical P4: Control range limitation minimum setpoint P5: Control range limitation maximum setpoint The adjustment range of the setpoint can be limited in both directions. This is to prevent the end user of a unit from inadmissible or dangerous setpoints. P6: Actual value correction This parameter allows the correction of actual value deviations caused for example by sensor tolerances or extremely long sensor lines. The regulation measure value is increased or decreased by the here adjusted value. P11: Employment point of the ramp phase Before reaching the point of ramp employment the controller works at full heating/cooling power. After reaching the point of ramp employment regulation to reach the setpoint is effected by help of a ramp profile. The ramp is ascending at heating function with employment points below the setpoint. At cooling function it is falling with employment points above the setpoint. After the setpoint is reached, the ramp function becomes inactive, unless the temperature exceeds the point of ramp employment again in either direction, due to external influences (see fig. 3+4). Changes of ramp parameters are not considered once the ramp has started, but become effective only thereafter. In the case of activated ramp function, there are two employment points for the ramp possible (see parameter A6):

Fig. 3: relative values Fig. 4: absolute values The main setpoint S1 and the point of ramp employment are linked as difference with one another. This difference can take positive or negative values, i.e. starting point for the ramp can be above the setpoint at cooling function or below the setpoint at heating function, and automatically runs along with adjustments of the desired value. Main setpoint S1 and ramp employment point are independent from each other P12: Ramp gradient The ramp gradient sets the degree applied to change the (internal) setpoint in a ramp phase. P19: Key-lock The key-lock allows blocking of the control keys. In locked condition parameter adjustments with keys is not possible. At the attempt to adjust the parameters despite key-lock the message "===" appears in the display. P3: Lower alarm value P31: Upper alarm value The exit alarm is a boundary alarm or a range alarm with symmetrical hysteresis (see P32). Both at the boundary alarm and the range alarm, limit values can be relative, i.e. going along with the setpoint, or absolute, i.e. independent of the setpoint. The operation mode is set with parameter A3. If, in case of boundary alarm and only one switching point is required the not used second switching point should be adjusted to a value above or below the operating range of the controller. Boundary alarm function (see fig. 5): The alarm contact is closed if the process temperature is above the upper or below the lower boundary value. Range alarm function (see fig. 6): Opposite switching behaviour to the boundary value alarm. The alarm contact is closed if the actual value remains between the boundary values. Fig. 5: Boundary alarm, rel. boundaries Fig 6: Range alarm, abs. boundaries P32: Hysteresis alarm circuit Hysteresis is set symmetrical at the adjusted limit value, i.e. half of the hysteresis value is effective below and half of the value above the switching point

Third control level, (A parameters): Setting of control parameters Access to the third control level is granted when selecting the last P-parameter on the second control level. Continue to press the UP key for approximately 1 seconds until PA appears. Continue to press the UP key and additionally press the DOWN key for about 4 seconds and the first A-parameter of the third control level is indicated. With the keys UP and DOWN you can scroll the list in both directions. Pressing the SET key will give you the value of the respective parameter. By pressing the UP or DOWN key at the same time the value can be adjusted. Return to the initial position takes place automatically, if no key is pressed for 6 seconds, or by simultaneously pressing the UP and DOWN key for approx. 4 seconds. Parameter Function description Adjustment range Standard A1 Switch mode contact K1 : heating contact 1: cooling contact A2 Switch mode contact K3 : heating contact 1: cooling contact 1 A3 Function of contact K1 at : relay off sensor error 1: relay on A4 Function of contact K3 at : relay off sensor error 1: relay on A5 Selection setpoint 2 or : operation with setpoint 2 DeltaW 1: operation with DeltaW 1 A6 Control characteristics : no ramp function 2: relative ramp function 3: absolute ramp function A8 Display mode : integrals, without leading zero (all parameter indications 1: with decimals without leading zero 1 are presented in.1 K) A9 Weighing factor.5... 1.5 1. A1* Indication value for lower -99...999. value linear analogue input A11* Indication value for upper -99...999 1 value linear analogue input A19 Parameter lock : no lock 1: A-parameter locked 2: A- and P-parameter locked A2 Key acknowledgement : no 1: yes 1 A3 Function alarm exit : Boundary alarm, relative 1: Boundary alarm, absolute 2: Range alarm, relative 3: Range alarm, absolute A31 Special function at boundary or range alarm : no special function 1: flashing display 2: buzzer 3: flashing display and buzzer 4: like 3, buzzer can be cancelled 5: like 4, cancelled buzzer restarts after 1 min. 6: like 4, cancelled buzzer restarts after 3 min. Custom

Parameter Function description Adjustment range Standard A32 Alarm delay after...6 min. min. Power-on A4 Hysteresis mode : symmetrically contact K1 1: one-sided A41 Hysteresis mode : symmetrically contact K3 1: one-sided A5 Minimum action time...4 sec.. sec. contact K1 On A51 Minimum action time...4 sec.. sec. contact K1 Off A52 Minimum action time...4 sec.. sec. contact K3 On A53 Minimum action time...4 sec.. sec. contact K3 Off A54 Delay after Power-on...4 sec.. sec. A55 Mutual delay of contacts...4 sec.. sec. K1 and K3 A6 Sensor type 1: Thermo element type J 2: Thermo element type K 11: PT1 (2-Leiter) 12: PT1 (3-Leiter) 21: KTY81-121 (2-Leiter) 22: PT1 (2-Leiter) dependent on hardware Custom 31: 2-1 V or 4-2 ma 32: -1 V or -2 ma A7 Zeitkonstante Softwarefilter :. sec. 1:.8 sec. 2: 2.4 sec. 3: 6. sec. 3 4: 16. sec. 5: 38.6 sec. 6: 96. sec. A8** Temperature scale : Fahrenheit 1: Celsius 1 * parameter only available if there is a voltage/current input ** not available with voltage or current input

Parameter description: The following values can change the equipment characteristics and are therefore to be set with utmost care. A1: Switch mode contact K1 A2: Switch mode contact K3 The switch mode for the relays, i.e. cooling or heating function, can be programmed independently at works. Heating function means that the contact opens as soon as the setpoint is reached, thus power interruption. At cooling function the contact closes, if the actual value is above the required setpoint. (see fig. 1 + 2) A3: Function of contact K1 at sensor error A4: Function of contact K3 at sensor error At sensor error the selected relay falls back into the condition pre-set here. If there is a data-loss in parameter memory (display indicates EP ) both contacts K1 and K3 are switched off. A5: Selection setpoint 2 or DeltaW This parameter determines whether the setpoints for thermostat 1 and 2 independently adjustable (A5=) or whether they are tied with one another via a switching offset DeltaW (A5=1). This parameter applies only to contact K3 (see parameter P1). A6: Control characteristic With this parameter the ramp function can be activated with either relative or absolute employment point. A8: Display mode The value can be indicated in integrals or with decimals and if there is a leading zero. In general, all parameter indications are presented with decimals. A9: Weighing factor With this parameter the actual value can be submitted to weighing. The measured value is multiplied by it and both indicated in the display and applied for regulation. A1: Indication value for lower value linear analogue input A11: Indication value for upper value linear analogue input Only relevant, if the controller is programmed for a voltage input ( 1V linear) or a current input (4 2mA linear). These parameters allow scaling of the linear analogue input. The value to be indicated for the lower and upper entrance value then defines the range the controller will indicate. For input range 4 2mA the display will show sensor error if the input signal drops below 4mA. A19: Parameter lock This parameter enables locking of each parameter level. If third level is locked, only parameter A19 may be changed. A2: Activation of key acknowledgement This parameter permits to switch on/off the key confirmation by internal buzzer. A3: Function alarm exit The alarm exit evaluates an upper and a lower limit value (see parameters P3 and P31), whereas a selection is possible as to whether the alarm is active if the temperature lies within these two limits (range alarm), or whether the alarm is released if the temperature lies beyond them (boundary alarm). In the case of sensor error, the alarm is activated independently of this adjustment.

A31: Special function at boundary or range alarm Here can be selected whether, in the case of an alarm, the indication to flash and/or the buzzer is to start. Sensor alarm (display F1L or F1H) is indicated independently thereof by flashing display and the buzzer. A32: Special function at boundary or range alarm This parameter allows an alarm delay after switching-on the mains voltage A4: Hysteresis mode contact K1 A41: Hysteresis mode contact K3 These parameters allow selection as to whether the hysteresis values which are adjustable with P32, are set symmetrically or one-sided at the respective switching point. At symmetrical hysteresis, half of the hysteresis value is effective below and half of the value above the switching point. The one-sided hysteresis works downward with heating contact and upward with cooling contact (see fig. 1 + 2). A5: Minimum action time contact K1 On A51: Minimum action time contact K1 Off A52: Minimum action time contact K3 On A53: Minimum action time contact K3 Off These parameters permit a delay in switching on/off the relay in order to reduce the switching frequency. The adjusted time sets the entire minimum time period for a switching-on or switchingoff phase. A54: Delay after Power-on This parameter allows a switching-on delay of relays after switching-on the mains voltage. This delay corresponds with the time set here. A55: Mutual delay of contacts K1 and K3 This parameter makes a mutual switching-on delay of relays possible, depending on whichever contact is switched first. A6: Sensor type These parameter permits selection of the sensor type, if the needed hardware prerequisites are available. A7: Software filter With several measuring values, it is possible to obtain an average value. This parameter can determine by how many measured values an average value is to be formed. If a sensor with a very fast reaction to external influences is used, an average value ensures a calm signal process. A8: Temperature scale Indication can be switched between Fahrenheit and Celsius. At conversion, the parameters and setpoints maintain their numerical value and adjustment range. (Example: A controller with the desired value of C is switched to Fahrenheit. The new desired value is then interpreted as F, which corresponds to a temperature of -18 C). NOTE: Indication limits with F can be smaller than the actual measuring range!

Status messages Message Cause Error elimination _ Key-lock active Change parameter P19 or A19 F1L Sensor error, Check sensor short-circuit at sensor F1 F1H Sensor error, Check sensor open-circuit at sensor F1 F2 Wrong connection of Pt1 sensor Check connection display flashes Buzzer EP, display flashes Temperature alarm at too high or too low temperature (if activated) see A31 Temperature alarm at too high or too low temperature (if activated) see A31 Data loss at parameter memory (Contacts K1 and K3 are switched off) The buzzer function can be switched off with the DOWN-key If error cannot be eliminated by switching on/off, the controller must be repaired Error messages are saved and indicated even if the cause is eliminated. Pressing the DOWN key deletes the error message.

Technical data of ST7-31.3 Measuring input F1: Resistance thermometer PTC Measuring range: -5...15 C Measuring accuracy:.5 K, without sensor Outputs K1: Relay, change-over contact, 5A 25V (cosϕ=1) K3: Relay, change-over contact, 5A 25V (cosϕ=1) Display 3-digit LED Display, colour red 1 LED, diameter 3mm, for status display Power supply 12...24 V AC (5/6 Hz) or 16...36V DC Connectors 12-pole screw terminal, spacing 5.mm, for cable up to 2.5 mm² Ambient conditions: Storage temperature: Operating temperature: Relative humidity: -2...+7 C...+55 C max. 75% without dew Weight ca. 15g Enclosure Front IP5 Installation data Front size: Panel cut-out: Installation depth: Mounting: 72 x 36 mm 68.5 x 28.5 mm ca. 67 mm with connector by fixing strap Order No.: 2196