MPS14 Rack Mount Power Supply

Similar documents
ALLEN&HEATH WARNING HIGH VOLTAGES. Power Supply Unit (PSU) work should only be carried out by qualified personnel.

4070 Subwoofer Owners' Manual

User Manual Subwoofer Module DS 2.0 Hypex DS - Series

USER MANUAL 6 Position Powered Rack for TD Series Modules TDR 01 AC

LED Twister II. User manual UK Version 1.0

USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP

28W WORK LAMP Model: CTL28 Part No:

CANARY AUDIO. Vacuum Tube Preamplifier CA-800 OWNER S MANUAL. Handcrafted in California MADE IN USA

100 Watt Power Amp 50 Watts x 50 Watts Single Rack Space

Rental Industry Safety Tester Safe Check 5s

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Owner Handbook. Nebula Blizzard v2. Snow Machine

Technical Information Manual

DC POWER SUPPLY ALIMENTATION C.C.

Owner Handbook. Nebula Blizzard v3. Snow Machine. L69500 Nebula Blizzard v3.indd 1 14/07/ :47

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Battery Charger JCB- SCH20LI.2

INSTRUCTIONS FOR USE

WARNINGS, CAUTIONS AND NOTES

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

Battery Charger JCB-FCH20LI2

QTFX-F1, QTFX-F2 FLAME EFFECT

Models: EP EP EP EP EP EP USER MANUAL ENGLISH

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

USER MANUAL PAR56 LED PAR CANS

REX II Power WARRANTY REGISTRATION FORM

CANARY AUDIO CA-400. Vacuum Tube MM/MC Phono Preamplifier OWNER S MANUAL. Handcrafted in California MADE IN USA

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

HD18F2M1.

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

02OWNER S MANUAL 06 TROUBLESHOOTING 08LIMITED WARRANTY

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

READ AND SAVE THESE INSTRUCTIONS FOR THE DUCTSTAT TEMPERATURE SENSITIVE SWITCH

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

OWNER S MANUAL Please read this manual before operating your power supply

12 amp RMS Battery Charger

24V DC - 1/2 SQUARE DRIVE IMPACT WRENCH KIT

Declaration of Conformity

DSP led gaming monitor USER MANUAL

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

Operating instructions in the back. PD1820LF

MANLEY LABORATORIES, INC. MANLEY REFERENCE JUNIOR DAC OWNER'S MANUAL 20 BIT DIGITAL TO ANALOG CONVERTER

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

Battery Charger JCB-FCH12Li

Operating instructions in the back. PD1420LP

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

Power-edge. Pro. User manual. Power-edge Pro User Manual

ADN-W L 10. Battery Charger. Instruction manual

82V LITHIUM-ION BATTERY CHARGER GC 400

Fiber Optic Illuminator. Model 21AC Model 21DC

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

SPECTRA ENGINEERING PTY LTD. MXPS15 Series Technical Manual

SUBMERSIBLE WATER PUMP

ORIGINAL INSTRUCTIONS

PM - Projector Mount System

Model MC4 MEDIA CONTROL by OWI

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

58kHz AM Deactivator DB104 Instruction Manual V1.0

REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S MANUAL.

LOUDSPEAKER OWNER'S MANUAL

HAWK. HAWK G2 Raptor Orbital Floor Machine Dry Stripping, Scrubbing, Stripping. Operation Care Service ENTERPRISES

Switching DC Power Supply

ASSEMBLED BY HAND IN THE USA

January Multi award winning power management systems. Super Titan Instruction Manual

THE ROCK PROFESSIONAL 2 WAY ACTIVE STUDIO MONITOR

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

LED Pinspot 2. Snapshot. User Manual

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

LED Pinspot 2. Snapshot. User Manual

Mini Hi-Fi System *MFL * SIMPLE MANUAL

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

The Rock MK II. Owner's manual PROFESSIONAL 2 WAY ACTIVE STUDIO MONITOR. v1212. v0312

PD-1 POWER DISTRIBUTION UNIT

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

SUBMERSIBLE WATER PUMP

PURE SINE WAVE DC TO AC POWER INVERTER

Owners Manual. Autosound Series Power Supply APS-100 APS-100X

Have a Bright Day! Nicholas Harmon President and CEO

MicroPod Sub User manual / Bedienungsanleitung / Manual del Usario

x 10 Belt Disc Sander

Preparing the Site. Information About the Site Requirements CHAPTER

Operating Instructions. International English. CCS Dust Extractor

Dispenser & Warmer RIC-1909 RIC-1909EXP

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Cordless Handheld. H90-LF Series. vax.co.uk

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

GP12 TECHNICAL MANUAL

ADN-W CASE. Transport & Charging Case. Instruction manual

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

INSTRUCTION MANUAL. AMS 4000 One Piece. Negative Pressure Unit (AMS-4000 NPU 230V)

FD Conveyor for FD 260 Tabber

USER MANUAL. CareCo (UK) Ltd, Hubert Road, Brentwood, Essex, CM14 4JE PAGE 1

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

Transcription:

MPS14 Rack Mount Power Supply USER GUIDE Publication AP3898

Limited One Year Warranty This product has been manufactured in the UK by ALLEN & HEATH and is warranted to be free from defects in materials or workmanship for period of one year from the date of purchase by the original owner. To ensure a high level of performance and reliability for which this equipment has been designed and manufactured, read this User Guide before operating. In the event of a failure, notify and return the defective unit to ALLEN & HEATH or its authorised agent as soon as possible for repair under warranty subject to the following conditions Conditions Of Warranty 1. The equipment has been installed and operated in accordance with the instructions in this User Guide 2. The equipment has not been subject to misuse either intended or accidental, neglect, or alteration other than as described in the User Guide or Service Manual, or approved by ALLEN & HEATH. 3. Any necessary adjustment, alteration or repair has been carried out by ALLEN & HEATH or its authorised agent. 4. The defective unit is to be returned carriage prepaid to ALLEN & HEATH or its authorised agent with proof of purchase. 5. Units returned should be packed to avoid transit damage. In certain territories the terms may vary. Check with your ALLEN & HEATH agent for any additional warranty, which may apply. This product complies with the European Electromagnetic Compatibility directives 89/336/EEC & 92/31/EEC and the European Low Voltage Directives 73/23/EEC & 93/68/EEC. Any changes or modifications to the power unit not approved by Allen & Heath could void the compliance of the product and therefore the users authority to operate it. MPS14 User Guide AP3898 Issue 4. Copyright 2001 Allen & Heath. All rights reserved Manufactured in the United Kingdom by Allen & Heath Limited Kernick Industrial Estate, Penryn, Cornwall, TR10 9LU, UK http://www.allen-heath.com 2 MPS14 User Guide

Important Safety Instructions WARNINGS - Read the following before proceeding : CAUTION ATTENTION: RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR Read instructions: Do not remove covers: Power sources: Power cord routing: Grounding: Retain these safety and operating instructions for future reference. Adhere to all warnings printed here and on the power unit. Follow the operating instructions printed in this User Guide. Operate the power unit with its covers correctly fitted. Refer any service work on the power unit to competent technical personnel only. Connect the power unit to a mains power only of the type described in this User Guide and marked on the rear panel. Use only the power cord with sealed mains plug appropriate for your local mains supply as provided with the power unit. If the provided plug does not fit into your outlet consult your service agent for assistance. Route the power cord so that it is not likely to be walked on, stretched or pinched by items placed upon or against it. Do not defeat the grounding and polarisation means of the power cord plug. Do not remove or tamper with the ground connection in the power cord. WARNING: This equipment must be earthed. Water and moisture: Ventilation: Heat and vibration: Servicing: Installation: To reduce the risk of fire or electric shock do not expose the power unit to rain or moisture or use it in damp or wet conditions. Do not place containers of liquids on it which might spill into any openings. Do not obstruct the ventilation slots or position the power unit where the air flow required for ventilation is impeded. If the power unit is to be operated in a flightcase ensure that it is constructed to allow adequate ventilation. Do not locate the power unit in a place subject to excessive heat or direct sunlight as this could be a fire hazard. Locate the power unit and its power unit away from any equipment which produces heat or causes excessive vibration. Switch off the equipment and unplug the power cord immediately if it is exposed to moisture, spilled liquid, objects fallen into the openings, the power cord or plug become damaged, during lightening storms, or if smoke, odour or noise is noticed. Refer servicing to qualified technical personnel only. Install the power unit in accordance with the instructions printed in this User Guide. Do not connect the output of power unit to any other equipment other than that specified by Allen & Heath. MPS14 User Guide 3

Important Mains plug wiring instructions. The power unit is supplied with a moulded mains plug fitted to the AC mains power lead. Follow the instructions below if the mains plug has to be replaced. The wires in the mains lead are coloured in accordance with the following code: TERMINAL WIRE COLOUR European USA/Canada L LIVE BROWN BLACK N NEUTRAL BLUE WHITE E EARTH GND GREEN & YELLOW GREEN The wire which is coloured Green and Yellow must be connected to the terminal in the plug which is marked with the letter E or with the Earth symbol. This appliance must be earthed. The wire which is coloured Blue must be connected to the terminal in the plug which is marked with the letter N. The wire which is coloured Brown must be connected to the terminal in the plug which is marked with the letter L. Ensure that these colour codes are followed carefully in the event of the plug being changed. Precautions Damage : Environment : Cleaning : Transporting : To prevent damage to the power unit cosmetics, avoid placing heavy objects on the unit, scratching the surface with sharp objects, or subjecting the power unit to rough handling and vibration. Protect from excessive dirt, dust, heat and vibration when operating and storing. Avoid tobacco ash, smoke, drinks spillage, and exposure to rain and moisture. If the power unit becomes wet, switch off and remove power immediately. Allow to dry out thoroughly before using again. Avoid the use of chemicals, abrasives or solvents. The power unit is best cleaned with a soft brush and dry lint-free cloth. The use of electrical lubricants is not recommended. The power unit should be transported in the original packing or purpose built flightcase to protect it from damage during transit. 4 MPS14 User Guide

Introduction This user guide presents a quick reference to the MPS14. We recommend that you read this fully before starting. Included is information on installing, connecting and operating the power unit along with panel drawings and technical specification. For further information on the basic principles of audio system engineering, please refer to one of the specialist publications available from bookshops and audio equipment dealers. Whilst we believe the information in this guide to be reliable we do not assume responsibility for inaccuracies. We also reserve the right to make changes in the interest of further product development. We are able to offer further product support through our worldwide network of approved dealers and service agents. You can also access our Web site on the Internet for information on our product range, assistance with your technical queries or simply to chat about audio matters. To help us provide the most efficient service please keep a record of your power unit serial number, and date and place of purchase to be quoted in any communication regarding this product. The serial number is located on the rear panel. Check out our home site for information on the company and its pedigree, our full product range and our design philosophy. www.allen-heath.com Contents Warranty... 2 Important Safety Instructions... 3 Precautions... 4 Introduction & contents... 5 The MPS14... 6 Installation... 6 Using the MPS14...7 Combining MPS14 power units...7 Fan Filter cleaning...8 Replacing the mains fuse...8 Technical Specifications...9 Internet Site...Rear Cover MPS14 User Guide 5

The MPS14 The slimline MPS14 power supply uses switch mode technology to generate the DC voltages required by the console. It will operate from a wide range of ac mains input voltages. Full protection and thermally controlled fan cooling ensures the power unit will operate consistently. The MPS14 also has a built in combiner for connection to a second supply for backup. ON PROTECT + 17V -17V + 12V + 48V ADVANCED TECHNOLOGY / HIGH POWER DELIVERY / AUTO COMBINING MPS14 CONSOLE POWER SUPPLY CAUTION DO NOT OBSTRUCT VENTILATION OPENINGS. DO NOT OPEN. NO USER SERVICEABLE PARTS INSIDE. THIS APPARATUS MUST BE EARTHED BY THE POWER CORD. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING. DISCONNECT SUPPLY BEFORE CHANGING FUSE. ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES. COUPER L'ALIMENTATION AVANT DE CHANGER LE FUSIBLE. MAINS INPUT PIN 1 = + 12V @ 4A PIN 2 = + 17V @ 6.5A PIN 3 = A GND PIN 4 = A GND PIN 5 = D GND PIN 6 = + 48V @ 500mA PIN 7 = -17V @ 6.5A T T5A 250V FUSE 100V - 230V.AC 47-63 Hz ~ 435W MAX A DIVISION OF HARMAN INTERNATIONAL INDUSTRIES LTD S/No MADE IN ENGLAND Installation Free standing The MPS14 can be operated as a freestanding unit without requiring any special cooling arrangement, but should not be accidentally or deliberately covered in any way. Always stand the unit on a firm flat surface well away from any soft furnishings or carpet. Rack mounting The MPS14 is designed as a 19 inch rack mount unit and will occupy 2U (3.5 inches) of rack space. A pair of M4 threaded holes on each side at the rear of the chassis are provided for fixing brackets for supporting the rear of the unit. An important consideration when rack-mounting the unit is the need for natural convection of airflow over the whole unit. Good ventilation below the unit, in the floor or back of the rack, will ensure a path for continuous airflow. Other equipment in the rack which is known not to produce a significant amount of heat should be mounted below the unit. Equipment which also relies on good airflow within the rack (i.e. most power amplifiers and other power supplies) should be given due consideration and some space should be provided between such units and between the MPS14 unit. Forced convection, by means of a fan-tray, may be desirable in this situation. Location As with any power supply that contains switch mode technology, it is preferable to provide a degree of physical isolation of the unit from other equipment, particularly that which carries low level audio signals, to avoid any possible interference pick-up. For this reason the unit is provided with a long (2.9m) output cable to enable it to be positioned away from the mixing console. For the same reason, when rack-mounting it is preferable to avoid locating the unit next to signal processing equipment. 6 MPS14 User Guide

Earthing Finally, some consideration should be given to the earthing arrangement of the system, at the centre of which is the console and the MPS14. The console chassis is earthed, to the mains earth, via the power supply. When rack-mounting the MPS14 care should be taken to avoid any possible ground loops in the system which may introduce audible hum or buzz to otherwise clean audio signals. Ground loops occur where signal processing equipment patched to the console, has its signal earth connected to the equipment chassis. A ground loop is formed if the chassis of the signal processing equipment and the MPS14 chassis are in electrical contact through the fixing rails they share in the rack. The MPS14 has audio 0V and mains earth connected internally. If a ground loop is formed operation of the ground lift switch on the rear panel of the MPS14 may reduce any unwanted hum or buzz. Using the MPS14 The MPS14 will operate from an ac mains supply voltage from 100V to 240V. Before switching on the power supply, check that the ac mains fuse is of the correct type and rating. This is marked on the rear panel of the power unit. The power supply is provided with an IEC type mains connector and a moulded mains plug. Check that this is suitable for connection to the wall socket outlet. Always switch the power supply off before connecting or disconnecting the console power cables, removing or installing console modules and any servicing work. In the event of an electrical storm, or large mains voltage fluctuations, immediately switch off the power supply and disconnect from the mains supply. During normal operation some heat is generated. This is expelled via the front panel ventilation holes. Combining MPS14 Power units Each MPS14 power unit has a built in combiner allowing the direct connection of other MPS14 power units for backup. Connect the two power units together using the MPS14 linking cable (A&H Part No: 002-584) by plugging into the DC output sockets of each power unit. To console MPS14 COMBINING MPS14 POWER UNITS linking cable BACKUP MPS14 Note; the linking cable can be connected to either of the two MPS14 DC output connectors on both units. MPS14 User Guide 7

Cleaning and Replacing the fan filters. At regular intervals, it is recommended that the two foam fan filters are cleaned or replaced to ensure efficient operation of the power unit. Failure to do so may reduce the efficiency or even damage the power unit. Use a vacuum cleaner to remove dust from the air intakes on the rear of the power unit If the filters need replacing contact your nearest service agent or Allen & Heath dealer. Fan filter part No: AK4070 Replacing the mains fuse The AC mains fuse is located on the rear of the MPS14 unit next to the AC mains connector. In the event of a mains surge or under-rated fuse value, the mains input fuse will rupture. Switch off the power supply and remove the mains lead plug from the MAINS INPUT socket on the rear of the unit. Check the fuse and replace if necessary. TO AVOID THE RISK OF FIRE REPLACE FUSE WITH THE CORRECT TYPE ONLY, AS INDICATED ON THE UNIT AC~ mains input voltage 100V 230V ± 10% Fuse type T 5A 250V 20mm In the event of repeated failure of the mains fuse, consult the local dealer from where the unit was purchased. 8 MPS14 User Guide

Technical specification Mains Input Voltage Range 100-240 ± 10% VAC @ 47-63 Hz Power consumption (max.) 435W Mains Fuse: 100-240 V~ T 5.0A/250V Internal Fuses: PCB Ident F1 (+12V) F2 (+48V) F18 (aux psu) Fuse type T 6.3A 250V 20mm T 1.6A 250V 20mm T 500mA 250V 20mm DC Outputs DC Voltage Rail Output Current +17 VOLTS 6.5A Max. -17 VOLTS 6.5A Max. +12 VOLTS 4A Max. +48 VOLTS 500mA Max. DC Output Socket Pin Connections Pin No: Connection 1 +12 Volts 2 +17 Volts 3 Chassis 4 A GND 5 D GND 6 +48 Volts 7-17 Volts Overall Dimensions Front Panel: 482mm x 88mm 19 inch 2U Width (excluding rack ears): 440mm 17.30 inches Height including feet: 90mm 3.5 inches Depth: 260mm 10.25 inches Weight: 6Kg 13 pounds Cable Assemblies Assembly Description A&H Part no: DC cable 2.9m MPS14 to ML5000 console cable assembly 002-583 DC LINK cable 0.75m MPS14 to MPS14 PSU LINKING cable assembly 002-584 MPS14 User Guide 9

www.allen-heath.com 10 MPS14 User Guide