Globe Valve BOA-Compact PN 6/16 DN 15-200 Soft-seated Flanged Type Series Booklet
Legal information/copyright Type Series Booklet BOA-Compact KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without KSB s express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft Frankenthal 2011
Globe Valves BOA-Compact Flanges to DIN EN 1092-2 Type 21 Position indicator outside the insulating material Locking device, travel stop, position indicator, throttling plug and insulating cap with anti-condensation feature as standard Suitable for full insulation in acc. with German energysaving regulations Non-rotating stem with protected, external thread Maintenance-free stem seal with EPDM profile ring Compact throttling plug with EPDM coating as soft main and back seat Exterior coating: blue RAL 5002 The valves satisfy the safety requirements of Annex I of the European Pressure Equipment Directive 97/23/EC (PED) for fluids in Group 2. Type-tested to the specifications of Germanischer Lloyd Variants Lead-sealable cap (prevents unauthorised actuation) as assembly set Electric actuators Body materials Main applications Hot-water heating systems Air-conditioning systems Heat recovery systems Fluids handled Water Water/glycol mixtures Not suitable for fluids containing mineral oils, steam or fluids liable to attack EPDM and cast iron. Other fluids on request. Operating data Operating properties Characteristic Value Nominal pressure PN 6/16 Nominal size DN 15-200 Max. permissible pressure 16 bar Max. permissible temperature 120 C Overview of available materials Material Material number Temperature limit EN-GJL-250 JL 1040 up to 120 C Product benefits Zero leakage and zero maintenance for life due to lubricated-for-life EPDM profile ring and single-piece body. Minimal pressure drop due to hydraulically favourable flow passage. One model for shut-off and throttling: fully EPDM-coated throttling plug with linear characteristic. Easy insulation thanks to simple body design and anticondensation feature (insulating cap). Fully equipped at no extra price: internal travel stop, position indicator and locking device included. Cost-effective transport and handling due to short face-toface length and low weight. Design details Desig n Straight-way globe valve with slanted seat Slanted seat design Short face-to-face length to DIN EN 558/14 Single-piece pressure-retaining body Non-rising handwheel BOA-Compact 3
Related documents For hydraulic balancing we recommend our BOA- Control IMS control valve with integrated sensor for flow rate and temperature measurement, and our BOATRONIC M measuring computer. For water supply systems and cooling circuits as well as drinking water applications we recommend our maintenance-free BOA-Compact EKB globe valves. For fluids containing mineral oils, temperatures exceeding 120 C and low-pressure steam systems we recommend our maintenance-free BOA-H globe valves. The valves are also available as automated variants with electric actuators (continuous-action 24 V AC, 230 V AC) and 3-point (Open/Stop/Closed) actuators (24 V AC, 230 V AC) as BOA-CVE globe valves. Other applicable documentation Document Reference No. Valve characteristics 7112.4 Operating manual 0570.8 Document Reference No. Installation instructions "Accessories set for 0570.811 capped valves" BOA-Compact EKB type series booklet 7112.11 BOA-Control IMS type series booklet 7128.1 BOA-CVE globe valves type series booklet 7520.1 BOA-H type series booklet 7150.1 On all enquiries/orders please specify 1. Type 2. Nominal pressure 3. Nominal size 4. Variants 5. Number of type series booklet Pressure/temperature ratings Test and operating pressures Nominal Nominal size Body pressure test Seat tightness test Permissible operating pressures 1) pressure with water P10, P11 2) P12 3) -10 to +120 C PN DN [bar] [bar] [bar] 6 15-200 9 6,6 6 16 15-200 24 17,6 16 1) Static load 2) DIN EN 12266-1 (P10, P11) 3) Test procedure to DIN EN 12266-1 (P12, leakage rate A) 4 BOA-Compact
Materials *) DN 15-150 DN 200 Overview of available materials Part No. Description Material Note 100 Body EN-GJL-250 (JL1040) 200 Stem Stainless steel, min. 13 % chrome (Cr) 350 Valve disc Grey cast iron/epdm 410 Profile joint Elastomer EPDM 506 Retaining ring Plastic DN 20-150 Galvanised steel DN 200 580.1 Cap Plastic, glass-fibre reinforced, impact-resistant 689 Insulating cap Plastic 903 Travel stop Galvanised steel 904 Locking device Galvanised steel 916 Plug Plastic 925 Stem nut Galvanised steel 961 Handwheel Aluminium, die-cast Plastic, glass-fibre reinforced, impact-resistant DN 15-25 Grey cast iron (JL1030) DN 200 BOA-Compact 5
Dimensions 1) 2) 3) 4) 1) Locking device 2) Insulating boundary in acc. with German energy-saving regulations 3) Lead-sealable cap (prevents unauthorised actuation) as assembly set 4) With electric actuator (BOA-CVE globe valves) Dimensions in mm Flange Capped valve PN DN l h 1 d 1 d 2 a 1 a 2 a 3 D b k n d 6 [kg] d 3 d 4 h 3 6 15 115 156 80 35 105 46 50 80 12 55 4 11 1,7 166 130 195 20 120 156 80 35 105 46 55 90 14 65 4 11 2,1 166 130 195 25 125 156 80 35 105 46 65 100 14 75 4 11 2,3 166 130 195 32 130 179 100 35 122 46 75 120 16 90 4 14 3,8 166 130 210 40 140 179 100 35 122 46 85 130 16 100 4 14 4,3 166 130 210 50 150 189 100 43 131 46 95 140 16 110 4 14 4,9 166 130 220 65 170 252 125 47 174 66 112,5 160 16 130 4 14 7,7 166 130 260 80 180 252 160 52 185 76 135 190 18 150 4 19 10,9 210 170 310 100 190 298 160 63 215 73 155 210 18 170 4 19 14,7 210 170 350 125 200 373 200 85 270 115 170 240 20 200 8 19 21,0 270 220 435 150 210 386 250 85 282 113 182,5 265 20 225 8 19 26,5 390 340 460 200 230 693 315 136 434 174 220 340 30 280 8 19 71,0 390 340 600 16 15 115 156 80 35 105 46 57,5 95 14 65 4 14 2,3 166 130 195 20 120 156 80 35 105 46 62,5 105 16 75 4 14 2,7 166 130 195 25 125 156 80 35 105 46 72,5 115 14 85 4 14 3,0 166 130 195 32 130 179 100 35 122 46 85 140 18 100 4 19 4,8 166 130 210 40 140 179 100 35 122 46 95 150 18 110 4 19 5,5 166 130 210 50 150 189 100 43 131 46 107,5 165 20 125 4 19 6,9 166 130 220 65 170 252 125 47 174 66 125 185 20 145 4 19 10,0 166 130 260 80 180 252 160 52 185 76 140 200 22 160 8 19 12,5 210 170 310 100 190 298 160 63 215 73 160 220 24 180 8 19 17,1 210 170 350 6 BOA-Compact
Flange Capped valve PN DN l h 1 d 1 d 2 a 1 a 2 a 3 D b k n d 6 [kg] d 3 d 4 h 3 125 200 373 200 85 270 115 175 250 26 210 8 19 26,5 270 220 435 150 210 386 250 85 282 113 192,5 285 26 240 8 23 31,0 390 340 460 200 230 693 315 136 434 174 220 340 30 295 12 23 71,0 390 340 600 Matin g dimensi ons - Sta ndards Face-to-face lengths: DIN EN 558 FTF-14, ISO 5752/14 Flanges: DIN EN 1092-2, flange type 21 Raised face: DIN EN 1092-2, type B Installation instructions Flow through the shut-off globe valves should be in the direction of the embossed arrow on the valve body. An alternating direction of flow is permissible, however. EN 1515-4 "Selection of bolting for equipment subject to the Pressure Equipment Directive 97/23/EC" and any plant regulations governing the application in question must be observed when selecting connecting elements between the valve flange and the pipe flange. BOA-Compact 7
Chemical resistance chart The information provided in this chemical resistance chart is based on experience, the Dechema lists as well as manufacturer information. Corrosion resistance is largely dependent on the operating conditions, temperatures and concentrations. Hydroabrasive wear in fluids containing solids is not covered in this list. All information provided herein, therefore, only serves as an orientation. Warranty claims may not be asserted on the basis of this list! Chemical resistance chart for water 4) Fluid handled Max. content Max. temp. Bathing water (fresh water) Bathing water (seawater) Brackish water Service water Chlorinated water 0,6 mg/kg Deionised water (demineralised water) Distilled water Heating water Condensate Oil-free cooling water Oil-containing cooling water Seawater Ozonised water 0,5 mg/kg Pure water Raw water Waste water 5) Partly desalinated water Thermal water Drinking water Fully desalinated water Chemical resistance chart for other fluids Fluid handled Max. content Max. temp. Landfill gas Oil-containing compressed air Aqueous glycerine Carbon dioxide (gas) Carbon dioxide (aqueous solution) Oxygen O₂ Key to the symbols Symbol Description The fluid handled normally does not attack the materials. Valve can be used if 4) and 5) are observed. The fluid handled is aggressive to the materials. Valve cannot be used. The material or valve can only be used under certain operating conditions. Please enquire accordingly stating the operating conditions such as concentration, temperature, ph value and composition of the fluid handled. Chemical resistance chart for oils (aromatic content 5 mg/kg) Fluid handled Max. content Max. temp. Vegetable oils Mineral oils Synthetic oils Petroleum Oil-water emulsion Kerosene Chemical resistance chart for refrigerants Fluid handled Max. content Max. temp. Ammonium hydroxide 25 % 25 C Glycol (ethylene glycol) Water-glycol mixture 50 % 90 C Inorganic cooling brine, ph 7,5 inhibited Chemical resistance chart for cleaning agents Fluid handled Max. content Max. temp. Lye for bottle rinsers (e.g. P3) Lye for metal cleaning 4) General criteria for water to be handled by valves made of non-alloyed materials: ph value 6,5-12; chlorides (Cl-) < 150 mg/kg; chlorine (Cl) < 0,6 mg/kg. Other factors to be considered: hardness, carbon dioxide content (CO₂), oxygen (O₂) and dissolved substances. Contact KSB if limits are exceeded! 5) Without larger solids or stringy material 8 BOA-Compact
KSB Aktiengesellschaft Johann-Klein-Straße 9 67227 Frankenthal (Germany) Tel. +49 6233 86-0 Fax +49 6233 86-3476 E-Mail: valves@ksb.com www.ksb.com 7112.1/20-10 16.05.2011