echnical data sheet MP-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx 6 m orque 8 m ominal voltage AC 4 V Control: Open-close or -point Optimum protection against Corrosion and chemical influences UV radiation Damp and condensation Low temperatures (for use in ambient temperatures up to 4 C, there is a separate actuator available with built-in heater ex works) echnical data Electrical data ominal voltage AC 4 V, 5/6 Hz ominal voltage range AC 85 65 V Power consumption Operation At rest Wire sizing 5 W @ nominal torque 6 W 6 VA x EPU, ma (,5) A, AC 5 V (adjustable %) Connection Motor Halogen-free cable m, x 75 mm Halogen-free cable m, x 75 mm Functional data orque (nominal torque) Min 8 m @ nominal voltage Direction of rotation Reversible with switch resp Manual override Gearing latch disengaged with pushbutton, can be locked Angle of rotation Max 95, can be limited at both ends with adjustable mechanical end stops Running time 5 s / 9 Sound power level Max 5 db (A) Position indication Mechanical, pluggable Safety Protection class II totally insulated Degree of protection IP66 IP67 EMC Low-voltage directive CE according to 4/8/EC CE according to 6/95/EC Mode of operation yp B (E 67-) Rated impulse voltage 5 kv (E 67-) Control pollution degree 4 (E 67-) Ambient temperature 5 C (actuator with built-in heater 4 5 C) on-operating temperature range 4 5 C Ambient humidity % rh Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page Weight Approx kg Safety notes he actuator is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport Caution: Power supply voltage It may only be installed by suitably trained personnel All applicable legal or institutional installation regulations must be complied with he cover of the protective housing may be opened for adjustment and servicing When it is closed afterwards, the housing must seal tight (see installation instructions) he device on the inside may only be opened up in the factory It does not contain any parts that can be replaced or repaired by the user he cable must not be removed from the device wwwbelimocom -MP-S en v 58 Subject to changes /
MP-S Safety notes Product features Fields of application Robustline damper actuator, AC 4 V, 8 m, with auxiliary switch (continued) When calculating the required torque, the specifications supplied by the damper manufacturers (cross section, design, installation site), and the air flow conditions must be observed he device contains electrical and electronic components and is not allowed to be disposed of as household refuse All locally valid regulations and requirements must be observed he information on chemical resistance refers to laboratory tests with raw materials and finished products and to trials in the field in the areas of application indicated he materials used may be subjected to external influences (temperature, pressure, constructional fixture, effect of chemical substances etc), that cannot be simulated in laboratory test or field trials he information regarding areas of application and resistance can therefore only serve as a guideline In case of doubt, we recommend that you definitely carry out a test his information does not imply any legal entitlement Belimo will not be held liable and will provide no warranty he chemical or mechanical resistance of the materials used is not alone sufficient for judging the suitability of a product Regulations pertaining to combustible liquids such as solvents etc must be taken into account with special reference to explosion protection he actuator is particularly suited for use in difficult conditions, eg in the field of: Wood drying Animal breeding Food processing Agricultural Swimming baths / Bathrooms Rooftop units General outdoor applications Low temperatures (the separately available actuator with built-in heater ex works is suitable for use up to 4 C) Changing climate / frequent and strong fluctuations in temperature (Recommendation: to prevent internal condensation, use the separately available actuator with built-in heater ex works) Resistances est est standard esting body oxious gas tests E 668--6 Fraunhofer Institute IC / DE Salt fog spray test E 668--5 Fraunhofer Institute IC / DE Ammoniac test DI 596- Fraunhofer Institute IC / DE Climatic test IEC 668-- rikon Solutions AG / CH Disinfectants (animals) rikon Solutions AG / CH UV test (Solar radiation at ground level) E 668--5 E 668--6 Used materials Actuator parts Material Actuator housing Polypropylene (PP) Cable glands / hollow shaft Polyamide (PA) Connection cable FRC Clamp / screws in general Steel 444 seals EPDM Form-fit insert Anodised aluminium Quinel / Zug CH Simple direct mounting Manual override Simple direct mounting on the damper spindle with a universal spindle clamp, supplied with an anti-rotation strap to prevent Manual override with pushbutton possible (the gear is disengaged for as long as the button is pressed or remains locked) Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops Standard setting 9 he housing cover must be removed to set the angle of rotation High functional reliability he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached Flexible signalization Flexible signalization with adjustable auxiliary switch ( %) / -MP-S en v 58 Subject to changes wwwbelimocom
MP-S Robustline damper actuator, AC 4 V, 8 m, with auxiliary switch Accessories Description Data sheet Electrical accessories Heating V with thermostat H * - H Heating V with humidistat HH * - HH Mechanical accessories Various form-fit inserts - Z-M * only available fitted in separate actuator Electrical installation ote Caution: Power supply voltage Other actuators can be connected in parallel ote the performance data Direction of rotation Wiring diagrams Open-close control -point control L S S S % L S S S % Cable colours: = blue = brown = white S = violet S = red S = white S S S S S S Dimensions [mm] Dimensional drawings 7 4 4 8 4 5 5 4 6 8 6 Damper spindle Length 58 8 84 wwwbelimocom -MP-S en v 58 Subject to changes /
775-A MP / SMP 58 MP 8 4 SMP 4 4 4 4 m 9 9 4 5 A 65 8 m Ø= wwwbelimocom m m M-MP/SMP v 97 /
MP / SMP L L AC 4 V / DC 4 V S S S S S S % M4P SM4P M4P-S SM4P-S M4PP5 SM4PP5 AC 4 V L L L L S S S S S S S S S MP SMP MP-S SMP-S % AC 4 V / DC 4 V Y U DC V DC V 5 M4P-SR M4P-MF SM4P-SR SM4P-MF AC 4 V L Y U 5 DC V DC V 5 MPSR SMPSR / M-MP/SMP v 97 wwwbelimocom