Operating Instructions

Similar documents
Instructions. for Installation, Operation and Maintenance of ABO Butterfly Valves, Series 600 and 900

Safety Instructions. Series 3 E. for Installation, Operation and Maintenance of ABO Buteerfly Valves

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Instructions for installation, operation and maintenance of: GATE VALVE

Danfoss Butterfly Valve

DOUBLE-ECCENTRIC BUTTERFLY VALVES TYPE L32.7

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Installation, Operation And Maintenance Manual. Manual. For the 400 Series. ABZolute Seal. High Performance Butterfly Valve "Double Offset"

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Installation, Operation and Maintenance Manual for the HE Series

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

ABsOlute flow control. SERIES 3E // DN (6-16 ) // Oil & Gas // Power Generation // Petrochemistry

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

series BUTTERFLY VALVE DOUBLE ECCENTRIC FLANGED FAF 3800 PRODUCTION STANDARDS DN100 DN2000 PN Design EN 593 EN ISO Flanged

Butterfly valves for high temperature series GD(H) - LDK

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

KEYSTONE. Hygienic butterfly valves model F250 & F251 Installation & Maintenance Instructions. 1 Contents 1 Contents 1

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

Installation and operating manual

R o L. BUTTERFLY VALVE of carbon steel with welded ends 313 -series BLUE LINE. Description

DOUBLE-ECCENTRIC BUTTERFLY VALVES TYPE L32.7

Operating Instructions: Hand-operated, PTFE-lined butterfly valves, Series 22/23

Series 250 Pneumatic Control Valves Type and

Operating Instructions

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

TRIPLE-ECCENTRIC BUTTERFLY VALVES TYPE L32.8

BUTTERFLY VALVE - WAFER FAF 3500

Double Offset High Performance Butterfly Valve

INSTALLATION & MAINTENANCE MANUAL

Rate B standard. Rate A Rate A option. max +260 C/ min -40 C

BUTTERFLY VALVE WAFER TYPE stainless steel 411 (41000) series PN40 For steam (fire safe versions) and 41001

Wafer, Lug and Double Flanged Type

Maintenance instruction

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF

NAF-Torex butterfly valves Maintenance and installation instructions List of spare parts

T 8053 EN Type and Type Pneumatic Control Valves Type 3252 High-pressure Valve

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

BUTTERFLY VALVE POWER-PACK CONTROLLED BUTTERFLY VALVE

Triple Eccentric Control and Shut-off Butterfly Valve Series 14t

YOUR GLOBAL FLOW CONTROL PARTNER. BRAY/MCCANNALOK EN High Performance Butterfly Valve Operation and Maintenance Manual

KTM Hindle Series 300 Ultra-Seal two piece metal seated ball valves Installation and Maintenance Instructions

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Operating instructions. Butterfly valves Series TRI-CON (with gear or actuator)

Series V2001 Valves Clean Tech Type 3321CT Globe Valve with pneumatic actuator

Uniwat. Resilient Seated Gate Valves

USER INSTRUCTIONS. Installation Operation Maintenance. Valtek Torex TX Control and shut-off valves. Butterfly Valves. Experience In Motion

COMPANY PROFILE TABLE OF CONTENT. Our products have been supplied to local and foreign customers for the following industries:

R o L. BUTTERFLY VALVE of carbon steel with flanges series BLUE LINE. Operation. Edition

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

SINGLE-ECCENTRIC BUTTERFLY VALVES TYPE L32.6

Power-Seal High Performance Butterfly Valve: Series P1 Installation & Maintenance Manual

BUTTERFLY VALVE WAFER TYPE of carbon steel ( ) series

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

FIVC. Static Balancing Valve. Technical data. Dimensions

Check Valves DN PN 80, 100, 160

SINGLE-ECCENTRIC BUTTERFLY VALVES TYPE L32.6

CONTROL BALL VALVES NPS 6 28 Class

SECTION VALVES PART 1 - GENERAL

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

BOA-CVP H. Type Series Booklet

The GACHOT V501 gate valve offer the most possible reliability for process and critical applications

Lined Butterfly Valve Pfeiffer Type BR 10a

KNIFE GATE VALVES -- MODEL A

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Sempell High Pressure Stop Valves Model VA510 (DIN)

Series 3331 Pneumatic Control Butterfly Valve Type 3331/BR 31a

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

AVK SERIES 55 AND 06 GATE VALVES, DN 450/500/600

16 bar standard 25 bar - option Tightness class ISO 5208, EN Standard - RATE B, Option RATE A RATE A. 16 bar standard 25 bar - option

Mounting and operating instructions EB 8093 EN. Series 240 Pneumatic Control Valve for Cryogenic Temperatures. Type and

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

Vexve Butterfly Valve User Manual p = PN 25 p = PN 20 (DN 1200)

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance.

KNIFE GATE VALVES -- MODEL D

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

Double Offset Butterfly Valve

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

NEOTECHA NEOSEAL BUTTERFLY VALVE INSTALLATION AND MAINTENANCE INSTRUCTIONS

VAG CEREX M300 Butterfly Valve

TABLE OF CONTENT. 7-Operating mechanisms of Non-return valve with hydraulic damping cylinder

High-pressure shut-off globe valve V30 High-pressure shut-off globe valve with control cone V40 PN , DN , T max : 550 C

Fig.01 Fig.02 Fig.03. Disassembly & Reassembly Instructions SBV-HP - Page 3

BUTTERFLY VALVE WAFER TYPE of carbon steel 311 ( ) series

Sempell High Pressure Stop Valves Model VA500 (DIN)

Easytork Vane Actuator IOM

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

Installation Operation Maintenance

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Transcription:

Operating Instructions For ABO Butterfly Valves, Series 3 E DN150-400 1. Introduction 2. Safety Instructions 3. Valve Model 4. Transportation and Storage 5. Installation into Piping 6. Pipe Pressure Test 7. Operation and Maintenance 8. Assistance in Case of Failure 9. Valves with Electric or Pneumatic Actuator 10. Other Information 0

1. Introduction Triple-offset butterfly valves, Series 3E DN150-400 have been designed for very demanding industrial applications requiring high security and reliability. They are mainly used in heat generation industry and applications with high temperature mediums (up to 500 C and pressure up to 40 bar see pressure/temperature diagram). 1

The correct type and material design is determined using brochures and technical data sheets, or consultations with the manufacturer. Check valves of Series 3 E are in full compliance with the directive CE/97/23. 2. Safety Instructions Installation, operation and maintenance may only be performed by properly trained and instructed staff. For detailed safety regulations see the separate document, which must be read carefully before installation. 3. Valve Model Valves come with a body with through holes (marked "B"), threaded holes (marked "T") of a flange or welded design. Inner diameter range: DN 150 to DN 400 Operating pressure: up to 40 bar Material design: carbon steel stainless steel Each butterfly valve is provided with an identification label in accordance with ČSN EN 19. Maximum and minimum operating temperatures TS max, TS min depending on the operating pressure PS for various material designs are listed in the charts included in the appropriate brochures. 4. Transportation and Storage Valves must be stored indoors in dry and dust-free environment at normal temperatures. Valves with manual gears, electric and double acting actuators are stored in a slightly open position (never fully closed!). Valves with spring pneumatic actuators are stored in fail safe position (open position with additional disc protection). Valves must always be handled in keeping with all the safety standards: Lifting and handling must be carried out by qualified staff, Use lifting equipment with sufficient load-bearing capacity, including loops and ropes, Three-point method of rope attachment (balancing) is recommended, 2

No part of the lifting system (loops...) may come into contact with the components of valve actuators. 5. Installation into Piping Butterfly valves may be installed in the piping system between two flanges. Instalation at the end of the pipe is allowed only with counter flange, or in the opposite direction without a counter flange ( T version only!) but with reduced allowed working pressure (Pworking x 0,7). Prior to the installation it is necessary to check whether the PN, DN and material design of the supplied valve corresponds to the intended use. The procedure is graphically described in the document Installation Instructions. Flanges with flat sealing surfaces e.g. B shape according to EN 1092 and also appropriate gasket must be used. Before installation it is necessary to examine: Whether the PN, DN and materials of the supplied valve correspond to the intended use. Whether no damage, namely to the sealing surfaces of the disc, occurred during transportation. Do not use damaged valves! Check the correct function of the valve (full opening and closing). The flanges must have a gasket strip, and they must be aligned and parallel, any impurities and solid particles must be removed from the flanges and piping. When manufactured, valves with a carbon steel body are preserved using the oil preservative RUST-PEL 51. (If stored for more than 6 months, a new preservation treatment is recommended). 3

Prior to putting into operation, the preservation of the valve body needs to be removed by using a warm aqueous solution containing a common detergent or solvent such as E 550 CLEAN or similar. A gasket made of a material resistant to the used medium is placed between the valve and the flange. The arrow on the body shows the direction of the flow (direction Δp). After centring the valve in the pipe, slightly tighten the 4 bolts and check if the disc moves freely. Tighten all the bolts ( in a cross-cross pattern"). The heads of the opposite bolts in "T" type bodies must not be in touched! After re-tightening the bolts check if the disc moves freely. 6. Pipe Pressure Test The actual valve is pressurized by the manufacturer. When fitted in the pipeline the entire pipe section with valves needs to be pressurized. The following must be taken in consideration: A newly installed section must be carefully rinsed (cleaned) to remove all the mechanical impurities, Valves in open position: pressure at 1.5 times the PN, Valves in closed position: pressure at 1.1 times the PN. 7. Operation and Maintenance Valves can be manually controlled using the appropriate force. The valves are maintenance-free, it is only necessary to check if the outer surface and the stem seal do not leak while in operation. If the valve remains in the same position for a long time, it is recommended to close and open the valve repeatedly at least 4 times per year. Mounting into the pipeline 4

8. Assistance in Case of Failure In case of failure and repair it is necessary to follow to all safety rules - see the separate document Safety Instructions. Failure Measure Note Leakage between the valve and flanges Leakage between the valve body and the flange Closure leakage Leakage around the stem Function defect 9. Valves with electric or pneumatic actuator The above principles fully apply to these valves. The positions of the actuators have been pre-set by the manufacturer and may not be adjusted. The inlet (or outlet) of controlling air in pneumatic actuators can be adjusted to avoid their quick closure and the water hammer in the pipes. Actuator mounted by the customer: Tighten the flange bolts. In case of ongoing leakage, replace the sealing between the valve and flanges. Repair by the manufacturer required. Check if the valve is fully closed. Open and close the valve repeatedly. If the leakage persists, repair by the manufacturer is required. All the nuts and gland retainer must be tightened (alternatively at a quarter of a turn). If the leakage persists, repair by the manufacturer is required. Remove and check the fitting. If damaged, send to the manufacturer. If the nut of the gland retainer must be removed, make sure the piping is not under pressure! See the Safety Instructions! Closing torque of the actuator must not be higher than maximum allowable stem torque see attached table (MAST)! Check actuator and valve connection! Do not use excessive force in assembly! The action of the axial force to the shaft is not allowed! 5

Electric actuators settings: - Set closing torque switch (min. closing torque x 1,25. Except DN200 34Lx where max. moment is 476Nm!) - Mechanical endstop for position close and position switch can not be used! - Set opening torque switch (opening moment x 1,25. Except DN200 34Lx where max. moment is 476Nm!) - Set mechanical endstop for position open and then set position switch Double action pneumatic actuators settings: - Compare opening and closing moment, choosing the higher and submit safety coefficient x 1,25 (or MAST torque when it is the lowest one) - For accuracy perform the calculation of required pressure and use the pressure reducer - Set only mechanical endstop for position open (stop end for close position must be free!) Spring to close pneumatic actuators settings: - Choose quantity of spring for min. closing torque x 1,25 (except DN200 34Lx where max. torque is 476Nm!) - Choose required air pressure for opening moment x 1,25 (except DN200 34Lx where max. torque is 476Nm!) and then set the pressure reducer. - Set only mechanical endstop for position open (endstop for position close must be free!) Spring to open pneumatic actuators settings: - Choose quantity of spring for opening torque x 1,25 (except DN200 34Lx where max. moment is 476Nm!) - Choose required air pressure for closing torque x 1,25 (except DN200 34Lx where max. moment is 476Nm!) and then set the pressure reducer. - Set only mechanical endstop for position open (endstop for position close must be free!) 6

Manual gear settings: - Compare opening and closing torque, choosing the higher and submit safety coefficient x 1,25 (or MAST value when is the lowest one) - Calculate diameter of handwheel for standard human strength by the standards of the country - Set only mechanical endstop for position open (endstop for position close must be free!) 10. INSTALLATION manual for the 3E valve (installation in piping or testing bench) 1) Place the valve into the testing bench (or in piping) in slightly open position 2) Gently fasten the valve between flanges 3) With respect to the specified operating torque fully close the valve 4) Completely finish the fastening of the valve between flanges Not observing of the above mentioned notes can cause damage or leakage of the valve To justify the eventual claim, it is necessary to respect above mentioned steps once installing the valve in piping. This installation process is mandatory for every installation of this type of the valve in piping or testing bench even the repeated one. 11. Other Information Correct shaft position on closed valve: Pressure tightness testing: 7

These regulations as well as other above-mentioned documents and further information also in other languages are available at www.abovalve.com or at the following address: ABO valve, s.r.o. Tel: 00420 585 223 955 Fax: 00420 585 223 984 abovalve@abovalve.com www.abovalve.com Last revision: 17 th February 2017 8