Ground Resistance Tester Model 3620 & 3620 Kits

Similar documents
FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Advanced Test Equipment Rentals ATEC (2832)

For all of your Ground T esting needs. Technical Hotline: (800) Ground Testers

Multi-Function Ground Resistance Tester Model 6472

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Digital/Analog Megohmmeter Model 1026

OPERATING INSTRUCTION

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

4-WIRE EARTH RESISTANCE TESTER C1 ES P1 S. Max. AC 200V MICROPROCESSOR CONTROLLED TEST. Switch ON, TEST, SCROLL RESULTS 20Ω 200Ω 2000Ω OFF

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

Digital Insulation Resistance Testers. you can depend on

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

USER MANUAL. Insulation Tester + DMM. Model MG320

User's Manual. Earth Ground Resistance Tester. Model Introduction

MOM2 Handheld High Current Micro-ohmmeter

2-Color Display High-Precision Digital Pressure Switch

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Model Insulation Tester / Megohmmeter. User Manual

AC CURRENT ANALOG CLAMP-ON TESTER MODEL MCL-350 INSTRUCTION MANUAL

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Dawson DDM190D. Digital Multimeter User s Manual

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Hour Meter Series HM36

Model Number Structure

User Guide. Model Insulation Tester / Megohmmeter. Introduction

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

User Guide. Model Insulation Tester / Megohmmeter

OPERATING INSTRUCTION

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

Model Pressure range ON/OFF output Linear output

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

MOM2 Micro-ohmmeter APPLICATIONS DESCRIPTION. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Digital Transformer Ratiometer

MEGOHMMETER. User Manual

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

Switching Power Supply

2-Color Display High-Precision Digital Pressure Switch

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL

User Guide. Model Insulation Tester / Megohmmeter

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

HL (AZH) LIMIT SWITCHES

Digital display Pressure range ON/OFF output Linear output Model

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

OPERATING INSTRUCTION

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

DIGITAL RCD(ELCB) TESTER

MIT515, MIT525, MIT1025, MIT1525

KMP Insulation-Continuity Tester. Users Manual

Digital Multimeter User's Manual

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Inductive Proximity Sensor

90HJRKPPHWHU 0RGHO1 (6'&RQGX WLYLW\7HVW.LW

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Volt/mA Calibrator. Manual

KMP7010. Ground Resistance Tester. Users Manual

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

HL (AZH) Limit Switches

Power Switching Devices

PAT120, PAT150 and PAT150R

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

Inductive Proximity Sensor

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

DLRO-H200 Microhmmeter

HL (AZH) Limit Switches

Attention ETCR8600 Leakage Protector Tester To read this user manual carefully. To comply with the operating cautions presented in this manual.

Analog input module. Brief description. Page 1/8. Data Sheet

Weatherproof Tubular Slip Ring Assembly

EPS/ELA-Series User Manual EPS/ELA 250W

USERS MANUAL MCD REMOTE OPERATOR

S1-568, S1-1068, S1-1568

DIGITAL MULTIMETER INSTRUCTION MANUAL

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES

MCD Pump Application Module

B3F. Miniature, Space-saving Switch

MOM2 Microhmmeter. MOM2 Microhmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Dawson DAN100. Analog Multimeter User s Manual

E2EZ-X2D1-N E2EZ-X2D2-N

K100 K110 AEMC INSTRUMENTS ENGLISH. User Manual. n DC/AC MICROPROBE. Model K mv/ma OFF. DC/AC MicroProbe

Advanced Test Equipment Rentals ATEC (2832)

1.Safe testing IMPORTANT:

DC TO AC POWER INVERTER USER INSTRUCTION MANUAL. Applicable for: FTS800/FTS1000/FTS1500

SafeTest 60. A simple, robust and cost-effective medical safety analyser for general electrical safety testing. Key Features

Transcription:

Ground Resistance Tester Model 3620 & 3620 Kits Model 3620 shown in standard soft carrying case Catalog #2114.90 The Analog Ground Resistance Tester Model 3620 performs ground resistance measurements from 0.5 to 1000Ω with speed and accuracy. The Model 3620 features three-terminal operation for Fall-of-Potential earth/ ground resistance and also may be used for 2-Point tests. The large 3.1" logarithmic analog scale is easy to read, with a separate marking for 25Ω. A large Press-to-Measure button allows for easy measurements. A manual zero adjust is provided for accurate readings. Color-coded binding post terminals are easy-to-use with banana plug and spade lug inputs. The heavy duty ABS case is O-ring sealed against dust and water, and the Press-to-Measure button is also sealed. The Ground Tester Model 3620 is battery powered, for convenient use in remote field applications. Mechanical and safety specifications, such as vibration and drop test, meet or exceed IEC standards, to ensure safe and reliable field use. The Ground Resistance Tester Model 3620 is the ideal instrument for electrical contractors, power utilities, REAs, telephone and CATV technicians, and inspectors who must check ground to determine compliance with NEC, OSHA and other specifications.

Features Fall-of-Potential method for 2- and 3-Point ground resistance tests Direct reading on large analog display 0.5 to 1000Ω and easy 25Ω readings Large 3.1" (77mm), easy-to-read scale for accurate readings Built-in battery check Three color-coded terminals Large Press-to-Measure button Specifications Portable and compact Extremely simple to operate: connect press read Designed to reject high levels of noise and interference Double Insulation CE Mark Applications Measuring earth resistance of the type of single rod or small ground grids often found in remote telecommunication switching sites Measuring ground electrode resistance of lightning protection equipment Measuring the earth electrode resistance of equipment in recreational areas Testing electrode resistance of ground rods and grids at new construction sites, when utility supplied power has not been supplied Testing earth electrode resistance of grounded towers at cellular phone remote installations ELECTRICAL Range 0.5 to 1000Ω Resolution 10mΩ Test Current 10mA Resistance Measurement Frequency 128Hz square wave Accuracy ±5% of Reading + 0.1% of galvanometer scale length Auxiliary Electrode Influence Rz 3000 times the reading up to 50kΩ Ry 50kΩ Withstanding Voltage 250Vrms with spikes of 3000VAC or 1000VDC Power Source Eight 1.5V AA Alkaline batteries Battery Life 1680 15-second tests (approximately) Fuse Protection High breaking capacity 0.1A, >250V, 0.25 x 1.25" MECHANICAL Display Analog Pivot movement Connection Color-coded terminals accept spade lugs with minimum gap of 6mm or standard 4mm banana jacks Scale 3.1" (77mm) white scale with black pointer; one scale per range Operating Temperature 14 to 131 F (-10 to 55 C) Storage Temperature -40 to 158 F (-40 to 70 C), 0 to 90% RH with batteries removed Temperature Influence 5% per 10 C Relative Humidity 20 to 90% maximum Dimensions 8.7 x 5.4 x 5.9" (220 x 136 x 150mm) Weight 2 lbs (1.3kg) Case Heavy-duty, ABS Colors Case safety yellow; Front panel gray Mechanical Shock IEC 68-2-27 Vibration Test IEC 68-2-6 Drop Test IEC 68-2-32 Environmental O-ring sealed against dust and water to IP50 SAFETY Rating EN 61010-1, Cat. III, Pollution Degree 2, 24V Agency Approval Emission: EN 50081-1 Immunity: EN 50082-1 Double Insulation Yes CE Mark Yes Technical Assistance (800) 343-1391 www.aemc.com 2 of 5

Ground Kits Test Kit for 3-Point testing includes instrument, two 150 ft color-coded leads on spools (red and blue), one 30 ft lead (green), two 14.5" T-shaped auxiliary ground electrodes, one set of five spaded lugs, 100 ft tape measurer and carrying bag. Catalog #2135.10 Test Kit for 4-Point testing includes instrument, two 300 ft color-coded leads on spools (red and blue), two 100 ft color-coded leads (green and black), four 14.5" T-shaped auxiliary ground electrodes, one set of five spaded lugs, Catalog #2135.11 Test Kit for 4-Point testing includes instrument, two 500 ft color-coded leads on spools (red and blue), two 100 ft color-coded leads (green and black), one 30 ft lead (green), four 14.5" T-shaped auxiliary ground electrodes, one set of five spaded lugs, Catalog #2135.12 Technical Assistance (800) 343-1391 www.aemc.com 3 of 5

Construction Input terminals Press-to-Measure button LED measurement fault indicators: X-Z Fault X-Y Hi Resistance X-Y Hi Noise Analog display Zero adjustment screw ORDERING INFORMATION CATALOG NO. Ground Resistance Tester Model 3620 (3-Point Analog)............................................. Cat. #2114.90 Includes soft carrying case, batteries and user manual Ground Resistance Tester Model 3620 Kit 150 ft................................................. Cat. #2135.10 Test Kit for 3-Point testing includes meter, two 150 ft color-coded leads on spools (red and blue), one 30 ft lead (green), two 14.5" T-shaped auxiliary ground electrodes, one set of five fork terminals, Ground Resistance Tester Model 3620 Kit 300 ft................................................. Cat. #2135.11 Test Kit for 4-Point testing includes two 300 ft color-coded leads on spools (red and blue), two 100 ft color-coded leads (green and black), four 14.5" T-shaped auxiliary ground electrodes, one set of five fork terminals, Ground Resistance Tester Model 3620 Kit 500 ft................................................. Cat. #2135.12 Test Kit for 4-Point testing includes two 500 ft color-coded leads on spools (red and blue), two 100 ft color-coded leads (green and black), one 30 ft lead (green), four 14.5" T-shaped auxiliary ground electrodes, one set of five fork terminals, Accessories (Optional) 25Ω Calibration Checker........................................................................ Cat. #2130.59 Tape Measure (100 ft).......................................................................... Cat. #2130.60 Ground Tester Video/Workbook set................................................................ Cat. #2130.64 Technical Assistance (800) 343-1391 www.aemc.com 4 of 5

Technical Assistance (800) 343-1391 www.aemc.com 5 of 5