Boiler room components 0459EN October 2013 Safety pressure switch with manual reset

Similar documents
Boiler room components 0459EN February 2018 Manual reset safety pressure switch

Metering systems 0483EN October 2013 Metering units for sanitary or service water

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Actuator for mixing valves 0262EN March 2016

PUSH FITTINGS INSTA INST LLAT ALLA ION TION AND AND COMPONENTS COMPONENTS

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

Manifolds and preassembled groups 0687EN November 2017 Modular manifolds for domestic water systems with outputs connection 1/2 or 3/4 Eurocone

Metering systems 0368EN April /4 domestic water unit outputs

Compact System NRGS 11-2 NRGS Original Installation Instructions English

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Installation, Operation and Maintenance Manual

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL

Rotary Limit Switches Driver FRS Series

PISTON ACCUMULATOR. Installation and operation manual Revision

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

KAN-therm System. Series 71A, 75A, 51A, 55A manifolds. installation and maintenance instructions

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

PCS. Proof of closure switch for safety gas valves. delta-elektrogas.com EE

VMH. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN EE

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

Rotary Limit Switches Driver FRM Series

lubrication systems PEGPEO 5N-10N-25N-210N pumps for progressive systems

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

PBV s Engineering Excellence At Work

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

VALIADIS S.A. HELLENIC MOTORS

THROTTLE VALVES FOR RELAYS AND RADIATORS Series 2009

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

M4 Troubleshooting 42

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

ZB0050 / ZB0051 ZB0070 / ZB0071

3. Operating instructions: Minor 200

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Pressostats and thermostats CAS

Flow Meter Terminal Boxes

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

VUD: 2-way flanged valve, PN 6 (pn.)

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Bolier room components 0870EN October 2017 Boiler room manifold with hydraulic separator

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Guide

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Pressure chlorine changeover unit C 7520

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300

Dragone Pump DROPSA SpA In conformity with section 1.7.4, app. I, EEC Dir. 98/37/CE

Type overview. R B2 en-gb subject to changes 1

Liquid filled Thermometers

Valves For Cryogenic Applications

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

VPI45..Q with pressure test points. Combi valves, PN 25

GTFLOW EXTENSION MANIFOLD ASSEMBLY INSTRUCTIONS

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Instructions for installation, operation and maintenance of: GATE VALVE

Mounting and Operating Instructions EB 5868/5869 EN

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Block mounting filter, for sandwich plate mounting

Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B B0616

502 VALVE WITH UM1.5 ELECTRIC ACTUATOR. Model/Ref:

Compact pressure switch Model PCS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

These installation and maintenance instructions must be read in full and completely understood before the installation!

Rosemount 485 Annubar Threaded Flo-Tap Assembly

Economizer pressure Reducing valves

DIAMOND POINT VIBRATING PROBES

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Installation and Operating Instructions

Line filter with filter element according to DIN 24550

VG7000 Series Bronze Control Valves

Valves. Slow opening and rapid closing solenoid valves VM-L (E1111 rev /11/2012)

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps

Pressure Control, Differential Pressure Control, Type RT

Installation and Operating Instructions Electric Vibrators HV/VFL Series

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

ST11 Structural Straightening

1. GENERAL SAFETY INSTRUCTIONS 2. GENERAL SAFETY RULES GENERAL OBSERVATIONS.

VPI45..Q with pressure test points. Combi valves, PN 25

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

VTZ variable speed Reciprocating compressors

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series

Pumps and pumping units SL i & Micro C

RVP-R- VAV controller. In explosion-proof version

Access Interlock with Safety Switch User Manual - Original Language Version

Installation and Operation Manual. Value Switch Package (VSP and VSP+)

Transcription:

0459EN October 03 Safety pressure switch with manual reset Installation The lockout pressure switch must be installed by qualified personnel. The pressure switch K374Y00 can be assembled either vertically or horizontally by screwing it onto a pipe or a /4 Gc male threaded coupling after preparing the latter with a plug + paste mastic, teflon tape, or anaerobic seal; when properly applied, these materials ensure the seal on the coupling between the /4 Gj female connection of the pressure switch and the /4 Gc male part. K374Y00 Description Safety pressure switch with manual reset, for stopping the heat flow from the heat generator when the predefined maximum system pressure threshold (lockout pressure) is reached. The device is and complies with PED directive 97/3/EC. Allowed installation Setting The lockout pressure value is factory-set at 3 bar. This value can be modified with the aid of a tool, intervening on the regulation nut on the upper part of the casing; read the value on the graduated scale on the side. Triggering The device is triggered when the pressure level reaches the set lockout value; the opening of the contacts causes the heat generator to stop. Reset The system can only be reactivated by pressing the reset button on the lower part of the casing. This must be done when the pressure falls 0,4 bar lower than the set value. Main characteristics /4 F connection Two normally closed contacts (wire section 0,5 4 mm²) Reset button (differential 0,4 bar, tolerance ±0, bar) Graduated scale, visible from the outside Nominal current 6 A (resistive load) --- 0 A (inductive load) Nominal voltage 50 V Operating temperature range -0 55 C Protection degree IP44 Not allowed installation The connection pipe between the pressure switch and the system must have a minimum internal diameter of 8 mm if the pipe is less than one metre long, 5 mm if the pipe is more than one metre long, and 0 mm if it feeds other devices apart from the pressure switch (regardless of its length). The pressure switch must be fixed in place using an open-end spanner no.9 (recommended tightening moment: 35 Nm). If the theoretical short-circuit current is greater than the maximum nominal capacity of the electric contacts, it is compulsory to use a current protection device upstream from the pressure switch, with an intervention value equal to - or less than - 8 A. Electric connection The pressure switch K374Y00 has two NC electric contacts isolated from each other. When the system is subjected to a normal pressure level, the contacts remain closed. When the maximum set lockout pressure value is reached, both contacts are opened. Technical data Fluid temperature range 4 0 C Max. working pressure 5 bar Factory calibration 3 bar Regulation range 5 bar Certifications Compliance with PED directive 97/3/EC and ISPESL PS/00/0C EC mark

0459EN October 03 Safety pressure switch with manual reset Regulation To regulate (if necessary) the lockout pressure value, intervene on the regulation nut; read the value on the graduated scale. REGOLATION NUT Normative references R collection INAIL (I.S.P.E.S.L.) R collection for boiler room safety, protection and checks: italian D.M...75. PED European Pressure Equipment Directive (97/3/EC). /LOAD CONNECTION CONNECTION RESET BUTTON GRADUATED SCALE Product specifications K374Y00 Safety pressure switch with manual reset. Lockout pressure factory calibration 3 bar. Regulation range 5 bar. /4 F connection. Button for manual reset (differential 0,4 bar; tolerance ±0, bar). Two normally closed contacts (wire section 0,5 4 mm²). Graduated scale, visible from the outside. Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 50 V. Protection degree IP44. Dimensions 04x00x60 mm (LxHxW). Operating temperature range -0 55 C. Fluid temperature range 4 0 C. Max. working pressure 5 bar. Compliance with PED directive 97/3/EC.. Use Avoid the following situations at all costs: Exceeding the envisaged outdoor temperature (55 C) Exceeding the envisaged liquid temperature (0 C) Using with unclean water Using in environments with a highly corrosive atmosphere Initial start-up Before using the pressure switch, make sure that: the appropriate current protection devices are installed, if necessary the electrical connection has been made correctly there are no water leaks from the hydraulic connection (pressure switch - system) Maintenance and Checks Every year: visual check for any fluid leakages and/or corrosion Every 3 years: check the opening of the contacts Any repair and/or modification on the K374Y00 must be authorised by Giacomini S.p.A. in writing. Failure to observe any single one of the above indications will relieve Giacomini S.p.A of all civil and criminal responsibility. Dimensions H L W L [mm] H [mm] W [mm] 04 00 60 Additional information For further information, visit the website www.giacomini.com or contact the technical service: ' +39 03 9337 6 +39 03 9355 * consulenza.prodotti@giacomini.com This information is intended as an example. Giacomini S.p.A. reserves the right to modify the contents - at any time and without prior warning - for technical or commercial reasons. The information in this technical sheet does not exempt the user from scrupulously observing the existing regulations and standards relating to good technical practices. Giacomini S.p.A. Via per Alzo, 39-807 San Maurizio d Opaglio (NO) Italy

0460EN October 03 Manual reset pressure switch Installation The lockout pressure switch must be installed by qualified personnel. The pressure switch can be mounted either in vertical or in horizontal position, and with the cable glands turned to the floor, by screwing it to on a pipe or threaded fitting ¼ Gc male, that shall have been opportunely prepared with tow + putty in paste or Teflon tape, or anaerobic sealant (such materials, opportunely applied ensure the tightness of the coupling of the ¼ Gj female connection of the pressure switch with the male part ¼ Gc. K374Y00 Description The minimum pressure switch allows the control of the minimum pressure of a hot water system, according to 97/3/CE (PED) Directive and the provisions of the Italian (I.S.P.E.S.L.) Raccolta R Allowed installation Operation The pressure switch has two electrical contacts, normally open. With pressurized system, the contacts both close. Both contacts will be opened when the set minimum pressure of block will be reached. Restoration In order to reactivate the system, press the reset pushbutton, positioned on the higher part of the pressure switch when the pressure is risen 0.5 bar over the block value. Main characteristics /4 F connection Differential for reset 0,5 bar Tolerance ±0, bar Nominal current 6 A (resistive load) --- 0 A (inductive load) Nominal voltage 50 V Operating temperature range -0 55 C Protection degree IP44 Technical Data Fluid temperature range 4 0 C Max. working pressure 5 bar Factory calibration 0,9 bar Regulation range 0,5,7 bar Not allowed installation The connection pipe between the pressure switch and the system shall have minimum internal diameter of 8 mm, if the pipe is less than a meter long, 5 mm if the pipe length is higher than a meter, and 0 mm if it supplies other devices in addition to the pressure switch, regardless of its length. The fastening of the pressure switch shall be made with a fixed key no.9 (recommended torque setting: 35 Nm). Where the theoretic short circuit voltage is higher than the maximum nominal capacity of the electrical contacts, upstream of the pressure switch the use of a protection with intervention values lower than or equal to 8A is compulsory. Electrical connection The pressure switch K374Y00 has two electrical contacts, insulated one from the other, normally open. When the system is pressurized, both contacts close. When the minimum set block pressure is reached, both contacts are opened. Certifications Compliance with PED directive 97/3/EC and ISPESL PS/00/0C EC mark

0460EN October 03 Manual reset pressure switch Regulation In order to regulate the block pressure value, if needed, act on the regulation nut; this value is readable on the graduated scale. The following situations must be absolutely avoided: overcoming of the expected external temperature (55 C) overcoming of the expected temperature of the liquid (0 C) use with not clean water use in rooms with strongly corrosive atmosphere Normative references R collection INAIL (I.S.P.E.S.L.) R collection for boiler room safety, protection and checks: italian D.M...75. PED European Pressure Equipment Directive (97/3/EC). REGULATION NUT RESET PUSHBUTTON / LOAD GRADUATED SCALE Initial start-up Before starting the pressure switch, make sure that: the opportune voltage protections are present, where requested the electrical connection is complying there are no leakage from the hydraulic connection (pressure switch-system). Maintenance and checks Every year: visual check for any fluid leakages and/or corrosion Every 3 years: check the opening of the contacts Any repair and/or modification on the K374Y00 must be authorised by Giacomini S.p.A. in writing. Failure to observe any single one of the above indications will relieve Giacomini S.p.A of all civil and criminal responsibility. Dimensions H L W L [mm] H [mm] W [mm] 04 00 60 Additional information For further information, visit the website www.giacomini.com or contact the technical service: ' +39 03 9337 6 +39 03 9355 * consulenza.prodotti@giacomini.com This information is intended as an example. Giacomini S.p.A. reserves the right to modify the contents - at any time and without prior warning - for technical or commercial reasons. The information in this technical sheet does not exempt the user from scrupulously observing the existing regulations and standards relating to good technical practices. Giacomini S.p.A. Via per Alzo, 39-807 San Maurizio d Opaglio (NO) Italy

046EN October 03 Pressure switches for autoclaves Regulation To make the regulation, observe the figure below and the minimum - maximum setting diagrams on the next page. A) Fully loosen the differential nut () B) Adjust the minimum gap nut () to establish the contact closure value (pump start); turn clockwise to increase the start pressure, or anticlockwise to reduce it C) Tighten the differential nut () until you obtain the required stoppage pressure K374Y003 K374Y004 Description Pressure switch for use with cold water in autoclave systems (e.g. fire-fighting systems). The switch automatically regulates the starting and stopping of the circulator, on the basis of the pressure values set. The electric contacts are of the normally closed type. The device complies with PED directive 97/3/EC. Main characteristics /4 F connection Three NC electric contacts (in brass alloy with Ag - Ni weld beading) Nominal current 6 A (resistive load); 0 A (inductive load) Nominal voltage 500 V Ambient temperature range -0 55 C Protection degree IP44 Technical data Fluid temperature range 4 55 C Max. working pressure K374Y003: 5 bar K374Y004: bar Factory calibration K374Y003:,4,8 bar K374Y004: 5 7 bar Electric connections Regulation range K374Y003: 5 bar K374Y004: 3 bar Certifications Compliance with PED directive 97/3/EC EC mark

046EN October 03 Pressure switches for autoclaves Regulation range K374Y003 K374Y004 3 6 5 Maximum setting (bar) 0 9 8 7 6 5 4 Maximum setting (bar) 4 3 3 3 4 5 6 7 8 9 Minimum setting (bar) 0 0 3 4 Minimum setting (bar) Dimensions H L L [mm] H [mm] W [mm] 04 00 60 Normative references R collection INAIL (I.S.P.E.S.L.) R collection for boiler room safety, protection and checks: italian D.M...75. W Product specifications K374Y003 Pressure switch for use with cold water in autoclave systems. Factory calibration,4,8 bar. Regulation range 5 bar. /4 F connection. Three NC contacts (in brass alloy with Ag - Ni weld beading). Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 500 V. Protection degree IP44. Dimensions 04x00x60 mm (LxHxW). Operating temperature range -0 55 C. Fluid temperature range 4 55 C. Max. working pressure 5 bar. Compliance with PED directive 97/3/EC. K374Y004 Pressure switch for use with cold water in autoclave systems. Factory calibration 5 7 bar. Regulation range 3 bar. /4 F connection. Three NC contacts (in brass alloy with Ag - Ni weld beading). Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 500 V. Protection degree IP44. Dimensions 04x00x60 mm (LxHxW). Operating temperature range -0 55 C. Fluid temperature range 4 55 C. Max. working pressure bar. Compliance with PED directive 97/3/EC. PED European Pressure Equipment Directive (97/3/EC). Additional information For further information, visit the website www.giacomini.com or contact the technical service: ' +39 03 9337 6 +39 03 9355 * consulenza.prodotti@giacomini.com This information is intended as an example. Giacomini S.p.A. reserves the right to modify the contents - at any time and without prior warning - for technical or commercial reasons. The information in this technical sheet does not exempt the user from scrupulously observing the existing regulations and standards relating to good technical practices. Giacomini S.p.A. Via per Alzo, 39-807 San Maurizio d Opaglio (NO) Italy