Basic Characteristics Data

Similar documents
Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

1 Terminal Block A-22

Basic Characteristics Data

DC9~ typ max 40max 80max. 71 typ max. 120max 120max. 120max. 120max. 60max. 48max. 20max

1. DBS series. Applications Manual

LS200 Series Instruction Manual

Basic Characteristics Data

DRB-1 Series Instruction Manual

Basic Characteristics Data

Basic Characteristics Data

Applications Manual. Table of contents. 1. DBS series. 2. CBS series. 3. CDS series. 4. Application Circuits. 6. DPA and DPF series. 7.

DRL-1 Series Instruction Manual

ZWD100PAF Series Instruction Manual

ZWD225PAF Series Instruction Manual

CCG Series Instruction Manual

HWS 15A-150A Series. Instruction Manual

Dual output. Fig. 2.1 Current foldback characteristics

Applications Manual of DPG serises

EVS RP6020. Instruction Manual

RP Instruction Manual

CN100A110 SERIES Instruction Manual

ZWS-BP Series. Instruction Manual. TDK-Lambda. ZWS-BP Series. Instruction Manual A C

<Designed to meet harmonic current regulations> Board type, ultra-small size, and low cost

PAF500F24 SERIES Instruction Manual

PAF F280 SERIES Instruction Manual

INDUSTRIAL POWER SUPPLIES SFL-SERIES

ZWS-BAF Series. Instruction Manual. TDK-Lambda. ZWS-BAF Series Instruction Manual A H

Features. Description. Table of Contents

Power Supply Technical Information

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Switching Power Supply

MODEL MMC8A-1 MMC8A-2 MMC8A-3 V1 +5V 1.2A +5V 1.1A +5V 1.2A DC OUTPUT V2 +12V 0.1A +15V 0.1A +12V 0.1A V3-12V 0.1A -15V 0.1A -5V 0.

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

TECHNICAL DATA Troubleshooting Tips for DC to DC Converter

PS6R 480W Switching Power Supply

PAF SERIES. Features. Model naming method PAF 500 F / Conformity to RoHS Directive. Applications. Product Line up. DC/DC Module 400W-700W PAF

(typ.) (Range) ±18 330# 89 MPW MPW

TDK Lambda TEP INSTRUCTION MANUAL

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

(DC/DC) SERIES to 96.5% (typical) Product Lineup. Ordering Information. Features. General Description. Super high efficiency

HWS Series Instruction Manual

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Switching Power Supply

(typ.) (Range) Load

GB60S 60W Single Output General Purpose Series

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

PAF F48 SERIES Instruction Manual

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

CN-A110 SERIES Instruction Manual

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

PFE700SA Series Instruction Manual

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

EPM1510SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

TDK-Lambda ZWS240BP/A SPECIFICATIONS

S8VK-S (30/60/120/240/480-W Models)

Table 2 Models BST12M-0.7S03PDM BST12M-0.7S06PDM BST12M-0.7S10PDM Conditions Input voltage range

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

2W, Low Cost DIP, Dual Output DC/DC Converters

TDK-Lambda ZWS300BAF/A

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

Model Number Structure

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

*Last time buy date of PAH200H: Mar. 29, *Last time buy date of PAH50S, 75S, 100S, 150S, 200S: Dec. 2, PAH450S PAH75D

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

MODEL LEP100F-24 LEP100F-36 LEP100F-48 DC OUTPUT +24V 4.2(Peak 7)A +36V 2.8(Peak 4.7)A +48V 2.1(Peak 3.5)A

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

PFE1000FA Series. Instruction Manual

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

DH50 SERIES. DATASHEET Rev. A

Maximum input voltage 420V or less Including peak value

Basic Characteristics Data

Instruction Manual PFE500F 1000F SERIES. TDK-Lambda PFE500F 1000F Series INSTRUCTION MANUAL

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Transcription:

Basic Characteristics Data Basic Characteristics Data Model EA12F NA12F EA24F NA24F Circuit method Switching frequency [z] Active filter 4-1 Flyback converter 2-15*2 Active filter 5-7 Forward converter 13 Input current [A] *1 *1 The value of input current is at ACIN 115V and %. *2 Burst operation at light loading, frequency is change by use condition. Please contact us about detail. Rated input fuse Inrush current protection circuit Material PCB/Pattern Single sided Double sided Series/Parallel operation availability Series operation Parallel operation 1.2 25V 4A Thermistor FR-4 Yes Yes No 2.4 25V 8A Thermistor FR-4 Yes Yes No -6

1 Terminal Blocks -8 2 Functions 2.1 Input Voltage Range 2.2 Inrush Current Limiting 2.3 Overcurrent Protection 2.4 Overvoltage Protection 2.5 Output Ripple and Ripple Noise 2.6 Output Voltage Adjustment Range 2.7 Isolation 2.8 Signal Output 3 Series/Parallel Operation -1 3.1 Series Operation 3.2 Parallel Operation -1-1 4 Assembling and Installation Method -1 4.1 Installation Mounting methods 4.2 Derating curve depend on input voltage 4.3 Derating curve depend on ambient temperature 4.4 Expected Life and Warranty 4.5 Applicable Electric Cable 4.6 Others -1-11 -11-12 -13-13 5 Option -13 5.1 Outline of option -13-7

1 Terminal Blocks EA12F NA12F 45 4 5 6 7 6 7 1 2 3 1 2 3 EA24F NA24F 45 4 5 6 7 6 7 1 2 3 1 2 3 Terminal Terminal Number Name Function 1 PE Protective earth Terminal 2 AC (N) Input Terminals 3 AC (L) 4 +VOUT +Output Terminals 5 -VOUT -Output Terminals 6 DC_OK LED for output voltage confi rmation 7 TRM Adjustment of output voltage -8

2 Functions 2.1 Input Voltage Range Input voltage range of the power supplies is from AC85V to AC264V. To comply with safety standards, input voltage range is AC- AC24V (5/Hz). If input value doesn t fall within above range, a unit may not operate in accordance with specifi cations and/or start hunting or operate protection circuit or fail. If you need to apply a square waveform input voltage, which is commonly used in UPS and inverters, please contact us. When the input voltage changes suddenly, the output voltage accuracy might exceed the specifi cation. Please contact us. When the power supply is used with DC voltage input, an external DC fuse is required for protection. Consult us for more details. If the input voltage is more than AC25V, power factor correction does not work and the power factor deteriorates. Consult us for more details. (except EA24F, NA24F) Operation stop voltage is set at a lower value than of a standard version (derating is needed). -Use Conditions Output EA12F,NA12F 7W EA24F,NA24F W Input AC5V or DC7V Duty 1s/3s *Please avoid using continuously for more than 1 second under above conditions. Doing so may cause a failure. 2.2 Inrush Current Limiting An inrush current limiting circuit is built-in. If you need to use a switch on the input side, please select one that can withstand an input inrush current. Thermistor is used in the inrush current limiting circuit. When you turn the power ON/OFF repeatedly within a short period of time, please have enough intervals so that a power supply cools down before being turned on. 2.3 Overcurrent Protection A overcurrent protection circuit is built-in and activated at 15% of the rated current. A unit automatically recovers when a fault condition is removed. Please do not use a unit in short circuit and/or under an overcurrent condition. Intermittent Operation Mode (except EA24F, NA24F) When the overcurrent protection circuit is activated and the output voltage drops to a certain extent, the output becomes intermittent so that the average current will also decrease. 2.4 Overvoltage Protection An overvoltage protection circuit is built-in. If the overvoltage protection circuit is activated, shut down the input voltage, wait more than 3 minutes and turn on the AC input again to recover the output voltage. Recovery time varies depending on such factors as input voltage value at the time of the operation. Note : Please avoid applying a voltage exceeding the rated voltage to an output terminal. Doing so may cause a power supply to malfunction or fail. If you cannot avoid doing so, for example, if you need to operate a motor, etc., please install an external diode on the output terminal to protect the unit. 2.5 Output ripple and ripple noise Output ripple noise may be infl uenced by measurement environment, measuring method fi g 2.1 is recommended. +Vout -Vout Osiloscope/ Ripple noise meter Bw:2MHz C1 C2 + 15mm Load Differential probe C1:Film capacitor.1mf C2:Aluminum electrolytic capacitor 22 mf Fig.2.1 Measuring method of Ripple and Ripple Noise 2.6 Output Voltage Adjustment Range To increase an output voltage, turn a built-in potentiometer clockwise. To decrease the output voltage, turn it counterclockwise. 2.7 Isolation When you run a Hi-Pot test as receiving inspection, gradually increase the voltage to start. When you shut down, decrease the voltage gradually by using a dial. Please avoid a Hi-Pot tester with a timer because, when the timer is turned ON or OFF, it may generate a voltage a few times higher than the applied voltage. 2.8 Signal Output Functions of LED indicators. Functions of LED indicators and signal output in the form of are shown below. Checking the presence/absence of voltage at the output terminal of a power supply is possible. Table 2.1 Description of the signal output Signal Output Normal Output is decreasing DC_OK (LED: Green) ON OFF

3 Series/Parallel Operation 3.1 Series Operation You can use a power supply in series operation. The output current in series operation should be lower than the rated current of a power supply with the lowest rated current among the power supplies that are serially connected. Please make sure that no current exceeding the rated current fl ows into a power supply. Power + Supply - Power + Supply - (a) Load Power + Supply - Power + Supply - (b) Load Load 4 Assembling and Installation Method 4.1 Installation Mounting methods Below shows mounting orientation. If install other then standard mounting orientation (A), please fi x the power supply for withstand the impact and vibration. DIN rail (A) Standard (B) (C) Fig.3.1 Examples of connecting in series operation 3.2 Parallel Operation There is no current balance function. When operating in parallel, such as diode-or, please use on the output voltage was adjusted enough to balance the current. Exceeds the rated output current, the output is shut down. Redundancy operation is available by wiring as shown below. Power Supply Power Supply + - + - I1 I2 I3 Load Fig.3.2 Example of connecting in redundancy operation (D) (E) Fig.4.1 Mounting orientation When you mount a power supply on a DIN rail, have the area marked A catch one side of the rail and push the unit to the direction of B. To remove the power supply from the rail, either push down the area marked C or insert a tool such as driver to the area marked D and pull the unit apart from the rail. When you couldn t remove the unit easily, push down the area marked C while lightly pushing the unit to the direction of E. C E Even a slight difference in output voltage can affect the balance between the values of I1 and I2. Please make sure that the value of l3 does not exceed the rated current of a power supply. l3 [ rated current value A B D Fig.4.2 Installation method -1

Shown below the notes about installation clearance of a unit. 1 Installation clearance at above and below the unit. Please have clearance of at least 25mm above and below the unit to avoid heat accumulation. 2 Installation clearance at the side of the unit. Please have clearance of at least 15mm side the unit to avoid interfering with heat radiation from housing. However, refer to Table 4.1, if adjacent device of the unit (including power supply) is a heat source. 2 1 25mm or more EA12F, NA12F 4 3 2-3 (D), (E) (C) Vin=AC85V - 17V * -2-1 1 2 25 3 4 45 5 65 7 * Derating curve depend on input voltage is required. Fig.4.5 Derating curve depend on ambient temperature (B) (A) (D), (E) (C) (B) (A) Fig.4.3 Installation clearance 1 25mm or more Table 4.1 Installation clearance at the side of the unit. No. Model Adjacent device of the unit Non-heat source Heat source(*) 1 EA12F, NA12F 15mm or more 25mm or more 2 EA24F, NA24F 15mm or more 25mm or more *Reference value when same power units are adjacent. 4.2 Derating curve depend on input voltage Derating curve depend on input voltage. Derating curve depend on input voltage is shown in Fig.4.4. Load Factor [%] 85 [AC V] Fig.4.4 Derating curve depend on input voltage 4.3 Derating curve depend on ambient temperature The operative ambient temperature as different by input voltage. Derating curve is shown below. In the hatched area,the specifi cation of Ripple,Ripple Noise is different from other area. Derating Curve () 7 4 3 2 Vin=AC17V 264V -3-2 -1 1 2 3 4 45 5 55 65 7 Fig.4.6 Derating curve depend on ambient temperature EA24F, NA24F 4 (D), (E) (C) 2 Vin=AC85V - 17V * -3-2 -1 115 2 3 4 45 5 65 7 (B) (A) * Derating curve depend on input voltage is required. Fig.4.7 Derating curve depend on ambient temperature 4 2 (D), (E) Vin=AC17V 264V (C) (B) -3-2 -1 1 2 25 3 35 4 5 55 65 7 Fig.4.8 Derating curve depend on ambient temperature (A) -11

Ambient temperature indicates the temperature of the inlet of the air. Table 4.2 Specifi ed temperature of the measurement point No. Model temperature measurement point 1 EA12F, NA12F 75C 2 EA24F, NA24F 75C 4.4 Expectancy life and warranty Please note derating curve depend on input voltage is required. Expectancy Life. Ambient temperature measurement point Airflow Fig.4.9 Ambient temperature measurement point EA12F, NA12F 4 3 2 Vin=AC85V - 264V Forced air (A) - (E) -3-2 -1 1 2 3 4 5 7 Fig.4.1 Derating curve depend on ambient temperature EA24F, NA24F 4 2 Vin=AC85V - 264V Forced air (A) - (E) -3-2 -1 1 2 3 4 5 7 Fig.4.11 Derating curve depend on ambient temperature Temperature of Forced air Use the temperature measurement point as shown in Fig 4.12. Please use at the temperature does not exceed the values in Table 4.2. Please also make sure that the ambient temperature does not exceed 7C. Temperature Airflow measureing point Table 4.3 Expectancy Life (EA12F, NA12F) Expectancy Life Mounting Cooling Input Average ambient Load factor Load factor method method voltage temperature (year) Io[75% 75%<Io[% A Ta = 4C or less 1years 6years Ta = 5C 5years 3years Ta = 45C or less 9years 6years Ta = 55C 4years 3years B Ta = 35C or less 1years 7years Ta = 45C 5years 3years Ta = 4C or less 1years 8years Ta = 5C 5years 4years C Ta = 2C or less 1years 1years Ta = 3C 1years 7years Ta = 35C or less 1years 7years Ta = 45C 6years 4years D and E Ta = 15C or less 1years 6years Ta = 25C 7years 3years Ta = 3C or less 1years 5years Ta = 4C 5years 2years A,B,C,D and E Forced air AC85-264V Ta = 7C 5years 3years Table 4.4 Expectancy Life (EA24F, NA24F) Expectancy Life Mounting Cooling Input Average ambient Load factor Load factor method method voltage temperature (year) Io[75% 75%<Io[% A Ta = 35C or less 8years 5years Ta = 45C 4years 2years Ta = 4C or less 8years 6years Ta = 5C 4years 3years B Ta = 2C or less 1years 5years Ta = 3C 5years 2years Ta = 3C or less 8years 5years Ta = 4C 4years 2years C Ta = 5C or less 1years 1years Ta = 15C 1years 6years Ta = 25C or less 1years 7years Ta = 35C 5years 3years D and E Ta = C or less 1years 5years Ta = 1C 5years 2years Ta = 15C or less 9years 5years Ta = 25C 4years 2years A,B,C,D and E Forced air AC85-264V Ta = 7C 5years 3years Airflow Fig.4.12 Temperature measurement point (Forced air) -12

Warranty Mounting method A B C D and E A,B,C,D and E Table 4.5 Warranty (EA12F, NA12F) Warranty term Cooling Input Average ambient Load factor Load factor method voltage temperature (year) Io[75% 75%<Io[% Ta = 4C or less 5years 5years Ta = 5C 5years 3years Ta = 45C or less 5years 5years Ta = 55C 4years 3years Ta = 35C or less 5years 5years Ta = 45C 5years 3years Ta = 4C or less 5years 5years Ta = 5C 5years 4years Ta = 2C or less 5years 5years Ta = 3C 5years 5years Ta = 35C or less 5years 5years Ta = 45C 5years 4years Ta = 15C or less 5years 5years Ta = 25C 5years 3years Ta = 3C or less 5years 5years Ta = 4C 5years 2years Forced air AC85-264V Ta = 7C 5years 3years When a mass capacitor is connected with the output terminal (load side), the output might become the stop or an unstable operation. Please contact us for details when you connect the capacitor. 5 Option 5.1 Outline of option -C -Option -C units have coated internal PCB for better moisture resistance. -N2 -Option -N2 units have attachment with screw mounting instead of DIN rail mounting. Mounting holes pitch are shown in Table 5.1. Mounting method A B C D and E A,B,C,D and E Table 4.6 Warranty (EA24F, NA24F) Warranty term Cooling Input Average ambient Load factor Load factor method voltage temperature (year) Io[75% 75%<Io[% Ta = 35C or less 5years 5years Ta = 45C 4years 2years Ta = 4C or less 5years 5years Ta = 5C 4years 3years Ta = 2C or less 5years 5years Ta = 3C 5years 2years Ta = 3C or less 5years 5years Ta = 4C 4years 2years Ta = 5C or less 5years 5years Ta = 15C 5years 5years Ta = 25C or less 5years 5years Ta = 35C 5years 3years Ta = C or less 5years 5years Ta = 1C 5years 2years Ta = 15C or less 5years 5years Ta = 25C 4years 2years Forced air AC85-264V Ta = 7C 5years 3years Fig.5.1 Image of option -N2 4-f4.5 4.5 Applicable Electric Cable B Input terminals, Output terminals Table 4.7 Applicable Wire Solid wire Stranded wire Sheath strip length Input terminals Output terminals Diameter.5 mm to 2.6 mm (AWG.24 to AWG.1).2mm 2 to 5.2mm 2 (AWG.24 to AWG.1) Conductor diameter more than.18mm 8mm A Fig.5.2 Mounting place (screw holes) 4.6 Applicable Electric Cable While turning on the electricity, and for a while after turning off, please don t touch the inside of a power supply because there are some hot parts in that. Table 5.1 Mounting holes pitch No. Model A B 1 EA12F, NA12F 24mm 133mm 2 EA24F, NA24F 34mm 133mm -13