1. DBS series. Applications Manual

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

DC9~ typ max 40max 80max. 71 typ max. 120max 120max. 120max. 120max. 60max. 48max. 20max

Applications Manual. Table of contents. 1. DBS series. 2. CBS series. 3. CDS series. 4. Application Circuits. 6. DPA and DPF series. 7.

LS200 Series Instruction Manual

Applications Manual of DPG serises

MODEL LEP100F-24 LEP100F-36 LEP100F-48 DC OUTPUT +24V 4.2(Peak 7)A +36V 2.8(Peak 4.7)A +48V 2.1(Peak 3.5)A

ZWD100PAF Series Instruction Manual

ZWD225PAF Series Instruction Manual

ZWS-BP Series. Instruction Manual. TDK-Lambda. ZWS-BP Series. Instruction Manual A C

<Designed to meet harmonic current regulations> Board type, ultra-small size, and low cost

(DC/DC) SERIES to 96.5% (typical) Product Lineup. Ordering Information. Features. General Description. Super high efficiency

TDK-Lambda ZWS240BP/A SPECIFICATIONS

HWS 15A-150A Series. Instruction Manual

Basic Characteristics Data

ZWS-BAF Series. Instruction Manual. TDK-Lambda. ZWS-BAF Series Instruction Manual A H

Table 2 Models BST12M-0.7S03PDM BST12M-0.7S06PDM BST12M-0.7S10PDM Conditions Input voltage range

DRB-1 Series Instruction Manual

PFE700SA Series Instruction Manual

DRL-1 Series Instruction Manual

Dual output. Fig. 2.1 Current foldback characteristics

CCG Series Instruction Manual

MODEL MMC8A-1 MMC8A-2 MMC8A-3 V1 +5V 1.2A +5V 1.1A +5V 1.2A DC OUTPUT V2 +12V 0.1A +15V 0.1A +12V 0.1A V3-12V 0.1A -15V 0.1A -5V 0.

PAF SERIES. Features. Model naming method PAF 500 F / Conformity to RoHS Directive. Applications. Product Line up. DC/DC Module 400W-700W PAF

PAF F280 SERIES Instruction Manual

PAF500F24 SERIES Instruction Manual

(typ.) (Range) ±18 330# 89 MPW MPW

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

EVS RP6020. Instruction Manual

TDK-Lambda ZWS300BAF/A

CN100A110 SERIES Instruction Manual

TDK Lambda TEP INSTRUCTION MANUAL

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Instruction Manual PFE500F 1000F SERIES. TDK-Lambda PFE500F 1000F Series INSTRUCTION MANUAL

GB60S 60W Single Output General Purpose Series

Instruction Manual. TDK-Lambda. PFE300SA 500SA Series INSTRUCTION MANUAL

PFE1000FA Series. Instruction Manual

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

RP Instruction Manual

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

CN-A110 SERIES Instruction Manual

NXE1 Series Isolated 1W Single Output SM DC/DC Converters

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

Features. Description. Table of Contents

+Vin. -Vin PO RC ALM. Fig. 1 Connection Method

Small Type High-Speed Response POL DC-DC Converter BSV-nano Series

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

(typ.) (Range) Load

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

Five Improvements by Power Supply Modules. Switching power supply and power modules. External Dimensions / Pin assignment, SPM Series

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

EPM1510SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

Switching Power Supply

2W, Low Cost DIP, Dual Output DC/DC Converters

PAF F48 SERIES Instruction Manual

ZWD100PAF. Conformity to RoHS Directive

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Power Modules (Power Supplies with Ultra-low Standby Power Consumption) DC V

NXE1 Series Isolated 1W Single Output SM DC-DC Converters

MPM0527SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input reflected ripple current. Switching frequency NXE1S0305MC 85

NMA 5V, 12V & 15V Series Isolated 1W Dual Output DC/DC Converters

QHW050F1, QHW075F1, and QHW100F1 Power Modules: dc-dc Converters; 36 to 75 Vdc Input, 3.3 Vdc Output; 33 W to 66 W

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Maximum input voltage 420V or less Including peak value

MODEL TUNS50F05 TUNS50F12 TUNS50F24 VOLTAGE[V]

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Power Supply Technical Information

POWER-WIN TECHNOLOGY CORP.

NTA Series Isolated 1W Dual Output SM DC/DC Converters

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

SELECTION GUIDE. Order code B0303NXT-1W B0305NXT-1W B0309NXT-1W

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Reflected ripple current. Case Temperature rise above ambient ABSOLUTE MAXIMUM RATINGS

Transcription:

Basic Characteristics Data Basic Characteristics Data Model 1F 15F 2F 3F Circuit method Switching frequency [khz] Active filter 6 Forward converter 13 Active filter 6 Forward converter 13 Active filter 6 Forward converter 13 Active filter 6 Forward converter 1 *1 The value of input current is at ACIN 1V and rated load. *2 Refer to 2. Input current *1 [A] Inrush current protection PCB/Pattern Material Single sided Double sided Series/Parallel operation availability *2 Series operation Parallel operation 1.3 Thermistor CEM-3 Yes Yes No 2. Thermistor CEM-3 Yes Yes No 3.6 SCR CEM-3 Yes Yes No 4.3 SCR CEM-3 Yes Yes No -1

1 Function -12 1.1 Input voltage range 1.2 Inrush current limiting 1.3 Overcurrent protection 1.4 Overvoltage protection 1.5 Thermal protection 1.6 Output voltage adjustment range 1.7 Output ripple and ripple noise 1. Isolation 1.9 Reducing standby power -12-12 -12-12 -12-12 -12-13 -13 2 Series Operation and Parallel Operation -13 2.1 Series Operation 2.2 Parallel Operation -13-13 3 Assembling and Installation -13 3.1 Installation method 3.2 Derating 3.3 screw 3.4 Expectancy life and warranty -13-13 -15-16 4 Ground -16 5 Peak loading -17 6 Option and Others -17 6.1 Outline of options 6.2 Others -17-19 -11

1 Function 1.1 Input voltage range The range is from AC5V to AC264V or DC12V to DC37V (please see SPECIFICATIONS for details). In cases that conform with safety standard, input voltage range is AC1-AC2V (5/6Hz). If input value doesn t fall within above range, a unit may not operate in accordance with specifi cations and/or start hunting or fail. If you need to apply a square waveform input voltage, which is commonly used in UPS and inverters, please contact us. When the input voltage changes suddenly, the output voltage accuracy might exceed the specifi cation. Please contact us. Operation stop voltage is set at a lower value than that of a standard version (derating is needed). -Use Conditions Output 1F 3W 15F 5W 2F W 3F 1W Input AC5V or DC7V Duty 1s/3s 1.2 Inrush current limiting An inrush current limiting circuit is built-in. If you need to use a switch on the input side, please select one that can withstand an input inrush current. 1F, 15F Thermistor is used in the inrush current limiting circuit. When you turn the power ON/OFF repeatedly within a short period of time, please have enough intervals so that a power supply cools down before being turned on. 2F, 3F Thyristor technique is used in the inrush current limiting circuit. When you turn power ON/OFF repeatedly within a short period of time, please have enough intervals so that the inrush current limiting circuit becomes operative. When the switch of the input is turned on, the primary inrush current and secondary inrush current will be generated because the thyristor technique is used for the inrush current limiting circuit. 1.3 Overcurrent protection An overcurrent protection circuit is built-in and activated at 11% of the peak current. A unit automatically recovers when a fault condition is removed. Please do not use a unit in short circuit and/or under an overcurrent condition. Intermittent Operation Mode Intermittent operation for overcurrent protection is included in a part of series. When the overcurrent protection circuit is activated and the output voltage drops to a certain extent, the output becomes intermittent so that the average current will also decrease. -12 * Please avoid using continuously for more than 1 second under above conditions. Doing so may cause a failure. 1.4 Overvoltage protection An overvoltage protection circuit is built-in. If the overvoltage protection circuit is activated, shut down the input voltage, wait more than 3 minutes and turn on the AC input again to recover the output voltage. Recovery time varies depending on such factors as input voltage value at the time of the operation. In option -R2, overvoltage protection is removed by toggling ON/ OFF signal of remote control. Remarks : Please avoid applying a voltage exceeding the rated voltage to an output terminal. Doing so may cause a power supply to malfunction or fail. If you cannot avoid doing so, for example, if you need to operate a motor, etc., please install an external diode on the output terminal to protect the unit. 1.5 Thermal protection A thermal protection circuit is built-in. The thermal protection circuit may be activated under the following conditions and shut down the output. 1 When a temperature continue to exceed the values determined by the derating curve. 2 When a current exceeding the rated current is applied. 3When convection stops. 4 When peak load is applied in conditions other than those shown in Section 5. If the thermal protection circuit is activated, shut off the input voltage and eliminate all the overheating conditions. To recover the output voltage, have enough time to cool down the unit before turning on the input voltage again. 1.6 Output voltage adjustment range Adjustment of output voltage is possible by using potentiometer. 1.7 Output ripple and ripple noise Output ripple noise may be infl uenced by measurement environment, measuring method fi g.1.1 is recommended. +Vout -Vout Osiloscope/ Ripple noise meter Bw:2MHz C1 C2 15mm C1 : Film capacitor.1μf C2 : Aluminum electrolytic capacitor 22μF + Load Differential probe Fig.1.1 Measuring method of Ripple and Ripple Noise Remarks : When GND cable of probe with fl ux of magnetic force from power supply are crossing, ripple and ripple noise might not measure correctly. Please note the measuring environment.

Even a slight difference in output voltage can affect the balance between the values of I1 and I2. Please make sure that the value of I3 does not exceed the rated current of a power supply. I3 [ the rated current value Bad example Good example Fig.1.2. Example of measuring output ripple and ripple noise 1. Isolation For a receiving inspection, such as Hi-Pot test, gradually increase (decrease) the voltage for the start (shut down). Avoid using Hi- Pot tester with the timer because it may generate voltage a few times higher than the applied voltage, at ON/OFF of a timer. 1.9 Reducing standby power As for option -R2, reducing standby power is possible by OFF signal of the remote control. Please refer to instruction manual 6.1. 3 Assembling and Installation 3.1 Installation method This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,so handle the unit with care. In case of metal chassis, keep the distance between d1 & d2 for to insulate between lead of component and metal chassis, use the spacer of mm or more between d1. If it is less than d1 & d2, insert the insulation sheet between power supply and metal chassis. d2 2 Series Operation and Parallel Operation d2 d1= mm min d2 2.1 Series Operation You can use a power supply in series operation. The output current in series operation should be lower than the rated current of a power supply with the lowest rated surrent among power supplies that are serially connected. Please make sure that no surrent exceeding the rated current fl ows into a power supply. Power + Supply - Power + Supply - Load Power + Supply - Power + Supply - Load Load d2 d2 = 4mm min d2 Fig.3.1 Installation method There is a possibility that it is not possible to cool enough when the power supply is used by the sealing up space as showing in Figure 3.2. Please use it after confi rming the temperature of point A and point B of 3.2. Case Fig.2.1 Examples of connecting in series operation 2.2 Parallel Operation Parallel operation is not possible. Redundancy operation is available by wiring as shown below. Power Supply Power Supply + - + - I1 I2 I3 Load Fig.2.2 Example of redundancy operation 3.2 Derating Power supply Fig.3.2 Installation example Environment to use it and Installation environment When using it,it is necessary to radiate heat by the heat of the power supply. Table 3.1-3.4 shows the relation between the upper limit temperature (Point A and Point B) and load factors. Please consider the ventilation so that the convection which is enough for the whole power supply is provided. And temperature of Point A and Point B please become lower than upper limit temperature. -13

The expectancy life in the upper bound temperature (Point A and Point B) is three years or more. Please refer to External View for the position of Point A and Point B. In case of with Chassis and Cover, please contact our sales office for getting more information. Remarks: *Please be careful of electric shock or earth leakage in case of temperature measurement, because Point A and Point B is live potential. *Please refer to 3.4 if you want to extend the longevity of the expectancy life. Table 3.1 Temperatures of Point A, Point B 1F-O-Y Max temperature Load factor Point A[C] Point B[C] 75%<Io[1% 6 5%<Io[75% 9 9 %<Io[5% 9 9 75%<Io[1% 2 1 5%<Io[75% 9 9 %<Io[5% 9 9 75%<Io[1% 5 6 5%<Io[75% 9 9 %<Io[5% 9 9 75%<Io[1% 4 76 D Convection 5%<Io[75% 9 6 %<Io[5% 9 9 75%<Io[1% 1 9 E Convection 5%<Io[75% 6 9 %<Io[5% 7 9 75%<Io[1% 77 F Convection 5%<Io[75% 5 6 %<Io[5% 9 A,B,C,D,E,F Forced air 7%<Io[1% 75 75 %<Io[7% 75 75 Table 3.2 Temperatures of Point A, Point B 15F-O-Y Max temperature Load factor Point A[C] Point B[C] 75%<Io[1% 4 1 5%<Io[75% 9 9 %<Io[5% 9 9 75%<Io[1% 3 1 5%<Io[75% 9 9 %<Io[5% 9 9 75%<Io[1% 7 5 5%<Io[75% 9 9 %<Io[5% 9 9 75%<Io[1% 3 65 D Convection 5%<Io[75% 9 75 %<Io[5% 9 5 75%<Io[1% 77 6 E Convection 5%<Io[75% 1 9 %<Io[5% 6 9 75%<Io[1% 7 76 F Convection 5%<Io[75% 2 2 %<Io[5% 9 9 A,B,C,D,E,F Forced air 7%<Io[1% 75 75 %<Io[7% 75 75-14 Table 3.3 Temperatures of Point A, Point B, Point C 2F-O-Y Max temperature Load factor Point A[C] Point B[C] Point C[C] 75%<Io[1% 9 2 5%<Io[75% 9 %<Io[5% 9 9 75%<Io[1% 5 74 5%<Io[75% 9 2 %<Io[5% 9 9 75%<Io[1% 9 3 5%<Io[75% 9 %<Io[5% 9 9 75%<Io[1% 74 D Convection 5%<Io[75% 9 5 %<Io[5% 9 9 75%<Io[1% 9 6 E Convection 5%<Io[75% 9 9 %<Io[5% 9 9 75%<Io[1% 79 6 F Convection 5%<Io[75% 6 77 %<Io[5% 9 9 A,B,C,D,E,F Forced air 7%<Io[1% 75 75 5 %<Io[7% 75 75 5 Table 3.4 Temperatures of Point A, Point B, Point C, Point D 3F-O-TY Max temperature Load factor Point A[C] Point B[C] Point C[C] Point D[C] %<Io[1% 7 6 6%<Io[% 75 Io[6% 79 9 %<Io[1% 59 6 6%<Io[% 6 76 Io[6% 76 6 %<Io[1% 7 4 6%<Io[% 77 9 Io[6% 9 %<Io[1% 57 64 D Convection 6%<Io[% 65 73 Io[6% 77 3 %<Io[1% 6 79 E Convection 6%<Io[% 66 1 Io[6% 76 A,B,C,D and E Forced air 5%<Io[1% 75 75 5 5 Io[5% 75 75 5 5 The operative ambient temperature is different by with / without chassis cover or position. Derating curve is shown below. Note: In the hatched area, the specification of Ripple, Ripple Noise is different from other area. 1F Load factor [%] 1 7 6 5 3 2 1 (D), (E), (F) 1(C) 1(B) 1Convection 2Forced air (.5m 3 /min) -1 1 2 3 35 45 5 6 7 Ambient temperature [C] 1(A) 2 (A) ~ (F) Fig.3.3 Ambient temperature derating curve (refer to Table 3.1)

15F Load factor [%] 1 7 6 5 3 2 1(D), (E), (F) 1Convection 2Forced air (.5m 3 /min) 1(C) 1(B) -1 1 2 3 45 5 6 7 Ambient temperature [C] 1(A) 2 (A) ~ (F) Fig.3.4 Ambient temperature derating curve (refer to Table 3.2) 2F Load factor [%] 1 7 6 3 2 1 (D), (E) 1 (C) 1 (B) 1 (F) 1 (A) 1Convection 2Forced air (.5m 3 /min) -1 1 2 25 3 35 45 5 6 7 Ambient temperature [C] Output Output power[w] voltage 1Convection 2Forced air 24V 2. 3. 3V 2. 3. 36V 241.2 32.4 4V 2. 32.4 2 (A) ~ (F) Fig.3.5 Ambient temperature derating curve (refer to Table 3.3) 3F Load factor [%] 1 6 5 1Convection 2Forced air (.5m 3 /min) 1 (B), (C) 1 (D), (E) 1 (A) 2 1-1 1 2 25 3 5 6 7 Ambient temperature [C] Output Output power[w] voltage 1Convection 2Forced air 24V 3. 36. 3V 3. 36. 36V 32.4 36. 4V 32.4 36. 2 (A) ~ (E) Fig.3.6 Ambient temperature derating curve (refer to Table 3.4) Derating curve depending on input voltage Derating curve depending on input voltage is shown in Fig.3.7. Load factor [%] 1 method (A) (B) (C) Standard Position (D) (E) (F) Fig.3. method (F) of 3F is not possible. (F) is not possible when unit is with case cover, but if need to operate unit by (F) positioning with case cover, temperature / load derating is necessary. For more details, please contact our sales or engineering departments. 3.3 screw The screw should be M3. The hatched area shows the allowance of metal parts for. If metallic fi ttings are used on the component side of the board, ensure there is no contact with surface mounted components. This product uses SMD technology. Please avoid the PCB installation method which includes the twisting stress or the bending stress. *Recommendation to electrically connect FG to metal chassis for reducing noise. 1F, 15F Fig.3.9 Allowance of metal for 2F, 3F, TB1 Unit [mm] [AC V] 5 9 Fig.3.7 Derating curve depending on input voltage Fig.3.1 Allowance of metal for Unit [mm] -15

3.4 Expectancy life and warranty Expectancy Life. Table 3.5 Expectancy Life (1F-O-Y) Expectancy Life Ta = C or less 6years 6years Ta = 5C 6years 5years Ta = 35C or less 6years 6years Ta = 45C 6years 5years D, E, F Convection Ta = 25C or less 5years 5years Ta = 35C 5years 3years A,B,C,D,E,F Forced air Ta = 6C 5years 3years Warranty Table 3.9 Warranty (1F-O-Y) Warranty Ta = C or less 5years 5years Ta = 5C 5years 3years D, E, F Convection Ta = 25C or less 5years 5years Ta = 35C 5years 3years A,B,C,D,E,F Forced air Ta = 6C 5years 3years Table 3.6 Expectancy Life (15F-O-Y) Expectancy Life Ta = C or less 6years 6years Ta = 5C 6years 5years Ta = 35C or less 6years 6years Ta = 45C 6years 5years D, E, F Convection Ta = 2C or less 5years 5years Ta = 3C 5years 3years A,B,C,D,E,F Forced air Ta = 6C 5years 3years Table 3.1 Warranty (15F-O-Y) Warranty Ta = C or less 5years 5years Ta = 5C 5years 3years D, E, F Convection Ta = 2C or less 5years 5years Ta = 3C 5years 3years A,B,C,D,E,F Forced air Ta = 6C 5years 3years Table 3.7 Expectancy Life (2F-O-Y) Expectancy Life Ta = C or less 6years 6years Ta = 5C 6years 5years Ta = 35C or less 6years 6years Ta = 45C 6years 5years Ta = 25C or less 5years 5years Ta = 35C 5years 3years D, E Convection Ta = 2C or less 5years 5years Ta = 3C 5years 3years F Convection Ta = 25C or less 5years 3years A,B,C,D,E,F Forced air Ta = 6C 5years 3years Table 3.11 Warranty (2F-O-Y) Warranty Ta = C or less 5years 5years Ta = 5C 5years 3years Ta = 25C or less 5years 5years Ta = 35C 5years 3years D, E Convection Ta = 2C or less 5years 5years Ta = 3C 5years 3years F Convection Ta = 25C or less 5years 3years A,B,C,D,E,F Forced air Ta = 6C 5years 3years Table 3. Expectancy Life (3F-O-TY) Expectancy Life Ta = 3C or less 6years 6years Ta = C 5years 3years B, Ta = 2C or less 6years 6years Ta = 3C 5years 3years D, E Convection Ta = 25C or less 6years 5years A,B,C,D,E Forced air Ta = 5C 5years 3years Table 3.12 Warranty (3F-O-TY) Warranty Ta = 3C or less 5years 5years Ta = C 5years 3years B, Ta = 2C or less 5years 5years Ta = 3C 5years 3years D, E Convection Ta = 25C or less 5years 3years A,B,C,D,E Forced air Ta = 5C 5years 3years 4 Ground When installing the power supply with your unit, ensure that the input FG terminal of or hole FG is connected to safety ground of the unit. -16

5 Peak loading Peak load is possible to draw as below. Duty [%] 1 AC1V 2 AC2V Output current [A] t [sec] t 1 t 2 l P lave : average current l O : peak current 1 3 36 51 5 6 Peak Wattage[W] 3F Fig.5.1 Derating of peak loading t 1 [ 1 [sec], lave = I P t 1+I O t 2 t 1+t 2 [ rated current, 6 Option and Others t 1 t 1+t 2 [. (Refer to below chart) Duty [%] Duty [%] Duty is depended on peak load, refer to below chart. 1 AC1V 2 AC2V 2 1 1 16 2 2 1 Peak Wattage[W] 1F 15 2 3 Peak Wattage[W] 15F 1 AC1V 2 AC2V 1 AC1V 2 AC2V 3 Forced air 6.1 Outline of option -C -Option -C units have coated internal PCB for better moisture resistance. -G -Option -G units are low leakage current type. -Differences from standard versions are summarized in Table 6.1. Table 6.1 Low leakage current type Leakage Current.15mA max (AC2V 6Hz) Conducted Noise N/A Please contact us for details about Output Ripple Noise Ripple Noise * This is the value that measured on measuring board with capacitor of 22μF at 15mm from output connector. Measured by 2MHz oscilloscope or Ripple-Noize meter (Equivalent to KEISOKU-GIKEN:RM-13). -J (3F) -Option -J units, the input and output connector are changed to EP connectors (Mfr. Tyco Electronics). -The appearance in option -J units is defferent from the standard untis. Please contact us about the detail. Duty [%] 2 15 1 2 36 Peak Wattage[W] 2F -J1 -Option -J1 units, the Input and Output connector is VH connectors (Mfr. J.S.T.). -3F appearance of option -J1 units is defferent from the standard appearance. Please contact us about the detail. -S--SN --S indicates a type with chassis, and -SN indicates a type with chassis and cover (Refer to external view). Please contact us about the detail of derating curve. -Please contact us about the detail of 3F. -17

-SNF (3F-24-TY) -In option -SNF, the cover, chassis and cooling fan are added. -The appearance of option -J and -J1 units is defferent from the of standard appearance. Please contact us about the detail. -Oil and other chemical liquid splashing environment may cause the performance degradation and failure. -R -You can control output ON/OFF remotely in Option -R units. To do so, connect an external DC power supply and apply a voltage to a remote ON/OFF connector, which is available as option. Model Name 1F, 15F 2F, 3F Built-in Resistor Ri [ W ] Voltage between RC (+) and RC (-) [V] Output ON Output OFF Input Current [ma] 7 4.5-12.5 -.5 2max -T (2F, 3F) -Option -T units have vertically positioned screws on a terminal block. -Please contact us for details about appearance. FG AC (N) -V AC (L) +V Fig.6.2 Example of option -T The screw can be held to terminal block by inserting and lifting the screwdriver from the side of terminal block. + screwdriver screw R *1 SW RC (+) 1 Inside of a Power Supply Ri terminal block External Power Source Input Current RC (-) 2 f5.5max Remote ON/OFF connector (Optional) Fig.6.1 Example of using a remote ON/OFF circuit - Dedicated harnesses are available for your purchase. Please see Optional Parts for details. *1 If the output of an external power supply is within the range of 4.5-12.5V, you do not need a current limiting resistor R. If the output exceeds 12.5V, however, please connect the current limiting resistor R. To calculate a current limiting resistance value, please use the following equation. R[W]= Vcc-(1.1+RiX.5).5 * Please wire carefully. If you wire wrongly, the internal components of a unit may be damaged. Remote ON/OFF circuits (RC+ and RC-) are isolated from input, output and FG. -R2 -The usege is the same as option -R, please refer to Option -R. -Reducing standby power is possible by OFF signal of the remote control. -Start up time by ON signal in remote control is 35ms(typ). -The latch condition in overvoltage protection is removed by toggling ON/OFF signal of remote control. -Standby power 1F, 15F, 2F.2Wtyp (AC1V),.7Wtyp (AC2V) 3F.25Wtyp (AC1V), 1.1Wtyp (AC2V) -1 -T1 (3F) Fig.6.3 lifting method -Option -T1 units have horizontally positioned screws on a terminal block. -Please contact us for details about appearance. FG AC (N) AC (L) Fig.6.4 Example of option -T1 -U1 (2F, 3F) By connecting the external capacitor unit CR-HUT(optional parts), Hold-up time is extensible. Hold-up time [ms] 1, 1, 1 1 5 1 15 2 25 3 Output power [W] -V +V External capacotor unit model CR-HUT52-2 CR-HUT22-2 CR-HUT721-1 CR-HUT241-1 Fig.6.5 Hold-up time by 2F-O-U1Y(Reference data).

1, Hold-up time [ms] 1, 1 External capacotor unit model CR-HUT52-2 CR-HUT22-2 CR-HUT721-1 CR-HUT241-1 1 5 1 15 2 25 3 35 Output power [W] Fig.6.6 Hold-up time by 3F-O-TU1Y(Reference data). Connection method Power supply VC(+) VC(-) d=5-3mm Harness H-IN-23 (sell separately) VC(+) VC(-) External capacitor unit (CR-HUT) Fig.6.7 Connection method Caution (1) Distance between the external capacitor unit and power supply unit must be secured more than 5mm. (2) It must be 3mm or less, since the noise is generated from the wire which is connecting the external capacitor unit and power supply. And, it is necessary to twist the wire as short as possible. (3) It is necessary to use wires which rated voltage is 6V or more. (4) It must be used with the external capacitor unit (CR-HUT). (5) For more information about the external capacitor unit and harness, please refer to the page to optional parts. 6.2 Others This power supply is the rugged PCB type. Do not drop conductive objects in the power supply. At light load, there remains high voltage inside the power supply for a few minutes after power OFF. So, at maintenance, take care about electric shock. This power supply is manufactured by SMD technology. The stress to PCB like twisting or bending causes the defect of the unit, so handle the unit with care. -Tighten all the screws in the screw hole. -Install it so that PCB may become parallel to the clamp face. -Avoid the impact such as drops. While turning on the electricity, and for a while after turning off, please don t touch the inside of a power supply because there are some hot parts in that. When a mass capacitor is connected with the output terminal (load side), the output might become the stop or an unstable operation. Please contact us for details when you connect the capacitor. -19