Modulating Control Valve PN 16 with Magnetic Actuator

Similar documents
Modulating control valves with magnetic actuators, PN 16

Modulating control valves with magnetic actuators, PN 16

Modulating control valve PN16 with magnetic actuator

MXG MXF Modulating control valves PN 16 with magnetic actuators. Building Technologies HVAC Products

Modulating control valve with magnetic actuator PN16

Modulating control valve PN16 with magnetic actuator

Control of cutting-oil emulsion for industrial grinding machines. Applications for CHW and LPHW systems, see data sheet CA1N4454E.

Modulating control valves with magnetic actuator PN 16

MXG461.. MXG461..P MXF461.. MXF461..P

Modulating control valves with magnetic actuator PN 16

MXG461.. MXG461..P MXF461.. MXF461..P

Modulating control valve PN16

2-Port Seat Valves with Flange, PN 25

3-port seat valves PN16 with flanged connection

2-Port Seat Valves with Flange, PN 25

3-Port Seat Valves with Male Thread, PN 16

2- and 3-port valves with flanged connections, PN 16

3-port seat valves, external thread, PN16

3-Port Seat Valves with Flange, PN 6

3-Port Seat Valves with Flange, PN 10

3-Port Seat Valves with Male Thread, PN 16

3-port seat valves PN16 with flanged connection

2- and 3-port valves with flanged connections, PN 16

Two-port seat valves with male thread, PN16

2-Port and 3-Port Zone Valves PN 16

3-port seat valves PN40 with flanged connection

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Three-port slipper valves PN10, female-threaded

2-port seat valves PN16 with flanged connection

3-port seat valves PN10 with flanged connection

2- and 3-port valves with flanged connections, PN 6

3-port seat valves PN6 with flanged connection

2-port seat valves PN25 with flanged connection

MVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam

VPI45..Q with pressure test points. Combi valves, PN 25

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

2-port ball valves with flanged connection, PN25

2- and 3-port valves with flanged connections, PN 25

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

2-port and 3-port valves with T-bypass PN 16

2-Port and 3-Port Zone Valves PN 16

2- and 3-port valves with flanged connections, PN 16

3-port valves vxf42..

Electromotoric actuators

2-port and 3-port terminal unit valves PN16

2- and 3-port valves with flanged connections, PN 25

Operating Instruction Modulating refrigerant valves with magnetic actuator, PS45 Hermetically sealed, for safety refrigerants

MXF461 U Series Modulating Control Valves with Magnetic Actuators

Butterfly valves PN6, PN10, PN16

Electromotoric Actuators

CONTROL EQUIPMENT STAZ-16, STBZ-16

2-Port and 3-Port Zone Valves, PN 16 / 20

Operating instruction Refrigerant Valves PS45

Combi valves PN 16 with flanged connections

Modulating refrigerant valves, PN 63

Butterfly valves PN 16

2-Port and 3-Port Zone Valves & Actuators, PN16

2-port and 3-port ball valves PN 40

Modulating control valves PN16 with magnetic actuators

2- and 3- port valves with flanged connections, PN 16

Butterfly valves PN 16

Modulating refrigerant valves, PN40

Butterfly valves, PN6, PN10, PN16

2-Port and 3-Port Zone Valves, PN16

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

Control valves with pneumatic actuators up to 350 C PN

VPI45..Q with pressure test points. Combi valves, PN 25

Cooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)

Rotary actuators for ball valves

In district heating, heating, ventilating, and air conditioning systems as DFRQWUROYDOYH

Electric actuators for small valves

Electrical Actuators

Immersion temperature sensor QAE26.9.

Electromotoric Actuators

Open/close ball valves 2-port and changeover ball valves 3-port, PN40

ACVATIX MiniCombiValves (MCV)

Acvatix Valves VVF..,VXF.., VVG41.., VXG41.., VVI41.., VXI41.. Basic Documentation - Version changes

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

2-port shutoff valves and 3-port changeover ball valves, PN 40, with internally threaded connection

Electromotoric Actuators

Differential pressure sensor

Butterfly valves PN6, PN10, PN16

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

VXF53.. VVF53.. Acvatix Valves VVF..,VXF.. Basic Documentation. CE1P4030en Building Technologies

V5049A FLANGED LINEAR VALVE PN25/40

2-position electric actuators with Ball valves VBZ ½...11/4

Mounting and Operating Instructions EB 5868/5869 EN

Differential Pressure Sensors

Electro-hydraulic actuators for valves

Differential Pressure Sensors

Condensation monitor

with electric and pneumatic actuators Control valve in 3-way-form (3-way mixing valve) DN 300 ARI-STEVI 423 Electric actuator ARI-PREMIO

VLF45... Hot Air Valves. Building Technologies Division

Electromotoric actuators

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

2-way and 3-way globe valves

Differential Pressure Sensors

Electromotoric Actuators

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

Actuators for Fire and Smoke Protection Dampers

Transcription:

4 74 Modulating Control Valve PN 6 with Magnetic Actuator for brine circuits, hot water, steam or media containing mineral oils (MK FX NP) MK FX N MK FX NP Fast positioning time (< s) High-resolution stroke and rangeability Operating voltage AC 4 V or power signal DC 0 0 V Phs (phase cut) Selectable electrical interface DC 0 0 V, DC 4 0 ma or DC 0 0 V Phs Fail-safe feature: control path closed when de-energised Low friction, robust, no maintenance required Use The control valves are mixing or throughport valves with the magnetic actuator ready fitted. The short positioning time, high resolution and high rangeability make these valves ideal for modulating control of chilled water, low-temperature hot water, hightemperature hot water, hot water and steam systems or media containing mineral oils in closed circuits of heating, ventilating and air conditioning systems as well as industry related applications. CAN474en 08-0-4 Building Technologies HVAC Products

Type summary Type reference ) DN k VS Χp max Χp S S NA Pmed I N Wire cross-section [mm ] 4-wire connection 4.0.5 4.0 [m /h] [kpa] [kpa] [VA] [W] [A] Max. cable length L [m] MK5FX06N 0.6 MK5FX5N 5.5 MK5FXN.0 MK0FXN 0 5.0 MK5FXN 5 8.0 MKFXN MK40FXN 40 0 500 500 00 00 0 5.5 40 65 0 6 6 4 0 50 80 MK50FXN 50 0 40 0 6. 0 0 50 ) Version for media containing mineral oils with type suffix P, e.g. MK50FXNP Χp max = max. permissible differential pressure across the valve s control path, valid for the entire actuating range of the motorised valve Χp S = max. permissible differential pressure (close off pressure) at which the motorised valve will close securely against the pressure (used as throughport valve) S NA = nominal apparent power for selecting the transformer P med = typical power consumption I N = required slow fuse k VS = nominal flow rate of cold water (5 to 0 C) through the fully opened valve (H 00) at a differential pressure of 00 kpa ( bar) L = max. cable length; with 4-wire connections, the max. permissible length of the separate.5 mm copper positioning signal cable is 00 m. Accessories Type reference Operating voltage Positioning signal Operating range Data sheet Terminal housing ZM ZM0/A ) AC 4 V DC 0 0 V DC 4 8 V ZM/A ) AC 4 V DC 4 0 ma DC 6 ma ZM DC 0 0 V Phs DC 0 5 V Phs Description Stem heating element Z66 AC / DC 4 V, 0 W; required for medium temperatures < 0 C N459 446Z4 Blank flange set Z55/ ( = DN) with blank flange, seal, screws, spring washers and nuts ) For the ZM0/A and ZM/A types also the DC 0 0 V Phs positioning signal is possible without operating voltage. Order When ordering, please give quantity, product name and type reference. Example: valve MK5FXN terminal housing Z0/A stem heating element Z66 blank flange set Z55/5F Delivery Valve body and magnetic actuator form one assembly and cannot be separated. The terminal housing, the stem heating element and the blank flange set are delivered in a separate package /0

Technical and mechanical design Control operation Spring return facility Control Manual operation For a detailed description of operation, refer to Data Sheet CAN408E. The electronics module converts the positioning signal to a phase-cut power signal which generates a magnetic field in the coil. This causes the armature to change its position in accordance with the interacting forces (magnetic field, counterspring, hydraulics, etc.). The armature responds rapidly to any change in signal, transferring the corresponding movement directly to the valve plug, enabling fast changes in load to be corrected quickly and accurately. If the positioning signal is interrupted, or in the event of a power failure, the valve s return spring will automatically close control path. The magnetic actuator can be driven by a Siemens controller or a controller of other manufacture that deliver a DC 0...0 V, DC 4...0 ma or DC 0 0 V Phs output signal. To achieve optimum control performance, it is recommended to use a 4-wire connection. Control path ports can be opened mechanically to between 0 and approximately 90 %, by turning the handwheel clockwise (CW). The manual adjustment facility can also be used as a mechanical method of low limit control, i.e. the valve will exercise its normal control function between the manually-set position and the 00 % open position. For full-stroke automatic control, the handwheel must be set to 0 (the anticlockwise end-stop). Sizing Flow chart 474D0 V00 [m /h] DN5 k VS,5 DN5 k VS 0,6 Χpmax V00 [l/s] Χp V00 Χp V00 = differential pressure across the fully open valve and the valve s control path by a volumetric flow V00 V00 = volumetric flow through the fully open valve (H 00) Χpmax = max. permissible differential pressure across the valve s control path for the entire actuating range of the motorised valve 00 kpa = bar 0 mwc m /h = 0.78 l/s water at 0 C /0

Water with additives To determine the volumetric flow V % 00 in case of anti-freeze proportions > 0 % use the following formula: Q00 V % 00 < Ζm / h. 6 ΧT f V % 00 = Volumetric flow [m /h] Q 00 = Nominal system output [kw] T = Temperature differential between flow and return [K] = Correction factor f The correction factor f can be taken from the following table or calculated with the formula below. Table correction factor f for Antifrogen N: Temperature [ C] N [%] -40-0 0 0 40 60 80 00 00 0.60 0.6 0.6 0.65 0.67 0.68 0.69 0.7 80 0.7 0.7 0.74 0.75 0.77 0.78 0.79 0.80 60 0.79 0.80 0.8 0.8 0.84 0.85 0.86 0.86 5 0.8 0.8 0.84 0.85 0.86 0.87 0.88 0.88 44 0.87 0.88 0.88 0.89 0.90 0.90 0.90 4 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0 0.97 0.97 0.97 0.96 0.96 0.95 The data and application notes of the anti-freeze manufacturer are binding. Calculation correction factor f : kj c kgk f < 4. 8 kg θ m 000 f = Correction factor = for water c = Specific heat of anti-freeze [kj/kgk] θ = Density of anti-freeze [kg/m ] 4.8 = Specific heat of water at 0 C [kj/kgk] 000 = Density of water at 0 C [kg/m ] For valve sizing with media other than water, note that the following media properties differ from those of water. specific heat density kinematic tenacity All variables are temperature-dependent. The design temperature equals the lowest media temperature prevailing in the valve. General formula: Q V % 600 00 00 < Ζm / h c ΧT θ V % 00 = Volumetric flow [m /h] Q 00 = Nominal system output [kw] T = Temperature differential [K] between flow and return c = Specific heat [kj/kgk] ρ = Specific density [kg/m ] Note In HVAC plants, the kinematic viscosity τ [mm /s] is always below 0 mm /s so that its impact on volumetric flow is negligible 4/0

Mounting Notes Mounting Instructions are included in the packaging: No: 558 (valve) No. 554 (terminal housing ZM ) Vorsicht The valve may only be used as a mixing or throughport valve, not as a diverting valve. Observe the direction of flow!! A strainer should be fitted upstream of the valve. This increases reliability. Orientation Any 474Z0 Use as straight-through valves Only three-way valves are supplied. They may be used as straight-through valves. Port can be sealed with Z55/... which must be ordered as a separate item. The blank flange set comes complete with blank flange, seal, screws, spring washers and nuts. DN5 DN blank flange (Z55/5F Z55/F) DN40 DN50 blank flange (Z55/40 Z55/50) 474Z0 Installation Notes The actuator may not be lagged. For notes on electrical installation, see «Connection terminals» resp. «Connection diagrams» Maintenance Notes The valves and actuators are maintenance-free. The low friction and robust design make regular servicing unnecessary and ensure a long service life. The valve stem is sealed from external influences by a maintenance-free gland. Caution Caution Always disconnect power before fitting or removing the terminal housing. Under operating conditions within the limits defined by the application data, the actuator will become hot, but this does not represent a burn risk. Always maintain the minimum clearance specified, refer to «Dimensions». 5/0

Disposal The valve is considered electrical and electronic equipment for disposal in terms of the applicable European Directive and may not be disposed of as domestic garbage. Dispose of the valve through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Warranty Application-specific technical data must be observed. If specified limits are not observed, Siemens Switzerland Ltd / HVAC Products will not assume any responsibility. Technical Data Functional actuator data Power supply Extra low-voltage only (SELV, PELV) Operating voltage ) AC 4 V, + 5 % / -0 % Frequency 50 60 Hz Typical power consumption P med refer to table «Type summary» Rated apparent power S NA refer to table «Type summary» Input Positioning signal ZM0/A DC 0 0 V or DC 0 0 V Phs ZM/A DC 4 0 ma or DC 0 0 V Phs ZM DC 0 0 V Phs Current draw DC 0 0 V max. ma Impedance DC 4 0 ma x 56 kς Functional valve data PN class PN 6 to EN 6/0 Permissible operating pressure Water up to 0 C Water > 0 C Saturated steam 80 C Leakage rate Permissible media Brine Water.6 MPa (6 bar). MPa ( bar).0 MPa (0 bar) abs max. 0.05 % k vs (to DIN EN 49) approx. % k vs (depending on operating conditions) Chilled water, low-temperature hot water, hightemperature hot water, hot water, water with antifreeze; recommendation: water treatment to VDI 05 Saturated steam MK FX NP: Oil mixtures mineral oils SAE05 SAE50, heat transfer oils Medium temperature Water ) max. 80 C -0 0 C.6 MPa (6 bar) Water Saturated steam > 0 C. MPa ( bar) 80 C.0 MPa (0 bar) abs Valve characteristic (stroke, k v ) linear (to VDI / VDE 7), optimised in low opening range Stroke resolution ΧH / H00 > : 00 (H = stroke) Mode of operation modulating In de-engergised position control path closed Mounting position any

Positioning time < s Ambient temperature -5 45 C Materials Valve body spheroidal graphite cast iron EN-GJS-400-8-LT Seat / inner valve CrNi steel Valve stem seal for M N EPDM (O ring) Valve stem seal for M NP Fluoroelastomer FPM product Bellows CrNi steel Electrical connection Cable entry x PG (ZM0/A, ZM, ZM/A) Min. cross-sectional area.5 mm Connection terminals screw terminals for max. x 4 mm copper wires Dimensions / weight Dimensions refer to «Dimensions» Weight refer to table in «Dimensions» ) ) No operating voltage is required for the DC 0 0 V Phs power positioning signal. For medium temperatures < 0 C, the Z66 stem heating element is required. Norms and standards Degree of protection IP 54 to IEC 6059 Conforming to CE requirements Permissible operating pressure PED 97//EC Pressure accessories as per article, section..4 Fluid group without CE-marking as per article, section (sound engineering practice) General environmental conditions Operation EN 607-- Transport EN 607-- Storage EN 607-- Climatic conditions Class K5 Class K Class K Temperature 5...+45 C 5...+70 C 5...+45 C Humidity 5...95 % r.h. 5...95 % r.h. 5...95 % r.h. Mechanical conditions EN 607--6 Class 6M Connection terminals Warning If a ZM /A terminal housing is used with DC 0...0 V Phs (phase cut), AC 4 V must not be connected! ZM0/A (DC 0...0 V or DC 0...0 V Phs) ZM (DC 0...0 V Phs) 4 5 6 ~ ~ + Supply AC 4 V Positioning signal DC 0...0 V 4 5 6 + DC 0...0 V Phs (phase cut) 4 5 6 DC 0...0 V Phs ZM/A (DC 4...0 ma or DC 0...0 V Phs) 4 5 6 ~ ~ + Supply AC 4 V Positioning signal DC 4...0 ma 4 5 6 + DC 0...0 V Phs (phase cut) twisted pairs 47Z0en 7/0

Connection diagrams Refer to data sheet N459 for the ZM terminal housings. Application examples Hydraulic circuits Caution The examples shown below are basic diagrams with no installation-specific details. The valve may only be used as a mixing or throughport valve, not as a diverting valve. Observe the direction of flow! 0 x DN [min. 0.5 m] 474Z0 A B C D E A Mixing circuit B Mixing circuit with bypass (underfloor heating system) C Injection circuit D Diverting circuit E Injection circuit with throughport valve 8/0

Dimensions Dimensions in mm H min. E F 474M0 H min. H B L D K D L D L Type reference MK5FX06N DN B D D K L L L H H min. E F Weight [kg] MK5FX5N 5 4 95 65 0 65 65 8 7 MK5FXN 4x4 84 80 MK0FXN 0 05 75 50 75 75 8 00 9 MK5FXN 5 6 5 85 60 80 80 89 0 MKFXN 40 00 80 90 90 5 6 MK40FXN 40 8 50 4x8 0 00 00 00 4 94 00 8 MK50FXN 50 0 65 5 0 5 05 4 50 4 Remarks: Flange dimensions to ISO 7005- / DIN 5, PN 6 Weight including packaging 9/0

Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Theilerstrasse a 600 Zug Switzerland Tel. +4 58-74 4 4 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 005 Technical specifications and availability subject to change without notice. 0/0